Bids Are invited for Supply Laying And Testing Cable Xlpe Insulated Screened Pvc Bedded Galvanized Steel Strip Etc. - Supply, Installation, Testing Of Current Transformer 33Kv, Single Phase, Outdoor Oil Filled , Ratio 150 75/5 5A , Two Core, One Mete
Tender Overview
Project Description
Bids Are invited for Supply Laying And Testing Cable Xlpe Insulated Screened Pvc Bedded Galvanized Steel Strip Etc. - Supply, Installation, Testing Of Current Transformer 33Kv, Single Phase, Outdoor Oil Filled , Ratio 150 75/5 5A , Two Core, One Metering (Burden 15Va, Accuracy Class 0.5) And One Protection Core (Burden 30Va, Accuracy Class 5P20) Insulation Level 36 Kv / 70 Kv As Per Is 2705 To Suit Vcb Make Complete Incl Taking Out Old Ct All As Per S Le And Directed. , Excavation In Trenches Not Exceeding 1.5 M Width And Not Exc 1.5M In Depth Getting Etc. - Supply, Installation, Testing Of 33 Kv Single Phase Out Door Oil Cooled Pt Of Ratio 33 Kv/ Rt 3 / 110 V/Rt 3 Accuracy Class 1.0 . Burden 100Va. Insulation Class 70/170 Kv , Voltage Fector 1.2 Cont And 1.5 For 30 Sec , Confirming To Is 3156 Complete (As Per S Le) Incl Taking Down Old Unserviceable Pt All As Specified And Directed. , Excavation In Trenches Not Exceeding 1.5 M Width And Exc 1.5M In Depth Getting Out Etc. - Supply & Fixing Of 33 Kv Disc Type Suspension Insulator, Porcelain/Polymer Type, 70 Kn Mechanical Strength, Complete With Cap And Pin, Ball & Socket Type Coupling, Suitable For 33 Kv Overhead Line, Conforming To Is 731, Including All Fittings And Accessories Complete All As Specified And Directed. , Returning Filling In Including Spreading Levelling Watering And Well Ramming In Layers Etc. - Supply & Fixing Of 33 Kv Post Type Insulator, Porcelain/Polymer, Brown Glazed, Suitable For 33 Kv Overhead Line, Complete With Gi Pin, Lead Thimble, And All Accessories, Conforming To Is 731 / Is 2544 Complete All As Specified And Directed. , Removal Of Surplus Soil To A Distance Not Exceeding 50 M And Depositing Where Etc. - Preparation Of Detailed Layout Drawing In Autocad And Supply, Fabrication, Uv Printing/Engraving And Fixing Of 33 Kv Main Receiving Station Layout, Powerhouse No 2 Layout And Powerhouse No 1 Layout On Acp Board, Comprising Site Verification, Preparation/Finalization Of Single Line Diagram (Sld) And Equipment Layout In Autocad, Submission For Approval, High Resolution Uv Printing Or Cnc Engraving On Minimum 3 Mm Thick Aluminium Composite Panel (Acp), Protective Coating, Aluminium Framing, And Wall Mounting Complete In All Respects. , Supply And Lay Of Pcc Cable Cover Class Hv Type 1 Flat Size 300Mmx180mmx40mm Etc. - M & L For Filling And Spreading Aggregate/Stone Using 40 Mm Grade Trap Stone Aggregate Around 4 Pole , 2 Pole Structure And Transformer Etc. , Supply And Lay For Dry Clean Dirtless River Sand Filling For Cable Protection With A Layer Of 8Cm Etc. - M&L For Surface Excavation N. Exc 30 Cm Deep And Averaging 15 Cm Deep And Getting Out Complete All As Specified And As Directed. , M And L For Double Wall Corrugated Dwc High Density Polyethylene Pipes Hdpe Of 90Mm Dia Etc. - M&L 150 Mm Thick Soiling (Or Sub Base) With Broken Boulders Or Quarried Stone, Interstices Filled, Suface Formed And Rolled And Consolidated To Required Gradient And Camber All As Specified And Directed. , M And L For Fixing Gi Tubing 80Mm Dia Light Grade Use For The Protection Of Cable Etc. - M&L For Moorum/Red Bajri Filling In Floors Or Pavings, Laid In Layers N Exc. 15 Cm Thick, Spread, Levelled And Rammed Including Watering Complete All As Specified And Directed. , M And L For Manual Boring Under Road Crossing And Laying Pipe Across The Road Etc. - M&L For Pcc 1 4 8 Type D 2 (40Mm Graded Aggregate) In Foundations, Filling And Mass Concrete. , Sandf Pcc Cable Route Marker Of Size 900X300x70mm Embossed With Ht Ug Etc. - M&L For Pcc 1 2 4 Type B1 (Using 20Mm Grade Aggregate) As In Coping For Pole Inclduing Form Work And Finishing The Surfaces Even And Smooth Etc Complete All As Specified And Directed. , Material And Labour For Steel Tubular Poles Complete With Cast Iron Base Palate Final Taper Plug Bolts Nuts Etc. - Supply And Fix Led Tube Light Fitting Surface And Wall Mounted Batten With 20 Watts Led Including Removal Of Old One Complete All As Specified And Directed. , M And L For Switch Air Break Gang Operated Triple Pole Out Door Type Unit On Ht 11 Kv Etc. - M And L For Earthing Complete With Galvanised Steel Earth Plate Electrode 60X60cm 6Mm Thick Buried Directly In Ground Earth Pit Not Less Than 225 Metres Deep Below Ground Level With Top Edge Of The Plate Not Less Than 15 Metres Below Normal Ground Level Connected To Galvanised Iron Strip 25X4mm By Means Of Bolts Nuts Check Nuts And Washers Of Galvanised Iron Or Steel All As Shown In Electrical Plate No 3 Connected To Earthing Test Point All As Specified Or Indicated Including Testing On Completion , M And L For 11 Kv 200 S Outdoor Type Horn Gap Fuse Set Conforming To Is 9385 Part I And Ii Etc. - Excavation In Trenches Not Exceeding 1.5 M Width And Not Exc 1.5M In Depth Getting Out In Soft/Loose Soil All As Specified And As Directed. , M And L For Cross Arms Bracing Supports Cl S And Back Plates Fabricated From Structural Etc. - Excavation In Trenches Not Exceeding 1.5 M Width And Exc 1.5M In Depth Getting Out In Soft/Loose Soil All As Specified And As Directed. , M And L For Pin Type Porcelain Vitreous Brown Insulator Of Size 150Mm Height 150Mm Etc. - Returning Filling In Including Spreading Levelling Watering And Well Ramming In Layers Not Exceeding 25 Cm In Thick Using Excavated Soft/Loose Soil All As Specified And As Directed. , M And L For Lightning Arrester Surge Protector 11 Kv Grade Heavy Duty Single Pole Etc. - Removal Of Surplus Soil To A Distance Not Exceeding 50 M And Depositing Where Directed By Engr In Charge. , S And F Danger Notice Plate Of 1.6Mm Thick Mild Steel Sheet Vitreous Enamelled White Etc. - M&L For Fixing Gi Tubing 15Mm Dia Light Grade Use For The Protection Of Earthing Lead. , M And L For Cement Concrete In Foundations Filling And Mass Concrete Type D2 Etc. - M&L For Fixing Gi Tubing 20Mm Dia Light Grade Use For Watering To Earthing , M And L For Pcc 1 3 6 Type C2 Using 40Mm Grade Aggregate As In Foundation For Pole Etc. - M&L For Funnel, Wire Mesh, Lugs, Nut, Bolts Etc , M And L For Pcc 1 2 4 Type B1 Using 20Mm Grade Aggregate As In Coping For Pole Etc. - M&L For Ms Angle Frame And Sheet Cover , M And L For Earthing Complete With Galvanised Steel Earth Plate Electrode 60X60cm 6Mm Thick Etc - M&L For Pcc 1 2 4 Type B1 (Using 20Mm Grade Aggregate) For Earth Pit Chamber Inclduing Form Work And Finishing The Surfaces Even And Smooth Etc Complete , M And L For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Etc. - M And L For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit/Pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Etc. As Required 32X6 Mm Galvanised Iron Strip Complete , M And L For Disc Type Porcelain Polymer Insulator Vitreous 145 Mm Height And 255 Mm Etc. - M And L For Disc Type Porcelain/Polymer Insulator Vitreous 145 Mm Height And 255 Mm Diameter Ball And Socket Type Suitable For 11 000 Volts Grade Complete With One Galvanized Mild Steel Spindle Two Galvanized Iron Washers And One Galvanized Iron Nut Complete In All Respects As Specified And As Directed.
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Supply laying and testing cable XLPE insulated screened PVC bedded galvanized steel strip etc. | Supply, installation, testing of Current Transformer 33KV, single phase, Outdoor Oil filled , ratio 150 75/5 5A , Two core, one metering (Burden 15VA, Accuracy class 0.5) and one protection core (Burden 30VA, Accuracy class 5P20) insulation level 36 KV / 70 KV as per IS 2705 to suit VCB make complete incl taking out old CT all as per sample and directed. |
| 2 | Excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth getting etc. | Supply, installation, testing of 33 KV single phase out door oil cooled PT of ratio 33 KV/ rt 3 / 110 V/rt 3 accuracy class 1.0 . Burden 100VA. Insulation class 70/170 KV , voltage fector 1.2 cont and 1.5 for 30 sec , confirming to IS 3156 complete (As per sample) incl taking down old unserviceable PT all as specified and directed. |
| 3 | Excavation in trenches not exceeding 1.5 m width and exc 1.5m in depth getting out etc. | Supply & fixing of 33 kV disc type suspension insulator, porcelain/polymer type, 70 kN mechanical strength, complete with cap and pin, ball & socket type coupling, suitable for 33 kV overhead line, conforming to IS 731, including all fittings and accessories complete all as specified and directed. |
| 4 | Returning filling in including spreading levelling watering and well ramming in layers etc. | Supply & fixing of 33 kV post type insulator, porcelain/polymer, brown glazed, suitable for 33 kV overhead line, complete with GI pin, lead thimble, and all accessories, conforming to IS 731 / IS 2544 complete all as specified and directed. |
| 5 | Removal of surplus soil to a distance not exceeding 50 m and depositing where etc. | Preparation of detailed layout drawing in AutoCAD and supply, fabrication, UV printing/engraving and fixing of 33 kV Main Receiving Station Layout, Powerhouse No 2 Layout and Powerhouse No 1 layout on ACP board, comprising site verification, preparation/finalization of Single Line Diagram (SLD) and equipment layout in AutoCAD, submission for approval, high resolution UV printing or CNC engraving on minimum 3 mm thick Aluminium Composite Panel (ACP), protective coating, aluminium framing, and wall mounting complete in all respects. |
| 6 | Supply and lay of PCC cable cover class HV type 1 flat size 300mmx180mmx40mm etc. | M & L for filling and spreading aggregate/stone using 40 mm grade trap stone aggregate around 4 pole , 2 pole structure and transformer etc. |
| 7 | Supply and lay for dry clean dirtless river sand filling for cable protection with a layer of 8cm etc. | M&L for surface excavation n. exc 30 cm deep and averaging 15 cm deep and getting out complete all as specified and as directed. |
| 8 | M and L for Double Wall Corrugated DWC High density polyethylene pipes HDPE of 90mm dia etc. | M&L 150 mm thick soiling (or sub base) with broken boulders or quarried stone, interstices filled, suface formed and rolled and consolidated to required gradient and camber all as specified and directed. |
| 9 | M and L for fixing GI tubing 80mm dia light grade use for the protection of cable etc. | M&L for moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed. |
| 10 | M and L for manual boring under road crossing and laying pipe across the road etc. | M&L for PCC 1 4 8 type D 2 (40mm graded aggregate) in foundations, filling and mass concrete. |
| 11 | SandF PCC cable route marker of size 900x300x70mm embossed with HT UG etc. | M&L for PCC 1 2 4 type B1 (using 20mm grade aggregate) as in coping for pole inclduing form work and finishing the surfaces even and smooth etc complete all as specified and directed. |
| 12 | Material and labour for steel tubular poles complete with cast iron base palate final taper plug bolts nuts etc. | Supply and fix LED tube light fitting surface and wall mounted batten with 20 watts LED including removal of old one complete all as specified and directed. |
| 13 | M and L for switch air break gang operated triple pole out door type unit on HT 11 KV etc. | M and L for Earthing complete with galvanised steel earth plate electrode 60X60cm 6mm thick buried directly in ground earth pit not less than 225 metres deep below ground level with top edge of the plate not less than 15 metres below normal ground level connected to galvanised iron strip 25x4mm by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion |
| 14 | M and L for 11 kV 200 Amps outdoor type Horn Gap Fuse set conforming to IS 9385 Part I and II etc. | Excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth getting out in soft/loose soil all as specified and as directed. |
| 15 | M and L for cross arms bracing supports clamps and back plates fabricated from structural etc. | Excavation in trenches not exceeding 1.5 m width and exc 1.5m in depth getting out in soft/loose soil all as specified and as directed. |
| 16 | M and L for pin type porcelain vitreous brown insulator of size 150mm height 150mm etc. | Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated soft/loose soil all as specified and as directed. |
| 17 | M and L for lightning arrester surge protector 11 KV grade heavy duty single pole etc. | Removal of surplus soil to a distance not exceeding 50 m and depositing where directed by Engr in charge. |
| 18 | S and F Danger notice plate of 1.6mm thick mild steel sheet vitreous enamelled white etc. | M&L for fixing GI tubing 15mm dia light grade use for the protection of earthing lead. |
| 19 | M and L for Cement concrete in foundations filling and mass concrete type D2 etc. | M&L for fixing GI tubing 20mm dia light grade use for watering to earthing |
| 20 | M and L for PCC 1 3 6 type C2 using 40mm grade aggregate as in foundation for pole etc. | M&L for funnel, wire mesh, lugs, nut, bolts etc |
| 21 | M and L for PCC 1 2 4 type B1 using 20mm grade aggregate as in coping for pole etc. | M&L for MS angle frame and sheet cover |
| 22 | M and L for Earthing complete with galvanised steel earth plate electrode 60X60cm 6mm thick etc | M&L for PCC 1 2 4 type B1 (using 20mm grade aggregate) for earth pit chamber inclduing form work and finishing the surfaces even and smooth etc complete |
| 23 | M and L for Earth continuity conductor or main earthing lead fixed to wall on batten etc. | M and L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6 mm galvanised iron strip complete |
| 24 | M and L for disc type porcelain polymer insulator vitreous 145 mm height and 255 mm etc. | M and L for disc type porcelain/polymer insulator vitreous 145 mm height and 255 mm diameter ball and socket type suitable for 11 000 volts grade complete with one galvanized mild steel spindle two galvanized iron washers and one galvanized iron nut complete in all respects as specified and as directed. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender