Bids Are invited for Mandl For Cable In Trenches Or Passing Through Pipe Xlpe Insulated Heavy Area 70 Sqmm 3.5 Core Etc. - M&L For Cable In Trenches Or Passing Through Pipe, Xlpe Insulated, Heavy Duty, Galvanised Steel Strip Or Wire Armoured Electric
Tender Overview
Project Description
Bids Are invited for Mandl For Cable In Trenches Or Passing Through Pipe Xlpe Insulated Heavy Area 70 Sqmm 3.5 Core Etc. - M&L For Cable In Trenches Or Passing Through Pipe, Xlpe Insulated, Heavy Duty, Galvanised Steel Strip Or Wire Armoured Electric Lt Cable With Stranded Aluminium Conductor For 1100 Volts Grade Cross Sectional Area 70 Sqmm 3.5 Core Including Cable Gland And Lugs Complete All As Specified And Directed. , Mandl For Cable In Trenches Or Passing Through Pipe Xlpe Insulated Heavy Duty Area 95 Sqmm 3.5 Core Etc. - M&L For Cable In Trenches Or Passing Through Pipe, Xlpe Insulated, Heavy Duty, Galvanised Steel Strip Or Wire Armoured Electric Lt Cable With Stranded Aluminium Conductor For 1100 Volts Grade Cross Sectional Area 95 Sqmm 3.5 Core Including Cable Gland And Lugs Complete All As Specified And Directed. , Mandl For Cable In Trenches Or Passing Through Pipe Xlpe Insulated Heavy Duty Area 120 Sqmm 3.5 Core Etc. - M&L For Cable In Trenches Or Passing Through Pipe, Xlpe Insulated, Heavy Duty, Galvanised Steel Strip Or Wire Armoured Electric Lt Cable With Stranded Aluminium Conductor For 1100 Volts Grade Cross Sectional Area 120 Sqmm 3.5 Core Including Cable Gland And Lugs Complete All As Specified And Directed. , Mandl For Cable In Trenches Or Passing Through Pipe Xlpe Insulated Heavy Duty Area 150 Sqmm 3.5 Core Etc. - M&L For Cable In Trenches Or Passing Through Pipe, Xlpe Insulated, Heavy Duty, Galvanised Steel Strip Or Wire Armoured Electric Lt Cable With Stranded Aluminium Conductor For 1100 Volts Grade Cross Sectional Area 150 Sqmm 3.5 Core Including Cable Gland And Lugs Complete All As Specified And Directed. , Mandl For Cable In Trenches Or Passing Through Pipe Xlpe Insulated Area 185 Sqmm 3.5 Core Etc. - M&L For Cable In Trenches Or Passing Through Pipe, Xlpe Insulated, Heavy Duty, Galvanised Steel Strip Or Wire Armoured Electric Lt Cable With Stranded Aluminium Conductor For 1100 Volts Grade Cross Sectional Area 185 Sqmm 3.5 Core Including Cable Gland And Lugs Complete All As Specified And Directed. , Mandl For Cable In Trenches Or Passing Through Pipe Xlpe Insulated Heavy Duty Area 240 Sqmm 3.5 Core Etc. - M&L For Cable In Trenches Or Passing Through Pipe, Xlpe Insulated, Heavy Duty, Galvanised Steel Strip Or Wire Armoured Electric Lt Cable With Stranded Aluminium Conductor For 1100 Volts Grade Cross Sectional Area 240 Sqmm 3.5 Core Including Cable Gland And Lugs Complete All As Specified And Directed. , Mandl For Cable In Trenches Or Passing Through Pipe Xlpe Insulated Area 300 Sqmm 3.5 Core Etc. - M&L For Cable In Trenches Or Passing Through Pipe, Xlpe Insulated, Heavy Duty, Galvanised Steel Strip Or Wire Armoured Electric Lt Cable With Stranded Aluminium Conductor For 1100 Volts Grade Cross Sectional Area 300 Sqmm 3.5 Core Including Cable Gland And Lugs Complete All As Specified And Directed. , Excavating In Trenches Not Exc. 1.50 Mtr Wide And Not Exc. 1.50 Mtr Etc. - Excavating In Trenches Not Exc. 1.50 Mtr Wide And Not Exc. 1.50 Mtr In Depth, Getting Out In Soft / Loose Soil, Complete All As Specified And As Directed. , Returning Filling In Including Spreading Levelling Watering And Well Ramming Etc. - Returning, Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exc. 250Mm In Soft/Loose Soil, Complete All As Specified And As Directed. , Removing Excavated Materials Soils Not Exc. 50.00 Mtr And Depositing Where Directed Etc. - Removing Excavated Materials (Soils) Not Exc. 50.00 Mtr And Depositing Where Directed At A Level Not Exc. 1.50 Mtr Above The Starting Point In Soil, Complete All As Specified And As Directed. , Sandf Galvanised Iron Pipe 100Mm Bore Dia Light Grade For Protection Of Ug Cable Etc. - S&F Galvanised Iron Pipe 100Mm Bore (Dia) Light Grade For Protection Of Ug Cable, Laid In Floors/ Road Crossing, Fixing To Pole With Mild Steel Cl S, Nuts, Bolts, Etc., Complete All As Specified And As Directed. , S And F Hdpe Dwc Double Walled Corrugated Of Diameter 110 Mm Etc. - S & F Hdpe Dwc (Double Walled Corrugated) Of Diameter 110 Mm Including Disconnection And Connection Of Cable Near Panel/Oh For Pipe Fixing Including Joints Complete All As Directed. , S And F Hdpe Dwc Double Walled Corrugated Of Diameter 90 Mm Etc. - S & F Hdpe Dwc (Double Walled Corrugated) Of Diameter 90 Mm Including Disconnection And Connection Of Cable Near Panel/Oh For Pipe Fixing Including Joints Complete All As Directed. , Mandl For Horizontal Boring For Passing Protection Pipe Up To 100Mm Bore Etc. - M&L For Horizontal Boring For Passing Protection Pipe Up To 100Mm Bore (Dia), Under Road /Foot Path, Not Exc. 10.00 Mtr In A Single Length, Complete All As Specified And As Directed. Note Pipe To Be Measured Separately. , Mandl For Earthing Complete With Ms Galvanized Plate Of Size 60Cmx60cmx6mm Etc. - M&L For Earthing Complete With Ms Galvanized Plate Of Size 60Cmx60cmx6mm As Earth Electrode , Buried Directly In Ground (Earth Pit Not Less Than 2.25 Mtrs Deep Below Ground Level) With Top Edge Of The Plate Not Less Than 1.5 Mtrs Below Normal Ground Level, Connected To Galvanised Iron Strip 25X4mm As Earthing Lead By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanised Iron/Welding Or Steel All As Shown In Electrical Plate No 3 In Ssr Part I Of 2009 Connected To Earthing Test Point All As Specified Complete With Excavation & Earth Work, Pcc Pit With 50Mm Thick Rcc Cover/Ci /Ms Cover Having Suitable Handle (10Mm Ms Rod) 20Mm Dia Gi Medium Grade Watering Pipe With Gi Funnel With Wire Mesh 40Mm Bore Gi Pipe Medium Grade Isi Marked) For Protection Of Earth Lead Conductor And Testing On Completion Complete All As Specified And As Directed By Engineerincharge.
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | MandL for cable in trenches or passing through pipe XLPE insulated heavy area 70 sqmm 3.5 core etc. | M&L for cable in trenches or passing through pipe, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 70 sqmm 3.5 core including cable gland and lugs complete all as specified and directed. |
| 2 | MandL for cable in trenches or passing through pipe XLPE insulated heavy duty area 95 sqmm 3.5 core etc. | M&L for cable in trenches or passing through pipe, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 95 sqmm 3.5 core including cable gland and lugs complete all as specified and directed. |
| 3 | MandL for cable in trenches or passing through pipe XLPE insulated heavy duty area 120 sqmm 3.5 core etc. | M&L for cable in trenches or passing through pipe, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 120 sqmm 3.5 core including cable gland and lugs complete all as specified and directed. |
| 4 | MandL for cable in trenches or passing through pipe XLPE insulated heavy duty area 150 sqmm 3.5 core etc. | M&L for cable in trenches or passing through pipe, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 150 sqmm 3.5 core including cable gland and lugs complete all as specified and directed. |
| 5 | MandL for cable in trenches or passing through pipe XLPE insulated area 185 sqmm 3.5 core etc. | M&L for cable in trenches or passing through pipe, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 185 sqmm 3.5 core including cable gland and lugs complete all as specified and directed. |
| 6 | MandL for cable in trenches or passing through pipe XLPE insulated heavy duty area 240 sqmm 3.5 core etc. | M&L for cable in trenches or passing through pipe, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 240 sqmm 3.5 core including cable gland and lugs complete all as specified and directed. |
| 7 | MandL for cable in trenches or passing through pipe XLPE insulated area 300 sqmm 3.5 core etc. | M&L for cable in trenches or passing through pipe, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 300 sqmm 3.5 core including cable gland and lugs complete all as specified and directed. |
| 8 | Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr etc. | Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth, getting out in Soft / Loose Soil, complete all as specified and as directed. |
| 9 | Returning Filling in including Spreading Levelling Watering and Well Ramming etc. | Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 250mm in Soft/Loose Soil, complete all as specified and as directed. |
| 10 | Removing excavated Materials Soils not exc. 50.00 mtr and depositing where directed etc. | Removing excavated Materials (Soils) not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil, complete all as specified and as directed. |
| 11 | SandF Galvanised Iron Pipe 100mm Bore dia Light Grade for protection of UG Cable etc. | S&F Galvanised Iron Pipe 100mm Bore (dia) Light Grade for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. |
| 12 | S and F HDPE DWC Double Walled Corrugated of Diameter 110 mm etc. | S & F HDPE DWC (Double Walled Corrugated) of Diameter 110 mm including disconnection and connection of cable near panel/OH for pipe fixing including joints complete all as directed. |
| 13 | S and F HDPE DWC Double Walled Corrugated of Diameter 90 mm etc. | S & F HDPE DWC (Double Walled Corrugated) of Diameter 90 mm including disconnection and connection of cable near panel/OH for pipe fixing including joints complete all as directed. |
| 14 | MandL for Horizontal Boring for Passing Protection Pipe up to 100mm Bore etc. | M&L for Horizontal Boring for Passing Protection Pipe up to 100mm Bore (dia), under Road /Foot Path, not exc. 10.00 mtr in a Single Length, complete all as specified and as directed. Note Pipe to be measured separately. |
| 15 | MandL for earthing complete with MS galvanized plate of size 60cmx60cmx6mm etc. | M&L for earthing complete with MS galvanized plate of size 60cmx60cmx6mm as earth electrode , buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised iron strip 25x4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron/welding or steel all as shown in electrical plate No 3 in SSR Part I of 2009 connected to earthing test point all as specified complete with excavation & earth work, PCC pit with 50mm thick RCC cover/CI /MS cover having suitable handle (10mm MS Rod) 20mm dia GI medium grade watering pipe with GI funnel with wire mesh 40mm bore GI pipe medium grade ISI marked) for protection of earth lead conductor and testing on completion complete all as specified and as directed by EngineerinCharge. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender