Tender For Repair / Maintenance Of Summer Appliances With Connected Items Under Ge (Af) Jamnagar No 1
Tender Overview
Project Description
Tender For Repair / Maintenance Of Summer Appliances With Connected Items Under Ge (Af) Jamnagar No 1- 1 M & L For Annual Servicing Of Split Air Conditioner Of Cap 1.5/2.0 Ton By Disconnecting Electric Connection From Its Stabilizer Or Its Electric Board And Remove The Front Cover Or Indoor Ac Unit And Cleaning It With Pressurized Water And Nylon Brush , Refixing The Front Cover Of Indoor Unit . Remove The Outer Cover Of Out Door Unit And Covered The Condensing Unit With Ploythene/Plastic Cover So That Water Shall Not Be Entered In The Motor While Cleaning The Unit And Clean The Filter With Pressureized Water Then Apply One Coat Of Descaling Solution And Clean With Wire Mesh Bursh/Nylon Brush To The Condensing Coil Of Out Door Unit And Greasing Of All Moving Parts. Cleaning Of Cooling And Condenser Coil Of Indoor And Outdoor Unit Shall Be Properly Carried Out Without Damaging Other Parts. Checking And Making Serviceable Electrical Connection Of Dbs, Stabilizer, Wiring Of Acs As Per Site Condition And Tightening All Electrical Connection Complete All As Specified And Directed By Engr-In-Charge. Note - Replacement Of Defective Parts With New Parts Shall Be Measured And Paid Seperately Under Respective Items In The Schedule. 2 Material And Labour For Leak Testing Of Cooling Coils Attached With Indoor And Outdoor Unit Of Split Air Conditioner Uisng Co2/Nitrogen Gas, Arrest Of Leakage With Brazing Of Copper Pipe And Retest Again For Leakage Complete All As Specified And As Directed By Engr-In- Charge 3 M & L For Charging Of Refrigerant R-410/ R-407 Gas To Air Conditioner Or As Per Existing /Manufacturer Instrcutions Suitable For Split Air Conditioner Cap 1.5 Ton After Flushing Out The Entire Refrigerant , Vaccum Testing Of Entire Closed Loop System For 24Hrs And Charging The Unit With Specified Quantity Of Gas , As Per Manufacturer Instructions,As Mentioned Above Complete All As Specified And As Directed By Engr-In-Charge 4 All As Per Item No.3 Above But For 2.0 Ton Capacity Complete As Per Manufacturer Instructions And As Directed By Engr-In-Charge. 5 M & L For Charging Of Refrigerant R-22/32 Gas To Air Conditioner Or As Per Existing /Manufacturer Instrcutions Suitable For Split Air Conditioner Cap 1.5 Ton After Flushing Out The Entire Refrigerant , Vaccum Testing Of Entire Closed Loop System For 24Hrs And Charging The Unit With Specified Quantity Of Gas , As Per Manufacturer Instructions,As Mentioned Above Complete All As Specified And As Directed By Engr-In-Charge 6 All As Per Item No.05 Above But For 2.0 Ton Capacity Complete As Per Manufacturer Instructions And As Directed By Engr-In-Charge. 7 Material And Labour For Maintenance Of Air Conditioner 1.5/2.0 Ton Capacity , Split Type Unit With Replacement Of Old/Unsv Spare Parts Mentioned As Under Or As Per Manufacturer Instructions Including Testing On Load Complete All As Specified And As Directed By Engr-In-Charge 8 S & F In Repair Over Load Protector Relay Suitable Range And Capacity As Per Existing 9 S & F In Repair Running Capacitor Of 36/45/50/60 + 5/6 Mfd Suitable For 240 Volts 50 Hz Ac Supply 10 S & F In Repair Capacitor Of 2.5 Mfd Suitable For Suitable For Blower Fan Motor Of 1.5/2.0 Ton Ac 11 S & F In Repair Capacitor Of 4 Mfd Suitable For Suitable For Blower Fan Motor Of 1.5/2.0 Ton Ac 12 S & F In Repairs Copper Tubing Of Size 1/2\ Or 3/8\ Suitable For Split Ac With Nitrile Self Adhesive Foam Wrapped With Pvc Insulation All Around The Pipe Line Complete 13 S & F In Repairs Copper Tubing Of Size 1/4\ Or 5/8\ Suitable For Split Ac With Nitrile Self Adhesive Foam Wrapped With Pvc Insulation All Around The Pipe Line Complete 14 Supply And Fix In Repair Flexible Pvc Pipe 20Mm Dia For Condense Water Outlet As Per Existing All As Directed & As Per Site Requirement. 15 S & F In Repairs Copper Condenser Coil Suitable For Split Ac Of Cap 1.5/2.0 Ton Complete With Necessary Electrical Connection 16 M&L In Repairs Evaporator Copper Cooling Coil Suitable For Indoor Unit Split Ac Of Cap 1.5/2.0 Ton Complete With Necessary Electrical Connection 17 S & F In Repairs Blower Motor Of 1/7 Hp To 1/6 Hp 230 Volts 930 Rpm, 20 Watt, 3 Speed For Indoor Unit Of Split Ac 1.5/2.0 Tr Of Existing Make Complete. Make :- Carrier/Voltas/Lg/Samsung Or As Per Existing Make Of Ac At Site. 18 S & F In Repairs Condenser Fan Motor 1/8 To 1/12 Hp, 900/1400 Rpm, 60 Watt Suitable For 1.5/2 Tr Split Ac Outdoor Unit, Single Phase, Of Existing Make Complete. Make:- Lg/Bluestar/Voltas Or As Per Existing Make Of Ac At Site. 19 S & F In Repairs Codenser Fan Motor For Outdoor Unit Suitable For Inverter Type Split Ac 1.5/2.0 Tr Of Existing Make Complete 20 S & F In Repairs Blower Motor For Indoor Unit Suitable For Inverter Type Split Ac 1.5/2.0 Tr Of Existing Make Complete 21 S & F In Repairs Blade Set Of Fan Motor Of Out Door Unit, Made Out Of Pvc Suitable For Shaft Bore Dia 1/2\ And Fan Dia 16\/ 18\ In Existing Air Conditioner Split Type 22 S & F In Repairs Pvc Fan Blower Assembly For 1.5 /2Tr Split AcS Any Make 23 S & F In Repairs/Replacement Of Non Invertor Printed Circuit Board (Pcb) With Suitable For Split Ac 1.5/2.0 Tr Of Any Capacity, Model And Make As Per Existing Complete With Necessary Electrical Connection. 24 S & F In Repairs/Replacement Of Printed Circuit Board(Pcb) Of Indoor & Outdoor Unit (Set Complete) Suitable For Inverter Type Split Ac 1.5/2.0 Tr Of Any Capacity, Model And Make As Per Existing Complete With Necessary Electrical Connection. 25 M&L In Repairs Swing Motor Of Suitable For Indoor Unit Of Split Ac Suitable For Any Make And Description Complete 26 Supply And Fixing Contactor 25 Amp Suitable For Split Ac 1.5/2Tr Complete All As Specified And As Directed 27 Supply And Fixing Controller Suitable For Flame Proof Ac Of Capacity 1.5 Ton Window Type Acs Complete All As Specified 28 Supply And Fixing In Repair Front Jali(Steel Wire Mesh) Suitable For Outdoor Unit Of Any Capacity And Make Complete All As Specified And As Directed By Engr-In-Charge 29 Supply And Fixing In Repair Rubber Insulation Suitable For Copper Piping Of Size 1/2 Complete All As Specified And As Directed By Engr In Charge 30 Supply And Fixing In Repair Rubber Insulation Suitable For Copper Piping Of Size 1/4 Complete All As Specified And As Directed By Engr In Charge 31 S&F Pvc Conduit Medium Grade 25Mm Dia Complete Including Fixing Arrangement ,Fixed On Waal/Room As Per Site Requirement All As Specified And As Directed By Engr -In-Charge 32 M & L For Repairs To Internal Remote Assembly Cordless Type Suitable For Split Air Conditioner Complete All A Specified And Directed By Engr-In Charge 33 S & F In Repair Air Conditioner Indoor Unit Single Phase As Per Existing Brand Complete With All Connection And Taking Out Old Unsv For The Following Cap Of Air Conditioner. Make : Samsung / Voltas/ Carrier/ Lg/ O General/ Hitachi 34 1.5 Ton Capacity 35 2.0 Ton Capacity 36 S & F In Repair Air Conditioner Outdoor Unit Single Phase As Per Existing Brand Complete With All Connection And Taking Out Old Unsv For The Following Cap Of Air Conditioner. Make : Samsung/Voltas /Carrier/ Lg/ O General /Hitachi 37 1.5 Ton Capacity 38 2.0 Ton Capacity 39 M & L For Replacement Of Defective Compressor Suitable For Air Conditioner With New Compressor Filled With Capila D And Charging Of Refrigerant Gas Up To Required Capacity After Flushing The Complete Refrigerant System Including Repair To Leakage If Any In Refrigerant Piping Complete For Split Type AcS Of The Following Capacity Complete All As Specified And Directed By Engr-In-Charge. (Make Of Compressor Godrej Or Any Other Equivalent 40 1.5 Ton Capacity 41 2.0 Ton Capacity 42 1.5 Ton Capacity But Flame Proof Window Ac 43 Taking Down / Dismantling Carefully The Indoor And Outdoor Unit Of Split Ac Of Capacity 1.5 Tr / 2.0 Tr With Outdoor Stand, Plate For Indoor Unit And Connected Wiring, Transportation Of Complete Set From Old Location To New Location (With Af Station Jamnagar), Refixing Of Same Ac At New Location Complete All As Directed By Engr-In-Charge & Detail As Under:- (A) Fixing Of Indoor Unit Wall Mounting Type (To Be Installed Inside The Room) Complete With, Draining Out Arrangement For Condensed Water, Fixing Of Inter Connection Pipe, All As Directed. Fixing Of Cooling Unit On Wall Shall Be As Per Standard Recommendation Practice Of Manufacturers.(B) Erection Of Condenser, Compressor Unit On Outside Of The Building, Fixed Over Old Clamp / Bracket, All As Per Standard Practice Of Manufacturer.(C) All Civil Work Such As Making Hole In The Wall For Passing Of Pipe Etc, To Be Done, As Directed By Engr-In-Charge Including Making Good Disturbed Surface.(D) Concealing Of Refrigerant Pipe With Pvc Flexible Pipe. (E) Extention Of Copper Pipe Due To Site Condition If Required Shall Be Measured And Paid Separately Under Respective Items Taken Before. 44 Supply And Fixing Split Ac Outdoor Unit Wall Stand Duly Painted With Fixing Fastners/Nut & Bolts Etc Complate All As Specified And As Directed By Engr-In-Charge 45 Supply And Fix Pvc Insulated And Fr Pvc Round Sheathed , Copper Conductor Flexible Industrial Cable , 1100 Volts Of Size 2.5Sqmm X 3 Core. 46 Supply And Fix Mcb’S Single Pole 6-32 Amps, 230 Volts With ‘C’ Curve, Fixed In Sheet Metal Board Complete Including Connecting. 47 Supply And Fix In Repair Metal Clad Single Pole And Earth Enclosure With Two Pin And Earth Plugs And Socket Complete With One Single Pole Mcb 20 Amps, 230 V, C Curve. 48 Supply And Fix In Repair Voltage Stabilizer For Automatic Operation , Single Phase Naturally Air Cooled Indoor Type And Designed For Input Variation Voltage As Under And Output Voltage Stabilized At 230Volts With Accuracy Of ± 2.5% For The Following Capacity Including Depositing Of Old Stabilizer At Mes Store Yard Complete All As Specified And Directed By Engr-In-Charge. 49 12 Amp Voltage Stablizer Suitable For 1.5 Ton Air Conditioner For Input Variation Between 150V To 290Vmake : V Guard/Volina/Microtek/Bluebird 50 15 Amp Voltage Stablizer Suitable For 2.0 Ton Air Conditioner For Input Variation Between 130V To 300V Make : V Guard/Volina/Microtek/Bluebird 51 Material And Labour For Servicing/Cleaning Of Water Cooler Of Storage Capacity/ Nominal Cooling Capacity(Ltrs/Hr) 40/80 & 60/120 Litres With The Use Of Antiscaling Agent For Internal Steel Water Tank ,Outer Body And Condenser Coil Of Water Cooler, Removal Of Dust And Other Deposited Material For The Various Functional Equipment Using Smooth Nylon Brush ,Cleaning Of Drainage For Speedy Water Removal And Checking Of Electrical Connection To Compressor And Other Electrically Operated Equipments, Cleaning Of Fins And Tubes Of Condenser,Repair/Replacement Of Puf Thermal Insulation, Checking Of Refrigerant Leakage And Functionality Of Water Tap Complete All As Specified And As Directed By Engr-In-Charge 52 M & L For Charging Of Refrigerant R-12/134A Gas To Water Cooler For The Following Capacities As Per Existing /Manufacturer Instrcutions After Flushing Out The Entire Refrigerant , Vaccum Testing Of Entire Closed Loop System For 24Hrs And Charging The Unit With Specified Quantity Of Gas , As Per Manufacturer Instructions,As Mentioned Above Complete All As Specified And As Directed By Engr-In-Charge 53 Storage Capacity 80 Ltrs And Cooling Capacity 40 Ltrs 54 Storage Capacity 120 Ltrs And Cooling Capacity 60 Ltrs 55 S&F In Repair Hermetic Type/Reciprocating Type Compressor Suitable For Water Cooler Type 40/80 Litres & 60/120 Ltrs As Per Site Requirement Make: Emerson Copland/ Carrier/ Blue Star/Tecumsah/Godrej 56 S & F In Repair Copper Coiled Condensor Suitable For Water Cooler Storage Type Of 40/80 Or 60/120 Litres 57 Material And Labour For Leak Test With Co2/Nitrogen Gas And Arresting Leakage With Brazing Of Copper Pipe Complete All As Specified. 58 Supply And Fixing Water Tap Of Suitable Size For Water Cooler Storage Type Of 40/80 Or 60/120 Ltrs 59 Dismantling Condenser Fan Motor Of Capacity 1/7 To 1/5 Hp Suitable For 40/80 And 60/120 Ltrs Water Cooler And Supply And Fixing In Repair Of New Fan And Motor A75 To 90 Watt, Make And Size And Refixing In Position , Connecting And Testing On Load Complete All As Specified And As Directed By Engr-In-Char 60 Material And Labour For Repair /Maintenance/ Servicing Of Refrigerator Of Any Capacity By Periodic Cleaning Of Internal And External Parts, Cleaning Of Water Collection Area And Checking Of Electrical Circuit Repair/ Replacement Of Unserviceable/Worn Out Spares And Accessories To Make The Refigerator In Good Working Condition Complete All As Specified And Directed By Engineer-In-Charge. Note: Defective Spares Required For Replacement Shall Be Measured And Paid Separately Under Respective Items. 61 Material And Labour For Maintenance Of Refrigerator Any Capacity With Replacement Of Old/Unsv Spare Parts As Under Including Testing On Load Complete All As Specified And As Directed By Engr-In-Charge 62 S & F In Repair Condensor Suitable For Refigerator Of Capacity 190 To 310 Ltr Cap 63 S & F In Repair Cooling Effect Transmitting Fan Motor Suitable For Refigerator Of 190 To 310 Ltr Cap 64 S & F In Repair Timer With Timer Relay Suitable For Refigerator Of 190 To 310 Ltr Cap 65 S & F In Repair Compressor Relay Suitable For Refigerator Of 190 To 310 Ltr Cap Cap Or As Per Exis 66 S & F In Repair Thermostat Suitable For Refigerator Of 190 To 310 Ltr Cap Make: Indofos/Godrej/Annapurna 67 S & F In Repair Capillary With Filter Suitable For Refigerator Of 190 To 310 Ltr Cap 68 S & F In Repair Compressor Suitable For Refigerator Of 190 To 310 Ltr Cap Or As Per Existing Make: Godrej/Teccumesh /Voltas/ Whirpool / Kirloskar Copland 69 Material And Labour For Leak Test With Co2/Nitrogen Gas And Arresting Leakage With Brazing Of Copper Pipe Complete All As Specified. 70 Supply And Fixing Invertor Compressor Pcb Card For Refregiration As Per Size Given Below :- 71 (A) Refregirator Of Capacity 165 Ltrs To 190 Ltrs 72 (B) Refregirator Of Capacity 250 Ltrs To 310 Ltrs 73 M & L For Charging Of Refrigerant R-134A Gas To Refrigerator For The Following Capacities As Per Existing /Manufacturer Instrcutions After Flushing Out The Entire Refrigerant , Vaccum Testing Of Entire Closed Loop System For 24Hrs And Charging The Unit With Specified Quantity Of Gas , As Per Manufacturer Instructions,As Mentioned Above Complete All As Specified And As Directed By Engr-In-Charge 74 Refrigerator Cap 165/195 Ltrs 75 Refrigerator Cap 230/250 Ltrs 76 Refrigerator Cap 300/310 Ltrs 77 Material And Labour For Carrying Out Repair /Maintenance/ Servicing Of Deep Freezer Of Any Cap Of Freezer With Periodic Cleaning Of Compressor Placement Area, Cleaning Of Water Tub And Checking Of Electrical Circuit Repair/ Replacement Of Unserviceable/Worn Out Spares And Accessories To Make The Deep Freezer In Good Working Condition Complete All As Specified And Directed By Engineer-In-Charge. Note: Defective Spares Required For Replacement Shall Be Measured And Paid Separately Under Respective Items. 78 Material And Labour For Servicing/Cleaning Of Water Dispenser Of Cooling Capacity 2.5 Ltr/Hr And Heating Capacity 5.0 Ltr/Hr Of Any Make, With The Use Of Antiscaling Agent For Internal Steel Water Tank ,Outer Body And Condenser Coil Of Water Cooler, Removal Of Dust And Other Deposited Material For The Various Functional Equipment Using Smooth Nylon Brush ,Cleaning Of Drainage For Speedy Water Removal And Checking Of Electrical Connection To Compressor And Other Electrically Operated Equipments, Cleaning Of Fins And Tubes Of Condenser, Repair / Replacement Of Puf Thermal Insulation, Checking Of Refrigerant Leakage And Functionality Of Water Tap Complete All As Specified And As Directed By Engr-In-Charge 79 M & L For Charging Of Refrigerant R-12/134A Gas To Water Dispenser Of Cooling Capacity 2.5 Ltr/Hr And Heating Capacity 5.0 Ltr/Hr Of Any Make As Per Existing /Manufacturer Instrcutions After Flushing Out The Entire Refrigerant , Vaccum Testing Of Entire Closed Loop System For 24Hrs And Charging The Unit With Specified Quantity Of Gas , As Per Manufacturer Instructions,As Mentioned Above Complete All As Specified And As Directed By Engr-In-Charge 80 Material And Labour For Maintenance Of Water Dispenser With Replacement Of Old/Unsv Spare Parts As Under Including Testing On Load Complete All As Specified And As Directed By Engr-In-Charge 81 Supply And Fix In Repair Compressor, Single Phase, 230 V Suitable For Water Dispenser Of Cooling Capacity 2.5 Ltr/Hr And Heating Capacity 5.0 Ltr/Hr Of Any Make. 82 S&F In Repairs Copper Condenser Coil Suitable For Water Dispenser Of Cooling Capacity 2.5 Ltr/Hr And Heating Capacity 5.0 Ltr/Hr Along With Necessary Electrical Connections Etc. All As Specified And Directed By Engineer-In-Charge. 83 S & F In Repairs Compressor Relay Suitable For Water Dispenser Of Cooling Capacity 2.5 Ltr/Hr And Heating Capacity 5.0 Ltr/Hr.Make :- As Per Recommendation Of Oem And Approved By The Ge. 84 S & F In Repairs Running Capacitor Suitable For Water Dispenser Of Cooling Capacity 2.5 Ltr/Hr And Heating Capacity 5.0 Ltr/Hr.Make :- As Per Recommendation Of Oem And Approved By The Ge. 85 S & F In Repairs Thermostat Suitable For Water Dispenser Of Cooling Capacity 2.5 Ltr/Hr And Heating Capacity 5.0 Ltr/Hr.Make :- As Per Recommendation Of Oem And Approved By The Ge. 86 S & F In Repairs Heating Element With Tank For Water Dispenser Of Cooling Capacity 2.5 Ltr/Hr And Heating Capacity 5.0 Ltr/Hr.Make :- As Per Recommendation Of Oem And Approved By The Ge. 87 Material And Labour For Leak Test With Co2/Nitrogen Gas And Arresting Leakage With Brazing Of Copper Pipe Of Water Dispenser Complete All As Specified. 88 Supply And Fix Mcb’S In Repair Triple Pole, 63 Amps, 415 Volts With ‘C’ Curve, Fixed In Sheet Metal Board Complete Including Connect 89 Supply And Fix Mcb’S In Repair Triple Pole, 16 Amps, 415 Volts With ‘C’ Curve, Fixed In Sheet Metal Board Complete Including Connecting 90 Comprehensive / Preventive Maintenance Of Industrial Type Air Conditioning Of Capacity 2.0 Tr (Make: Emerson) With Connected Indoor And Outdoor Units, Maintenece Shall Be Carried Out As Per Manufacturer Standard Check List And Detailed As Under All As Directed By Engineer-In-Charge.(A) Cleaning The Evaporator Coil Of Indoor Unit With Pressureized Water Then Apply One Coat Of Descaling Solution And Clean With Nylon Brush And Then Testing/ Checking Of Evaporator Coil For Leakage And Rectification Of Leakage By Brazing Including.(B) Cleaning Of Condensing Coil Of Outdoor Unit With Pressurised Water And Then Testing/ Checking Of Cooling Coil For Leakage And Rectification Of Leakage By Brazing Including.(C) Testing / Checking And Cleaning Of Air Filter.(D) Testing / Checking Of Compressor For Its Proper Functioning And Rectification Of Minor Defect If Any.(E) Testing / Checking & Servicing Of Blower Fan Motor And Rectification Of Minor Defect If Any.(F) Testing / Checking & Servicing Of Condenser Fan Motor And Rectification Of Minor Defect If Any.(G) Testing / Checking Of Control Switch Such As Pressure Cut Outs, Refrigerent Flow Switch, Temprature Sensore For Proper Functiong.(H) Testing / Checking Of Refrigerant Pipe For Leakage And Rectification Of Leakage By Brazing Including Cleaning Of Refrigerant Pipe.(J) Testing / Checking Of All Electrical Connection And Control Wiring Tighting Of Electrical Connection And Rectification Of Minor Defect If Any Complete. Note : Servicing Of Industrial Ac Should Be Done In Two Time During The Contractor Period As Per Direction Of Engr-In-Charge (Min 4 Month Gap Between Two Services) 91 Material & Labour For Charging Of Refrigerant R-407 Gas To 2.0 Tr Capacity Industrial Type Intelle Split Ac After Flushing The Complete System, Vacuum Testing Up To 24 Hours And The Repairing The Leaking Tube / Lines By Brazing, Including Charging The Unit With Appropriate Qty Of Gas As Per ManufactureS Instruction Complete All As Directed By Engineer-In-Charge. 92 M&L For Dismantling Blower Fan Motor (Hp-0.33 , V-415, Rpm-920) Of Industrial Type Intelle Split Ac 2 Tr (Outdoor) And Supply And Fixing New Fan Motor Along With Fan Of Existing Make And Size And Refixing In Position, Connecting And Testing On Load All As Specified And Directed By Engineer-In-Charge. Make :- Spartan Electrical Pvt Ltd Or Any Other Make As Per Recommendation Of Oem And Approved By The Ge. 93 M&L For Dismantling Condenser Fan Motor(Kw-0.18,Rpm-920,Frame-S90, Ip-44) Of Industrial Type Intelle Split Ac 2.0 Tr Capacity (Indoor) And Supply And Fixing New Fan Motor Along With Fan Of Existing Make And Size And Refixing In Position, Connecting And Testing On Load All As Specified And Directed By Engineer-In-Charge.Make :- Spartan Electrical Pvt Ltd Or Any Other Make As Per Recommendation Of Oem And Approved By The Ge. 94 Supply And Fix In Repair Lp Switch 60 No 35 Psi , 6A 250V Suitable For Compressor Of Industrial Type Intelle Split Ac 2.0Tr Make - As Per Recommendation Of Oem And Approved By The Ge. 95 Supply And Fix In Repair Hp Switch 400 Nc 320 Psi Suitable For Compressor Of Industrial Type Intelle Split Ac 2.0Tr Capacity.Make - As Per Recommendation Of Oem And Approved By The Ge.
BOQ
| Sl. No. | Item Description |
| 1 | M & L for annual servicing of Split Air conditioner of cap 1.5/2.0 ton by disconnecting electric connection from its stabilizer or its electric board and remove the front cover or indoor AC unit and cleaning it with pressurized water and nylon brush , refixing the front cover of indoor unit . Remove the outer cover of out door unit and covered the condensing unit with ploythene/plastic cover so that water shall not be entered in the motor while cleaning the unit and clean the filter with pressureized water then apply one coat of descaling solution and clean with wire mesh bursh/nylon brush to the condensing coil of out door unit and greasing of all moving parts. Cleaning of Cooling and condenser coil of indoor and outdoor unit shall be properly carried out without damaging other parts. Checking and making serviceable electrical connection of DBs, Stabilizer, wiring of ACs as per site condition and tightening all electrical connection Complete all as specified and directed by Engr-in-Charge. Note - Replacement of defective parts with new parts shall be measured and paid seperately under respective items in the schedule. |
| 2 | Material and labour for Leak testing of cooling coils attached with indoor and outdoor unit of split air conditioner uisng CO2/Nitrogen gas, arrest of leakage with brazing of copper pipe and retest again for leakage complete all as specified and as directed by Engr-in- Charge |
| 3 | M & L for charging of refrigerant R-410/ R-407 gas to air conditioner or as per existing /manufacturer instrcutions suitable for split air conditioner cap 1.5 ton after flushing out the entire refrigerant , vaccum testing of entire closed loop system for 24hrs and charging the unit with specified quantity of gas , as per manufacturer instructions,as mentioned above complete all as specified and as directed by Engr-in-charge |
| 4 | All as per item no.3 above but for 2.0 ton capacity complete as per manufacturer instructions and as directed by Engr-in-Charge. |
| 5 | M & L for charging of refrigerant R-22/32 gas to air conditioner or as per existing /manufacturer instrcutions suitable for split air conditioner cap 1.5 ton after flushing out the entire refrigerant , vaccum testing of entire closed loop system for 24hrs and charging the unit with specified quantity of gas , as per manufacturer instructions,as mentioned above complete all as specified and as directed by Engr-in-charge |
| 6 | All as per item no.05 above but for 2.0 ton capacity complete as per manufacturer instructions and as directed by Engr-in-Charge. |
| 7 | Material and labour for maintenance of air conditioner 1.5/2.0 ton capacity , Split type unit with replacement of old/unsv spare parts mentioned as under or as per manufacturer instructions including testing on load complete all as specified and as directed by Engr-in-charge |
| 8 | S & F in repair over load protector relay suitable range and capacity as per existing |
| 9 | S & F in repair Running capacitor of 36/45/50/60 + 5/6 mfd suitable for 240 volts 50 HZ AC Supply |
| 10 | S & F in repair capacitor of 2.5 mfd suitable for suitable for blower fan motor of 1.5/2.0 ton AC |
| 11 | S & F in repair capacitor of 4 mfd suitable for suitable for blower fan motor of 1.5/2.0 ton AC |
| 12 | S & F in repairs copper tubing of size 1/2\\" or 3/8\\" suitable for split AC with nitrile self adhesive foam wrapped with PVC insulation all around the pipe line complete |
| 13 | S & F in repairs copper tubing of size 1/4\\" or 5/8\\" suitable for split AC with nitrile self adhesive foam wrapped with PVC insulation all around the pipe line complete |
| 14 | Supply and fix in repair flexible PVC pipe 20mm dia for condense water outlet as per existing all as directed & as per site requirement. |
| 15 | S & F in repairs copper condenser coil suitable for split AC of cap 1.5/2.0 ton complete with necessary electrical connection |
| 16 | M&L in repairs evaporator copper cooling coil suitable for indoor unit split AC of cap 1.5/2.0 ton complete with necessary electrical connection |
| 17 | S & F in repairs Blower motor of 1/7 HP to 1/6 HP 230 volts 930 RPM, 20 Watt, 3 speed for indoor unit of split AC 1.5/2.0 TR of existing make complete. Make :- Carrier/Voltas/LG/Samsung or as per existing make of AC at site. |
| 18 | S & F in repairs condenser fan motor 1/8 to 1/12 HP, 900/1400 RPM, 60 Watt suitable for 1.5/2 TR split AC outdoor unit, single phase, of existing make complete. Make:- LG/Bluestar/Voltas or as per existing make of AC at site. |
| 19 | S & F in repairs Codenser Fan motor for outdoor unit suitable for inverter type split AC 1.5/2.0 TR of existing make complete |
| 20 | S & F in repairs Blower motor for indoor unit suitable for inverter type split AC 1.5/2.0 TR of existing make complete |
| 21 | S & F in repairs Blade set of fan motor of out door unit, made out of PVC Suitable for shaft bore dia 1/2\\" and fan dia 16\\"/ 18\\" in existing air conditioner split type |
| 22 | S & F in repairs PVC fan blower assembly for 1.5 /2TR split AC's any make |
| 23 | S & F in repairs/replacement of Non invertor Printed circuit board (PCB) with suitable for Split AC 1.5/2.0 TR of any capacity, model and make as per existing complete with necessary electrical connection. |
| 24 | S & F in repairs/replacement of Printed circuit board(PCB) of Indoor & Outdoor unit (Set Complete) suitable for Inverter type Split AC 1.5/2.0 TR of any capacity, model and make as per existing complete with necessary electrical connection. |
| 25 | M&L in repairs Swing motor of suitable for indoor unit of split AC suitable for any make and description complete |
| 26 | Supply and fixing contactor 25 Amp suitable for split AC 1.5/2TR complete all as specified and as directed |
| 27 | Supply and fixing controller suitable for flame proof AC of capacity 1.5 Ton window type Acs complete all as specified |
| 28 | Supply and fixing in repair front Jali(steel wire mesh) suitable for outdoor unit of any capacity and make complete all as specified and as directed by Engr-in-charge |
| 29 | Supply and fixing in repair rubber insulation suitable for copper piping of size 1/2 complete all as specified and as directed by Engr in charge |
| 30 | Supply and fixing in repair rubber insulation suitable for copper piping of size 1/4 complete all as specified and as directed by Engr in charge |
| 31 | S&F PVC conduit medium grade 25mm dia complete including fixing arrangement ,fixed on waal/room as per site requirement all as specified and as directed by Engr -in-charge |
| 32 | M & L for repairs to internal remote assembly cordless type suitable for split air conditioner complete all a specified and directed by Engr-in Charge |
| 33 | S & F in repair air conditioner indoor unit single phase as per existing brand complete with all connection and taking out old unsv for the following cap of air conditioner. Make : Samsung / Voltas/ Carrier/ LG/ O General/ Hitachi |
| 34 | 1.5 ton capacity |
| 35 | 2.0 ton capacity |
| 36 | S & F in repair air conditioner outdoor unit single phase as per existing brand complete with all connection and taking out old unsv for the following cap of air conditioner. Make : Samsung/Voltas /Carrier/ LG/ O General /Hitachi |
| 37 | 1.5 ton capacity |
| 38 | 2.0 ton capacity |
| 39 | M & L for replacement of defective compressor suitable for air conditioner with new compressor filled with capila D and charging of refrigerant gas up to required capacity after flushing the complete refrigerant system including repair to leakage if any in refrigerant piping complete for split type AC's of the following capacity complete all as specified and directed by Engr-in-charge. (Make of compressor Godrej or any other equivalent |
| 40 | 1.5 ton capacity |
| 41 | 2.0 ton capacity |
| 42 | 1.5 Ton Capacity but Flame proof window AC |
| 43 | Taking down / Dismantling carefully the indoor and outdoor unit of Split AC of capacity 1.5 TR / 2.0 TR with outdoor stand, plate for indoor unit and connected wiring, Transportation of complete set from old location to new location (with AF station Jamnagar), refixing of same AC at new location complete all as directed by Engr-in-Charge & detail as under:- (a) Fixing of indoor unit wall mounting type (to be installed inside the room) complete with, draining out arrangement for condensed water, fixing of inter connection pipe, all as directed. Fixing of cooling unit on wall shall be as per standard recommendation practice of manufacturers.(b) Erection of condenser, compressor unit on outside of the building, fixed over old clamp / bracket, all as per standard practice of manufacturer.(c) All civil work such as making hole in the wall for passing of pipe etc, to be done, as directed by Engr-in-Charge including making good disturbed surface.(d) concealing of refrigerant pipe with PVC flexible pipe. (e) Extention of copper pipe due to site condition if required shall be measured and paid separately under respective items taken before. |
| 44 | Supply and fixing Split AC outdoor unit wall stand duly painted with fixing fastners/nut & bolts etc complate all as specified and as directed by Engr-in-charge |
| 45 | Supply and fix PVC insulated and FR PVC round sheathed , copper conductor flexible industrial cable , 1100 Volts of size 2.5sqmm x 3 core. |
| 46 | Supply and fix MCB’s single pole 6-32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting. |
| 47 | Supply and fix in repair metal clad single pole and earth enclosure with two pin and earth plugs and socket complete with one single pole MCB 20 Amps, 230 V, C curve. |
| 48 | Supply and Fix in repair voltage stabilizer for automatic operation , single phase naturally air cooled indoor type and designed for input variation voltage as under and output voltage stabilized at 230Volts with accuracy of ± 2.5% for the following capacity including depositing of old stabilizer at MES store yard complete all as specified and directed by Engr-in-Charge. |
| 49 | 12 Amp voltage stablizer suitable for 1.5 ton air conditioner for input variation between 150V to 290VMake : V Guard/Volina/Microtek/Bluebird |
| 50 | 15 Amp voltage stablizer suitable for 2.0 ton air conditioner for input variation between 130V to 300V Make : V Guard/Volina/Microtek/Bluebird |
| 51 | Material and labour for servicing/cleaning of water cooler of storage capacity/ nominal cooling capacity(Ltrs/hr) 40/80 & 60/120 litres with the use of antiscaling agent for internal steel water tank ,outer body and condenser coil of water cooler, Removal of dust and other deposited material for the various functional equipment using smooth nylon brush ,cleaning of drainage for speedy water removal and checking of electrical connection to compressor and other electrically operated equipments, cleaning of fins and tubes of condenser,repair/replacement of PUF thermal insulation, checking of refrigerant leakage and functionality of water tap complete all as specified and as directed by Engr-in-charge |
| 52 | M & L for charging of refrigerant R-12/134a gas to water cooler for the following capacities as per existing /manufacturer instrcutions after flushing out the entire refrigerant , vaccum testing of entire closed loop system for 24hrs and charging the unit with specified quantity of gas , as per manufacturer instructions,as mentioned above complete all as specified and as directed by Engr-in-charge |
| 53 | storage capacity 80 ltrs and cooling capacity 40 ltrs |
| 54 | storage capacity 120 ltrs and cooling capacity 60 ltrs |
| 55 | S&F in repair Hermetic type/Reciprocating type compressor suitable for water cooler type 40/80 litres & 60/120 Ltrs as per site requirement Make: Emerson copland/ carrier/ Blue star/Tecumsah/Godrej |
| 56 | S & F in repair copper coiled condensor suitable for water cooler storage type of 40/80 or 60/120 Litres |
| 57 | Material and labour for Leak test with CO2/Nitrogen gas and arresting leakage with brazing of copper pipe complete all as specified. |
| 58 | Supply and fixing water tap of suitable size for water cooler storage type of 40/80 or 60/120 ltrs |
| 59 | Dismantling condenser fan motor of capacity 1/7 to 1/5 HP suitable for 40/80 and 60/120 Ltrs water cooler and Supply and fixing in repair of new fan and motor a75 to 90 watt, make and size and refixing in position , connecting and testing on load complete all as specified and as directed by Engr-in-char |
| 60 | Material and labour for repair /maintenance/ servicing of Refrigerator of any capacity by periodic cleaning of internal and external parts, cleaning of water collection area and checking of electrical circuit repair/ replacement of unserviceable/worn out spares and accessories to make the Refigerator in good working condition complete all as specified and directed by Engineer-in-Charge. Note: Defective spares required for replacement shall be measured and paid separately under respective items. |
| 61 | Material and labour for maintenance of Refrigerator any capacity with replacement of old/unsv spare parts as under including testing on load complete all as specified and as directed by Engr-in-charge |
| 62 | S & F in repair condensor suitable for Refigerator of capacity 190 to 310 ltr cap |
| 63 | S & F in repair cooling effect transmitting fan motor suitable for Refigerator of 190 to 310 ltr cap |
| 64 | S & F in repair timer with timer relay suitable for Refigerator of 190 to 310 ltr cap |
| 65 | S & F in repair Compressor Relay suitable for Refigerator of 190 to 310 ltr cap cap or as per exis |
| 66 | S & F in repair thermostat suitable for Refigerator of 190 to 310 ltr cap Make: Indofos/Godrej/Annapurna |
| 67 | S & F in repair capillary with filter suitable for Refigerator of 190 to 310 ltr cap |
| 68 | S & F in repair Compressor suitable for Refigerator of 190 to 310 ltr cap or as per existing Make: Godrej/Teccumesh /Voltas/ Whirpool / Kirloskar copland |
| 69 | Material and labour for Leak test with CO2/Nitrogen gas and arresting leakage with brazing of copper pipe complete all as specified. |
| 70 | Supply and fixing invertor compressor PCB card for refregiration as per size given below :- |
| 71 | (a) Refregirator of capacity 165 ltrs to 190 Ltrs |
| 72 | (b) Refregirator of capacity 250 Ltrs to 310 ltrs |
| 73 | M & L for charging of refrigerant R-134a gas to Refrigerator for the following capacities as per existing /manufacturer instrcutions after flushing out the entire refrigerant , vaccum testing of entire closed loop system for 24hrs and charging the unit with specified quantity of gas , as per manufacturer instructions,as mentioned above complete all as specified and as directed by Engr-in-charge |
| 74 | Refrigerator cap 165/195 Ltrs |
| 75 | Refrigerator cap 230/250 Ltrs |
| 76 | Refrigerator cap 300/310 Ltrs |
| 77 | Material and labour for carrying out repair /maintenance/ servicing of Deep freezer of any cap of freezer with periodic cleaning of compressor placement area, cleaning of water tub and checking of electrical circuit repair/ replacement of unserviceable/worn out spares and accessories to make the Deep Freezer in good working condition complete all as specified and directed by Engineer-in-Charge. Note: Defective spares required for replacement shall be measured and paid separately under respective items. |
| 78 | Material and labour for servicing/cleaning of water dispenser of cooling capacity 2.5 ltr/hr and heating capacity 5.0 ltr/hr of any make, with the use of antiscaling agent for internal steel water tank ,outer body and condenser coil of water cooler, Removal of dust and other deposited material for the various functional equipment using smooth nylon brush ,cleaning of drainage for speedy water removal and checking of electrical connection to compressor and other electrically operated equipments, cleaning of fins and tubes of condenser, repair / replacement of PUF thermal insulation, checking of refrigerant leakage and functionality of water tap complete all as specified and as directed by Engr-in-charge |
| 79 | M & L for charging of refrigerant R-12/134a gas to water dispenser of cooling capacity 2.5 ltr/hr and heating capacity 5.0 ltr/hr of any make as per existing /manufacturer instrcutions after flushing out the entire refrigerant , vaccum testing of entire closed loop system for 24hrs and charging the unit with specified quantity of gas , as per manufacturer instructions,as mentioned above complete all as specified and as directed by Engr-in-charge |
| 80 | Material and labour for maintenance of water dispenser with replacement of old/unsv spare parts as under including testing on load complete all as specified and as directed by Engr-in-charge |
| 81 | Supply and fix in repair compressor, single phase, 230 V suitable for water dispenser of cooling capacity 2.5 ltr/hr and heating capacity 5.0 ltr/hr of any make. |
| 82 | S&F in repairs Copper Condenser coil suitable for water dispenser of cooling capacity 2.5 ltr/hr and heating capacity 5.0 ltr/hr along with necessary electrical connections etc. all as specified and directed by Engineer-in-charge. |
| 83 | S & F in repairs Compressor relay suitable for water dispenser of cooling capacity 2.5 ltr/hr and heating capacity 5.0 ltr/hr.Make :- as per recommendation of OEM and approved by the GE. |
| 84 | S & F in repairs running capacitor suitable for water dispenser of cooling capacity 2.5 ltr/hr and heating capacity 5.0 ltr/hr.Make :- as per recommendation of OEM and approved by the GE. |
| 85 | S & F in repairs thermostat suitable for water dispenser of cooling capacity 2.5 ltr/hr and heating capacity 5.0 ltr/hr.Make :- as per recommendation of OEM and approved by the GE. |
| 86 | S & F in repairs heating element with tank for water dispenser of cooling capacity 2.5 ltr/hr and heating capacity 5.0 ltr/hr.Make :- as per recommendation of OEM and approved by the GE. |
| 87 | Material and labour for Leak test with CO2/Nitrogen gas and arresting leakage with brazing of copper pipe of water dispenser complete all as specified. |
| 88 | Supply and fix MCB’s in repair triple pole, 63 Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including connect |
| 89 | Supply and fix MCB’s in repair triple pole, 16 Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including connecting |
| 90 | Comprehensive / Preventive maintenance of Industrial type Air conditioning of capacity 2.0 TR (Make: Emerson) with connected indoor and outdoor units, maintenece shall be carried out as per manufacturer standard check list and detailed as under all as directed by Engineer-in-Charge.(a) Cleaning the evaporator coil of indoor unit with pressureized water then apply one coat of descaling solution and clean with nylon brush and then testing/ checking of evaporator coil for leakage and rectification of leakage by brazing including.(b) Cleaning of condensing coil of outdoor unit with pressurised water and then testing/ checking of Cooling coil for leakage and rectification of leakage by brazing including.(c) Testing / Checking and Cleaning of Air filter.(d) Testing / Checking of compressor for its proper functioning and rectification of minor defect if any.(e) Testing / Checking & servicing of blower fan motor and rectification of minor defect if any.(f) Testing / Checking & servicing of condenser fan motor and rectification of minor defect if any.(g) Testing / Checking of control switch such as pressure cut outs, refrigerent flow switch, temprature sensore for proper functiong.(h) Testing / Checking of refrigerant pipe for leakage and Rectification of leakage by brazing including cleaning of refrigerant pipe.(j) Testing / Checking of all electrical connection and control wiring tighting of electrical connection and rectification of minor defect if any complete. Note : Servicing of Industrial AC should be done in two time during the contractor period as per direction of Engr-in-charge (Min 4 month gap between two services) |
| 91 | Material & labour for charging of refrigerant R-407 gas to 2.0 TR capacity industrial type intelle split AC after flushing the complete system, vacuum testing up to 24 hours and the repairing the leaking tube / lines by brazing, including charging the unit with appropriate qty of gas as per manufacture's instruction complete all as directed by Engineer-In-Charge. |
| 92 | M&L for Dismantling blower fan motor (HP-0.33 , V-415, RPM-920) of industrial type intelle split AC 2 TR (Outdoor) and supply and fixing new fan motor along with fan of existing make and size and refixing in position, connecting and testing on load all as specified and directed by Engineer-in-charge. Make :- SPARTAN ELECTRICAL PVT LTD or any other make as per recommendation of OEM and approved by the GE. |
| 93 | M&L for Dismantling Condenser fan motor(KW-0.18,RPM-920,FRAME-S90, IP-44) of industrial type intelle Split AC 2.0 TR capacity (Indoor) and supply and fixing new fan motor along with fan of existing make and size and refixing in position, connecting and testing on load all as specified and directed by Engineer-in-charge.Make :- SPARTAN ELECTRICAL PVT LTD or any other make as per recommendation of OEM and approved by the GE. |
| 94 | Supply and fix in repair LP switch 60 NO 35 PSI , 6A 250V suitable for compressor of industrial type intelle split AC 2.0TR Make - as per recommendation of OEM and approved by the GE. |
| 95 | Supply and fix in repair HP switch 400 NC 320 PSI suitable for compressor of industrial type intelle split AC 2.0TR capacity.Make - as per recommendation of OEM and approved by the GE. |
| 96 | Supply and fix in repair expansion valve suitable for industrial type intelle split AC 2.0 TR capacity.Model- TUBE 06802073 03989 , Make- Danfoss |
| 97 | Supply and fix in repair three pole contactor Model No. LC1D32M7 suitable for industrial type intelle split AC of 2.0 TR capacity. |
| 98 | Supply and fix in repair over load protection relay Model No. LRE 05 suitable for industrial type intelle split AC of 2.0 TR capacity. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender