Tender For Repair & Replacement Of Internal Electrification Fitting & Fixtures, Renewals Of Wiring, Bldg Security Lights, Distribution Boards And Connected Works Including Day To Day Services In Tech Area At Af Stn Thanjavur.
Tender Overview
Project Description
Tender for Repair & Replacement Of Internal Electrification Fitting & Fixtures, Renewals Of Wiring, Bldg Security Lights, Distribution Boards And Connected Works Including Day To Day Services In Tech Area At Af Stn Thanjavur.
BOQ
| Sl. No. | Item Description |
| 1 | Please Enable Macros to View BoQ information |
| 2 | S&F in replacement Flame Proof switch rotary type alongwith knob in existing LM6 housing of capacity 6 amps complete all as specified and as directed. |
| 3 | S&F in replacement Flame Proof socket fixed type in existing LM6 housing of capacity 6 amps complete all as specified and as directed. |
| 4 | S&F in replacement Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth complete all as specified and as directed. |
| 5 | Dismantling and taking out Flame Proof tube light fitting and taking out old unserviceable flurescent tube light fitting and S&F new LED tube light fitting with electronic driver of capacity 20 watt and refixing in position complete all as specified and as directed. |
| 6 | Dismantling and taking out high bay Flame Proof LED light fitting and taking out old unserviceable electronic drivers and S&F new electronic PCB (Printed circuit board) of capacity 150 watt and refixing in position complete all as specified and as directed. |
| 7 | Dismantling and taking out high bay Flame Proof LED light fitting and taking out old unserviceable LED Panel and S&F new LED Panel of capacity 150 watt and refixing in position complete all as specified and as directed. |
| 8 | Dismantling and taking out high bay Flame Proof LED light fitting and taking out old unserviceable Surge Protection Divice and S&F new Surge Protection Divece of capacity 150 watt and refixing in position complete all as specified and as directed. |
| 9 | S&F in replacement high bay 150 Watt LED floodlight made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection complete all as specified and as directed. |
| 10 | Taking down carefully old aluminium/copper point wiring for one light, socket or power etc incl all fitings such as switches sockets, holders, light fittings, fan regulators etc and making good the disturbed surface of wall ceiling complete all as specified and as directed. |
| 11 | M&L Flame Proof Point wiring complete with 2.5 Sq mm PVC insulated cable with copper conductor 1100 Volts grade, multistranded flame retardant low smoke (FRLS) in in existing stove enamelled steel conduit of 20 mm dia including provn of 2.5 Sqmm multistranded copper conductor cable PVC insulated unsheathed as earth continuinity cable for one light point controlled by one switch complete all as specified and as directed. |
| 12 | M& L Point wiring with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade multi stranded copper conductor drawn through and including suitable size Non metallic rigidPVC conduit and all conduit accessories (concealed) and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuity conductor including branded Modular Metal box concealed in walls with suitable Modular plate with outer cover fixed with suitable screws for one switch complete all as specified and as directed. |
| 13 | Description all as per srl item No 11 here-in-before but for One fan point controlled by one switch and regulator complete all as specified and as directed. |
| 14 | Description all as per srl item No 11 here-in-before but for One socket outlet 3 pin 5 amps on same board complete all as specified and as directed. |
| 15 | Description all as per srl item No 11 here-in-before but for One socket outlet 3 pin 5 amps on independent board complete all as specified and as directed. |
| 16 | Description all as per srl item No.11 here-in-before above but with 4 sq mm cable for one 3 pin 15 amps switch socket outlet on independent board with 4 sq mm cable for earth wire drawn through existing 20mm dia PVC conduit complete all as specified and as directed. |
| 17 | M&L point wiring with 1.5 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core copper cable working voltage 1100 volts grade conforming to IS-694 with multistranded copper conductor flame retardant low smoke (FRLS) in including PVC rigid non metallic 20 mm PVC casing caping (double Lock) including PVC polycarbonate / PVC / rectangular block / box of suitable size fixed by means of brass machine screw and cap washer including size 1.5 sqmm (nominal cross sectional area) PVC insulated unsheathed single core multistranded copper conductor cable as earth continuity conductor connected to main switches / DBs or common earth dolly complete all as specified and as directed. |
| 18 | Description all as per srl item No 16 here-in-before but for one ceiling fan / Exhaust fan point, controlled by one way switches 5/6 Amps complete all as specified and as directed. |
| 19 | Description all as per srl item No 16 here-in-before but for one 3 pin socket outlet point, 5/6 Amps on the independent board complete all as specified and as directed. |
| 20 | Description all as per srl item No 16 here-in-before but for one 3 pin socket outlet point, 5/6 Amps on the same board with other switches complete all as specified and as directed. |
| 21 | Description all as per item No 16 here-in-before but for point wiring with 4 Sq mm (nominal cross sectional area) single core stranded copper conductor for one switch socket outlet point, 15/16 amps on the independent board complete all as specified and as directed. |
| 22 | S&F in replacement Lamp holder, insulated body, with back plate suitable for batten fittings/pendent fittings white / ivory finish complete all as specified and as directed. |
| 23 | S&F in replacement Switch piano flush button, white/ivory finish, 5/6 amps, single pole, one way complete all as specified and as directed. |
| 24 | S&F in replacement Bell/buzzer push 5/6 amps, flush type, white/ivory finish complete all as specified and as directed. |
| 25 | S&F in replacement Ding dong bell, AC, Single pole, 220/240 Volts, white/ivory finish, surface type complete all as specified and as directed. |
| 26 | S&F in replacement Switch socket combination, 2 and 3 Pin, 5/6 amps, multipurpose, flush, non shutter, non inter locking type white/ ivory finish complete all as specified and as directed. |
| 27 | S&F in replacement Switch socket combination, 2 in 1, 6 pin, 5/6 amps and 15/16 amps multipurpose, white/ivory finish, flush non shutter non inter locking type complete all as specified and as directed. |
| 28 | M&L switch modular 1 way 6 amps 1 module complete all as specified and as directed. |
| 29 | M&L switch modular 1 way 16 amps 1 module complete all as specified and as directed. |
| 30 | M&L switch modular 2 way 6 amps 1 module complete all as specified and as directed. |
| 31 | M&L bell push modular 1 way 6 amps 1 module complete all as specified and as directed. |
| 32 | M&L Socket 6 amps modular 2/3 pin 2 module complete all as specified and as directed. |
| 33 | M&L Socket 16 amps modular 2/3 pin 2 module complete all as specified and as directed. |
| 34 | M&L fan step regulator modular 120 watt 2 module complete all as specified and as directed. |
| 35 | M&L modular white cover with frame 1 module complete all as specified and as directed. |
| 36 | M&L modular white cover with frame 3 module complete all as specified and as directed. |
| 37 | M&L modular white cover with frame 4 module complete all as specified and as directed. |
| 38 | M&L modular white cover with frame 6 module complete all as specified and as directed. |
| 39 | M&L modular white cover with frame 8 module complete all as specified and as directed. |
| 40 | M&L modular metal flush box 1/2 module complete all as specified and as directed. |
| 41 | M&L modular metal flush box 3 module complete all as specified and as directed. |
| 42 | M&L modular metal flush box 4 module complete all as specified and as directed. |
| 43 | M&L modular metal flush box 6 module complete all as specified and as directed. |
| 44 | M&L modular metal flush box 8 module complete all as specified and as directed. |
| 45 | S&F Sheet metal enclosure for 2 way Distribution Boards (DB’s), single door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB\\"S/lsolators after and including taking down old DB with MCB complete all as specified and as directed. |
| 46 | S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, single pole & neutral with 200 amps rated bus bar, IP-43 protection suitable for fixing MCB\\"S/lsolators after and including taking down old DB with MCB complete all as specified and as directed. |
| 47 | S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole and neutral with 200 amps rated bus bar, IP-43 protection suitable for fixing MCB\\"S/lsolators after and including taking down old DB with MCB complete all as specified and as directed.(Make : Legrand cat No 507611 or equivalent & specified in PS). |
| 48 | S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, Triple pole & neutral with 200 amps rated bus bar, IP-43 protection suitable for fixing MCB\\"S / lsolator’s after and including taking down old DB with MCB complete all as specified and as directed. (Make : Legrand cat No 507670 or equivalent specified in PS). |
| 49 | S&F Sheet metal enclosure for TPN DBs VTPN 4 way Distribution Boards (DB’s), double door, Tripple pole & neutral with 250 amps rated bus bar, IP-43 - IK 09 protection suitable for fixing MCB\\"S / lsolator’s after and including taking down old DB with MCB complete all as specified and as directed. (Make : Legrand cat No 507745 or equivalent specified in PS). |
| 50 | S&F Sheet metal enclosure for TPN DBs VTPN 8 way Distribution Boards (DB’s), double door, Tripple pole & neutral with 250 amps rated bus bar, IP-43 - IK 09 protection suitable for fixing MCB\\"S / lsolator’s after and including taking down old DB with MCB complete all as specified and as directed. (Make : Legrand cat No 507747 or equivalent specified in PS). |
| 51 | S&F in replacement Ceiling rose, surface Bakelite, large type, 220/240 volts, three terminals, white/ivory finish complete all as specified and as directed. |
| 52 | S&F fan regulator electronic type suitable for 300 Watt (heavy duty) type 250 V, AC for ceiling fan complete all as specified and as directed. |
| 53 | Dismantling and taking down Ceing fan, sealing cable end, dismantling blades and removing fan and blades to store complete all as specified and as directed. |
| 54 | S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed. |
| 55 | Dismantling and taking down Exhaust Fan, sealing cable end, dismantling blades and removing fan and blades to store complete all as specified and as directed. |
| 56 | S&F exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, frame and louvers complete all as specified and as directed. |
| 57 | S&F in replacement fan capacitor 3.15 MFD complete all as specified and as directed. |
| 58 | S&F in replacement LED ceiling lights 18 watt complete all as specified and as directed. |
| 59 | M&L sub main wiring with 2 run of 4 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core flame retardant low smoke cable (FRLS) of working voltage 1100 volts grade with stranded copper conductor including one run of 4 Sqmm (nominal cross sectional area) PVC insulated unsheathed flame retardant cable (FR) with stranded copper conductor as continuous earth wire connected to main switches DBs or in common earth dolly drawn with 20 mm dia PVC rigid non- metallic conduit including taking down / dismantling old sub main wiring including old conduit / casing capping / wooden batten etc of any description complete all as specified and as directed. Note : Two runs of power conductor and one run of earth conductor with PVC conduit will be measured as one RM. |
| 60 | M&L sub main wiring with 2 run of 6 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core flame retardant low smoke cable (FRLS) of working voltage 1100 volts grade with stranded copper conductor including one run of 6 Sqmm (nominal cross sectional area) PVC insulated unsheathed flame retardant cable (FR) with stranded copper conductor as continuous earth wire connected to main switches DBs or in common earth dolly drawn with existing 20 mm dia PVC rigid non- metallic conduit after and including taking down / dismantling old sub main wiring including old conduit / casing capping / wooden batten etc of any description complete all as specified and as directed. Note : Two runs of power conductor and one run of earth conductor with PVC conduit will be measured as one RM. |
| 61 | M&L Flame Proof sub main wiring with 2 run of 6 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core flame retardant low smoke cable (FRLS) of working voltage 1100 volts grade with stranded copper conductor including one run of 4 Sqmm (nominal cross sectional area) PVC insulated unsheathed flame retardant cable (FR) with stranded copper conductor as continuous earth wire connected to main switches DBs or in common earth dolly drawn in existing stove enamelled steel conduit of size 20mm after and including taking down / dismantling old sub main wiring including old conduit / casing capping / wooden batten etc of any description complete all as specified and as directed. Note : Two runs of power conductor and one run of earth conductor with PVC conduit will be measured as one RM. |
| 62 | S&F in replacement of wall mounted LED light 20 Watt LED, 6500K with decorative ultra slim square profile LED lighting fixture with extruded polycorbonate environmental friendly energy efficient of Havells Cat Part.No: LHEXAWP7UN1W020 or Equivalent specified in PS complete all as specified and as directed. |
| 63 | S&F in replacement of wall mounted LED light 10 Watt LED, 6500K with decorative ultra slim square profile LED lighting fixture with extruded polycorbonate environmental friendly energy efficient of Havells Cat Part.No: LHEXACP7IN1W010 or Equivalent specified in PS complete all as specified and as directed. |
| 64 | S&F in replacement 36 Watt LED ceiling light fitting suitable for arm strong /grid ceiling with electronic driver complete with all accessories internally pre-wired and including connecting up with twin core copper conductor cable with suitable size of Havells Cat Part No. LHEBAEP7IW1W036 or equivalen specified in PS complete all as specified and as directed. |
| 65 | S&F in replacement 15 Watt LED ceiling light fitting suitable for arm strong /grid ceiling with electronic driver complete with all accessories internally pre-wired and including connecting up with twin core copper conductor cable with suitable size complete of Havells Cat Part LHEBAEP7IZ1W015or equivalent specified in PS complete all as specified and as directed. |
| 66 | S&F in replacement of 10W IP66 environmental friendly, ultra modren energy saving surface mounted decorative bulk head back lit LED luminaire comprising of high briteness LEDs and making necessary connections of Crompton Part. No CIS-306-10-57-SL-DP-NBK or Equivalent specified in PS complete all as specified and as directed. |
| 67 | S&F in replacement decorative wall mounting brushed nickel finish fixture with opal glass diffucer suitable with 9 watt LED lamp B22 base , of Havells cat part No : LHFOAJE1TZ1I060 or equivalent specified in PS complete all as specified and as directed. |
| 68 | S&F in repairs MCB, Tripple pole & neutral, 63 amps, 415 volts, ‘C’ curve, 10 KA of Legrand Cat No 408683 or equivalent specified in PS complete all as specified and as directed |
| 69 | S&F in repairs MCB, Single pole & neutral, 6 to 32 amps, 240 volts, ‘C’ curve, 10KA of Legrand Cat No 408609 to 408617 or equivalent specified in PS complete all as specified and as directed |
| 70 | S&F in repairs MCB, Single pole & neutral, 40 to 63 amps, 240 volts, ‘C’ curve, 10KA of Legrand Cat No 408618 to 408620 or equivalent specified in PS complete all as specified and as directed. |
| 71 | S&F in repairs MCB, Single pole, 6 to 32 amps, 240 volts, ‘C’ curve, 10 KA of Legrand Cat No 408587 to 408595 or equivalent specified in PS complete all as specified and as directed. |
| 72 | S&F in replacement MCCB 160 amps 4 pole 16 KA model DPX3 160 suitable for VTPN DBs of Legrand cat part No 420007 or equivalent specified in PS complete all as specified and as directed |
| 73 | S&F in replacement MCCB 100 amps 4 pole 16 KA model DPX3 160 suitable for VTPN DBs of Legrand cat part No 420007 or equivalent specified in PS complete all as specified and as directed |
| 74 | S&F in replacement LED bldg security light/street light 20 watt 6500K with best in class design and rebust heat sink along with class leading IP,IK and surge protections for long lasting performance of Havells cat part No LHETAVU7PA7J020 or equivalent specified in PS complete all as specified and as directed |
| 75 | Labour only for attending NO light /Earth fault / Loose connection complaints from technical area and disconnecting the wires/cables from terminal blocks and connection to feeder and cutting/removing the damaged worn out conductor/wires portion and reconnecting the cable to terminal box after rectifying the fault including testing complete all as specified and as directed.Note:Material used for serviceable condition will be measured seperately. |
| 76 | Labour only for attending NO light /Earth fault / Loose connection complaints from technical area and disconnecting the wires/cables from terminal blocks and connection to feeder and cutting/removing the damaged worn out conductor/wires portion and reconnecting the cable to terminal box after rectifying the fault including testing complete all as specified and as directed.Note:Material used for serviceable condition will be measured seperately. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender