Environment and Forests Government Departments Closing in 5 days TDR #56656928

Tender For Establishing Eco -Canteen / Cafeteria In Thalayanai Eco Tourism Site, Thalayani North Beat, Thalayanai Section, Puliyankudi Range Of Tenkasi Divison Under Sdap For The Year 2025-26

Issued by Government Departments · Tenkasi, Tamil Nadu
Tender Value
6 Lakhs
Estimated cost
Bid Submission
01 Aug 2026
5 days left
EMD
6000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tenkasi → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Establishing Eco -Canteen / Cafeteria In Thalayanai Eco Tourism Site, Thalayani North Beat, Thalayanai Section, Puliyankudi Range Of Tenkasi Divison Under Sdap For The Year 2025-26

BOQ

Name of Work:- Establishing eco -canteen / cafeteria in Thalayanai Eco Tourism Site, Thalayani North Beat, Thalayanai Section, Puliyankudi Range of Tenkasi Divison under SDAP for the year 2025-26
Sl. No. Item Description
1Earth work excavation for foundation (for narrow excavation) in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification.
2Cement Concrete 1:5:10 (One Cement, Five M.Sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification
3Supplying and filling in foundation, basement, etc with filling M.Sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
4Supplying and filling in foundation, basement, etc with conveyed Well gravel in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
5Flooring Concrete 1:5:10 (One cement, Four M.Sand and Eight hard broken stone) using 40 mm gauge hard broken jelly for flooring including laying, consolidating, finishing, rendering the top surface rough to receive the floor, curing, etc. complete complying with standard specification. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers.
6Brick work in Cement Mortar 1:6 (One Cement, Six crushed stone sand) using best quality Country Brick of size 8 3/4” x 4 1/4” x 2 3/4” including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification .
7For foundation & basement
8For Super Structure in G.F
9Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)
10Cement Concrete 1:2:4 (One Cement, Two crushed stone sand and Four hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly for all RCC items of works excluding cost of reinforcement grill and fabricating charges, centering and shuttering but including Super Plasticiser, laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary and bearing surfaces of walls, beams etc. shall be finished smooth with Cement Mortar 1:3 (One Cement and Three Sand) and kraft paper laid over it without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers - manual mix
11For foundation & basement
12Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire) Foundation & basement
13Supply and fabrication of Mild steel square section truss and purlins for Roofing with colour galvalume sheet of 0.47mm thick (as per lowest quatation)
14Supplying , fixing and roofing with Stone Coated Metal Roofing Sheet prefabricated roofing sheet with all necessary accessories such as J/V bolt and nuts of suitable length with suitable bitumen washers complete complying with standard specification and as directed by the department
15Paving the floor with best quality Attangudi Tiles Size 12 x 12 x 3/4 and variety conforming IS 15622 with water absorbtion less than 0.08% of approved colour and shade laid over cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer in all floors and the top pointed with Water Resistant Tile Epoxy Grout etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Forest Officer before use on works)
16Plastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
17Supplying and painting the walls with two coats of wall putty as instructed by thedepartmental officers including preparation of surface curing, etc., complete in all floors complying with standard specifications and as directed by the departmental officers. (The wall putty shall be got approved by the Executive Engineer before use of work).
18Painting Two coats with ready mixed Interior Plastic Emulsion Paint approved quality and colour including a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. - 10 sq.m
19Painting two coats with ready mixed Exterior Emulsion Paint approved quality and colour including a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. - 10 sq.m
20Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Forest Officer before use on work.
21Supplying and fixing inposition C.R.C.A.pressed steel doors frame as per I.S.4351/1976 of size 105x60mm with 35x12mm rebate on all sides with 1.25mm thick (18 gauge) sheet frames special profile extruded section including bottom tie hold faste at appropriate places and provision to fix aldrops tower bolts hinges and lock strike plate etc.The door frame inner shall be packed with CC 1:2:4 using 12mm guage HBG stone jelly including fixing the door frames inposition and dimantling the masonry and concrete wherever necessary and redoing the same original condition after fixing including scaffolding charges and labour charges and door frame will be given one coat of Red Oxide primer etc. Complete complying with standard specification The rate shall inclusive of all materials, labour, transportation, loading, unloading, handling, charges etc SOR M-0303
22Providing of 35mm thick factory made pre-laminated ABS (Acrolynitrile Butadiene Styrene) Door Shutter moulded in different designs, consisting of all round frame made out of water proof solid foam PVC bar of size 20 x 32mm, reinforced by 32 x 32mm - 2 Nos., for vertical made out of LVL (Laminated Veneer Lumber), core material of 32mm thick high density craft paper honey comb board, sandwiched on both sides with pre-laminated ABS sheet thickness of 1.5mm. PVC edge banding of size 0.45mm on the vertical sides. Hardware made out of steel coated butterfly hinges - 3 Nos., for each shutter and ISI make SS round lock complete for finished item of work, complete complying with the standard specification. The door shutter and frame should be got approved from the Executive Engineer before use on work (SOR No: 263)
23Manufacturing supplying and fixing in position of teracotta jally 20x20x0.75mm thick approved quality and design in cement slurry including cost of materials labour curing lifting fixing in position etc, complete complying with standard specification and as directed by the departmental officers in all floors.
24Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Departmetal officers before use on works.)
25Dadooing walls with following best approved quality, white / colour glazed tiles of following sizes set in Cement Mortar 1:2 (One Cement and Two sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers. Dadooing with printed design colour glazed tiles of size 300 x 450 x 8mm
26External Water Supply Arrangements using UPVC pipes and UPVC specialsSupplying, laying and jointing UPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., Above ground level.
27(a) 20mm UPVC pipe
28(b) 25mm UPVC pipe
29Supplying UPVC Specials (with working pressure 10 kg. / sq.cm.) in water supply arrangements (both in internal and external water supply arrangements
3025mm dia Tee
3125mm dia Elbow
3225mm dia Union
3320mm dia Tee
3420mm dia Elbow
3520mm dia Union
3625x20mm Reducer tee
3720x15mm Elbow
38Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Forest Officerer before use on work.
3920mm gate valve
4025mm gate valve
41Supply and Installation of Brass Chromium Plated Screw Down Tap 15 / 12mm dia (Heavy Type)
42Supplying, laying and jointing UPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., Below ground level.
4325mm UPVC pipe
44Supplying UPVC Specials (with working pressure 10 kg. / sq.cm.) in water supply arrangements (both in internal and external water supply arrangements Below Ground level
4525mm dia Coupler
4625mm dia Tee
4725mm dia Elbow
4825mm dia Union
49Supplying, fabricating, erecting and fixing Using perforated sheets (10mm thick)board false ceiling upto a ceiling height of 4.5m from floor level PWD SOR No. m-0619
50Supply and fixing of single box type 4'40 W flu fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed Copper leads from terminals to the fitting.S.D 89
51Supply and fixing of 1200 mm (48\\") AC ceiling fan complete with stepped electronic 300W regulator with 1 1 meter down rod on the existing clamp. S.D 110
52Wiring with 2 x 1.5 sq.mm.(22/0.3) PVC insulated SC unsheathed Cu. Contractor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceilig with PVC accessories, in flush with wall, with 150mm x 100mm x 113mm TW switch box with 3mm thick Hylem sheet cover for 5A 3 pin non inter locking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC plug point.(S.D 36) of PWD Electrical detailed data - P.V.C Plug Point )
53Wiring with 2 x 1.5 sq.mm.(22/0.3) PVC insulated SC unsheathed Cu. Contractor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceilig with PVC accessories, in flush with wall with 3mm thick Hylem sheet cover with TW switch box and 5A F.T switch and making good of the oncealed portion with suitable colour for PVC concealed light / Fan point (For electronic regulator ) (5points per coil (S.D 24) of PWD Electrical detailed data - Light Points & Fan Points 2024-2025
54Supply and fixing of fancy glass shade and 15 W LED Bulb Electriacal SD 80
55Supplying and fixing in position best quality approved make white glazed earthernwere sink of size of 600 x 450 x 200mm including cost of 32mm dia CP waste coupling, 32mm dia PVC waste pipe with rubber plug and chain, 15mm dia brass nipple including fixing the sink in position and testing for leakages etc., complete complying with standard specifications excluding CI brackets. [The sink and specials should be got approved by the Forest Officerer before use on works]
56Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia \\"B\\" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Forest Officerer before use on works).
57Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia \\"B\\" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Forest Officerer before use on works).
58Brick partition walls of 10.80cm thickness using best quality Country Brick of size 8-3/4\\" x 4-1/4\\" x 2-3/4\\" in Cement Mortar 1:3 (One Cement and Three CS Sand) using hoop iron reinforcement if found necessary including Cost of Mortar Plasticizer, curing etc.
59Supply and installation of a stone plaque 21/2 x 21/2 feet depicting the details of name of scheme (SADP), name of the work, estimate cost, year of sanction, name of the Implementing Agency should be erected in a prominent and permanent location. (SADP Name should be highlighted in Golden Letters) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56656928
AUTHORITY Government Departments
TENDER VALUE 6 Lakhs
LAST DATE 01-08-2026
Authority
Authority Name Forest Department
Work Description Tender for Establishing Eco -Canteen / Cafeteria In Thalayanai Eco Tourism Site, Thalayani North Beat, Thalayanai Section, Puliyankudi Range Of Tenkasi Divison Under Sdap For The Year 2025-26
Basic Detail
Tender No TEN-FD-14/2026-27
Bidding Type Tender
Location
City Tenkasi
State Tamil Nadu
Key Dates
Publish Date 25 Jul 2026
Submission Date 01 Aug 2026
Open Date 01 Aug 2026
Finance
Tender Value 6 Lakhs
Tender Fee Ref. Documents
EMD 6000
Exemption Not Available
Document List
1596c387-8250-4bfe-a226-54e034415418.html
BOQ_827684.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 25, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Aug 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

1596c387-8250-4bfe-a226-54e034415418.html

xls

BOQ_827684.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders