Bids Are invited for Taking Down Of Light Fittings Of Any Type Size And Model Etc. - Taking Down Of Light Fittings Of Any Type Size And Model Complete All As Specified And Directed. , Taking Down Of Brackets Of Any Type Size And Model Etc. - Taking D
Tender Overview
Project Description
Bids Are invited for Taking Down Of Light Fittings Of Any Type Size And Model Etc. - Taking Down Of Light Fittings Of Any Type Size And Model Complete All As Specified And Directed. , Taking Down Of Brackets Of Any Type Size And Model Etc. - Taking Down Of Brackets Of Any Type Size And Model Complete All As Specified And Directed. , Dismantling Steel Poles Struts Of Any Size And Removing Off The Site Etc. - Dismantling Steel Poles/Struts Of Any Size And Removing Off The Site Complete All As Specified And Directed. , Taking Down Out Unserviceable Ug Cables Of Any Cross Sectional Area Etc. - Taking Down/Out Unserviceable Ug Cables Of Any Cross Sectional Area And Connections Including Bricks, Gi Pipes, Etc. Of Any Descriptions, Laid In Trenches And/Or Fixing With Walls/Poles Including Segregating Of Serviceable Materials Viz Bricks, Cables, Gi Pipes, Etc. And Keep In Safe Custody For Re-Use, Complete All As Specified And As Directed. , Material And Labour For Steel Tubular Poles Complete With Cast Iron Etc. - Material And Labour For Steel Tubular Poles Complete With Cast Iron Base Palate, Final Taper Plug Bolts, Nuts & Screws As Specified Type 410 Sp-22 8.50 Meter Long Including Painting All External Exposed Steel Surfaces With Two Coats Of Aliminium Paint , S And F Cable Junction Box 155X210x92 Mm In Size Made Out Of Thermoplastic Etc. - S&F Cable Junction Box 155X210x92 Mm In Size, Made Out Of Thermoplastic, Having Ip 66 Protection For Outdoor Installation Fixed With 4 Way Bakelite Cable Terminals Including 03 Nos Polymide Gland With Check Nut (M-32 -02 No & M-25 -01 No) Fixed On Poles With Aluminium Cl S Of Size 25X3mm, Nuts, Bolts, Washers Etc. Including Taking Out Of Old Unserviceable Cable Junction Box Complete All As Specified And As Directed. , Supply And Passing Through Steel Tubler Pole Service Connection Etc. - Supply And Passing Through Steel Tubler Pole/Service Connection, 1100 Volts Grade Multicore,Fr, Round Insulated Copper Conductor And Sheathed Flexible Cable,Multistranded, Three Core Of Nominal Cross Sectonal Area 1.5 Sq Mm,For Connection Of Security Light From Junction Box Through Pole /Conduit With All Terminals Complete All As Specified And As Directed. , S And F Singlearmbracketmadeof40mmdia10mtrlong For Security Light - S And F Singlearmbracketmadeof40mmdia10mtrlong For Security Light With Mounting Ms Cl Of Flat Iron Size 25X5 Mm Of Suitable Length 02 Pairs Including Nut Bolts Etc Of Suitable Size And Painting To Ms Cl With Two Coats Of Aluminium Paints Over A Coat Of Red Oxide Metal Primer All As Specified And Directed By Engr In Charge , M And L For Earthing Complete With Galvanised Steel Earth Plate Electrode Etc. - M&L For Earthing Complete With Galvanised Steel Earth Plate Electrode Size 600 X 600 X 6 Mm Thick, Burried Directly In Ground, (Earth Pit Not Less Than 2.25 M Deep Below Ground Level) With Top Edge Of The Plate Not Less Than 1.5 M Below Ground Level Connected To Galvanised Iron Strip 32 X 6 Mm As Earthin Lead Wire By Means Of Bolts, Nuts, , Excavating In Trenches N.Exc 1.5 M Wide And N.Exc 1.5 M Depth Etc. - Excavating In Trenches , N.Exc 1.5 M Wide And N.Exc 1.5 M Depth For Foundation Etc Or For Shafts, Wells, Cesspits ,Manhole Pier Hole, Laying Of Cables, Pipes Etc N.Exc 10 Sqm On Plan And N.Exc 1.5M In Depth And Getting Out In Any Kind Of Soil , Returning Filling In Including Spreading Levelling Watering And Well Ramming Etc. - Returning, Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exc. 250Mm In Soft/Loose Soil, Complete All As Specified And As Directed. , Removing Excavated Materials Soils Not Exc. 50.00 Mtr Etc. - Removing Excavated Materials (Soils) Not Exc. 50.00 Mtr And Depositing Where Directed At A Level Not Exc. 1.50 Mtr Above The Starting Point In Soil, Complete All As Specified And As Directed. , M And L Sand Cushioning Dry In Trenches For Protection Of Ug Cables Etc. - M&L Sand Cushioning (Dry) In Trenches For Protection Of Ug Cables (Below, Above And Around The Ug Cable Laid In Trenches) Of 230Mm Spread Thickness And Consolidated (Punned) Upto 180Mm Thickness, Complete All As Specified And As Directed. (Note . For The Purpose Of Payment, Punned Thick-Ness Of Sand Cushioning Only Shall Be Measured And Paid ) , Supply And Laying Well Burnt Bricks Locally Available Best Quality Etc. - Supply And Laying Well Burnt Bricks , Locally Available Best Quality (Sub Class B Bricks) Laid In Trenches Perpandicular To U/G Cable For Cable Protection Complete All As Specified. , Laying Only In Trenches Or Passing Through Pipe Xlpe Insulated Heavy Duty Galvanised Steel Strip Etc. - Laying Only In Trenches Or Passing Through Pipe, Xlpe Insulated, Heavy Duty, Galvanised Steel Strip Or Wire Armoured Electric Lt Cable With Stranded Aluminium Conductor For 1100 Volts Grade Cross Sectional Area 50 Sqmm 3.5 Core.Note . Cable Will Be Issued Under Sch B Free For Laying Only , Laying Only In Trenches Or Passing Through Pipe Xlpe Insulated Heavy Duty Etc. - Laying Only In Trenches Or Passing Through Pipe, Xlpe Insulated, Heavy Duty, Galvanised Steel Strip Or Wire Armoured Electric Lt Cable With Stranded Aluminium Conductor For 1100 Volts Grade Cross Sectional Area 10 Sqmm 4 Core.Note . Cable Will Be Issued Under Sch B Free For Laying Only , S And F 40 Mm High Density Polyethylene Pipe Hdpe Of Pressure Rating 6 Kgf Etc. - S & F 40 Mm High Density Polyethylene Pipe (Hdpe) Of Pressure Rating 6 Kgf/Cm2 Fixed Complete To Walls, Ceilings Or In Floors Etc. Complete All As Specified And Directed . , S And F Galvanised Iron Pipe 40Mm Bore Dia Light Grade For Protection Of Ug Cable Etc. - S&F Galvanised Iron Pipe 40Mm Bore (Dia) Light Grade For Protection Of Ug Cable, Laid In Floors/ Road Crossing, Fixing To Pole With Mild Steel Cl S, Nuts, Bolts, Etc., Complete All As Specified And As Directed. , Labour Only For Horizontal Boring For Passing Protection Pipe Up To 80Mm Bore Dia Etc. - Labour Only For Horizontal Boring For Passing Protection Pipe Up To 80Mm Bore (Dia), Under Road /Foot Path, Not Exc. 10.00 Mtr In A Single Length, Complete All As Specified And As Directed. Note . Pipe To Be Measured Separately. , M And L For Pcc 1.2.4 Type B1 Using 20 Mm Graded Aggregate Etc. - M&L For Pcc (1.2.4) Type B1 (Using 20 Mm Graded Aggregate) As In Coping For Pole Including Form Work And Finishing The Surfaces Even And Smooth,Dismantling Etc Complete All As Specified And As Directed. , M And L For Pcc 1.3.6 Type C2 Using 40 Mm Graded Aggregate Etc. - M&L For Pcc 1.3.6 Type C2 (Using 40 Mm Graded Aggregate) As In Foundation For Pole Etc Complete All As Specified And As Directed. , Supply And Fixing Crca Sheet Steel Duly Phosphatized And Powder Coated With 7 Tank Etc. - Supply And Fixing Crca Sheet Steel Duly Phosphatized And Powder Coated With 7 Tank Process,Wall/Pole Mounted/Floor Mounted,Degree Of Protection Ip 54,Pre-Wired,Liberal Terminal Space,Louvers Provided On Both Sides For Proper Heat Heat Dissipation,Manufactured By An Iso 9001 Certified Company,Door Locking By Panel Lock And Provided For Pad Locking Available,With Auto/Manual Selection Switch,Astronomical Programmable Time Switch( Operating Voltage 220-240 Volt Ac),Three Phase,Mcb Tpn 63 (Coil Voltage 240 Volt Ac) ,Power Contactor 65 ,Tp,Astronomical Timer,Terminal Blocks,Maximun Load 12Kw, Complete All As Specified And As Directed. , Fixing Only Led Street Light Fitting 100 Watt 230 V Ac Outdoor Type Etc. - Fixing Only Led Street Light Fitting 100 Watt 230 V Ac Outdoor Type Including Necessary Connection Complete All As Specified.Note . Street Light Will Be Issued Under Sch B Free For Fixing Only. , Fixing Only Led Flood Light Fitting 200 Watt 230 V Ac Outdoor Type Etc. - Fixing Only Led Flood Light Fitting 200 Watt 230 V Ac Outdoor Type Complete All As Specified And Directed.Note . Flood Light Will Be Issued Under Sch B Free For Fixing Only.
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Taking down of light fittings of any type size and model etc. | Taking down of light fittings of any type size and model complete all as specified and directed. |
| 2 | Taking down of brackets of any type size and model etc. | Taking down of brackets of any type size and model complete all as specified and directed. |
| 3 | Dismantling steel poles struts of any size and removing off the site etc. | Dismantling steel poles/struts of any size and removing off the site complete all as specified and directed. |
| 4 | Taking down out unserviceable UG Cables of any Cross Sectional Area etc. | Taking down/out unserviceable UG Cables of any Cross Sectional Area and Connections including Bricks, GI Pipes, etc. of any descriptions, laid in Trenches and/or fixing with Walls/Poles including Segregating of Serviceable Materials viz Bricks, Cables, GI Pipes, etc. and keep in Safe custody for re-use, complete all as specified and as directed. |
| 5 | Material and labour for steel tubular poles complete with cast iron etc. | Material and labour for steel tubular poles complete with cast iron base palate, final taper plug bolts, nuts & screws as specified type 410 SP-22 8.50 meter long including painting all external exposed steel surfaces with two coats of aliminium paint |
| 6 | S and F Cable Junction Box 155X210X92 mm in size made out of thermoplastic etc. | S&F Cable Junction Box 155X210X92 mm in size, made out of thermoplastic, having IP 66 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M-32 -02 No & M-25 -01 No) fixed on poles with Aluminium clamps of size 25x3mm, nuts, bolts, washers etc. including taking out of old unserviceable cable junction box complete all as specified and as directed. |
| 7 | Supply and passing through steel tubler pole service connection etc. | Supply and passing through steel tubler pole/service connection, 1100 volts grade multicore,FR, round insulated copper conductor and sheathed flexible cable,multistranded, three core of nominal cross sectonal area 1.5 Sq mm,for connection of security light from junction box through pole /conduit with all terminals complete all as specified and as directed. |
| 8 | S and F singlearmbracketmadeof40mmdia10mtrlong for security light | S and F singlearmbracketmadeof40mmdia10mtrlong for security light with mounting MS clamp of flat iron size 25X5 mm of suitable length 02 pairs including nut bolts etc of suitable size and painting to MS clamp with two coats of aluminium paints over a coat of red oxide metal primer all as specified and directed by Engr In charge |
| 9 | M and L for earthing complete with galvanised steel earth plate electrode etc. | M&L for earthing complete with galvanised steel earth plate electrode size 600 x 600 x 6 mm thick, burried directly in ground, (Earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below ground level connected to galvanised iron strip 32 x 6 mm as earthin lead wire by means of bolts, nuts, |
| 10 | Excavating in trenches n.exc 1.5 m wide and n.exc 1.5 m depth etc. | Excavating in trenches , n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts, wells, cesspits ,manhole pier hole, laying of cables, pipes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any kind of soil |
| 11 | Returning Filling in including Spreading Levelling Watering and Well Ramming etc. | Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 250mm in Soft/Loose Soil, complete all as specified and as directed. |
| 12 | Removing excavated Materials Soils not exc. 50.00 mtr etc. | Removing excavated Materials (Soils) not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil, complete all as specified and as directed. |
| 13 | M and L Sand Cushioning dry in trenches for protection of UG Cables etc. | M&L Sand Cushioning (dry) in trenches for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. (NOTE . For the purpose of Payment, Punned thick-ness of Sand Cushioning only shall be Measured and Paid ) |
| 14 | Supply and laying well burnt Bricks locally available best quality etc. | Supply and laying well burnt Bricks , locally available best quality (sub class B bricks) laid in trenches perpandicular to U/G cable for cable protection complete all as specified. |
| 15 | Laying only in trenches or passing through pipe XLPE insulated heavy duty galvanised steel strip etc. | Laying only in trenches or passing through pipe, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 50 sqmm 3.5 core.Note . Cable will be issued under Sch B free for laying only |
| 16 | Laying only in trenches or passing through pipe XLPE insulated heavy duty etc. | Laying only in trenches or passing through pipe, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 10 sqmm 4 core.Note . Cable will be issued under Sch B free for laying only |
| 17 | S and F 40 mm High density polyethylene pipe HDPE of pressure rating 6 kgf etc. | S & F 40 mm High density polyethylene pipe (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc. complete all as specified and directed . |
| 18 | S and F Galvanised Iron Pipe 40mm Bore dia Light Grade for protection of UG Cable etc. | S&F Galvanised Iron Pipe 40mm Bore (dia) Light Grade for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. |
| 19 | Labour only for Horizontal Boring for Passing Protection Pipe up to 80mm Bore dia etc. | Labour only for Horizontal Boring for Passing Protection Pipe up to 80mm Bore (dia), under Road /Foot Path, not exc. 10.00 mtr in a Single Length, complete all as specified and as directed. Note . Pipe to be measured separately. |
| 20 | M and L for PCC 1.2.4 type B1 using 20 mm graded aggregate etc. | M&L for PCC (1.2.4) type B1 (using 20 mm graded aggregate) as in coping for pole including form work and finishing the surfaces even and smooth,dismantling etc complete all as specified and as directed. |
| 21 | M and L for PCC 1.3.6 type C2 using 40 mm graded aggregate etc. | M&L for PCC 1.3.6 type C2 (using 40 mm graded aggregate) as in foundation for pole etc complete all as specified and as directed. |
| 22 | Supply and fixing CRCA sheet steel duly phosphatized and powder coated with 7 tank etc. | Supply and fixing CRCA sheet steel duly phosphatized and powder coated with 7 tank process,wall/pole mounted/floor mounted,degree of protection IP 54,pre-wired,liberal terminal space,louvers provided on both sides for proper heat heat dissipation,manufactured by an ISO 9001 certified company,door locking by panel lock and provided for pad locking available,with auto/manual selection switch,astronomical programmable time switch( Operating voltage 220-240 Volt AC),three phase,MCB TPN 63 Amp(coil voltage 240 Volt AC) ,Power Contactor 65 Amp,TP,Astronomical timer,terminal blocks,maximun load 12KW, complete all as specified and as directed. |
| 23 | Fixing only LED street light fitting 100 Watt 230 V AC outdoor type etc. | Fixing only LED street light fitting 100 Watt 230 V AC outdoor type including necessary connection complete all as specified.Note . Street light will be issued under Sch B free for fixing only. |
| 24 | Fixing only LED Flood light fitting 200 Watt 230 V AC outdoor type etc. | Fixing only LED Flood light fitting 200 Watt 230 V AC outdoor type complete all as specified and directed.Note . Flood light will be issued under Sch B free for fixing only. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender