Tender For Renovation Of Old Community Building To Develop As An Urban Health Center Ayushman Arogya Mandir At Arjundih Chhattarpur
Tender Value
24.18 Lakhs
Estimated cost
Bid Submission
10 Aug 2026
10 days left
EMD
48366
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Palamu → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Renovation Of Old Community Building To Develop As An Urban Health Center Ayushman Arogya Mandir At Arjundih Chhattarpur
BOQ
| Sl. No. | Item Description |
| 1 | Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. |
| 2 | Providing 6mm thk cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. |
| 3 | Dismantling old plaster and pointing in cement or lime and raking out joints to 15 mm. depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/l. |
| 4 | Dismantling Pucca brick or lime work including stacking serviceable material in countable stacks within 15 M lead and disposal of unserviceable materials with all leads all complete as per direction of E/l. |
| 5 | Dismentaling RCC work including do-. |
| 6 | Earthwork in excavation in foundation trench in ordinary soil incuding lead and lift do-do-all complete job. |
| 7 | Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick do-do-all complete job. |
| 8 | Providing degination 75A one brick flat soling joint filled with local sand including cost of watering taxex royalty -do-do-all complete job as per E/I. |
| 9 | Providing degination 75A Brickwork in C.M. (1:6) in Superstructure -do-do-all complete job as per E/I. |
| 10 | Providing and laying in position Plain cement concrete grade M15 (1:2:4) excluding the cost of centering shuttering finishing-All work upto plinth level. |
| 11 | Providing and laying in position specified grade of Reinforced cement concrete grade M20 (1:1.5:3) excluding the cost of centering shuttering finishing and reinforcement-All work upto plinth level. |
| 12 | Reinforcement cement concrete work in column and roof with M 20 (1:1.5:3) ratio.including centering shuttering reinforcement all work complete job. |
| 13 | Providing Tor steel reinforcement of 10mm,12mm,16mm dia bars as per approved design and drawing d0-do- |
| 14 | Centering Shuttering including strutting propping etc and removal of formwork for Column. |
| 15 | Centering Shuttering including strutting propping etc and removal of formwork for Beams. |
| 16 | Centering Shuttering including strutting propping etc and removal of formwork for Roofs. |
| 17 | Making plinth protection 50mm thik of cement concrete 1:3.:6 (1 cement :3 coarse sand :6 grade stone aggregate 20 mm normal size) over 75 mm thik ded dry brick ballast 40mm normal size well rammed and cansoldiated and grouted with fine sand including nessesary excavation leving and dressing & finishing the top smooth. |
| 18 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed withwater proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofingcement compound @ 0.253 kg/sqm.(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibrecloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with waterproofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed toair cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cmon parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately.For the purpose of measurement the entire treated surface will be measured. |
| 19 | Supplying, fitting and fixing 35mm thick solid core type decorative double leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with Aluminium fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/l. |
| 20 | Suppling, fitting and fixing good quality, well dressed and well seasoned sal wood work in chaukhat in doors, windows, skylight, fanlights and celetial windows openings, including wedge over clamps all complete including application of two coats of wood preservative of approved quality on the surface butting walls and lintels all complete as per building specification and direction of E/l |
| 21 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285 fixing with dash fasterners of required dia and size, including necessary filling up the gaps at junctions i.e. at top, bottom and sides with required DPDM rubber/neoprene gasket etc., aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/panelling C.P. brass/stainless steel screws, all complete as per architetural drawings and the directions of Engineer-in-charge (Glazing, panelling and dash fasteners to be paid for separately)Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) |
| 22 | Providing and fixing glazing in aluminium door, windows, ventilators, shutters and partitions etc, with EPDM rubber/neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge (cost of aluminium snap beading shall be paid in basic item)With float glass panes of 8.0 mm thickness. |
| 23 | Structural steel work in single section ,fixed with or without connecting plate,including cutting,hoisting,fixing in position and applying a primer coat of approved steel primer all complete |
| 24 | Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direciton of E/l. |
| 25 | Providing and fixing bright finished brass tower bolts (barrel type) withnecessary screws etc. complete:250x10 mm |
| 26 | 150x10 mm |
| 27 | 100x10 mm |
| 28 | Providing and fixing bright finished brass door latch with necessaryscrews etc. complete 300X16X5 mm |
| 29 | Providing and fixing ISI marked oxidised M.S. sliding door bolts withnuts and screws etc. complete,300x16 mm |
| 30 | Providing& Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S including cost of adhesive of approved quality:1.0 mm thick |
| 31 | Providing degination 75A one brick on edge solling do-do- all. |
| 32 | Providing 50 mm thick cement concrete flooring (1:2:4) with 20 to 6mm.size graded stone chips finished with flooring coat of neat cement in panels-do-. |
| 33 | Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm . |
| 34 | Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm . |
| 35 | Providing two coats of dry distemper of approved shade and make over a primer coat of washing over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding, washing of floors and taxes all complete as per building specification and direction of E/l. |
| 36 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 37 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/ 10 sqm overand including priming coat of exterior primer applied @ 2.20kg/ 10 sqm) |
| 38 | Providing and fixing 19mm thick both side balancing laminationfactory pressed BWP grade marine ply as per IS 710 of approved brand boxes, shelves,racks, almirah, cupboard and drawer etc. including necessary nails,screws etc. complete as per direction of Engineer-in-charge. |
| 39 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. |
| 40 | Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site. Basic RatesFrom 0 - 50 meter |
| 41 | From 51 - 125 meter |
| 42 | Supply of 200mm dia X 2.00m long UPVC casing pipe conferming to IS : 12818 : 2016 (CML No. 5543459) latest revision including carriage. |
| 43 | Supplying all materials, labours, equipments for lowering blue UPVC casing pipes as casing for protecting the sides from falling during the process of drilling all complete including carriage of materials to work site. |
| 44 | Supplying all tools, equipments and labour and doing washing, flushing and development of drilled tube well to give clean and clear water all complete as per direction of E/I. |
| 45 | Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump. Submersible pump set 100mm dia (with Polypropylene/ Noryl Impeller) up to 20 stages.2 HP |
| 46 | PVC/XLPE insulated PVC sheathed heavy duty, armoured electrical cable with aluminium conductor for working voltage up to and including 1100 volts.(Conforming to IS:1554, part-1)6sq.mm, 2 core. |
| 47 | 63 amp. Four pole, on load change over switch in sheet enclousre with side handle operation. |
| 48 | Medium density polyethylene pipe (MDPE pipe) in standard length with necessary Jointing material like mechanical connector i.e., thread/insert joint / quick release coupler joint / compression fitting joint or flanged joints confirming to ISO: 4427 : 1996,MDPE pipe of material grade PE-80 PN16 (dia in mm) 40mm |
| 49 | Polythene water storage tank of mark with cover and suitable locking system in double layer confirming to IS: 12701-1996 with latest revision. |
| 50 | Providing & fixing brass stop cock of approved quality all complete as per specification and direction of E/I.(A) Brass stop cock(c) 25 mm dia |
| 51 | (d) 32 mm dia |
| 52 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 mspacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.25 mm dia |
| 53 | Supplying, fitting and fixing viteous white glazed earthen ware I.W.C. Of parry Hindustan or any other I.S.S approved make with 100mm H.C.I. p trap 15 liters c.I pull and let go flushing cistern of names or other I.S.S. equivalent make , complete with all fittings.CI or CC brackets 32mm alkathene/PVC telescpope flush,pipe about 2 M long with one brass coupling and clams G.I. chain and pull including supplying and fixing a pair of vitreous white glazed earthen ware footrest to be fixed in floor 15mm C.I body brass spindle stope cock of weight not less than 50grams,15mm PVC connection pipe and 450 mm . long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all comlete as per specification and direction of E/l.(B) 580 mm long (b)12.5 lit. low level P.V.C. cistern |
| 54 | Supplying, fitting and fixing flat back or angular, lipped front viterous white glazed earthenware urinal of \\"Hindustan\\" \\" Parry\\" or any other approved I.S.S. make with all fittings with C.I. or R.S. brackets, standard size G.I. flush pipe with fitting clamps, 15 mm C.I. body brass spindle stop cock of approved quality weight not less than 400 grms. , 15 mm P.V.C. alkathene pipe 450 mm long with brass coupling at both ends and doing plumber joints including painting of exposed part with 2 coats of approved paint over a priming coat of red oxide, cutting wall and floor, making good the same etc. all complete as per specification and direction of E/l.(A) Flat back or standing corner ( 450 mm x 350 mm ) |
| 55 | Supplying, fitting and fixing viterous white glazed earthen ware wash hand basin of Parry or Hindustan or any other I.S.S. approved make supported on pointed c.l. or R.S. brackets 32m C.I. brass waste 15mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grms., 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/l. |
| 56 | Providing and fixing lead connection pipe with heavy quality brass coupling 2 Nos. at both ends etc. all complete as per specification and direction of E/l .(ii) 15 mm dia and 45 cm long |
| 57 | Providing and fixing N.P/C.P brass/P.V.C porcelain shower rose of 15mm inlet etc. all complete as per specification and direction of E/l.(c) 150 mm dia P V C shower |
| 58 | Providing and fixing male ended 15 mm dia brass bib cock of approved quality ( wt not less than 350 gms ) with extra socket all complete as per specification and direction of E/l . |
| 59 | Providing and fixing 15mm size C.P brass pillar cock (Weight not less than 350 gms) C.I body brass spindle pillar cock of approved quality as per spcification and direction of E/l.(b) C.I. body brass spindle |
| 60 | Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/l. Glass shelf with C.P brass rail i) 600 x 125 mm glass shelf complete |
| 61 | Mirrors of 4 mm thick plate glass bevelled edge mirror including C.P brass revolving fittings, 3 mm plywood board and C P hinges to fix with mirrori) 600x450 mm |
| 62 | i) C.P brass towel rail 20 mm x 600 mm with bracket container |
| 63 | ii) C.P brass shop dish container medium quality with screw and hinges etc. |
| 64 | (iii) C.P brass liquid shop container |
| 65 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(a) 100 mm dia |
| 66 | constructing brick masonary chamber for underground chloride c.i inspection chamber…..etc coplete as per engineer incharge |
| 67 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Singlesocketed pipes.110 mm dia |
| 68 | 75 mm dia |
| 69 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of size exceeding 95 sqmm but not exceeding 185 sq mm direct in ground including excavation, sand cushioning, protective covering and refiling the trench etc as required. |
| 70 | PVC / XLPE insulated PVC sheathed heavy duty, armoured electrical cable with aluminium conductor for working voltage up to 1100 volts. (Conforms to IS : 1554, part-1)120 sq mm, 3.5 core |
| 71 | Supplying and making cable route marker with cement concrete 1:2:4 (1cement: 2coarse sand : 4graded stone agreegate 20mm nominal size) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10 cm including inscription duly engraved as required. |
| 72 | Providing & fixing M.V. danger notice plate of 250 mm X 150 mm, made of mild steel, at least 2mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 73 | P/F G.I. lighting conductor finial :- providing and fixing of lighting conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 74 | P/F G.I. lighting conductor tape in horizontal run:- providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lighting conductor complete as required. |
| 75 | P/F G.I. lighting conductor tape in vertical run:- providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lighting conductor complete as required. |
| 76 | Reverting, sweating and soldering of copper / G.I. tape with another copper / G.I. tape, base of finial or any other metallic object as required. |
| 77 | Providing fixing testing joint made of 20 mm X 3 mm thick G.I. strip 125 mm long with 4 nos G.I. bolts. Nuts chuck nuts and spring washers etc. complete as required. |
| 78 | Earthing with copper plate 600mmx 600mmx 3mm thick including acessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.(but without charcoal or cock and salt) complete etc. as required. |
| 79 | S/L 8 SWG G.I. wire in ground :- Supplying and laying 8 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as required. |
| 80 | Providing & laying earth connection from earth electrode with 4mm dia copper wire in 15mm dia G.I. pipe from earth electrode, as required. |
| 81 | S/F rewireable double pole/TP&N switch disconnector:- Providing and fixing following DP/TP&N sheet metal switch disconnector fuse unit in the existing metal board with rewireable type fuses, including drilling holes in metal board. Making connection etc. as required.16 amps, double pole |
| 82 | Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubical panel board including drilling holes in cubical panel, making connections etc. as required.25 - 100 amps, 10 KVA fixed thermal setting |
| 83 | Providing and fixing following capacity bus bar chamber with 4 strips of length 300 mm made of copper suitable for following capacity complete with all accessories including connections, earthing the body etc. as required, 100 amps |
| 84 | Providing and fixing following capacity 2pole / 4 pole ON / OFF - load changeover switches with side handle operation, in sheet enclosoure in existing metal board including drilling holes in metal board, making connection, earthing the body etc. as required.32 amps, 2 pole |
| 85 | Providing and fixing following ways surface / recess mounting, vertical type 415 volts, TPN MCB DB of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incommer) as required.4 way ( 8 + 12 ), double door vertical type |
| 86 | Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 KA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB's DB complete with connections, testing and commissioning etc. as required.6/32 amps, single pole |
| 87 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 88 | Supplying and fixing following rating, four pole ( three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having sensitivity current 30 mili amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.16/25 amps |
| 89 | Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sqmm FR PVC insulated copper conductor single core in surface / recessed PVC conduit, with modular switch, modular plate suitable GI box etc as required. |
| 90 | Group AWiring for twin control points with 1.5 sq mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, 2 way with modular switch, modular plate, suitable GI box etc. as required. |
| 91 | Wiring for light/power plug with 2 X 4 sq mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, along with 1 nos 4 sq mm FR PVC insulated copper conductor single for loop earthing etc as required. |
| 92 | Wiring for Circuit / sub main wiring along with earth wire with following sizes of FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit as required.2 X 1.5 sq mm + 1 X 1.5 sq mm earth wire |
| 93 | Supplying and fixing stepped type electronic fan regulator on the existing modulat plate & switch box including connections but excluding modular plate etc. as required. |
| 94 | Supplying and fixing modular blanking plate & switch box excluding modular plate etc. as required. |
| 95 | Supplying and fixing following size / modules, GI boxes along with modular base & cover plate for modular switches in recess etc as required.1 or 2 Module |
| 96 | 4 / 5 Module |
| 97 | 6 Module |
| 98 | Supplying and fixing suitable GI box with modular plate and cover in front on surface of in recess, including providing & fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch connection, painting etc. as required (For light plugs to be used in non residential buildings) |
| 99 | Supplying and fixing suitable GI box with modular plate and cover in front on surface of in recess, including providing & fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch connection, painting etc. as required (For light plugs to be used in non residential buildings) |
| 100 | Supplying and fixing 2 pin 5 amp. Ceiling rose on the existing junction box / wooen block including connection etc. as required. |
| 101 | Supplying and fixing Batten / angle holder including connection etc. as required. |
| 102 | Supplying, Installation, testing & commisioning of following size ceiling fan 3 blades confirming to IS:374:2019 including the wiring down rods of standard length up to 30 cm with 1.5 sq mm FR PVC insulated copper wire suitable for 230V 50HZ, single phase supply etc. complete as required. |
| 103 | Installation of exhaust fan up to 450 mm sweep in the existing opening including making the hole to suit the size of the above fan making good the damage, connection, testing , commissioning etc. as required. |
| 104 | 12\\" (300mm) Exhaust fan |
| 105 | 6/7 w led square down light |
| 106 | Bricks =10 km(7+3) |
| 107 | Sand=20 km(18+2) |
| 108 | Stone chips =25 km |
| 109 | Cement =30 km |
| 110 | G.S.T 18% |
| 111 | L.C 1% Construction of granular sub-base by providing closed graded material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory powre roller to acheive the desire density complete as per clause 401 1:2:4 (1 cement : 2 coarse sand (zone- III) : 4 graded stone aggregate 20 mm nominal size) Filling in foundation trenches and pilinth layers not exceeding 150 mm thick well water, ramming, Fully compacted and fine dressed with earth obtained doctors after cutting with in a lead 50 mtr and lift of 1.5 mtr as per building specification and direction of E/I ................... Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 25, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysAug 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender