Tender For Work Of Installing Air Conditioning Plants In The Court Rooms And Rest Rooms Of The District Judge And Additional District Judge In The District Court Kasganj Complex.
Tender Overview
Project Description
Tender for Work Of Installing Air Conditioning Plants In The Court Rooms And Rest Rooms Of The District Judge And Additional District Judge In The District Court Kasganj Complex.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 29-Jul-2026 | Other | Other | 01-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | PART-A (AC WORK)Supplying,Installation,Testing and Commissioning of Air Cooled Hi wall split type Air conditioners complete with Indoor unit ,Outdoor Unit,surface/concealedcopper refrigerant piping with insulation( closed cell elastomeric nitrile rubber tubular pipe section upto 3 mtr ( IDU to ODU ) , copper powder cable upto 3.5 mtr ( IDU to ODU ) i/c drain pipe R-32/R-410/R-407 Green Refrigerant wireless Remote control suitable for working between 180-260 V with low & high voltage cutoff and 50hz,1 phase AC supply capable of performing cooling,dehumidification , air circulation of following capacity with Scroll/ rotary compressor. The system shall be able to deliever 100% of the rated capacity upto 42degree C. Min 5 year Original Equipment manufacture ( OEM) warranty both compressor and printed circuit Board ( PCB ). Must comply: Electrical cable IS 694 or 9968 temperature sensing control IS / international Electrotechnical Commission ( IEC ) 60730, hermetic compressor IS 10617 , heat exchanger IS 11329 capacitor IS 2993 and motor IS 12615. Complete as per CPWD specifications ans IS: 1391 part II 2023. The system shall be able to operate upto 52 degree ( Outdoor ambient temperature ) Inverter Type - Cooling only 1.5 TR with 5 starBEE Rating |
| 2 | Supplying,Installation,Testing and Commissioning of Air Cooled Hi wall split type Air conditioners complete with Indoor unit ,Outdoor Unit,surface/concealedcopper refrigerant piping with insulation( closed cell elastomeric nitrile rubber tubular pipe section upto 3 mtr ( IDU to ODU ) , copper powder cable upto 3.5 mtr ( IDU to ODU ) i/c drain pipe R-32/R-410/R-407 Green Refrigerant wireless Remote control suitable for working between 180-260 V with low & high voltage cutoff and 50hz,1 phase AC supply capable of performing cooling,dehumidification , air circulation of following capacity with Scroll/ rotary compressor. The system shall be able to deliever 100% of the rated capacity upto 42degree C. Min 5 year Original Equipment manufacture ( OEM) warranty both compressor and printed circuit Board ( PCB ). Must comply: Electrical cable IS 694 or 9968 temperature sensing control IS / international Electrotechnical Commission ( IEC ) 60730, hermetic compressor IS 10617 , heat exchanger IS 11329 capacitor IS 2993 and motor IS 12615. Complete as per CPWD specifications ans IS: 1391 part II 2023. The system shall be able to operate upto 52 degree ( Outdoor ambient temperature ) Inverter Type - Cooling only 2.0 TR with 5 Star BEE Rating |
| 3 | SITC of suction/discharge both Copper pipe line in split A.C unit upto 2.0 toncapacity including brazing,nitrile,rubber insulation 6 mm thick class\\"O\\" etc.complete 3/8\\"(9.50 mm) and 5/8\\" (15.90mm) |
| 4 | SITC of suction/discharge both Copper pipe line in split A.C unit upto 1/1.5 toncapacity including brazing,nitrile,rubber insulation 6 mm thick class\\"O\\" etc.complete 1/2\\"(12.70 mm) and 1/4\\" (6.40mm) |
| 5 | Supply of wall mounted copper wounded Voltage stablizer 5 KVA Capacity |
| 6 | Supply of wall mounted copper wounded Voltage stablizer 4 KVA Capacity |
| 7 | Supply and laying of heavy duty CPVC 20mm/25mm OD pipe for condensed water with clipping accessories complete |
| 8 | S/F of Inter connecting Electrical cable for A.C ( 2.5 Sq. mm 3 core ) for Indoor to Stablizer connection |
| 9 | S/F of Inter connecting Electrical cable for A.C ( 2.5 Sq. mm 4 core ) for Indoor to outdoor connection |
| 10 | Fabrication of M.S stand for Outer unit of A.C withfixing on wall with all material & labour complete in all respect |
| 11 | Supply and fixing of door closer in aluminium body Complete in all respect |
| 12 | Supply Fabrication and intallation of M S Cage for protection of Outdoor AC unit from theft/animal L*W*H 1300mm*600mm*1200mm complete |
| 13 | PART-B (Electrification Work)S/F of following ways surface/recess mounting , verticle type,415 volt ,VTPN MCB distribution board of sheet steel , dust protected ,dully powder painted inclusive of 200 amps tinned copper bus bar,common neutral link,earth bar,din bar for mounting MCB's( but without MCB's and incommer) as required . 4 way (4+12) Double door |
| 14 | S&F of 5 Amp-32 Amp rating . 240/415 volts \\"C\\" curve SP MCB (10 KA). |
| 15 | S&F single Pole MCB blanking plate. CAT-A |
| 16 | Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. Incoming 630A MCCB Type - 1 No. Outgoing 63 A MCCB-12 Nos.CAT-B Cubical Type |
| 17 | Incoming 100A MCCB Type - 1 No. Outgoing 63Amp MCCB-02 Cat B Cubical Type |
| 18 | Wiring for circuit/submain wiring along with earth wire with FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit as required . Size (2X6 sq.mm +1X6 sq. mm as earth) |
| 19 | Earthing with G.I earth Plate 600x600x6 mm thick including all material providing masonary with cover plate having locking arrangement and watering pipe 2.7 mtr.long with charcoal/coal and salt as required |
| 20 | S/F of Suitable size of GI Box with modular plate and cover in front on surface or in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB C curve complete with connections, painting etc as required. |
| 21 | Supply and laying of 25mm x 5mm G.I. strip from earth electrode directly in the ground as required complete in all respects. |
| 22 | S/ Laying of Al conductor PVC insulated Armoured Cable 1100 V grade 25 sq. mm 3.5 core. |
| 23 | S/ Laying of Al conductor PVC insulated Armoured Cable 1100 V grade 35sq. mm 3.5 core. |
| 24 | S/ Laying of Al conductor PVC insulated Armoured Cable 1100 V grade 400 sq. mm 3.5 core. |
| 25 | S/M end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required. 4X25 sq.mm ( 28 mm ) |
| 26 | 3.5X95 sq.mm ( 45 mm ) |
| 27 | 3.5X400 sq.mm ( 82 mm ) |
| 28 | Supply and Fixing of plainor pintype copper tin plated cable socket (lug) to the cable leads complete sixe 6 sqmm |
| 29 | S/F of 16amp /240 V 3pin plug top with indicator (H.D.) |
| 30 | S/F of 40/63 Amp 4 pole MCCB (10KA) C Curve |
| 31 | L/C for R.C.C road cutting with repair as previous surface including all material & labour |
| 32 | Supply and laying of 1800mm x 900mm x 12mm thick chequered rubber matting of tested quality. |
| 33 | Supply and fixing of Shock Treatment Chart (Prescribed under I.E. rules) duly framed with glass and supported from back with hard board or soft board with supply of all material labour T&P for proper completion of work. |
| 34 | Supply and fixing of 630 Amp 415 V Heavy duty double break HRC Fuse type metal clad TPN complete with HRC fuse etc on angle iron frame as like Main switch Complete in all respect |
| 35 | Supply and fixing of 100 Amp 415 V Heavy duty double break HRC Fuse type metal clad TPN complete with HRC fuse etc on angle iron frame as like Main switch Complete in all respect |
| 36 | Supply and fixing of fire extinguisher CO2 type 4.50 kg capcity (ISI marked IS:2878 & TAC approved). Complete with initial charge and wall bracket . Complete in all respect |
| 37 | Supply and fixing of fire extinguisher ABC type 4.00 kg capcity (ISI marked IS:15683& TAC approved). Complete with initial charge and wall bracket . Complete in all respect |
| 38 | Name writing on main panels, sub panels, TPN DB Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 1 dayBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender