Bids Are invited for M And L For Cable In Trenches Or Passing Through Pipe Xlpe Insulated 95 Sqmm 3.5 Core Etc. - M And L For Cable In Trenches Or Passing Through Pipe, Xlpe Insulated, Heavy Duty, Galvanised Steel Strip Or Wire Armoured Electric Lt C
Tender Overview
Project Description
Bids Are invited for M And L For Cable In Trenches Or Passing Through Pipe Xlpe Insulated 95 Sqmm 3.5 Core Etc. - M And L For Cable In Trenches Or Passing Through Pipe, Xlpe Insulated, Heavy Duty, Galvanised Steel Strip Or Wire Armoured Electric Lt Cable With Stranded Aluminium Conductor For 1100 Volts Grade Cross Sectional Area 95 Sqmm 3.5 Core Including Cable Gland And Lugs Including Taking Down Old Unserviceable Cable Complete All As Specified And Directed. , All As Per Item Ser No. 1 Above But Of Size 120 Sqmm 3.5 Core. , Excavating In Trenches Not Exc. 1.50 Mtr Wide And Not Exc. 1.50 Mtr Etc. - Excavating In Trenches Not Exc. 1.50 Mtr Wide And Not Exc. 1.50 Mtr In Depth, Getting Out In Soft / Loose Soil, Complete All As Specified And As Directed. , Returning Filling In Including Spreading Levelling Watering Etc. - Returning, Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exc. 250Mm In Soft/Loose Soil, Complete All As Specified And As Directed. , Removing Excavated Materials Soils Not Exc. 50.00 Mtr Etc. - Removing Excavated Materials (Soils) Not Exc. 50.00 Mtr And Depositing Where Directed At A Level Not Exc. 1.50 Mtr Above The Starting Point In Soil, Complete All As Specified And As Directed. , M And L Sand Cushioning Dry In Trenches For Protection Of Ug Cables Etc. - M And L Sand Cushioning (Dry) In Trenches For Protection Of Ug Cables (Below, Above And Around The Ug Cable Laid In Trenches) Of 230Mm Spread Thickness And Consolidated (Punned) Upto 180Mm Thickness, Complete All As Specified And As Directed. (Note For The Purpose Of Payment, Punned Thickness Of Sand Cushioning Only Shall Be Measured And Paid). , M And L For Fly Ash Bricks Locally Available Laid Dry Width Wise Across The Line Etc. - M And L For Fly Ash Bricks Locally Available Laid Dry Width Wise Across The Line Of Cable In Trenches For Protection Of Ug Cable, Complete All As Specified And As Directed. , S And F Galvanised Iron Pipe 80Mm Bore Dia Light Grade For Protection Of Ug Etc. - S And F Galvanised Iron Pipe 80Mm Bore (Dia) Light Grade For Protection Of Ug Cable, Laid In Floors/ Road Crossing, Fixing To Pole With Mild Steel Cl S, Nuts, Bolts, Etc., Complete All As Specified And As Directed. , S And F Galvanised Iron Pipe 50Mm Bore Dia Light Grade For Protection Etc. - S And F Galvanised Iron Pipe 50Mm Bore (Dia) Light Grade For Protection Of Ug Cable, Laid In Floors/ Road Crossing, Fixing To Pole With Mild Steel Cl S, Nuts, Bolts, Etc., Complete All As Specified And As Directed. , S And F Hdpe Dwc Double Walled Corrugated Of Diameter 63 Mm Etc. - S And F Hdpe Dwc (Double Walled Corrugated) Of Diameter 63 Mm Including Disconnection And Connection Of Cable Near Panel/Oh For Pipe Fixing Including Joints Complete All As Directed. , M And L For Horizontal Boring For Passing Protection Pipe Up To 80Mm Bore Dia Etc. - M And L For Horizontal Boring For Passing Protection Pipe Up To 80Mm Bore (Dia), Under Road /Foot Path, Not Exc. 10.00 Mtr In A Single Length, Complete All As Specified And As Directed. Note Pipe To Be Measured Separately. , M And L For Earthing Complete With Ms Galvanized Plate Of Size 60Cmx60cmx6mm Etc. - M And L For Earthing Complete With Ms Galvanized Plate Of Size 60Cmx60cmx6mm As Earth Electrode , Buried Directly In Ground (Earth Pit Not Less Than 2.25 Mtrs Deep Below Ground Level) With Top Edge Of The Plate Not Less Than 1.5 Mtrs Below Normal Ground Level, Connected To Galvanised Iron Strip 25X4mm As Earthing Lead By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanised Iron/Welding Or Steel All As Shown In Electrical Plate No 3 In Ssr Part I Of 2009 Connected To Earthing Test Point All As Specified Complete With Excavation And Earth Work, Pcc Pit With 50Mm Thick Rcc Cover/Ci /Ms Cover Having Suitable Handle (10Mm Ms Rod) 20Mm Dia Gi Medium Grade Watering Pipe With Gi Funnel With Wire Mesh 40Mm Bore Gi Pipe Medium Grade Isi Marked) For Protection Of Earth Lead Conductor And Testing On Completion Complete All As Specified And As Directed By Engineer In Charge.
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | M and L for cable in trenches or passing through pipe XLPE insulated 95 sqmm 3.5 core etc. | M and L for cable in trenches or passing through pipe, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 95 sqmm 3.5 core including cable gland and lugs including taking down old unserviceable cable complete all as specified and directed. |
| 2 | All as per Item Ser No. 1 above but of size 120 Sqmm 3.5 Core. | All as per Item Ser No. 1 above but of size 120 Sqmm 3.5 Core. |
| 3 | Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr etc. | Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth, getting out in Soft / Loose Soil, complete all as specified and as directed. |
| 4 | Returning Filling in including Spreading Levelling Watering etc. | Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 250mm in Soft/Loose Soil, complete all as specified and as directed. |
| 5 | Removing excavated Materials Soils not exc. 50.00 mtr etc. | Removing excavated Materials (Soils) not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil, complete all as specified and as directed. |
| 6 | M and L Sand Cushioning dry in Trenches for protection of UG Cables etc. | M and L Sand Cushioning (dry) in Trenches for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. (Note For the purpose of Payment, Punned thickness of Sand Cushioning only shall be Measured and Paid). |
| 7 | M and L for fly ash bricks locally available laid dry width wise across the line etc. | M and L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable, complete all as specified and as directed. |
| 8 | S and F Galvanised Iron Pipe 80mm Bore dia Light Grade for protection of UG etc. | S and F Galvanised Iron Pipe 80mm Bore (dia) Light Grade for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. |
| 9 | S and F Galvanised Iron Pipe 50mm Bore dia Light Grade for protection etc. | S and F Galvanised Iron Pipe 50mm Bore (dia) Light Grade for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. |
| 10 | S and F HDPE DWC Double Walled Corrugated of Diameter 63 mm etc. | S and F HDPE DWC (Double Walled Corrugated) of Diameter 63 mm including disconnection and connection of cable near panel/OH for pipe fixing including joints complete all as directed. |
| 11 | M and L for Horizontal Boring for Passing Protection Pipe up to 80mm Bore dia etc. | M and L for Horizontal Boring for Passing Protection Pipe up to 80mm Bore (dia), under Road /Foot Path, not exc. 10.00 mtr in a Single Length, complete all as specified and as directed. Note Pipe to be measured separately. |
| 12 | M and L for earthing complete with MS galvanized plate of size 60cmx60cmx6mm etc. | M and L for earthing complete with MS galvanized plate of size 60cmx60cmx6mm as earth electrode , buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised iron strip 25x4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron/welding or steel all as shown in electrical plate No 3 in SSR Part I of 2009 connected to earthing test point all as specified complete with excavation and earth work, PCC pit with 50mm thick RCC cover/CI /MS cover having suitable handle (10mm MS Rod) 20mm dia GI medium grade watering pipe with GI funnel with wire mesh 40mm bore GI pipe medium grade ISI marked) for protection of earth lead conductor and testing on completion complete all as specified and as directed by Engineer in Charge. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender