Tender For repair renovation Of Lis From Jakhi Khad To G.P Thana, Mandal, Bholar, Jhagtan And Rawin In Tehsil Jubbal Distt. Shimla (H.P) (Sh: Construction Of Reinforced Cement Concrete Storage Tank Of 50000 Ltrs Cap. = 1 No., Retaining Wall/ Edge Wal
Tender Overview
Project Description
Tender for repair renovation Of Lis From Jakhi Khad To G.P Thana, Mandal, Bholar, Jhagtan And Rawin In Tehsil Jubbal Distt. Shimla (H.P) (Sh: Construction Of Reinforced Cement Concrete Storage Tank Of 50000 Ltrs Cap. = 1 No., Retaining Wall/ Edge Wall To Protect The S/Tank And Cutting In Earth Work). (Estimated Cost:- 7,51,028/-, Earnest Money Rs:- 15,020/- Time:- 3 Months.)
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in foundations , trenches etc., in earth work , lift up to 1.50 metres. Stacking the eacavated soil not more than 3 metres clear from the edge of the excavation and then returning the stacked soil in 15 cm. (fifteen centimetres) layers , when required in to plinth and sides of foundations etc., conslolidating each of the disposited layer by ramming and watering and then disposing off all excavated soil as directed with in the load of 20 mtrs. Pick and Jumper work etc. complete as per the direction of the Engineer - in - Charge. |
| 2 | Providing and laying cement concrete 1:3:6 (1cement: 3 sand: 6 graded stone aggregate 40mm (Forty millimeter nominal size) and curing complete excluding cost of from work in foundation and plinth with in all leads & lifts as per entire satisfication of Engineer-in-Charge. |
| 3 | Providing and laying cement concrete 1:1.5:3 (1cement :1.5 Sand: 3 graded stone aggregate 20 mm (Twenty millimeter nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in : |
| 4 | Foundation and Plinth with in all leads and lifts as per the direction of the Engineer in Charge. |
| 5 | Walls (Any thickness) attached pillasters, pillasters, buttresses, beam girder and contilevers upto floor two level with in all leads & lifts as per direction of Engineer - in charge. |
| 6 | Providing and laying cement concrete 1:2:4 (1cement :2 Sand: 4 graded stone aggregate 20 mm (Twenty millimeter nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in : |
| 7 | Column, pillar & post upto floor two level with in all leads & lifts as per direction of Engineer - in charge. |
| 8 | Beams, cantilevers, Girders & lintels sides and siffits of beams, hounching cantilever girder not exceeding 1 mtr. Depth. |
| 9 | Suspended Floor roofs, landing and shelves and their support balconies, beams, girders, bressumers and contilever up to floor two level with in all leads and lifts as per the direction of the Engineer - in - Charge. |
| 10 | Providing and fixing of mild steel/ tor steel reinfircement for rainforced concrete work I/C bending, binding and placing in position complete upto floor two level with in all leads and lifts as per the direction of the Engineer in Charge. |
| 11 | Prov.form work with steel plates 3.15mm thick welded with angle iron frame 30 x 30 x 5mm so as to give a fair finish including centring, shuttering,strutting & propping etc. with wooden battens and ballies, height of propping & centering below supporting floor to ceiling not exceeding 4mtr.& removal of same for insitu rainforceed concrete and plain concrete work complete in all leads and lifrs and as per the directioin and to the entire satisfaction of the Engineer-in-Charge :- |
| 12 | Vertical surfaces such as walls (any thickness) partitions and the like including attached pillasters, buttress, plinth and string couress and the like with in all leads aand lifts as per the direction of the Engineer in Charge. |
| 13 | Flat surfaces such as soffits and suspended floors, roofs landing and the like: Floors etc up to 200 mm in thickness with in all leads aand lifts as per the direction of the Engineer in Charge. |
| 14 | Column, pillar & post upto floor two level with in all leads & lifts as per direction of Engineer - in charge. |
| 15 | Beams, cantilevers, Girders & lintels sides and siffits of beams, hounching cantilever girder not exceeding 1 mtr. Depth. |
| 16 | Providing and fixing MS Sheet Man hole cover with locking arrangement including lock, nuts & bolts & other fittings complete with in all leads & lifts as per the entire satisfaction & direction of the Engineer Incharge. |
| 17 | Providing & Laying cement concrete 1:6:12(1ccement :6 sand: 12 graded stone aggregate 40 mm nominal size) and curing complete excluding cost of form work in foundation and plinth with in all leads and lifts as per the directions of the Engineer in charge. |
| 18 | Providing andf laying cement concrete 1:5:10 (1 cement :5 sand : 10 graded stone aggregate 40 mm nominal size ) with 15% plum concrete and curing complete excluding cost of form work in retaining walls/breast walls,the size of plums shall usually be 150 mm to 300 mm as per H.P.P.W.D Specification. |
| 19 | Boulder filling behind R/wall & B/wall within all leads and lifts and as directed by the Engineer-in-charge. |
| 20 | Providing and fixing of Finolex pipe 50mm dia. In R/Wall including all re-fitting i/e elbowa, sockets etc. with in all leads aand lifts as per the direction of the Engineer in Charge. |
| 21 | Cutting in earth work and disposal of excavated earth up to a lead of 20 mtr. With in all leads and lifts as per the direction of the Engineer- in- charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents