Bids Are invited for Supply Laying And Testing Cable Xlpe Insulated Screened Pvc Bedded Galvanized Steel Strip Or Wire Etc. - Supply, Laying & Testing Cable Xlpe Insulated, Screened, Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power
Tender Overview
Project Description
Bids Are invited for Supply Laying And Testing Cable Xlpe Insulated Screened Pvc Bedded Galvanized Steel Strip Or Wire Etc. - Supply, Laying & Testing Cable Xlpe Insulated, Screened, Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables (Heavy Duty) With Stranded Aluminium Conductor, 11000 Volts Grade, Of Size 95 Sq Mm 3 Core All As Specified And As Directed. , Excavation In Trenches Not Exceeding 1.5 M Width And Not Exc 1.5M In Depth Etc. - Excavation In Trenches Not Exceeding 1.5 M Width And Not Exc 1.5M In Depth Getting Out In Soft/Loose Soil All As Specified And As Directed. , Excavation In Trenches Not Exceeding 1.5 M Width And Exc 1.5M In Depth Etc. - Excavation In Trenches Not Exceeding 1.5 M Width And Exc 1.5M In Depth Getting Out In Soft/Loose Soil All As Specified And As Directed. , Returning Filling In Including Spreading Levelling Watering And Well Ramming In Layers Etc. - Returning Filling In Including Spreading Levelling Watering And Well Ramming In Layers Not Exceeding 25 Cm In Thick Using Excavated Soft/Loose Soil All As Specified And As Directed. , Removal Of Surplus Soil To A Distance Not Exceeding 50 M And Depositing Etc. - Removal Of Surplus Soil To A Distance Not Exceeding 50 M And Depositing Where Directed By Engr In Charge. , Supply And Lay Of Pcc Cable Cover Class Hv Type 1 Flat Size 300Mmx180mmx40mm Etc. - Supply And Lay Of Pcc Cable Cover Class Hv Type 1 Flat Size 300Mmx180mmx40mm Complete All As Specified And Directed. , Supply And Lay For Dry Clean Dirtless River Sand Filling For Cable Protection With A Layer Of 8Cm Etc. - Supply And Lay For Dry, Clean, Dirtless River Sand Filling For Cable Protection With A Layer Of 8Cm Deep Before Laying And 15Cm Covering Above The Top Edge Of Cable After Laying & Punned Down To Required Height, Complete All As Specified And As Directed.Note Only Punned Thickness Shall Be Measured & Paid. , M And L For Double Wall Corrugated Dwc High Density Polyethylene Pipes Hdpe Etc. - M&L For Double Wall Corrugated (Dwc) High Density Polyethylene Pipes (Hdpe) Of 90Mm Dia Laid In Trenches For Cable Protection Complete All As Spcified And Directed. , M And L For Fixing Gi Tubing 80Mm Dia Light Grade Use For The Protection Of Cable Etc. - M&L For Fixing Gi Tubing 80Mm Dia Light Grade Use For The Protection Of Cable All As Specified And Directed By Engr In Charge. , M And L For Manual Boring Under Road Crossing And Laying Pipe Across The Road Etc. - M&L For Manual Boring Under Road Crossing And Laying Pipe Across The Road For Laying Cables Complete All As Specified And As Directed. , S And F Pcc Cable Route Marker Of Size 900X300x70mm Embossed With Ht Ug Cable Etc. - S&F Pcc Cable Route Marker Of Size 900X300x70mm, Embossed With Ht Ug Cable 11Kv And Excavation Of 40Cm Depth, Grouted In And Including Pcc (1 2 4) Type B 2 (Using 20Mm Graded Stone Aggregate) Complete All As Specified And Directed. , Material And Labour For Steel Tubular Poles Complete With Cast Iron Base Palate Final Taper Plug Bolts Nuts And Screws Etc. - Material And Labour For Steel Tubular Poles Complete With Cast Iron Base Palate, Final Taper Plug Bolts, Nuts & Screws As Specified Type 410 Sp 55, 11.00 Meter Long Including Painting All External Exposed Steel Surfaces With Two Coats Of Aliminium Paint Over A Coat Of Red Oxide Zinc Chrome Primer Including Marking Pole Numbers In A 15 Cm Dia Yellow Circle With Number Writting With Black Syenthic Paint/ Stricker, Including Painting Strips In Alternate From Top Of Coping Upto 1.50M Height, With Three Strips Of Black Syenthatic Paint & Two Strips Of Yellow/ Sky Blue Paint (As Per Existing Pattern Through Out The Circumference Of Pole), Including All Internal Surfaces And External Surfaces Upto The Planting Depth Shall Be Painted With Two Coats Of Black Bitumenous Paint Complete All As Specified And As Directed Complete All As Specified. (Note Earth Work, Pcc Work, Shall Be Measured And Paid Separately.) , M And L For Switch Air Break Gang Operated Triple Pole Out Door Type Unit Etc. - M & L For Switch Air Break Gang Operated Triple Pole Out Door Type Unit On Ht 11 Kv 50 Cycle Ac Suitable For Current Rating Upto 400 S Mechanically Operated Mounted On Insulators (9 Insulators) And Frame With Operating Mechanism Worked From Ground Level With Earth Switch And Including Locking Arrangement, Acsr Conductor Complete With Taking Down Old Unserviceable Complete All As Specified And Directed. , M And L For 11 Kv 200 S Outdoor Type Horn Gap Fuse Set Conforming To Is 9385 Etc. - M & L For 11 Kv, 200 S, Outdoor Type Horn Gap Fuse Set Conforming To Is 9385 (Part I & Ii) / Relevant Latest Is Standards, Complete With Galvanized Steel Horn Assembly, Suitable Fuse Element, Heavy Duty Porcelain/Polymer Insulators, Gi Channel/Angle Mounting Structure, Connectors, Cl S, Nuts, Bolts And All Accessories, Installed On Pole Mounted Ht Structure Complete Including Taking Down Old Unserviceable All As Specified And Directed. , M And L For Cross Arms Bracing Supports Cl S And Back Plates Fabricated Etc. - M & L For Cross Arms , Bracing, Supports , Cl S And Back Plates Fabricated From Structural Steel Sections Including Nuts, Bolts, Washers, Welding Bending Cold Or Hot Drilling Holes For Bolts In Any Shape Or Size As Directed Inclusive Of 2 Coats Of Aluminium Paint Over A Coat Of Red Oxide Primer After Dismantling Old Unserviceable Cross Arms And Complete All As Specified And As Directed. , M And L For Pin Type Porcelain Vitreous Brown Insulator Of Size 150Mm Etc. - M & L For Pin Type, Porcelain, Vitreous Brown Insulator Of Size 150Mm Height, 150Mm Dia 11000 Volts Grade Including One Galvanized Mild Steel Spindle With Two Galvanized Iron Washers And One Galvanized Iron Nut Complete All As Specified And As Directed. , M And L For Lightning Arrester Surge Protector 11 Kv Grade Heavy Duty Single Pole Etc. - M & L For Lightning Arrester/Surge Protector 11 Kv Grade Heavy Duty, Single Pole, Self Supporting Station, Expulsion Type Class 65 Ka Capacity With All Fittings Complete All With Taking Down Old Unserviceable All As Specified And Directed. , S And F Danger Notice Plate Of 1.6Mm Thick Mild Steel Sheet Vitreous Enamelled Etc. - S & F Danger Notice Plate Of 1.6Mm Thick Mild Steel Sheet, Vitreous Enamelled White, With Letters, Figures And Conventional Skull And Bones In Signal Red Colour And Fixed With M.S. Cl S, Bolts And Nuts Of Approved Size, For Ht, 25X20cm Size Complete All As Specified And Directed. , M And L For Cement Concrete In Foundations Filling And Mass Concrete Type D2 1 Etc. - M&L For Cement Concrete In Foundations, Filling And Mass Concrete Type D2 1 4 8 (Using 40Mm Grade Aggregate) , M And L For Pcc 1 3 6 Type C2 Using 40Mm Grade Aggregate As In Foundation Etc. - M&L For Pcc 1 3 6 Type C2 (Using 40Mm Grade Aggregate) As In Foundation For Pole Etc Complete All As Specified And As Directed. , M And L For Pcc 1.2.4 Type B1 Using 20Mm Grade Aggregate Etc. - M And L For Pcc 1.2.4 Type B1 Using 20Mm Grade Aggregate As In Coping For Pole Inclduing Form Work And Finishing The Surfaces Even And Smooth Etc Complete All As Specified And Directed. , M And L For Earthing Complete With Galvanised Steel Earth Plate Electrode 60X60cm Etc. - M And L For Earthing Complete With Galvanised Steel Earth Plate Electrode 60X60cm 6Mm Thick Buried Directly In Ground Earth Pit Not Less Than 2.25 Metres Deep Below Ground Level With Top Edge Of The Plate Not Less Than 15 Metres Below Normal Ground Level Connected To Galvanised Iron Strip 25X4 Mm As Earth Lead Alongwith Gi Protection Pipe By Means Of Bolts Nuts Check Nuts And Washers Of Galvanised Iron Or Steel All As Shown In Electrical Plate No 3 Connected To Earthing Test Point And Pcc Earth Pit And Ci Cover And Funnel With Watering Pipe Wire Mesh Earth Lead Protection Pipe Etc Complete All As Specified Or Indicated Including Testing On Completion. , M And L For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Etc. - M & L For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit/Pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Etc. As Required 32X6 Mm Galvanised Iron Strip Complete , Dismantling Of Acsr Or Aac Conductors , Dismantling Concrete Poles Struts Any Size - Dismantling Concrete Poles/ Struts, Any Size , Dismantling Cross Arms Of M.S. Channel Or Angle Sections Etc. - Dismantling Cross Arms Of M.S. Channel Or Angle Sections Etc. Complete And Setting Aside For Re Use With In 50M , Dismantling Insulators Any Type Any Size - Dismantling Insulators Any Type, Any Size
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Supply laying and testing cable XLPE insulated screened PVC bedded galvanized steel strip or wire etc. | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade, of size 95 sq mm 3 core all as specified and as directed. |
| 2 | Excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth etc. | Excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth getting out in soft/loose soil all as specified and as directed. |
| 3 | Excavation in trenches not exceeding 1.5 m width and exc 1.5m in depth etc. | Excavation in trenches not exceeding 1.5 m width and exc 1.5m in depth getting out in soft/loose soil all as specified and as directed. |
| 4 | Returning filling in including spreading levelling watering and well ramming in layers etc. | Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated soft/loose soil all as specified and as directed. |
| 5 | Removal of surplus soil to a distance not exceeding 50 m and depositing etc. | Removal of surplus soil to a distance not exceeding 50 m and depositing where directed by Engr in charge. |
| 6 | Supply and lay of PCC cable cover class HV type 1 flat size 300mmx180mmx40mm etc. | Supply and lay of PCC cable cover class HV type 1 flat size 300mmx180mmx40mm complete all as specified and directed. |
| 7 | Supply and lay for dry clean dirtless river sand filling for cable protection with a layer of 8cm etc. | Supply and lay for dry, clean, dirtless river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying & punned down to required height, complete all as specified and as directed.Note Only punned thickness shall be measured & paid. |
| 8 | M and L for Double Wall Corrugated DWC High density polyethylene pipes HDPE etc. | M&L for Double Wall Corrugated (DWC) High density polyethylene pipes (HDPE) of 90mm dia laid in trenches for cable protection complete all as spcified and directed. |
| 9 | M and L for fixing GI tubing 80mm dia light grade use for the protection of cable etc. | M&L for fixing GI tubing 80mm dia light grade use for the protection of cable all as specified and directed by Engr in Charge. |
| 10 | M and L for manual boring under road crossing and laying pipe across the road etc. | M&L for manual boring under road crossing and laying pipe across the road for laying cables complete all as specified and as directed. |
| 11 | S and F PCC cable route marker of size 900x300x70mm embossed with HT UG cable etc. | S&F PCC cable route marker of size 900x300x70mm, embossed with HT UG cable 11kV and excavation of 40cm depth, grouted in and including PCC (1 2 4) type B 2 (using 20mm graded stone aggregate) complete all as specified and directed. |
| 12 | Material and labour for steel tubular poles complete with cast iron base palate final taper plug bolts nuts and screws etc. | Material and labour for steel tubular poles complete with cast iron base palate, final taper plug bolts, nuts & screws as specified type 410 SP 55, 11.00 meter long including painting all external exposed steel surfaces with two coats of aliminium paint over a coat of red oxide zinc chrome primer including marking pole numbers in a 15 cm dia yellow circle with number writting with black syenthic paint/ Stricker, including painting strips in alternate from top of coping upto 1.50m height, with three strips of black syenthatic paint & two strips of Yellow/ Sky blue paint (as per existing pattern through out the circumference of pole), including all internal surfaces and external surfaces upto the planting depth shall be painted with two coats of black bitumenous paint complete all as specified and as directed complete all as specified. (Note Earth work, PCC work, shall be measured and paid separately.) |
| 13 | M and L for switch air break gang operated triple pole out door type unit etc. | M & L for switch air break gang operated triple pole out door type unit on HT 11 KV 50 cycle AC suitable for current rating upto 400 Amps mechanically operated mounted on insulators (9 insulators) and frame with operating mechanism worked from ground level with earth switch and including locking arrangement, ACSR conductor complete with taking down old unserviceable complete all as specified and directed. |
| 14 | M and L for 11 kV 200 Amps outdoor type Horn Gap Fuse set conforming to IS 9385 etc. | M & L for 11 kV, 200 Amps, outdoor type Horn Gap Fuse set conforming to IS 9385 (Part I & II) / relevant latest IS standards, complete with galvanized steel horn assembly, suitable fuse element, heavy duty porcelain/polymer insulators, GI channel/angle mounting structure, connectors, clamps, nuts, bolts and all accessories, installed on pole mounted HT structure complete including taking down old unserviceable all as specified and directed. |
| 15 | M and L for cross arms bracing supports clamps and back plates fabricated etc. | M & L for cross arms , bracing, supports , clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size as directed inclusive of 2 coats of aluminium paint over a coat of red oxide primer after dismantling old unserviceable cross arms and complete all as specified and as directed. |
| 16 | M and L for pin type porcelain vitreous brown insulator of size 150mm etc. | M & L for pin type, porcelain, vitreous brown insulator of size 150mm height, 150mm dia 11000 volts grade including one galvanized mild steel spindle with two galvanized iron washers and one galvanized iron nut complete all as specified and as directed. |
| 17 | M and L for lightning arrester surge protector 11 KV grade heavy duty single pole etc. | M & L for lightning arrester/surge protector 11 KV grade heavy duty, single pole, self supporting station, expulsion type class 65 KA capacity with all fittings complete all with taking down old unserviceable all as specified and directed. |
| 18 | S and F Danger notice plate of 1.6mm thick mild steel sheet vitreous enamelled etc. | S & F Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed. |
| 19 | M and L for Cement concrete in foundations filling and mass concrete type D2 1 etc. | M&L for Cement concrete in foundations, filling and mass concrete type D2 1 4 8 (using 40mm grade aggregate) |
| 20 | M and L for PCC 1 3 6 type C2 using 40mm grade aggregate as in foundation etc. | M&L for PCC 1 3 6 type C2 (using 40mm grade aggregate) as in foundation for pole etc complete all as specified and as directed. |
| 21 | M and L for PCC 1.2.4 type B1 using 20mm grade aggregate etc. | M and L for PCC 1.2.4 type B1 using 20mm grade aggregate as in coping for pole inclduing form work and finishing the surfaces even and smooth etc complete all as specified and directed. |
| 22 | M and L for Earthing complete with galvanised steel earth plate electrode 60x60cm etc. | M and L for Earthing complete with galvanised steel earth plate electrode 60x60cm 6mm thick buried directly in ground earth pit not less than 2.25 metres deep below ground level with top edge of the plate not less than 15 metres below normal ground level connected to galvanised iron strip 25x4 mm as earth lead alongwith GI protection pipe by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point and PCC earth pit and CI cover and funnel with watering pipe wire mesh earth lead protection pipe etc complete all as specified or indicated including testing on completion. |
| 23 | M and L for Earth continuity conductor or main earthing lead fixed to wall on batten etc. | M & L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6 mm galvanised iron strip complete |
| 24 | Dismantling of ACSR or AAC conductors | Dismantling of ACSR or AAC conductors |
| 25 | Dismantling concrete poles struts any size | Dismantling concrete poles/ struts, any size |
| 26 | Dismantling cross arms of M.S. channel or angle sections etc. | Dismantling cross arms of M.S. channel or angle sections etc. complete and setting aside for re use with in 50m |
| 27 | Dismantling insulators any type any size | Dismantling insulators any type, any size |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender