Tender For General-Pmmsy-Upgradation And Modernization Of Puthiyappa Fishing Harbour-Electrification Of Auction Hall And Providing Electric Connection To Mechanical Conveyor System And Automation, Pressure Washer And Cleaning Equipment And Electrific
Tender Overview
Project Description
Tender for General-Pmmsy-Upgradation And Modernization Of Puthiyappa Fishing Harbour-Electrification Of Auction Hall And Providing Electric Connection To Mechanical Conveyor System And Automation, Pressure Washer And Cleaning Equipment And Electrification For Etp.-General Electrical Work
BOQ
| Sl. No. | Item Description |
| 1 | Electrical Work |
| 2 | 1.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group A |
| 3 | 1.10.2:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group B |
| 4 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C |
| 5 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 6 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 7 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 8 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 9 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 10 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 11 | 1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 12 | 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 13 | 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 14 | 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 15 | 1.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 16 | 1.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module |
| 17 | 1.28.4:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module |
| 18 | 90.10.1.3:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface |
| 19 | 90.10.1.5:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )6 module moulded plastic box on surface |
| 20 | 1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 21 | 1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 22 | 1.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm) |
| 23 | 1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) |
| 24 | 1.27.6:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm) |
| 25 | 1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 26 | 1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 27 | 1.41:Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 28 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 29 | 2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Double pole |
| 30 | 2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 31 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 32 | 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 33 | 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 34 | 2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 35 | 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps |
| 36 | 2.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 37 | 5.3:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. |
| 38 | 5.13:Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. |
| 39 | 5.1:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 40 | 5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 41 | 5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 42 | 7.7.1:Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 43 | 7.10:Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
| 44 | 9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) |
| 45 | 9.1.34:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm) |
| 46 | 9.1.35:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm) |
| 47 | 14.2:Excavation for cable trenches of depth upto 1.2 m in soft soil including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres. |
| 48 | 14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement). |
| 49 | 90.3.18.3:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.40 mm dia with clamps made from 20 x 3 mm MS flat |
| 50 | 90.14.10.12:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.160A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC |
| 51 | 90.12.41.32:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp |
| 52 | 90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply |
| 53 | 90.4.10:Conveyance, installation , testing and commissioning of exhaust fans of size up to 450mm in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan. |
| 54 | 90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm |
| 55 | 90.6.6.1:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.1.50 sq mm |
| 56 | 90.12.5.40:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 10 sq mm |
| 57 | 90.12.5.42:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 25 sq mm |
| 58 | 90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp |
| 59 | 90.12.7.42:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp |
| 60 | 90.12.7.43:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 35 sq mm with factory made clamp |
| 61 | 90.12.39.25:Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 120 sq mm |
| 62 | 90.12.39.36:Supply & laying of one number PVC insulated and PVC sheathed armoured copper power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 35 sq mm |
| 63 | 90.12.7.32:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 120 sq mm |
| 64 | 9.1.25:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm) |
| 65 | 9.3.22:Supplying and making straight through joint with cast resin compound including ferrules andother jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm |
| 66 | 90.12.9.2:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size |
| 67 | 90.12.9.3:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench63/50 mm or nearest size |
| 68 | 90.12.9.9:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench145/123 mm or nearest size |
| 69 | 90.14.10.3:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL |
| 70 | 90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 71 | 90.15.4.4:Supply Conveyance, installation, testing and commissioning of 100W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 72 | 90.15.4.7:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 73 | 90.15.4.11:Supply Conveyance, installation, testing and commissioning of 200W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 74 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 75 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 76 | 90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG) |
| 77 | OD2093/2024-2025:Supply and installation of wall mounting cubicle type dust and vermin proof 300x600x170 mm, Hensel make polycarbonate Enclosure - IP66 Mi 0401 or equivalent. |
| 78 | OD5418/2025-2026:Supply and fixing pipe clamping arrangement using 30 cm, 65mm medium GI pipe supported by 50x50x6 mm Angle iron clamped on roof structure using 10 mm anchor bolt 4 nos and additional GI rods for fixing solar street light on builidng including all accessories |
| 79 | OD9237/2024-2025:Supply and installation of wall mounting cubicle type dust and vermin proof size 300x4500x214 mm,or nearest suitable size thermoplastic cable termination box with 25A,16 k A,4P MCCB with rotary handle for MCCB , with all fixing accessories and interconnection with suitably rated copper conductor. Necessary hole for fixing rotary handle in the thermoplastic box is to be provided complete as required as directed by the Engineer In charge at site. |
| 80 | OD9245/2024-2025:Supplying and fixing following way, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, with PE+N terminals, thermoplastic circuit breaker boxes IP65 with metric knock out for cable entry, 1 row 9 module 202 x 238 x 111 or nearest suitable size with PE+N terminals including earthing etc. as required. (But without MCB/RCCB/Isolator) 1 row 9 module with PE+N terminals complete as required. |
| 81 | OD5414/2025-2026:Supplying and fixing following way, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, with PE+N terminals, thermoplastic circuit breaker boxes IP65 with metric knock out for cable entry, 1 row 12 module 295x333x129 or nearest suitable size with PE+N terminals including earthing etc. as required. (But without MCB/RCCB/Isolator) 1 row 12 module with PE+N terminals complete as required. |
| 82 | OD2101/2024-2025:supply Installation testing and commissioning of weather proof LED luminaire having power consumption not more than 36/ 40 W and light output not less than 4500 lm with system efficiency >120 lumens/watt. Luminaire housing made from superior quality of polycarbonate extrusion IP65 and and IK 08 protection. The luminaire should be having minimum 30000 Burning hours with CRI >=80 and co related colour temperature(CCT)of 6500K. complete asrequired. |
| 83 | OD2108/2024-2025:Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of Vertical TPN DB - IP65, Weather proof Polycarbonate , dust protected, , inclusive of 125 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MMCB's (but without MCB's and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 Way including all accessories complete as required. |
| 84 | OD2193/2024-2025:Supplying and fixing following way, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, with PE+N terminals, thermoplastic circuit breaker boxes IP65 with metric knock out for cable entry, 3 row 36 module 295 x 583 x 129 or nearest suitable size with PE+N terminals including earthing etc. as required. (But without MCB/RCCB/Isolator) 1 row 12 module with PE+N terminals complete as required.3 row 36 module. |
| 85 | OD3128/2026-2027:Supply and providing 2.5 mm thick,1m x 2m Synthetic polymer/PVC blend electrical grade Checkered type rubber mat suitable for Medium Voltage installations have IS 15652:2006 Standard ,Class B,Dielectric Strength of 45 kV AC for 1 minute,Self-extinguishing,Anti-skid checkered or dotted top surface and plain at bottom at site complete as required. |
| 86 | OD3129/2026-2027:Supply and providing 4Kg, IS 15683 mark ,stored pressure ABC Powder type Fire Extinguisher with hose and clamps including all fixing accessories and fixing it to wall as directed by Department officials complete as required. |
| 87 | OD3130/2026-2027:Supply and fixing 3mtr long tubular pole made out of 50 mm Diameter (Class B) GI pipe with ISI Mark, on roof slab by using flange and muffings 0.3x.3x.3m near to the column, clamping the pipe to the RCC column using MS clamps made out of 25x5 mm MS flat and anchor bolts, filling the space between slab and pole using PCC 1:11/2:3 (M20), constructing muffing of size 30 cmx30cmx30cm in M20 mix. The top of the pole must be closed with Table E MS flange and dummy flange, bolted with stainless steel nut and bolts and it must have an inverted Y arrangement using 25mm Gl medium pipe 10cm long welded to the pole 10 cm below the top flange to take outgoing wire. The tubular post shall be painted with two coats of epoxy primer and epoxy paint of approved make and colour. |
| 88 | OD3131/2026-2027:Supply and fixing Cable Junction Boxes IP 65 weather proof type for outdoor applications Thermoplastic Polycarbonate ) suitable for cable sizes 2.5 sq.mm , ,80 X 80X 52 mm and accessories for Cable Junction Boxes such as Copper Terminal Set 2.5 sq.mm 5 Pole 1 No,including fixing the accessories using suitable size Stainless steel Bolt and nut, giving necessary connections, making good the damages etc. as required . |
| 89 | OD2113/2024-2025:Supply and fixing of special clamp painted with two coats of enamel paint over a coat of red oxide primer for fixing LED tube fitting in the roof structure using 32x6mm MS flat using 4 Nos of 32mm brass screws etc complete as required |
| 90 | OD2143/2024-2025:Supply and installation of 100w Highbay LED, Bay light , System efficacy is 150 lumens/watt,Designed for operations under diverse environments ranging from -10C to 55C, IK08 polycarbonate cover provides strong protection under harsh conditions, Pressure die-cast housing offers excellent corrosion-resistance and robustness of approved make. |
| 91 | OD2146/2024-2025:Dismantling Existing tubular post of height 12m from foundation ,Conveying, lifting, and erecting tubular post on a RCC footing, using 1:2:4 CC with nominal reinforcement and 6 Nos. of PCC well steining having 0.9m dia and 0.30m height with a muffing of 0.6mx0.6mx1m and 8 numbers of 20mm dia 2.80m long MS foundation bolts having 150mm long standard thread on both ends and 3Nos 20mm and 2Nos 20mm nuts at the top and bottom for each bolt. The post is to be provided with a 20mm thick MS flange of OD 300mm with 8 nos of 20mm bolt holes and a base plate of 600mm square 10mm thick with 8 Nos 20mm dia bolt holes embedded in the concrete 1.8m below ground level. 12mm dia wire rope is to be provided for the entire length of the post as a mechanical support for the cables to the luminaries. Inverted Y arrangement using 50mm heavy GI pipe, flange, and dummy flange cover, and 75mm 4kgf/cm2 PVC pipe with a bend to be provided in the concrete muffing for taking out cables. 8 x 75mm stainless steel Bolt & Nut shall be used for fixing all the flange covers. The post is to be painted with two coats of UV-resistant polyurethane paint of approved quality and color over two coats of best quality industrial epoxy primer and epoxy paint. All MS materials used for fabrication shall be dip galvanized. |
| 92 | OD3132/2026-2027:Supply and installation of wall/structure-mounting cubicle type outdoor Thermoplastic Polycarbonate Mast Foot Box ,Size 4, 315 X 600 X 170mm with opaque/transparent hinged lid, degree of protection IP65/IP66, complete with internal base plate/DIN rails for accommodating 4-Pole RCCB, Isolator, and outgoing 2-Pole MCBs. Box shall include 4 Nos. 35sq.mm channel-mounted Elmex/equivalent terminal connectors suitable for looping up to 16 sq.mm aluminum armoured cables, tin-plated copper earth bus, and necessary IP-rated cable gland knockouts/holes for cable entry and exit. Internal interconnections shall be completed using 2.5 sq.mm flexible copper wiring with insulated pin/fork lugs. The mast foot box supply excludes RCCB and MCBs as required. |
| 93 | OD2327/2024-2025:Engaging labourers for cutting the wall and fixing Switch Board, DB etc.. and restoring the surface neatly as per the instruction form the departmental officers at site. Wireman |
| 94 | OD3133/2026-2027:Engaged Labour for maintenance work for dismounting/fixing the existing light fittings, cables and other electrical accessories from the existing structure including rectifying minor defects, tightening nut and bolts ,overall check-up, change the cable and welding and fabrication work for minor defects including materials complete as directed by engineer in charge at site including all maintenance work complete as required. |
| 95 | OD2195/2024-2025:Fabricating and supplying special clamping arrangement for fixing an asymmetrical beam integral LED flood light on 50 mm dia GI pipe ring with two clamps each made out of 50 x 6mm MS flat and 8x40mm SS nuts and bolts for one luminaire. The clamps are to be linked with 40x6mm MS flat with suitable holes 8mm,10mm, or 12mm size with suitable size SS Bolt& Nut to fix the luminaire. All the items are to be painted with two coats of epoxy-based industrial primer of approved quality and two coats of epoxy paint of approved color as per drawing. |
| 96 | OD2188/2024-2025:Supply and installation of wall mounting cubicle type dust and vermin proof , 315x600x214 mm, hinged type thermoplastic box with 25A,16 kA,TP MCCB with 32A 2 way porcelain neutral link and rotary handle , one set phase indication lamp,2A C-curve MCB - 3 Nos ,Panel surface mounting 96sq.mm backlit LED Multifunction meter three line display to read V,A,KVA,,PF and frequency of make Schneider or equivalent suitable for 415V ,50Hz - 1 No,30/5 tape wound class 1 CT -3 Nos. Sufficient holes for fixing phase indication lamp, multifunction meter and rotary handle in the thermoplastic box are to be provided. Necessary interconnection with suitably rated copper conductor with copper socket are to be provide. |
| 97 | OD2189/2024-2025:Supplying and making end termination nickel plated single compression brass cable gland for 2 core 2.5 sq mm PVC insulated and PVC sheathed armored copper conductor cable 1.1 KV grade, including providing earth clip and superior quality copper cable socket. |
| 98 | OD2190/2024-2025:Supply of 2 core 2.5 sq mm PVC insulated and PVC sheathed armored copper control cable including all expense at site complete as required. |
| 99 | OD3134/2026-2027:Scaffolding Charges for mounting the flood light fixture in existing street light pole upto a length upto 15 mtr from ground level. The charges including hire charge, transportation, loading, unloading and all expense complete as required. |
| 100 | OD9713/2024-2025:Supplying and erecting of PSC pole of length 8 meters with strut having a bottom cross section of 32X10 cm in ground with bottom end at 1.5 meters below ground level as per the instruction from departmental officers at site |
| 101 | OD9715/2024-2025:Supplying and erecting of PSC pole of length 8 meters having a bottom cross section of 32X10 cm in ground with bottom end at 1.5 meters below ground level as per the instruction from departmental officers at site |
| 102 | OD9758/2024-2025:Cleaning and levelling of transformer yard, spreading 40 mm broken stone in yard for a thickness of 10 cm above bed of 10 cm thick 6 mm broken stone, after constructing a curb wall of height 20cm above ground and 10cm below level including cost of all materials and charges for conveying, spreading, consolidating etc. |
| 103 | OD9759/2024-2025:Providing Transformer/RMU fencing to a height of 1.8 m above ground level using MS Angle frames of size ISA 50x50x6mm for outer frame, 2 runs of 40x6 MS flat for horizontal bracing and grills with MS rods 8 mm Dia @ 10cm c/c for verticals, providing gate with locking arrangements, providing danger board & name board, embeding the legs in cement concrete 1:2:4, footing of size 30cmx30cmx50cm, painting with synthetic enamel paint two coats over one coat of iron primer etc complete, incl cost of transportation |
| 104 | OD9761/2024-2025: Supply and Drawing LT Aerial Bunched Cable of size 3X70 + 1X50 +1X16 on 8 M supports with all accessories like Anchor clamp / dead end clamp suitable for LTABC of 50 sq.mm. insulated messenger, Suspension clamp suitable for LT ABC of 50 sq.mm. insulated messenger, Cable tie (each packet contains 100 Nos.),Cable end caps, PVC insulated wire 3.5 C 16/25 sq.mm. for DB connection, Piercing Connector for street light connections, Piercing Connector for DB connection from main ABC to DB, Piercing connector for ABC to ABC Tee connection, Distribution Box 3phase-1 incoming 4 outgoing, Stainless steel strap, steel buckles, Pipe earthing using 40 mm dia GI pipe, 2.5M longwith necessary materials, Pre insulated straight through joints suitable for 70sq mm,50sqmm,16sqmm,Satellite connectors for consumer connection. including labor and transportation charges etc |
| 105 | OD9890/2024-2025:Painting letters or figure of following sizes with enamel paint as identification mark to SB,DB, panel board etc as required. 2.50 cm, 4 cm or 5cm height. |
| 106 | OD9896/2024-2025:Supply installation testing of Three phase 4 wire electronic 5A kwh panel mounting type 96x96mm energy meter fixing in existing panel assembly using fixing aceesories abour charge complete as required. |
| 107 | OD9897/2024-2025:Supply of good quality 33kV hand gloves one pair. Test potential voltage 33000 Volt. Working potential 11000 Volt. Thickness 3.5 mm |
| 108 | OD9898/2024-2025:Supply and installation of wall mounting cubicle type dust and vermin proof, 400 x 300 x 200 mm or nearest suitable size Glass Fibre Reinforced Polyester Enclosure with hinged door, IP66, IK 10 outdoor meterbox or equivalent with base plate for fixing KSEB meter, cut out & Neutral link and 20A , 10kA SPN MCB, C curve , with sufficient holes for fixing KSEB electronic energy meter, cut outs and neutral link. Supply and providing 1No 20A,10kA ,SPN MCB C curve , 1 No 32A HRC fuse units with 20A HRC fuse link and 1No 32A 2way neutral link in the meter portion. Necessary holes are to be provided in the box for entry and exit of wire. The inter connection should be done using 4sq.mm copper wire. |
| 109 | OD9899/2024-2025:Supply and installation of wall mounting cubicle type dust and vermin proof , 400 x 400 x 200 mm Glass Fibre Reinforced Polyester Enclosure with hinged door, IP66, IK 10 outdoor control box or equivalent with base plate .Supply and providing 1No 40A,16kA 4P, MCCB with all fixing accessories labour charge . Necessary holes are to be provided in the box for entry and exit of wire. The inter connection should be done using 4sq.mm copper wire complete as required |
| 110 | OD9900/2024-2025:Supply and providing 25x6 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required |
| 111 | OD9904/2024-2025:Supply and providing FRP 11kV discharge rod of Size18 feet at site including all expense complete as required. |
| 112 | OD9905/2024-2025:Supply and installation of single Phase multifunction kWh Meter in existing panel assembly including all fixing accessories inter connection complete as required. |
| 113 | OD9906/2024-2025:Supply and installation of 3 Phase 4 Wire kWh Meter in existing panel assembly including all fixing accessories complete as required. |
| 114 | OD9909/2024-2025:Supply and providing Wall mounted enclosure 63A receptacle with mechanical interlock IP67 3+N+E Industrial plug socket complete as required |
| 115 | OD5409/2025-2026:Scrapping and cleaning the surface and painting two coats of best quality synthetic enamel paint of approved color over two coat of epoxy based industrial primer on electrical panel and transformer boady including all materials and labour complete as required . |
| 116 | OD9910/2024-2025:Supply, installation, testing and commissioning (SITC) of outdoor type, weatherproof Glass Fibre Reinforced Polyester (GRP/FRP) feeder pillar control box of size 750 mm (H) x 750 mm (W) x 300 mm (D), complete with hinged door, lockable handle with key, heavy-duty continuous neoprene/polyurethane gasket, gland plate, earthing terminals, and internal mounting plate. Enclosure shall have protection rating of IP55 (dust and water jet proof), mechanical impact resistance of IK10, high UV resistance, and flame-retardant properties. Work includes necessary wall mounting / pedestal mounting brackets, masonry fixing / hardware, earthing connection, and all required accessories as per CPWD General Specifications for Electrical Works and as directed by the Engineer-in-Charge. |
| 117 | OD3138/2026-2027:Supply and installation of LED Bulk Head fitting 10W with Aluminum die-cast housing and olycarbonate optic materials including connection, fixing etc complete as required. The luminaire shall have IP66 protection, luminous flux 1100 lm, luminous efficiency 110 lumens/watt, cool daylight colour and 6500k colour temperature .complete as required. |
| 118 | 90.3.19.3:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture |
| 119 | OD9913/2024-2025:Supply and installation of 7 Watt White Reflector LED Ceiling COB Round Spot Light with Focused Beam |
| 120 | OD5429/2025-2026:Supply, testing and delivery at site of heavy duty, single phase AC, sweep length 450 mm exhaust fan, running at approximately 1400 RPM, complete with dynamically balanced metal blades, heavy-duty metallic frame/housing, energy-efficient induction motor, capacitor, wire guard/grille, terminal box, and earthing terminal.The unit shall be suitable for continuous operation on 230 V,50Hz AC power supply, conforming to relevant IS standards (IS 2312) with Class 'E' or Class 'B' insulation, and provided with rust-resistant powder-coated / enamel finish, as per CPWD General Specifications for Electrical Works and as directed by the Engineer-in-Charge. |
| 121 | OD5430/2025-2026:Supply, testing and delivery at site of light duty / domestic axial type exhaust fan, sweep length 250 mm, power rating not exceeding 40 W, running at a speed of approximately 1250 RPM, with a minimum air delivery capacity of 720 CMH complete with high-grade engineering plastic (ABS / Polypropylene) body and aerodynamically designed plastic blades, automatic/gravity shutter/louver, terminal box, internal copper-wound motor, and mounting accessories. The fan unit shall be suitable for continuous single-phase operation on 230 V 50 Hz AC power supply, conforming to relevant Indian Standards (IS 2312) with Class 'E' or Class 'B' insulation, as per PWD General Specifications for Electrical Works and as directed by the Engineer-in-Charge. |
| 122 | OD5480/2025-2026:Supply and installation of wall mounting cubicle type dust and vermin , 600x400x230 mm, thermoplastic box including supply and fixing 250A, 35kA,4pole MCCB with BUC rotory drive kit , 230V ac shunt release ,ELR with CBCT including giving connection using 10.0 sq.mm pvc insulated copper wire, and 2A SPMCB with RYB indication lamp and wiring the circuit with 2.5 sqmm copper wire complete. |
| 123 | OD5481/2025-2026:Supply and installation of wall mounting cubicle type dust and vermin proof size 4 , 600x400x230 mm, Cape make thermoplastic meterbox with provision for fixing KSEB meter.Supply and providing 3 Nos of 250A HRC porcelain fuse units with fuse link and 1No 250A 2way porcelain neutral link in the meter portion and required rating CTs -3 Nos in the meter portion. Necessary holes are to be provided in the box for entry and exit of wire The inter connection should be done using 16.0 sq.mm copper wire. |
| 124 | OD5926/2025-2026:Supply and installation of 3 Phase, 4 wire, CT operated, 240 V, 5-10 A , electronic type energy meter accuracy class 1 |
| 125 | Civil work |
| 126 | 15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 127 | 5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender