Tender For Supply, Installation, Testing And Commissioning Of Ht Electrical Infrastructure Including Transformer At Convention Hall, Janmanch, Saharanpur
Tender Value
35.18 Lakhs
Estimated cost
Bid Submission
24 Aug 2026
23 days left
EMD
70500
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Saharanpur → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Supply, Installation, Testing And Commissioning Of Ht Electrical Infrastructure Including Transformer At Convention Hall, Janmanch, Saharanpur
BOQ
| Sl. No. | Item Description |
| 1 | STP 11 MTR LONG SP-55 |
| 2 | 11 KV POLYMERIC PIN INSULATOR |
| 3 | 11 KV PIN WITH NUT |
| 4 | 11KV DISC INSULATOR |
| 5 | 11KV DISC FITTING |
| 6 | 11KV 3*120SQ MM XLPE CABLE |
| 7 | 11KV CABLE J/KIT I/D 3*120 SQ MM |
| 8 | 11KV CABLE J/KIT O/D 3*120 SQ MM |
| 9 | 11KV MET. CUB. PILFER PROOF 20/5A |
| 10 | 11KV MET, UNIT Pole Mounted CT/PT 20/5A |
| 11 | M.S CHANNEL 100*50*6 MM |
| 12 | M.S ANGLE 65*65*6 MM |
| 13 | ACSR DOG CONDUCTOR |
| 14 | 250 KVA T/F 11/0.4 KV NEW |
| 15 | 11KV VCB O/G 200/100/5A |
| 16 | STAY ROD 16*1800MM |
| 17 | STAY WIRE 7/10 SWG |
| 18 | EARTHING ROD 2540*20MM |
| 19 | G.I PIPE 6 DIA |
| 20 | 11KV TPMO WITH POLYMERIC INSULATOR |
| 21 | 11KV FUSE SET |
| 22 | LT XLPE CABLE 1*400 SQMM |
| 23 | PVC 1*25 SQMM CABLE XLPE |
| 24 | HOLDING CLAMPS |
| 25 | RED OXIDE PAINT |
| 26 | ALLUMINIUM OXIDE PAINT |
| 27 | DANGER BOARD WITH CLAMP |
| 28 | BARBED WIRE |
| 29 | NUMBER PLATE |
| 30 | M.S NUT & BOLTS |
| 31 | STONE PAD 300*300*75MM |
| 32 | ALL. LUGS 400 SQMM |
| 33 | GROUTING OF POLE |
| 34 | WATER LEVEL EARTING OF METERING CUBICLE AND VCB PANEL AND T/F, CT/PT |
| 35 | PLINTH FOR PROPOSED T/F |
| 36 | FENCING FOR PROPOSED T/F |
| 37 | PG CLAMP FOR DOG |
| 38 | COMPLETE EARTHING OF STP POLE |
| 39 | CONCRETING OF STAY |
| 40 | COPPER L-PIECE 50x25x10 mm |
| 41 | TAIL LESS UNIT WITH COVERED BOX FOR 250 KVA T/F |
| 42 | DIGGING & LAYING OF 11 KV CABLE (DOUBLE CKT) |
| 43 | LAYING OF 11KV CABLE IN AIR |
| 44 | MAKING OF J/KIT |
| 45 | CABLE ROUTE MARKER |
| 46 | SUPPLY OF HDPE PIPE PE-80, PN-6, DN-200MM DIA PIPE FOR LAYING OF 11KV, 3*185 SQ.MM |
| 47 | LAYING CHARGE OF HDPE PIPE THROUGH TRENCHLESS METHOD |
| 48 | Earth work in excavation by mechanical means / manual means over areas... 2.6.1 All kinds of soil (DSR 2.6.1) |
| 49 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. DSR 2.25 |
| 50 | Cement Concrete with 4 cm gauge approved tone ballast, coarse sand & cement in the proportion of 4:2:1... (SOR-23 item number 5.08) Same as above item number but in proportion of 1:4:8 |
| 51 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floor, roofs, landings... (DSR-23 Item No. 5.9.3) |
| 52 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick (DSR-23 Item No. 5.9.5) |
| 53 | Providing and laying in position ready mixed or site batched design mix cement concrete... Concrete of M25 grade with minimum cement content of 330 kg/cum (DSR-23 Item no 5.33.1) |
| 54 | All works above plinth level upto floor V level 1 Concrete of M25 grade with minimum cement content of 330 kg/cum (DSR-23 Item no 5.33.2) |
| 55 | Steel reinforcement for R.C.C. work including straightening, cutting, bending... Thermo-Mechanically Treated bars of grade Fe-500D or more. (DSR-23 Item 5.22A.6) |
| 56 | Add for plaster drip course/ groove in plastered surface or moulding to 1.21 R.C.C. projections. (DSR-23 Item 5.30) |
| 57 | Brick work with common burnt clay F.P.S. bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (DSR-23 Item 6.1.1) |
| 58 | Brick work with common burnt clay F.P.S. bricks of class designation 7.5 in superstructure above plinth level... Cement mortar 1:4 (DSR -23 Item 6.4.1) |
| 59 | 4.0 cm (1\\") thick 1:2:4 plain cement concrete floor with cement, approved coarse sand and 2 cm...As in item (601) above but floor shall be 4 cm (1.5\\") thick instead of 2.5 (1\\") thick and without base concrete(SOR 2022-14.05-603) |
| 60 | 20 mm cement plaster of mix: 13.3.1 1:4 (1 cement: 4 fine sand) (DSR -23 Item 13.3.1) |
| 61 | 15 mm cement plaster on the rough side of single or half brick wall of mix: 13.2.1 1:4 (1 cement: 4 fine sand) (DSR-23 Item 13.2.1) |
| 62 | Wall painting with acrylic emulsion paint... Two coats (DSR-23 Item 13.82.2) |
| 63 | Applying priming coats with primer of approved brand and manufacture... (DSR-23 Item 13.85.3) |
| 64 | Providing and applying white cement based putty of average thikness 1 mm…........... (DSR -23 item 13.80) |
| 65 | Painting or varnishing work in small areas or new wood work with one coat... (SOR-22 Sr no.15.01 Item No. 641 |
| 66 | As in item (641) above but for every coat after first coat (SOR-22 Sr no.15.02 Item No. 642 |
| 67 | Supplying and fixing following modular switch/socket on the existing modular plate... 5/6 A switch |
| 68 | Supplying and fixing 5 A to 32 A rating, 240/415 V... Single pole Each 285 |
| 69 | Supplying and fixing 5 A to 32 A rating... Double pole Each 696 |
| 70 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR... (dsr 1.10.2) |
| 71 | supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board... 6 way, Double door (dsr 2.3.1) |
| 72 | Supplying and making end termination with brass compression gland and aluminium lugs... 3.5 X 240 sq. mm (62mm) |
| 73 | Supplying and making outdoor end termination with cast resin compound including aluminium lugs... 3.5 X 240 sq. mm |
| 74 | Supplying and fixing metal box of following sizes... 75 mm X 75 mm X 60 mm |
| 75 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate... 1 or 2 Module (75mmX75mm) |
| 76 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor... 2 x 2.5 sq. mm |
| 77 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor... 1 x 1.5 sq. mm |
| 78 | Supplying and fixing of following sizes of medium class PVC conduit... 25 mm |
| 79 | LED Batten light... Supplying, Installation, of LED surface mounted Batten light... (DSR 8.9.1) |
| 80 | 3.1 Supplying Installation, Testing and Commissioning of on wall... rising mains... (DSR 3.1.3)400 A (S.C. rating for 1 sec-25 kA) Meter 9907 |
| 81 | Exhaust Fans Supply, Installation & Testing of following 900 RPM heavy duty exhaust fan... 300mm Sweep |
| 82 | Excavating trenches by mechinical / manual means of required width for pipes, cables, etc... All kinds of soil (DSR-23 Item 2.10.1.1) |
| 83 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.1. fittings... (i) 80 mm dia |
| 84 | Providing and laying \\"brick coba\\" 12mm thick laid with M 150 class brick bat coba 7.50 cm thick... |
| 85 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work… |
| 86 | Labour Charges 1% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 23 daysAug 25, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 24 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender