Project Description
Tender for Development Of Golf Course And Golf Facilities At Sector 24 Dwarka.Sub Head :Sitc Of Internal Electrical Installation At Kitchen Of Dwaka Golf Course Sector-24.
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated Group C(DSR2025, 1.3) |
| 2 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed Steel conduit alongwith 1 No. 4 sq. mm FRLSPVC insulated copper conductor single core cable for loop earthingas required. (DSR-2025,1.5) |
| 3 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed Steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.(DSR-2025,1.6) |
| 4 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.a) 4 X 16 sq. mm + 2 X 6 sq. mm earth wire (DSR-2025,1.7) |
| 5 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required. (DSR 2025,1.31) |
| 6 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. (DSR-2025,1.32) |
| 7 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutralbus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (DSR_2025)a) 6 way (4 + 18), Double door |
| 8 | b) 8 way (4 + 24), Double door |
| 9 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 way (4 + 24), Double door |
| 10 | 12 way (4 + 36), Double door |
| 11 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single pole (DSR-2025,2.10) |
| 12 | b) Double pole |
| 13 | c) Triple pole and neutral |
| 14 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. (DSR- 2025,2.11) |
| 15 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual currenl circuit breaker TPN having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 40 amps |
| 16 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. (DSR_2025_5.18) |
| 17 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.(DSR: 2025 1.17) a) 3x1.5 sq mm |
| 18 | b) 4X4 sq mm |
| 19 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagneticrelease and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel,making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. (DSR-2.2.14)125 A,36KA,FPMCCB |
| 20 | SITC of outdoor type Feeder pillar, cubical type fully compartmentalized made out of 2 mm thick CRCA Sheet having IP54 protection with canopy, pedestal mounted, suitable for use on 415V, 3 Phase, 4 wire, 50 HZ and complete with powder coated painting through seven-tank process facility for pricking and degreasing, of suitable size for accommodating the following component, including providing detachable gland plate of 3 mm thick for incoming and outgoing cables entry, erected on cement concrete foundation made, complete with painting, interconnections, earthing, provision for protection from rain dust, fixed on MS angle iron frame work of size 50 mm x50 mm x 6 mm (NS) 100 cm long legs out of which 50 cm duly grouted in cement concrete 1:2:4 (1 cement: 2 sand: 4 stone) aggregate etc complete as required.A) INCOMERi) 315 Amps 4 Pole MCCB 36 KA thermal magnetic based release(O/C & S/C) protection, spreader & ROH . - 1 No. ii) Digital Ammeter ,CL:1.0 - 1 No. iii) 300/5 amps CT CL:1.0 - 3 Nos.iv) CT's shorting links- 4 Nos. v) Digital Voltmeter CL:1.0 - 1 No.vi) R - Y , LED Type Indicating lamp - 2 No. vii) B, LED Type Indicating lamp -1 No.viii) 32 A neutral Link-1 No. ix) 2A SP MCB-6 Nos.x) ASS- 1 No. xi) VSS- 1No.B) BUSBARSi) 500 Amps TP&N Aluminium bus bars mounted on SMC supports.OUT GOINGi)3 Nos. 125A,36 kA, TPN MCCBii) 1 Nos. 63A,25 kA TPN MCCBiii) 1 nos 32 A DP iv) 4 nos 15/16A SP |
| 21 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. (DSR2025-1.32) |
| 22 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. (DSR-2025-1.20)25 mm |
| 23 | 32 mm |
| 24 | 40 mm |
| 25 | 20 mm |
| 26 | LED Batten light (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).24 -26watt |
| 27 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosedplug top along with 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chainedmetal cover for the socket out let and complete with connections, testing and commissioning etc. as required.(DSR -2025, 2.18) |
| 28 | Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosedplug top along with 20 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chainedmetal cover for the socket out let and complete with connections, testing and commissioning etc. as required.(DSR-2025,2.19 |
| 29 | Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosedplug top along with 30 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chainedmetal cover for the socket out let and complete with connections, testing and commissioning etc. as required.(DSR-2025,2.20) Please Enable Macros to View BoQ information 185400.0 1013100.0 79300.0 93718.0 158599.0 106696.0 107844.0 30300.0 50500.0 285976.0 50782.0 41500.0 35300.0 2239015.0 |
AI Tender Summary
Tender Timeline
Jul 25, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 31, 2026