Project Description
Tender for Installation Of Air Conditioners In The Courts And Chambers Of The District Judge And Additional District Judges (19 Courts/04 Family Court Buildings) At The District Court Bulandshahr
BOQ
| Sl. No. | Item Description |
| 1 | SITC of split 1.5 Tr air cooled high wall split type AC complete with indoor unit, outdoor unit surface/concealed copper refrigerant pipe with insulation (closed cell elastomeric nitrile rubber tuluble pipe section.) upto 3 Mtr (IDU to ODU) I/c drain pipe R-32/R-410/R407 Green Refrinerant, woreless Remote control, suitable for working between 180-260V with low & high voltage outoff and 50 Hz 1 phase AC supply capable of performing cooling. dehumidification, air circulation of following capacity with Scroll/rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 OC Min 5 year original equipment manufacturer (OEM) warranty both compressor and printed Circuit board (PCB) Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical commission (IEC) 60730. Hermetic compressor IS 10617, Heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615, complete as per CPWD specification and IS : 1391 Part-II 2023, The system shall be able to operate upto 52 OC (Ourdoor ambient temperature). complete as per direction of Engineer In Charge. |
| 2 | SITC of split 2 Tr air cooled high wall split type AC complete with indoor unit, outdoor unit surface/concealed copper refrigerant pipe with insulation (closed cell elastomeric nitrile rubber tuluble pipe section.) upto 3 Mtr (IDU to ODU) I/c drain pipe R-32/R-410/R407 Green Refrinerant, woreless Remote control, suitable for working between 180-260V with low & high voltage outoff and 50 Hz 1 phase AC supply capable of performing cooling. dehumidification, air circulation of following capacity with Scroll/rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 OC Min 5 year original equipment manufacturer (OEM) warranty both compressor and printed Circuit board (PCB) Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical commission (IEC) 60730. Hermetic compressor IS 10617, Heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615, complete as per CPWD specification and IS : 1391 Part-II 2023, The system shall be able to operate upto 52 OC (Ourdoor ambient temperature). complete as per direction of Engineer In Charge. |
| 3 | SITC of 4 KVA Voltage Stablizer for Air Conditioner Upto 1.5TR (130-300 Range) with copper winding, complete in all respect as per direction of Engineer in charge. |
| 4 | SITC of 5 KVA Voltage Stablizer for Air Conditioner Upto 2TR (130-300V Range) copper winding complete in all respect (Make- V-Guard or Equivalent) as per direction of Engineer in charge. |
| 5 | SITC OF Suction/Discharge copper pipe line in split A.C. Unit 1.5 Ton Capacity including brazing, nitrile, rubber insulation 6mm thick class 'O' etc complete 1/4\\" (6.40 mm) and 1/2\\" (12.70 mm) complete in all respect. |
| 6 | SITC OF Suction/Discharge copper pipe line in split A.C. Unit 2.0 Ton Capacity including brazing, nitrile, rubber insulation 6mm thick class 'O' etc complete 3/8\\" (9.50 mm) and 5/8\\" (15.90 mm) complete in all respect. |
| 7 | S/F of Angle iron stand for outdoor unit of 1.5 and 2.0 TR Split Air Conditioners. Complete in all respect. |
| 8 | S/F of 2.5 sq. mm 4 Core flexible copper Lead for connectiong indoor to outdoor unit. |
| 9 | S/F of 2.5 sq. mm 3 Core flexible copper Lead for stabilizer |
| 10 | Providing and fixing CPVC Pipe including all fittings 25mm dia including all material labour etc. complete in all respect for drain water. |
| 11 | Supply, fabrication and installation of MS cage for protection of outdoor unit from animal/theft L × W × H = 1300mm × 600mm × 1200mm. Complete in all respect. |
| 12 | Providing and fixing PVC Casing Caping including all material labour etc. complete in all respect for copper piping covering. |
| 13 | Supply and laying of aluminium conductor PVC installed armoured served cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of sutable size or as directed by the Engineer incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. (p) 400 sq. mm 3-1/2 Core. |
| 14 | Supply and laying of 70 sq. mm 3-1/2 Core PVC insulated and PVC sheathed/XLPE powder cable of 1.1 KV grade of size on wall surface. Complete in all respect. |
| 15 | Supply and laying of 25 sq. mm 3-1/2 Core PVC insulated and PVC sheathed/XLPE powder cable of 1.1 KV grade of size on wall surface. Complete in all respect. |
| 16 | Wiring of circuit/submain wiring along with earth wire with the size 4x16sq.mm + 2x6sq.mm earth wire of FRLS PVC insulated copper conductor, four core cable in surface/recessed heavy duty PVC conduit as required. |
| 17 | Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required.Size :- 400 sq. mm × 3 1/2 core. |
| 18 | Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required.Size :- 70 sq. mm × 3 1/2 core. |
| 19 | Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required.Size :- 50 sq. mm × 3 core. |
| 20 | Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required.Size :- 16 sq. mm × 4 core. |
| 21 | Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required.Size :- 6 sq. mm × 2 core. |
| 22 | Supply and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required.Size :- 6 sq. mm × 2 core. |
| 23 | SITC of LT Panel Fabrication out of 2.0/1.6mm thick CRCA sheet steel, painted with powder coated paint of shade as per the direction of Engineer Incharge after proper sheet treatment process of sheet steel. The Bus bar of panel shall be of Electrical grade High condutive Aluminium alloy of appropriate cross section as per rating. The main bus bar throughout the panel of rating as main incomer rating. The Bus Bas shall be supported by non hygroscopic SMC/DMC Bus bar supports which shall be mounted on proper interval to ensure the bear the jerks of short Circuit of 50 KA for panels having ABC as incomer & 36 KA for panels having MCCB incomers. Panle shall be constructed in fully Segregated compartment Design of Each feeder as per 3b construction Format. The Panel shall be completed in all respect as per IS:8623 Part 2 & 3. There shall be separate metering compartment for incomer Metering and outgoing Metering can be provided in switchgear Feeder also. All incomer Feeders shall be provided with multifunction Metering along with phase indicating Lights and other asso associated components such as CT, control MCB Terminal Block etc. The feeders above shall be provided ac accommodated all measuring instruments shall be Digital type & all including lights shall be LED type. Wiring shall be done from 1100V Grade PVC insulated copper flexible wire. All ACB shall be Electricity operated Draw-out type with microprocessor based O/L, S/C & E/F Release of Breaking/with stand capacity (ICU/ICs/Icw) 50KA or more all MCCB shall be Thermal Magneetic/Microprocessor with O/L, S/C & E/F protection along with required Spreaders & Extended Rotary Handle with pad Locking facility of Breaking capacity (ICU/ICS) 35 KA or more all MCB shall be thermal 10 KA 'C' Curve. complete in all respect Cubcial Panel. CAT-B Incoming 800 Amp, ACB Outgoing 200 Amp MCCB 03 No. 100 Amp MCCB 01 No. & 63Amp MCCB 02 No. |
| 24 | S/F of 4 way (4 + 12), Double door surface/recess mounting vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A din bar for mounting MCBs. complete in all recpect, as directed at side by Engineer in charge. CAT-A |
| 25 | S/F of surface/flush mounting 4 ways TPN distribution board with additional door without MCCB complete in all recpect, as directed at side by Engineer in charge. CAT-A |
| 26 | S/F of 6 Amp. To 32 Amp SP MCB (10 KA). CAT-A |
| 27 | S/F of 125 Amp. 4 pole MCCB (36 KA). CAT-A |
| 28 | S/F of 63 Amp. 3 pole MCB (10 KA). CAT-A |
| 29 | S/F of 63 Amp 4 pole MCB (10 KA) |
| 30 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required |
| 31 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 32 | Supply and Laying of GI pipe 100 mm dia complete in all respect. |
| 33 | Supply and fixing 20A, 240V SPN industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20A \\"C\\" curve, SP MCB in sheet steel enclosure, on in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 34 | Supply and wiring of submain with 2 No. 6 sq.mm PVC insulated 1100V grade multistrand single core copper conductor cable in 25 mm dia heavy duty PVC conduit with One No. 4 sq.mm FR PVC insulated 1100V grade multistrand single core copper conductor as earth continuity wire drawn in concealed conduit complete in all respect. |
| 35 | SITC of 4 KVA Voltage Stablizer for Air Conditioner Upto 1.5TR (130-300 Range) with copper winding, complete in all respect as per direction of Engineer in charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 25, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysAug 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender