Tender For Repair / Replacement Of Sewage Line, Drainage System Boundary Wall , Fencing ,Barbed Wire And Concertina Coil , Cleaning Of Pvc Over Head Tank , Periodical Services And Certain Miscellaneous B/R Repairs At Icgs Vijay Nagar , Panchu Tikrey
Tender Overview
Project Description
Tender for Repair / Replacement Of Sewage Line, Drainage System Boundary Wall , Fencing ,Barbed Wire And Concertina Coil , Cleaning Of Pvc Over Head Tank , Periodical Services And Certain Miscellaneous B/R Repairs At Icgs Vijay Nagar , Panchu Tikrey Under Age B/R (P) Hut Bay.
BOQ
| Sl. No. | Item Description |
| 1 | NOTE: 1. The bidders/ contractors are advised to read tender documentts and all corrigendum/ amendments and General conditions of contracts before entry/ quoting the rates. |
| 2 | Taking out carefully precast RCC slabs of septic tanks, completely by emptying the liquid, semi solid and solid content including cleaning the inlet, outlet and getting out by using suction pump and filling the foul material in to the covered tanks attached to suction pump and removing, transporting and disposal of the same at a place earmarked for disposal of the foul material by Panchayat authorities to outside the ICGS Area and applying one coat of linseed oil complete for septic tank capacity 10 users to 100 users each, all as specified including cleaning the septic tanks with fresh water and bleaching powder and refixing the removed cover slab incl necessary cambering to edges as required in CM (1:4) and necessary touch-up with cement base paint all as directed by Engr-in-Charge. NOTE: Cubic content of filled up portion of septic tank shall be measured for payment purpose. |
| 3 | Taking out carefully the cover slabs of manholes of any size, depth and removing the sludge to a distance exc 250 m and n. exc 500 m and dumping eco friendly manner and cleaning the inside with fresh water and bleaching powder and placing the cover slabs back incl necessary cambering to edges as required in CM (1:4) and necessary touch -up with cement base paint all as directed by Engr-In-charge. |
| 4 | Cleaning with fresh water and bleaching powder, the blockages in sewer line of 100 to 150 mm dia pipes, in between manholes and passing rubber ball / sponge ball / similar means through the line to ensure cleaning of all blockage complete all as specified. |
| 5 | Excavation in trenches n. exe 1.5m wide & n. exe 1.5m depth for foundation etc and n.exe 10sqm on plan and getting out in Soft/Loose soil. |
| 6 | Returning filling in soil including spreading, levelling, watering & well ramming in layers n. exe 25 cm. |
| 7 | Removing excavated material n. exe 50m and depositing where directed at a level n. exe 1.50m above the starting point in Soil. |
| 8 | Demolition of concrete in ground floors (un reinforced) and paving n.exc. 15 cm thickness (below or above ground level) and including removal of rubbish/ demolished materials out of MD land complete all as specified and directed. |
| 9 | Demolition of PCC of any description and in any position not otherwise specifically provided for(un-reinforcement ) and removal of rubbish/ demolished materials out of MD land ,etc complete all as specified and directed. |
| 10 | Demolition of RCC of any description and in any position not otherwise specifically provided reinforced (reinforcement of cut as required to facilitate demolition etc) and removal of rubbish/ demolished materials out of MD land complete all as specified and directed. |
| 11 | Dismantling of cast iron/PVC pipes jointed in cement mortar and taking out of trenches, 150 mm nominal bore of pipe ,etc complete all as specified and directed. |
| 12 | M&L for PCC 1:3:6 type C2 (using 40mm graded aggregate) as in bed to drain pipes incl packing under and haunching against the sides of pipes after they are laid and tested for CI pipe 150mm bore ,etc complete all as specified and directed. |
| 13 | M&L for providing CI pipe (Centrifugally cast) in any length with (or) without ear laid in trenches and jointed, with cement joints in CM 1:1 or in floors, pipes of bore 150mm dia, incl necessary fixtures like bends, branch pieces ,etc complete all as specified and directed. |
| 14 | Cutting into existing manholes for for removing existing branch drain, making good to walling and rendering, cutting out branch channel, and making good benchings , for 150 mm dia bore of pipe ,etc complete all as specified and directed. |
| 15 | S & F in repairs 110mm bore PVC(SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors including taking out old pipes complete all as specifed and as directed.. |
| 16 | S & F mild steel TMT bars 10 mm dia over, cut to length, bent to shape required including crancking bending spirally for hooping for col hooking ends and binding with and including mile steel wire non less than 0.9 mm dia securing with clips in quality complete all as specified and directed. |
| 17 | All as per item No 15 here in before but 6mm to 8mm dia quality confirming complete all as spd and directed. |
| 18 | M & L providing precast cement concrete 1:2:4, Type B-1 (20 mm graded aggregate) as in cover slabs (for manholes etc) and similar articles with plain faces set in cement mortar 1:4. Including demolition of reinforced cement concrete complete All as specified and directed by Engr-in-charge. |
| 19 | Dismantling wrought iron or mild steel work of any description not otherwise provided for etc complete all as specified and and as directed |
| 20 | Supply and fix joist, channel, angle or tee sections, fixed independently , without connection plate etc cut to ordinary length within 20mm of the length conforming to Fe 410-W (Gde E-250 quality-B) complete all as specified and as directed |
| 21 | Material and labour for preparing the new steel or iron surfaces of any description over 10 centimeter width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer complete all as specified and as directed |
| 22 | S&F in repairs Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed. (each line wire to be measured) |
| 23 | S&F in repairs Punched Tape concertina Coil Of 600mm, openable/ strachable to 6 m round type, 51 spiral core wire, made out of 2.5 mm high tensile strength wire galvanised of tensile strength 1500mpa as specified in IS 4454 incl necessary wire or fixing coil on security/compound wall with Y shaped M/S angle complete all as specified and directed. |
| 24 | Demolition of brickwork or stone/boulder masonry / Block masonry, built in cement mortar including facing, dressed stone work and precast concrete all quoins, arches, pillars, coping etc but excluding ashlars articles complete all as specified and as directed |
| 25 | Taking down cement or cement lime mortar plaster, any description on brick or stone walls etc, including rackingout joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 26 | M&L for PCC 1:4:8 type D2 (using 40mm aggregate) as in foundations, filling and mass concrete complete all as specified and as directed. |
| 27 | M&L precast cement concrete solid block, Type C1 1:3:6 (Using 20 mm graded aggregate) block masonry with solid block, exc 10 cm in width and setting in CM (1:6) complete all as specified and as directed. |
| 28 | M & L cement concrete 1:3:6 Type C1 using 20mm graded stone aggregate as in coping, water troughs, channels inside manholes and the like including weathering, slightly rounded or chamfered angles and throating as directed |
| 29 | M & L providing, cement concrete Type B1 1:2:4 (20mm graded aggregate) as in copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, including necessary form work complete all as specified and as directed. |
| 30 | M & L rendering 15mm thick on surface of brick work/concrete surface in CM 1:4 etc complete all as specified and as directed. |
| 31 | Material and labour for rendering 10mm thick on brick work or concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement complete all as specified and as directed. |
| 32 | Material and labour for preparing the new plastered wall surfaces and applying two coats of white wash to match with the existing surface complete all as specified and as directed |
| 33 | M&L for 75 mm thick plain cement concrete 1:4:8 mix, Type D2 (using 40 mm graded stone aggregates) as in sub base to floor complete all as specified and as directed. |
| 34 | M&L for Machine pressed precast concrete interlocking paver block with grey cement and pigment (glossy finish) any shape & size conforming to IS 15658-2006 of 80 mm thickness, M-40 grade etc complete all as specified and as directed. |
| 35 | Spreading and leveling of Sand/ grit cushioning below interlocking tiles. Note: punned thickeness shall be measured for payment. |
| 36 | M&L for designer rubber moulded chequerred cement concrete tiles with mixture of grey and white cement in equal proportions with pigments of size 300 x 300 x 22mm thick and set and pointed in neat cement slurry in floors over a screed bed or bedding layer in CM 1:6, 15mm thick for laying floor finishes etc complete all as specified and as directed. |
| 37 | M&L for pre cast Machine pressed cement concrete 1:2:4 Type B-0 (using 12.50mm graded stone aggregate) as in kerbs stones and fixing all as per manufacturer instructions etc size shall be decided and directed by GE |
| 38 | Cleaning of PVC water tank at any height (on accessible/inaccessible roofs) by removing all scale, dirt, mud ,any foreign material and removing accumulated silt, other dirty substance, algae, fungus and other bacterial material from sides/bottom of tank by draining / pumping out water/sludge from bottom and other growth from wall/ floor by high pressure cleaning method with jet set, vacuum machine and again cleaning the tank with fresh water and disinfecting the tank Disinfecting by using UV radiator and approved chemical (chloriten). and capacity of tank exc 250 and n.exc 500 litre capacity, complete all as spd and directed. Note:- (i) Unit rate quoted shall include for necessary ladder and machinery for pressure cleaning and safety apparatus required for execution of work. (ii) Unit rate quoted shall include for writing the date of actual cleaning with white paint on black background to match with the existing. |
| 39 | All as item No-37 above but capacity of tank exc 500 and n.exc 1000 litre capacity, complete all as spd and directed. |
| 40 | Supply and fixed in repairs 1000 litres capacity rotational moulded polyethylene water storage tank of triple layer type(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I complete all as specified and as directed |
| 41 | Supply and fixed in repairs 500 litres capacity rotational moulded polyethylene water storage tank of triple layer type(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I complete all as specified and as directed |
| 42 | S and F in repair Ball valve of size 20 mm dia high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and directed |
| 43 | All as item No-41 above but of size 25 mm dia. |
| 44 | Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 20mm complete all as specified and directed. |
| 45 | S&F CPVC pipes, SDR 11, 20 mm outer dia of pressure rating 6kgf/sqcm conforming to IS-15778 with all CPVC fittings with such as brass elbow ,Tee, bends, unions ,sockets ,Threaded Adaptor and end pieces etc to receive fittings and fixed with solvents fixed to walls / ceiling with all clamps in Shafts/ducts with all necessary scaffolding to fix the pipes and testing the joints under prescribed pressure etc complete all as specified and as directed. |
| 46 | Supply and fixed in repairs 15 mm dia bib tap of standard PTMT of any colour screwed for iron pipe minimum weight 90 grams complete all as specified and as directed. |
| 47 | Supply and fixed in repairs 15 mm dia Stop valve of standard PTMT of any colour screwed for iron pipe minimum weight 90 grams complete all as specified and as directed. |
| 48 | S & F in repairs anodized aluminium alloy powder coated curtain rod 19 mm dia of standard thickness with fixing brackets, stops, rollers etc complete all as directed. |
| 49 | Supply and fix in repairs door closer, hydraulically regulated, aluminium body(extruded section body) designation No 2 universal type (ISI marked), suitable for shutters of 701 to 850 mm width of weight between 36 to 60 Kilo gram fixed complete all as specified and as directed |
| 50 | Supply and fix in repairs 140 mm long double legged door stopper of aluminium anodized with rubber shoe, nut (2 each on one stopper) with spring complete all as directed complete all as specified and as directed |
| 51 | Hacking out old broken glass (any thickness, size, quality or description) from wooden surface concrete or brick surrounds. Glazed with putty or fixed with beads all as specified. |
| 52 | S & F sheet glass 3mm thick ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane and all as specified. |
| 53 | S & F sheet glass 3mm thick ordinary quality and glazing with oil putty in square but exceeding 0.5 Sqm in each pane and all as specified. |
| 54 | S & F figured glass pin head type 3mm thick ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane and all as specified. |
| 55 | S&F in repairs Stainless steel wire cloth.0.36mm nominal dia of wire and average width of aperture1.40mm and fixed with stainless steel wire staples complete all as specified and as directed |
| 56 | Supply and fix in repairs 300 mm long mild steel helical door ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed. |
| 57 | Taking down steel/aluminium windows/ventilator/Doors complete with frames and shutters (without taking off the shutters) of area not exc 2.00 sqm complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 58 | Taking down steel/aluminium windows/ventilator/Doors complete with frames and shutters (without taking off the shutters) of area not exc 2.00 sqm complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender