Water Resources and Irrigation Government Departments Closing in 5 days TDR #56661834

Tender For annual repair & maintenance of Reoth Phanel In G.P Ram Nagar In Tehsil Kotkhai Distt. Shimla (H.P) (Sh: Plastering, Painting, Distempering, Soling, Plum Concrete Retaining Wall, Doors, Windows & Plinth Protection Wark At Stage 1St, 2Nd And

Issued by Government Departments · Shimla, Himachal Pradesh
Tender Value
13.61 Lakhs
Estimated cost
Bid Submission
03 Aug 2026
5 days left
EMD
27240
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Shimla → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for annual repair & maintenance of Reoth Phanel In G.P Ram Nagar In Tehsil Kotkhai Distt. Shimla (H.P) (Sh: Plastering, Painting, Distempering, Soling, Plum Concrete Retaining Wall, Doors, Windows & Plinth Protection Wark At Stage 1St, 2Nd And 3Rd Pump House). (Estimated Cost:- 13,61,633/-, Earnest Money Rs:- 27,240/- Time:- 3 Months.)

BOQ

Name of Work:- A/R & M/O Reoth Phanel in G.P Ram Nagar in tehsil Kotkhai Distt. Shimla (H.P) (SH: Plastering, painting, distempering, soling, plum concrete retaining wall, doors, windows & plinth protection wark at stage 1st, 2nd and 3rd pump house). (Estimated Cost:- 13,61,633/-, Earnest Money Rs:- 27,240/- Time:- 3 Months.)
Sl. No. Item Description
110mm cement plaster in single coat on fair side of brick/concrete walls for internal plastering up to floor two level including arrises, internal rounded angles, chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth with in all leads and lifts and entire satisfection of Engineer in Charge.
2Applying Birla white wall care putty over plaster surface after thoroughly brushing the surface free from mortar drops, dust, loose materials and other foreign matters sand papered smooth to give final matter finish to the surface complete with in all leads and lifts and entire satisfection of Engineer in Charge.
3Distempering (two coat) with oil bound washable distemper of approved brand and manufacture and of required shade on undecorated wall surface to give an even shade over and including a priming coat with distemper primer of approved brand and manufacture after thoroughly brushing the surface free from mortar droppings and other foreign matter and also including preparing the surface even and sand papered smooth Priming coat with distemper primer with in all leads and lifts and entire satisfection of Engineer in Charge.
4Providing in RCC work smooth finishing of the exposed surface with cement mortar 1:3 (1 cement :3 sand) with in all leads and lifts and entire satisfection of Engineer in Charge.
5Providing wood work in frames of doors, windows, clerestory windows and other frames wrought, framed and fixed in position of 2nd class deodar wood with in all leads and lifts and entire satisfection of Engineer in Charge.
6Supplying & fixing glass panes with putty and nails including removal of broken glass panes wherever necessary. Plain glass (5.5 mm thick) with in all leads and lifts and entire satisfection of Engineer in Charge.
7Providing & fixing panelled glazed or panelled & glazed shutters for doors windows and clerestory windows including black enamelled iron butt hinges with necessary screws in 2nd class deodar wood (50 mm thick) with in all leads and lifts and entire satisfection of Engineer in Charge.
8P/F wire gauge shutters using galvanised M.S. wire gauge of I.S. gauge designation 85G. with wire of dia 0.56mm for doors, windows with in all leads and lifts and entire satisfection of Engineer in Charge.
9Painting one coat (excluding priming coat) on priously painted wood and wood based surfaces, with enamel paint ,to give an even shade including cleaning the surface of dirt, dust and other foreign matter,sand papering and stopping. (With enamel paint other than white) with in all leads and lifts and entire satisfection of Engineer in Charge.
10Providing & fixing MS Handle with necessary screws complete 100 mm
11Providing & fixing MS Sliding Door Bolts with necessary screws complete. ( 250x16mm)
12Providing & fixing MS window stay with in all leads and lifts and entire satisfection of Engineer in Charge.
13Providing & fixing M.S. Tower bolts (Barrel type) 150x10mm
14Providing & fixing oxidized M.S single acting spring hinges with necessary screws etc. complete. with in all leads and lifts and entire satisfection of Engineer in Charge.
15Steel work in single sections including cutting, hoisting, fixing in position and applying a priming coat of red lead paint in R.S. Joists,channels, angles, tees etc. with in all leads and lifts as directed by the Engineer Incharge.
16Applying priming coat over new steel & other matel surface after and including preparing the surface by thoroughly cleaning oil,grease, dirt and other foreign matter landscoured with wire brushes fine steel wool scrapers and paper complete with in all leads and lifts and entire satisfection of Engineer in Charge.
17Painting two coats (excluding priming coat)on new steel and other metal surface with enamel paint brushing to give an even shade i/c cleaning the surface of all dirt and other foreign matter with in all leads and lifts and entire satisfection of Engineer in Charge.
18Precast Terrazzo tiles 20mm thick with marble chips of specified size in skirting and risers of steps not exceeding 30 cm in height on 10mm thick cement plaster 1:3 (1cement 3 Sand) jointed with neat cement slury mixed with pigment to match the shade of tiles (wherever required) including rubbing & polishing with tiles of folowing Shade Silver Gray with in all leads and lifts and entire satisfection of Engineer in Charge.
19Providing plinth protection 50mm thick in cement concrete 1:3:6 (1: cement: 3 sand: 6 graded stone aggregate 20mm N/S) with in all leads and lifts and entire satisfection of Engineer in Charge.
20Excavation in foundations, trenches etc., in earth work. lift upto 1.5 metres stacking the excavated soil not more than 3 metres clear from the edge of the excavation and then returning the stacked soil in 15cm. layers, when required into plinths sides of foundations etc. consolidating eac deposited layer by ramming and watering and then disposing of all surplus excavated earth as directed within a lead of 20 metres. with in all leads and lifts and entire satisfection of Engineer in Charge.
21Stone soling properly hand packed filling interestices with spalls and consollidating. with in all leads and lifts and entire satisfection of Engineer in Charge.
22Cement concrete flooring CC 1:2:4 (1cement:: 2 sand : 4 graded stone aggregate 20mm size) laid in one layer with floating coat neat cement. (40mm thick)and curing complete with in all leads and lifts and entire satisfection of Engineer in Charge.
23Applying priming coat over new wood and wood based surface after and including preparing the surface by thoroughly cleaning oil,grease, dirt and other foreign matter with in all leads and lifts and entire satisfection of Engineer in Charge.
24Providing & Laying cement concrete 1:6:12(1ccement :6 sand: 12 graded stone aggregate 40 mm nominal size) and curing complete excluding cost of form work in foundation and plinth with in all leads and lifts as per the directions of the Engineer in charge.
25Providing andf laying cement concrete 1:5:10 (1 cement :5 sand : 10 graded stone aggregate 40 mm nominal size ) with 15% plum concrete and curing complete excluding cost of form work in retaining walls/breast walls,the size of plums shall usually be 150 mm to 300 mm as per H.P.P.W.D Specification.
26Providing from work steel plates 3.15 mm thick welded with angle iron in frame 30x30x5 mm so as to give a fair finish i/c centering, shuttering, strutting and propping etc. with wooded battens & ballies, height of propping and centring below supporting floor to ceilling not exceeding 4 meters and removal of the same for in situ reinforced concrete and plain concrete work with in all leads aand lifts as per the direction of the Engineer in Charge.
27Vertical surfaces such as walls (any thickness) partitions and the like including attached pillasters, buttress, plinth and string couress and the like with in all leads aand lifts as per the direction of the Engineer in Charge.
28Providing and fixing of Finolex pipe 50mm dia. In R/Wall including all re-fitting i/e elbowa, sockets etc. with in all leads aand lifts as per the direction of the Engineer in Charge.
29Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable complete in all respect. \\"Group-C\\"
30Wiring for 3pin 5/6 amp socket outlet point on swich board in (surface/recessed PVC wiring system) and 5/6 amp tumbler piono type switch earthing the 3 pin painting etc as required with in all leads & lifts complete.
31Wiring for power plug with (2x4 Sq.mm) PVC insulated, heat resistant flame retardant(HRFR) and low smoke single core(flexible)copper conductor cable in surface/recessed PVC conduit along with 1 No. 4 Sq.mm. HRFRLS/PVC insulated sigle core copper conductor cable for earthing as required including carriage of material with in all leads & lifts complete.
32Wiring for light plug with (2x1.5 Sq.mm) PVC insulated, heat resistant flame retardant(HRFR) and low smoke single core(flexible)copper conductor cable in surface/recessed PVC conduit along with 1 No. 1.5Sq.mm.HRFRLS/PVC insulated sigle core copper conductor cable for earthing as required including carriage of material with in all leads & lifts complete.
33Wiring for circuit/sub-main with 2x10 Sq. mm size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required including carriage of material with in all leads & lifts complete.
34Supplying and fixing metal box of 180mmx100mmx60mm deep (nominal size) on surface/recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 3 pin 15/16 amps socket outlet and 15/16 amps, piano type switch, connections, ainting etc. as required..
35Supplying and erection of floor mounted fixed type metal frame work/boards of welded construction for switch gear mounting fabricated with M.S. angle iron (50 mm x 50 mm x 6 mm thick) of suitable dimensions with supporting members grouted 23cm underground and frame work covered with 3mm thick M.S. sheet from top to a given height, with M.S. angle iron / 50mmx50mmx 6mm thick welded on the back and grouted into the back wall complete with painting and bonding to the existing earth as required with in all leads & lifts complete.
36Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wireset, neutral link, earth bar, din-bar, detachable gland Pite, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required with in all leads & lifts complete. Double door-8 way
37Supplying and fixing 63Amp rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required with in all leads & lifts complete. Cat. A
38Supplying and fixing 63 amp rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required with in all leads & lifts complete Cat. A
39Supplying and fixing 5 to 32 amp rating 240 volts \\"L\\" series MCB of single pole in the existing MCB DB complete with connection, testing and commissioning etc as required with in all leads & lifts complete.
40Providing, Installation, testing and commissioning of prewired flourscent tube fitting 1x40 watt box type Cat A i.e. Bajaj make complete with balast starter and capacitor but excluding flourscent tube rod suitable to operate on 240volt single phase AC supply directly on surface with copper wiring as required complete as per direction of the Engineer-in-charge.
41Supplying and laying 6 SWG G.I. wire on surface / recess for loop earthing as required complete as per direction he Engineer-in-charge.
42P/F street light fixture 40watts 4 feet long complete with choke starter i/c connection complete as required complete as per direction of the Engineer-in-charge.
43Providing and fixing of approved brand geyser of 25 leters i/c all necessary accessories complete.
44Providing and installing of Water Tank 1000 Lirs with all fittings as per direction of the Engineer-in-charge.
45Providing & fixing Viterous China wash water closet (European type WC pan) with integral \\"P' or 'S' trap Vc jointing the trap with soil pipe in cement mortar 1:1 (1cement: 1 sand) (seat and cover to be mensured and paid for separately):- Ordinary closet -Vitreous China water pattern-l - in white colour (Hindware Cera make.
46P/Fixing PTMT coloured/white high density/poly properly 10 ltrs. Cap. Full flush Low level flushingCistern. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56661834
AUTHORITY Government Departments
TENDER VALUE 13.61 Lakhs
LAST DATE 03-08-2026
Authority
Authority Name Irrigation And Public Health Department
Work Description Tender for annual repair & maintenance of Reoth Phanel In G.P Ram Nagar In Tehsil Kotkhai Distt. Shimla (H.P) (Sh: Plastering, Painting, Distempering, Soling, Plum Concrete Retaining Wall, Doors, Windows & Plinth Protection Wark At Stage 1St, 2Nd And 3Rd Pump House). (Estimated Cost:- 13,61,633/-, Earnest Money Rs:- 27,240/- Time:- 3 Months.)
Basic Detail
Tender No JBL-SML-09-718
Bidding Type Tender
Location
City Shimla
State Himachal Pradesh
Key Dates
Publish Date 25 Jul 2026
Submission Date 03 Aug 2026
Open Date 03 Aug 2026
Finance
Tender Value 13.61 Lakhs
Tender Fee 500
EMD 27240
Exemption Not Available
Document List
737d96ed-ac04-4219-83ba-8218142fd178.html
BOQ_207472.xls
f6.pdf
f8.pdf
tc.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 25, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Aug 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

737d96ed-ac04-4219-83ba-8218142fd178.html

xls

BOQ_207472.xls

pdf

f6.pdf

pdf

f8.pdf

pdf

tc.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender