Tender For Repair/Maintenance Of Mccb, Timer Switch Ht/Lt Ug Cable Water Supply Distribution Pipe Lines, Valve, Union Etc, Dg Set, Transformer, Lt Panel At Hut Bay Under Ge(P) North
Tender Value
17.50 Lakhs
Estimated cost
Bid Submission
15 Aug 2026
14 days left
EMD
35000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
South Andamans → Andaman And Nicobar Islands
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maintenance Of Mccb, Timer Switch Ht/Lt Ug Cable Water Supply Distribution Pipe Lines, Valve, Union Etc, Dg Set, Transformer, Lt Panel At Hut Bay Under Ge(P) North
BOQ
| Sl. No. | Item Description |
| 1 | NOTE: 1. The bidders/ contractors are advised to read tender documents and all corrigendum/ amendments and General conditions of contracts before entry/ quoting the rates. |
| 2 | Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth and getting out in in any type of soil all as directed by Engr - in- Charge. |
| 3 | Returning filling in , excavated soil including spreading, leveling and well ramming in layers not exc 25cms each any type of soil. |
| 4 | Removing the excavated materials not exc 50mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as directed by Engr - in- Charge. |
| 5 | M&L for sand cushioning by spreading in trenches fine dry river sand as in cable protection. Note: punned thickness shall be measured for payment |
| 6 | Supply and laying precast concrete cable cover class LV type-I, flat size 250mm x 150mm x 40mm laid in trenches all as specified. |
| 7 | Laying only precast concrete cable cover class LV type-I, flat size 250mm x 150mm x 40mm laid in trenches all as specified.Note :- Serviceable covers removed shall be relayed under this item. |
| 8 | Supply & Lay XLPE insulated, heavy duty 1100 volt grade electric LT UG cable with aluminum conductor of size 6 Sqmm 2 Core in trenches/along the wall/ including making all connections complete with lugs, suitable cable glands as required at site including taking down old cable complete as directed by Engr-in-Charge. |
| 9 | Supply & Lay XLPE insulated, heavy duty 1100 volt grade electric LT UG cable with multistranded aluminium conductor of size 10 Sqmm 4 Core in trenches /along the wall/ including making all connections complete with lugs, suitable cable glands as required at site and as directed by Engr-in-Charge. |
| 10 | Supply & Lay XLPE insulated, heavy duty 1100 volt grade electric LT UG cable with multistranded aluminium conductor of size 16 Sqmm 4 Core in trenches /along the wall/ including making all connections complete with lugs, suitable cable glands as required at site and as directed by Engr-in-Charge. |
| 11 | Supply & Lay XLPE insulated, heavy duty 1100 volt grade electric LT UG cable with multistranded aluminium conductor of size 35 Sqmm 3.5 Core in trenches/along the wall/ including making all connections complete with lugs, suitable cable glands as required at site and as directed by Engr-in-Charge. |
| 12 | Supply & Lay XLPE insulated, heavy duty 1100 volt grade electric LT UG cable with multistranded aluminium conductor of size 50 Sqmm 3.5 Core in trenches /along the wall/ including making all connections complete with lugs, suitable cable glands as required at site and as directed by Engr-in-Charge. |
| 13 | S & F in repairs out door heat shrink type end termination cable jointing kit for 11 KV (Earthed) grade cable 95 Sqmm |
| 14 | S & F in repairs out door heat shrink type stragight through cable jointing kit for 11 KV (Earthed) grade cable 95 Sqmm |
| 15 | M&L for Straight through heat shrink joint complete type LT XLPE cable upto 1.1 KV complete with all accessories. NOTE: Excavation & Earth work shall be measured & paid separately in respective item of this sch. |
| 16 | 4 Core 10/16/25 Sq mm. |
| 17 | 3 1/2 core 35/50 Sqmm |
| 18 | 3 1/2 core 70/95 Sqmm |
| 19 | M&L painting of Pre-stressed concrete pole upto bottom portion with two coat of Blue (Indian Coast Guard) (0.75M Above foundation) over a coat of red oxide primer & 02 Nos alternate layer of red and yellow colour self adhesive reflective tape of 100mm width & writing pole number on black background with white lettering after cleaning well the existing surface complete all as specified and directed. |
| 20 | M&L painting of LT octagonal pole upto bottom portion with two coat of Blue (Indian Coast Guard) (0.75M Above foundation) over a coat of red oxide primer & 02 Nos alternate layer of red and yellow colour self adhesive reflective tape of 100mm width & writing pole number on black background with white lettering after cleaning well the existing surface complete all as specified and directed. |
| 21 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as directed by Engineer in charge . |
| 22 | Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as directed by Engineer in charge . |
| 23 | Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. |
| 24 | Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as directed by Engr-in-charge |
| 25 | M&L for taking down old unsv and supply & lay 3 Core 1.5 Sq mm size multistranded copper conductor PVC unsheathed 650 / 1100 Volt Grade \ |
| 26 | Supply, fixing and connecting street light timer switch digital type having 24 hours to 7 days time setting astro type ( having longitude and latitude in memory) with 6 hrs battery backup complete with following accessories provisioned in factory made sheet metal box powder coated and fixing arrangement on pole/wall/ or in feeder pillar and dismantling unserviceable switch complete all as specified. :- |
| 27 | (a) MCB SPN 16 Amps, 415 volts. Make -2 No |
| 28 | (b) Digital timer having 24 hours to 7 days time setting with memory location. -1 NO |
| 29 | (c) Power contactor ML-3 three pole coil voltage 240 vMake (Leagrand/L&T) - 1 No |
| 30 | (d) Complete wiring with suitable size of copper wire including necessary thimbles. |
| 31 | Material & labour for opening cover of garden light checking connections, replacing of lamps LED type 5 Watts, 230 volt suitable for garden light fitting of Make: Crompton, Bajaj, Philips |
| 32 | M & L for Filtration and dehydration of transformer oil using filtration plant to remove moisture and carbon contents to achieve dielectric strength of oil not less than 50KV in 2.5 mm gap, Oil samples of each transformer are to be tested before and after filtration test, results to be recorded on a printed format and also painting the date of test on the equipment with synthetic enamel paint all as specified and directed and also including disconnecting the HT and LT cables and cleaning the bus bar surfaces and reconnecting the cables by providing copper washers, bolts, nuts, replacing of silica gel breather etc all as specified and directed. Please Enable Macros to View BoQ information |
| 33 | M & L for Filtration and dehydration of transformer oil using filtration plant to remove moisture and carbon contents to achieve dielectric strength of oil not less than 50KV in 2.5 mm gap, Oil samples of each transformer are to be tested before and after filtration test, results to be recorded on a printed format and also painting the date of test on the equipment with synthetic enamel paint all as specified and directed and also including disconnecting the HT and LT cables and cleaning the bus bar surfaces and reconnecting the cables by providing copper washers, bolts, nuts, replacing of silica gel breather etc all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 25, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 15, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysAug 20, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender