Housing Urban and Rular Development Government Departments Closing in 6 days TDR #56659173

Tender For repair maintenance Various E&M Services In Various Delhi Govt. Offices Under Ae(E), Emsd-Ii (South East) Giri Nagar, Kalkaji New Delhi.(Sh:- Electrical Works In Pwd Office Tughlakabad.)

Issued by Government Departments · Delhi, Delhi
Tender Value
11.25 Lakhs
Estimated cost
Bid Submission
01 Aug 2026
6 days left
EMD
22501
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for repair maintenance Various E&M Services In Various Delhi Govt. Offices Under Ae(E), Emsd-Ii (South East) Giri Nagar, Kalkaji New Delhi.(Sh:- Electrical Works In Pwd Office Tughlakabad.)

BOQ

Name of Work:- RMO Various E&M Services in Various Delhi Govt. Offices under AE(E), EMSD-II (South East) Giri Nagar, Kalkaji New Delhi.(Sh:- Electrical Works in PWD office Tughlakabad.)
Sl. No. Item Description
1Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required.
2Group-C
3Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
4Group-C
5Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
620 mm
725 mm
8Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
93 x 1.5 sq. mm
103 x 6 sq. mm
113 x 4 sq. mm
12Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
135/6 amps switch
1415/16 amp switch
153 pin 5/6 amp socket outlet
166 pin 15/16 amp socket outlet
17Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.
183 Module (100mmX75mm)
196 Module (200mmX75mm)
208 Module (125mmX125mm)
21Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required.
22Supplying, Installation, testing and commissioning of 1200 mm sweep ceiling fan including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable suitable for 230 volt 50 Hz AC Supply etc. as required.
23Supplying & Installation of Exhaust Fan 300 mm sweep 900 rpm with shutter and louver in the existing opening including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning suitable for 230 volt 50 Hz AC Supply etc. as required.
24Supplying, installation, testing and commissioning of 200 mm sweeep plastic body Fresh Air Fan having copper wound motor suitable for opertion on 230 volt 50 Hz AC supply complete with shutter and louver in the existing opening/ making the hole to suit the size of the fan, making good the damage, including connection with 3x1.5 sqmm wire complete etc. as required.
25Supplying of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade,internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
2618- 22 watt
27Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with ,70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
2836 watt
29Supplying, installation, Testing & Commissioning of Flood Light, powdercoated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMIEMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time(LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with70% of initial Lumen maintained till life ends as per LM80 extrapolationIES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. system lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink ofaluminum housing such that LED junction temperature shall not rise above 90C
30100 watt
31Supplying and fixing of pole box (195mmx135mmx90MM deep) made out hot moulded SMC with 01no 16amp 3pole connector, din channel and 01 No. 6 Amp SPMCB complete with connections earthing testing etc as reqd.
32Supplying, Laying and fixing of XLPE insulated and PVC sheathed aluminium conductor armoured Power Cable of 1.1 KV grade of following sizes on wall surface etc. as required.
333x10 Sqmm
344x25 Sqmm
35Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthingetc. as required. (But without MCB/RCCB/Isolator)
3612 way , Double door
37Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator).
384 way (4 + 12), Double door
39Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and OperationalVoltage 690V etc. as required.
40200 A,36KA,FPMCCB
41Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
42Single pole
43Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
44Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
45Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
462 X 10 sq. mm + 1 X 6 sq. mm earth wire
47Supplying, installation, testing and commissioning of 450 mm sweeep Wall mounted cabin Fan having copper wound motor suitable for opertion on 220-240 volt 50 Hz AC supply,air delivery of 80-92 CMM,and having 1200-1300 RPM, including connection with 3x1.5 sqmm wire complete etc. as required.
48Supplying and fixing of wire mess structure of size not less then 1Ft x 1 ft x 0.75ft for protection of existing Flood ight installed i/c welding and support clamps etc as required as per direction by engineer-in-charge.
49Supplying Installation Testing and Commissioning of RO System of 50LPH capacity i/c making plubming connection and interconnection with pipe, pipe accessories complete etc as reqd.
50Supplying Installation Testing and commissioning of water cooler with 150ltr storage suitable for operation on 230Volts 10%, 50Hz, single phase AC supply with high efficiency compressor faster cooling, ergonomically desgined for greater safety and operational convenience low power consumption, superior quality grooved copper tubes in heat exchager, ISI marked blue fins on condensor coil, stainless steel body for longer product lift, stainless steel tank food grade water piping float valve and other components which come in contact with drinking water, water inlet, hosepipe, overflow pipe to be provided with water cooler packing adjustable pedestal made of high non corrosive strong material minimum two number etc & interconnection with pipe, pipe accessories complete etc as reqd.
51S.I.T.C of wall mounted busbar chamber of 200 Amp Capcity 6 way 8Horizontal type, Having dimentation of busbar 400X300X150mm. Busbar chamber should fabricated with CRCA sheet and epoxy powder coated with superiour and lasting finish. Busbsr section are made of ETP Grade copper and duly tin plated and busbar supports are made of DMC type and plates are detachable and busbar chamber having suitable incoming and outgoing opening including all connection of cable termination etc as required.
52Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
53Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
5463 mm dia (OD-63 mm & ID-51 mm nominal)
55Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
56Upto 120 sq. mm
57Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required.
58For 14 way, Double door SPN MCBDB
59Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioningetc.as required.
60For 4 way, Double door TPN MCBDB
61Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPEaluminium conductor cable of 1.1 KV grade as required.
623 X 10 sq. mm (22mm)
634 X 25 sq. mm (28mm)
64Providing and fixing of chemical Earthing to enhance the earth conductivity comprising of 25 mm Dia, 3 Mtr, 250 Micron copper coated Rod earth electrode, chemical compound (25 Kg, Suitable for 2-3 Meter depth earth rod)-2 bags, clamps Universal clamp (SS), 25 mm and chamber (under floor earth inspection pit) etc as required and as per direction of engineer-in charge.
65Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
66Credit for dismantle materials
67Ceiling Fan / Wall fan
68Assorted LED Fittings
69Assorted Copper Wire with insulation
70Assorted Conduit
71Assorted Switch / Regulator Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56659173
AUTHORITY Government Departments
TENDER VALUE 11.25 Lakhs
LAST DATE 01-08-2026
Authority
Authority Name Public Works Department
Work Description Tender for repair maintenance Various E&M Services In Various Delhi Govt. Offices Under Ae(E), Emsd-Ii (South East) Giri Nagar, Kalkaji New Delhi.(Sh:- Electrical Works In Pwd Office Tughlakabad.)
Basic Detail
Tender No 75/EE(E)/EMD South East/PWD/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 25 Jul 2026
Submission Date 01 Aug 2026
Open Date 01 Aug 2026
Finance
Tender Value 11.25 Lakhs
Tender Fee Ref. Documents
EMD 22501
Exemption Not Available
Document List
9f9f23d9-29fa-46c4-bc39-80554d0c6fac.html
BOQ_393766.xls
tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 25, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Aug 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

9f9f23d9-29fa-46c4-bc39-80554d0c6fac.html

xls

BOQ_393766.xls

pdf

tender.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender