Tender For Necessary Repairing And Renovation Of 3Rd Floor Of Hrbc Bhawan To Accomadate Office Of The Enquery Commission At Munshi Premchand Sarani,Kolkata-700021 During The Year 2026-27-----Sitcof Intelligent Fire Detection System.
Tender Overview
Project Description
Tender for Necessary Repairing And Renovation Of 3Rd Floor Of Hrbc Bhawan To Accomadate Office Of The Enquery Commission At Munshi Premchand Sarani,Kolkata-700021 During The Year 2026-27-----Sitcof Intelligent Fire Detection System.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 27-Jul-2026 | CORRECTION OF BOQ | Other | 07-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | FIRE CONTROL PANEL |
| 2 | DETECTOR, INDICATOR, HOOTER & CALL POINT |
| 3 | Supply,Installation,Testing & Commisioning of Micropresssor controlled Addressable Multisensor detector(VDS/UL/LPCB/ FM approved ) withinbuilt optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA(Note : Detectors without built-in fault isolator is also acceptable withone independent short circuit fault isolator after every four (04) detector isto be provided without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 egreeopticalviewwithsingle/multipleLEDthatblinkson actuation of detector. Reverse polarity or faulty zone wiring shall not damagethedetectors.DegreeofprotectionasperOEMStandard. (Approved Make: Esser/Cerberus Pro/Bosch/Johnson Controls/Notifer / Edward /Secutron Securiton/Apollo / Morley /System sensor/ GST/Eaton/security) |
| 4 | Supply, Installation, Testing & Commisioning of addressable Manual Call Point (VDS/UL/LPCB/FM approved) withinbuilt short circuit fault isolatoras per NFPA (Note : MCP without built-in fault isolator is also acceptable withone independent short circuit fault isolatoris to beprovided withoutextra cost).Degree ofprotection as per OEM Standard.(Approved Make: Esser/Cerberus Pro/Bosch/Johnson Controls/Notifer / Edward /Secutron Securiton/Apollo / Morley /System sensor/Eaton/GST) |
| 5 | Supply, Installation, Testing& Commissioning of Addressable Loop Powered /panel poweredHooter(sound output of minimum 90 db )cum strobe (strength of light 10 cd) complete with inbuilt short circuit fault isolator as per NFPA (Note:Hooterwithoutbuilt-infaultisolator is also acceptable with one independent short circuit fault isolatoris to be provided without extracost).(VDS/UL/LPCB/FMapproved)approved.DegreeofprotectionasperOEMStandard. (Approved Make: Esser/Cerberus Pro/Bosch/Johnson Controls/Notifer / Edward /Secutron Securiton/Apollo / Morley /System sensor/Eaton/GST) |
| 6 | Supply, Installation,Testing& Commisioning of Micropresssor controlle dAddressable Heat detector (VDS / UL / LPCB / FM approved) with combination of fixed type& Rate of Rise of Temperature feature. Detector shall have minimum triggering temperature programmable from 58 deg. C to 68 deg. C., having high level of immunity to electromagnetici fluancesandshowalarmsignal limit temperature is reached. Detector shall have inbuilt short circuit fault isolator as per NFPA(Note : Detectors without built-in fault isolator is also acceptable withone independent short circuit fault isolator after every four (04) detector in the loopis to be provided without extra cost) the detectors should have built in response indicator with LED indicator.Degree of protection as per OEM Standard. (Approved Make: Esser/Cerberus Pro/Bosch/Johnson Controls/Notifer / Edward /Secutron Securiton/Apollo / Morley /System Sensor/GST) |
| 7 | INTERCONNECTION |
| 8 | Supplying & laying of 2x1.5 sqmm FRLS shielded copper Conductor ( Make RR Kabel/Polycab) stranded cables in red/black color and generally confirming to IS-694-2010 and meet the signal cabling requirements (Make-Havells/Finolex/Polycab/Gloster/KEI as approved by E.I.C) throw 19mm dia PVC FR' type |
| 9 | TERMS & CONDITIONS |
| 10 | The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. |
| 11 | Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill. |
| 12 | If any refurbished material is supplied and installed, penal action will be taken as per existing rules. |
| 13 | Add. G.S.T.@ 18% on total of item |
| 14 | Add. LWC.@ 1% on total of item Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 10 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender