Tender For Remodelling Of Existing Pump House For Sludge Drain & Construction Of Stp For Supplying Treated Water To Various Parks In Ip Extension & Adjoining Areas.
Tender Value
5.52 Crore
Estimated cost
Bid Submission
14 Aug 2026
18 days left
EMD
5.69 Lakhs
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Remodelling Of Existing Pump House For Sludge Drain & Construction Of Stp For Supplying Treated Water To Various Parks In Ip Extension & Adjoining Areas.
BOQ
| Sl. No. | Item Description |
| 1 | PART-A E&M Work SITC of Mechanical Coarse Screen with conveyer suitable for preliminary treatment of sewage complete in all respects, including frame, screen bars, drive mechanism, fasteners, supports, and accessories.Channel Size: Suitable for channel size Size of Unit : 2.5 m x 0.5 m x 1.0 m SWD; No. of Units : (1W)Nos. Clear Bar Spacing: 20 mm opening & 10mm Bar thickness Drive System: Motor-driven with gearbox and chain/sprocket arrangementPower Consumption: 1.1 KWMotor Protection: IP55 or higherMaterial of Construction (MOC):Screen Bars & Wetted Parts: SS 316Frame & Structural Parts: SS 316 |
| 2 | SITC of Manual Coarse Screen for preliminary treatment of sewage complete in all respects, including frame, screen bars,, fasteners, supports, and accessories.Channel Size: Suitable for channel size 2.5 m x 0.5 m x 1.0 m SWD Clear Bar Spacing: 20 mm opening & 10mm Bar thickness Material of Construction (MOC):Screen Bars & Wetted Parts: SS 316Frame & Structural Parts: SS 316 |
| 3 | Providing & fixing of MS Flange with required nut bolts & packing sheet etc complete as required of following dia: (a) Dia 400 mm ( 25mm thickness) |
| 4 | Providing & fixing of MS blind Flange with required nut bolts & packing sheet etc complete as required of following dia: (a) Dia 200 mm ( 20 mm thickness) |
| 5 | SITC of Raw Sewage Transfer Pumps suitable for transferring raw sewage from inlet sump to downstream treatment units, complete with pump, motor, base frame, coupling, coupling guard, fasteners, and all accessoriesPump Type: Centrifugal PumpService: Raw Sewage TransferCapacity: 200 m³/hr (each pump) Total Number of Pumps: 6 Nos.Head: 15 m (approx.)Suction / Delivery Line Size: individual line 400 mm and common header line 700 mmMotor: TEFC squirrel cage induction motorPower Consumption: 22 KW EachMaterial of Construction (MOC):Pump Casing: SS-304 Impeller: SS-304 Shaft: SS-304Sealing Arrangement: Mechanical seal suitable for raw sewage applicationMounting: Common base frame with anti-vibration pads |
| 6 | SITC of providing fixing of MS enlarger /expander/reducess 150 x 125 mm, 10.00 mm thick, o.5 m length, at site with suitable size nut bolt , packing sheet etc. MOC-MS, Double Flange, 500 mm length |
| 7 | P & F of MS Black Pipe (9.5 mm thickness ) conforming to IS:3589 with required nuts bolts & paking sheet etc complete as required of diameter 400 mm (Gr.330), |
| 8 | P & F of MS Black Pipe (9.5 mm thickness ) conforming to IS:3589 with required nuts bolts & paking sheet etc complete as required of diameter 200 mm (Gr.330) |
| 9 | Providing & fixing of Auto Transformer Starter 40 HP (without oil) confirming to ISS pacification, taping provided from 40%,60% and 80% of line voltage, fitted with fixed and moving contact of ETP grade Copper to provide long life, fitted with 3 magnetic overload relay of dash pot type adjustable from full load to twice of full load, earthing terminal is provided, suitable for places where motor starting load is high etc complete as required. |
| 10 | SITC of Electrical Horizontal Centrifugal Pump Set with non clog impeller to handle storm/mixed/ sewage water having minimum Discharge of 40 m3/hr at Head-15 Mtrs, RPM 1450 RPM (syn) having suction and delivery size 80 mm dia. mounted on a common base frame coupled with Min. 5 HP or suitable rating three phase, 415 volt, 50 Hz supply electrical Motor complete as required. M.O.C. as Casing- C.I., Impeller- C.I., Shaft- 40C8 complete with coupling, coupling guard and foundation bolts. |
| 11 | SITC of 8\\" x 10\\" pump set coupled with air cooled 1500 rpm minimum 32 BHP bhp engine, with following specifications:-1.Engine Type: Diesel Engine.2. Base Frame Material: Mild Steel3. Impeller, body, casing cover: cast iron4. shaft sleeve: Stainless steel5. Battery with leads: 12 V, 150 AH,6. Discharge: 500 m³/hr at 10 m head7. Pump: 8\\" x 10\\" horizontal centrifugal end suction pump. complete with all requisite accessories like fuel tank, etc. suitable to handle storm/ mixed/sewage water complete as required |
| 12 | Supply, installation, Testing & Commissioning of 'Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of 200 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. and consisting of the followings:(A) Diesel Engine:Turbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Degree C, 50% RH & at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWD specifications. (B) Engine mounted In Instrument Panel fitted with and having digital display for following:(i) Start-stop switch with key(ii) Water temperature indication(iii) Lubrication oil pressure indication(iv) Lubrication oil temperature indication(v) Battery charging indication and Voltage indication(vi) RPM indication(vii) Over speed indication(viii) Low lubricantion Oil trip indication(ix) Engine Running Hours indication(x) Fuel Level (C) Alternator: Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation. (D) Base Frame & Foundation:Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. |
| 13 | Providing & fixing of MS Bend with required nut bolts & packing sheet etc complete as required of following dia: (a) Dia 200 mm (8 mm thick) length 0.5 m |
| 14 | Providing & fixing of MS Flange with required nut bolts & packing sheet etc complete as required of following dia: (a) Dia 200 mm ( 20 mm thickness). |
| 15 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required diameter 200 mm dia |
| 16 | Providing , Fixing , testing & commissioning of non rising spindle sluice valve of CI body with wedge bronze ring confirming to ISI 6603 marked complete PN 1.6 complete as required. (a) SV 200 mm |
| 17 | Providing , Fixing , testing & commissioning of non rising spindle sluice valve of CI body with wedge bronze ring confirming to ISI 6603 marked complete PN 1.6 complete as required. (a) SV 400 mm |
| 18 | Replacement of swing type Non Return Valve of CI Body with Door , Bornze to rubber rings confirming to IS 5312 (Part1 & 2), PN 1.6 complete as required. (a) NRV 400 mm |
| 19 | Providing and fixing of MS Platfrom made out of MS Girder size 8''x4\\" (200x100mm) fixing in back side and center supporting with MS angle iron size 50x50x6 mm with cross welding and fixing of MS chequred sheet of 7mm thickness on top side of MS platform back side of platform duly welded MS railing with 2'' dia MS pipe with 3'6'' height to be fixed at site. Complete plate and railing duly painted with enamel paints. |
| 20 | SITC of Main LT Panel power distribution board made out of 1.6 mm sheet steel, epoxy powder coated , specially designed Al bus bar 400A to 630A with heat shrinkcable colour coated sleeves suitable for accommodating MCCBs/MCBs /Isolators as incoming and outgoing as required (without MCCBs/MCBs/Isolators ) complete with digital meter module, including Voltmeter Ammeter with selector switch, CTs control fuse and indicating lights including connections etc. as required ( Conforms to IS:8623)INCOMING -1 (For DHVBN Transformer) 1 400A, FP , 36 KA Microprocessore based. L&T/Schneider/ABB 1R, Y, B Phase Indicating Lamp, 240V AC L&T/Schneider/ABB 3ON/OFF/TRIP Indicating Lamp, 240V AC SWITCH 3Multi Function Meter (MFM). L&T/Schneider/ABB 1400/5A 5VA Resin Cast CL: 1 Ring Type Current Transformer For MFM. AE/Capa 3Surge Suppressor, type B+C with suitable back up Protection. L&T/Schneider/ABB 16A SP 10kA C Curve MCB L&T/Schneider/ABB 6CT-Disconnector Terminals & Neutral Links FTC/Connectwell 7INCOMING -1-1 AUTOMATIC PHASE REVERSAL SYSTEM (FOR DESU ) 1400A, FP , ATS. L&T/Schneider/ABB 1Automatic Phase Sequence Relay: Microprocessor-based, 3-Phase (3P4W) with reverse phase, phase loss, under/overvoltage protection. L&T/Schneider/ABB 1Auxilury Contactors L&T/Schneider/ABB 4Intelligent Controller/PLC: For automating the switchgear sequence based on relay input. L&T/Schneider/ABB 1Busbars: Electrolytic grade Copper/Aluminum Busbars rated for 400A, duly insulated with heat shrinkable sleeves. HINDALCO 3INCOMING -2 (For DG) 1400A, FP , 36 KA Microprocessore based. L&T/Schneider/ABB 1R, Y, B Phase Indicating Lamp, 240V AC L&T/Schneider/ABB 3ON/OFF/TRIP Indicating Lamp, 240V AC L&T/Schneider/ABB 3Multi Function Meter (MFM). L&T/Schneider/ABB 1400/5A 5VA Resin Cast CL: 1 Ring Type Current Transformer For MFM. AE/Capa 36A SP 10kA C Curve MCB L&T/Schneider/ABB 6CT-Disconnector Terminals & Neutral Links FTC/Connectwell 7 AUTO TRANSFER SWITCH ATS 400 A , 4 POLE 1400A, FP ATS L&T 1ON/OFF Indicating Lamp, 240V AC L&T/Schneider/ABB 26A SP 10kA C Curve MCB L&T/Hager/Legrand 2OUTGOING FEEDERS 160A MCCB 160A,36 KA TPN MCCB Thermal Magnetic Base Rel. Prot. L&T/Schneider/ABB 6100A MCCB 100A TP+N MCCB. L&T/Schneider/ABB 263A MCB 63A FP MCB. L&T/Schneider/ABB 440A MCB 40A FP MCB. L&T/Schneider/ABB 4Miscellaneous Item. 1 SetEnclosure 2/1.6mm CRCA for Extention Panel with Cubical type, Single Front, Fixed Type, Floor Mounting TTS Lot400 A, TPN Aluminium Bus Bar. HINDALCO LotCopper PVC Control Wire, Power Wire, Ferul Numbers, Cable Ties, Tie Base, complete as above Polycabe/Finolex/ Dowells LotHardware Nuts, Bolts, Washers, Panel Lock, I-Hooks, Insulators, etc. Reputed Lot |
| 21 | STP PANEL -Supply,Installation, testing and commissioning of power distribution board made out of 1.6 mm sheet steel, epoxy powder coated , specially designed Al bus bar of suitable rating with heat shrinkcable colour coated sleeves suitable for accommodating MCCBs/MCBs /Isolators as incoming and outgoing as required (without MCCBs/MCBs/Isolators ) complete with digital meter module, including Voltmeter Ammeter with selector switch, CTs control fuse and indicating lights including connections etc. as required ( Conforms to IS:8623)INCOMER 1 100A TP+N MCCB Thermal Magnetic Base Rel. Prot. L&T/Schneider/ABB 1 R, Y, B Phase Indicating Lamp, 240V AC L&T/Schneider/ABB 3 ON/OFF/TRIP Indicating Lamp, 240V AC L&T/Schneider/ABB 3 Multi Function Meter (MFM). L&T/Schneider/ABB 1 100/5A 5VA Resin Cast CL: 1 Ring Type Current Transformer For MFM. AE/Capa 3 6A SP 10kA C Curve MCB L&T/Schneider/ABB 6 6A SP 10kA C Curve MCB L&T/Schneider/ABB 6 CT-Disconnector Terminals & Neutral Links FTC/Connectwell 7Earth Bus Bar across the width of Aluminium 25 X 6 mm. HINDALCO 1 OUTGOING FEEDERS 63A TP MCCB with Thermal Magnetic Base Rel. Prot and 7.5 KW Star Delta Starter (Aspirator Aeration Tanks). L&T/Schneider/ABB 325A TP MCB with Thermal Magnetic Base Rel. Prot and 4.5 KW DOL Starter. L&T/Schneider/ABB 325A TP MCB with Thermal Magnetic Base Rel. Prot and 2.2 KW DOL Starter. L&T/Schneider/ABB 7 16A TP MCB with Thermal Magnetic Base Rel. Prot and 1.5 KW DOL Starter. 310A TP MCB with Thermal Magnetic Base Rel. Prot and 1.1 KW DOL Starter. 510A TP MCB with Thermal Magnetic Base Rel. Prot and 0.75 KW DOL Starter. 810A TP MCB with Thermal Magnetic Base Rel. Prot and 0.55 KW DOL Starter. 510A TP MCB with Thermal Magnetic Base Rel. Prot and 0.37 KW DOL Starter. 1040A FP MCB. L&T/Schneider/ABB 232A FP MCB. L&T/Schneider/ABB 232A DP MCB. L&T/Schneider/ABB 2Miscellaneous Item. 1 SetEnclosure 2/1.6mm CRCA for Extention Panel with Cubical type, Single Front, Fixed Type, Floor Mounting TTS Lot200A, TPN Aluminium Bus Bar. HINDALCO LotCopper PVC Control Wire, Power Wire, Ferul Numbers, Cable Ties, Tie Base, complete as above Polycabe/Finolex/ Dowells LotHardware Nuts, Bolts, Washers, Panel Lock, I-Hooks, Insulators, etc. Reputed Lot |
| 22 | LIGHTING DB-4 Way TPN DB Supply, Installation, testing and commissioning TPN MCB DB and comprising of the following, Incoming 63A 4P MCB with all connected accessories – 1 Set. as incomer Outgoing 16A, DP MCB - 4 Nos With necessary COPPER interconnections. |
| 23 | Supply,Installation, testing and commissioning of power distribution board APFC Panel 60 KVAR .INCOMER 1160A,36 KA TPN MCCB Thermal Magnetic Base Rel. Prot. L&T/Schneider/ABB 1R, Y, B Phase Indicating Lamp, 240V AC L&T/Schneider/ABB 3ON/OFF/TRIP Indicating Lamp, 240V AC L&T/Schneider/ABB 3Multi Function Meter (MFM). L&T/Schneider/ABB 1160/5A 5VA Resin Cast CL: 1 Ring Type Current Transformer For MFM. AE/Capa 3Micro Processor based 8 stage Automatic Power Factor Correction Relay with digital Power Factor Meter. L&T/Trinity/Procom 1Auxilliary Contactor with Add on Contact ( 4NO + 4NC ) L&T/Schneider/ABB 2Auto / Manual Selector Switch (1P-2W) L&T/Salzer 16A SP 10kA C Curve MCB L&T/Schneider/ABB 7CT-Disconnector Terminals & Neutral Links FTC/Connectwell 4Earth Bus Bar across the width of Aluminium 50 x 10 mm. HINDALCO 1B Outgoing Feeders 1 25 kVAr Capacitor Bank 1a 63A TP MCB L&T/Schneider/ABB 1b ON/OFF Indicating Lamp, 240V AC L&T/Schneider/ABB 2c Start/Stop Push Buttons with Aux. Contact L&T/Schneider/ABB 2d 25 KVAR Capacitor Duty Contactor. L&T/Schneider/ABB 1 e 25 KVAr Heavy Duty Capacitor Bank L&T/Schneider/ABB 1 f 6A SP 10kA C Curve MCB L&T/Schneider/ABB 4 g CT-Disconnector Terminals & Neutral Links L&T/Schneider/ABB 4 2 10 kVAr Capacitor Bank 2 a 32A TP MCB L&T/Schneider/ABB 2 b ON/OFF Indicating Lamp, 240V AC L&T/Schneider/ABB 4 c Start/Stop Push Buttons with Aux. Contact L&T/Schneider/ABB 4 d 10 KVAR Capacitor Duty Contactor. L&T/Schneider/ABB 2 e 10 KVAr Heavy Duty Capacitor Bank L&T/Schneider/ABB 2 f 6A SP 10kA C Curve MCB L&T/Schneider/ABB 4g CT-Disconnector Terminals & Neutral Links L&T/Schneider/ABB 4 3 5 kVAr Capacitor Bank 2 a 16A TP MCB L&T/Schneider/ABB 2 b ON/OFF Indicating Lamp, 240V AC L&T/Schneider/ABB 4 c Start/Stop Push Buttons with Aux. Contact L&T/Schneider/ABB 4 d 5 KVAR Capacitor Duty Contactor. L&T/Schneider/ABB 2 e 5 KVAr Heavy Duty Capacitor Bank L&T/Schneider/ABB 2 f 6A SP 10kA C Curve MCB L&T/Schneider/ABB 4 g CT-Disconnector Terminals & Neutral Links L&T/Schneider/ABB 4 4 3 kVAr Capacitor Bank 1 a 10A TP MCB L&T/Schneider/ABB 1 b ON/OFF Indicating Lamp, 240V AC L&T/Schneider/ABB 2 c Start/Stop Push Buttons with Aux. Contact L&T/Schneider/ABB 2 d 3 KVAR Capacitor Duty Contactor. L&T/Schneider/ABB 1 e 3 KVAr Heavy Duty Capacitor Bank L&T/Schneider/ABB 1 f 6A SP 10kA C Curve MCB L&T/Schneider/ABB 4 g CT-Disconnector Terminals & Neutral Links L&T/Schneider/ABB 4 5 2 kVAr Capacitor Bank 1 a 10A TP MCB L&T/Schneider/ABB 1b ON/OFF Indicating Lamp, 240V AC L&T/Schneider/ABB 2 c Start/Stop Push Buttons with Aux. Contact L&T/Schneider/ABB 2 d 2 KVAR Capacitor Duty Contactor. L&T/Schneider/ABB 1 e 2 KVAr Heavy Duty Capacitor Bank L&T/Schneider/ABB 1 f 6A SP 10kA C Curve MCB L&T/Schneider/ABB 4 g CT-Disconnector Terminals & Neutral Links L&T/Schneider/ABB 4 Miscellaneous Item. 1 Set 1 Enclosure 2/1.6mm CRCA for Extention Panel with Cubical type, Single Front, Fixed Type, Floor Mounting TTS Lot 2 200A, TPN Aluminium Bus Bar. HINDALCO Lot 3 Copper PVC Control Wire, Power Wire, Ferul Numbers, Cable Ties, Tie Base, complete as above Polycabe/Finolex/ Dowells Lot 4 Hardware Nuts, Bolts, Washers, Panel Lock, I-Hooks, Insulators, etc. Reputed Lot |
| 24 | Supplying, Installation, testing and commissioning of earth pit of minimum dia. 100 mm size 3 mtr. Deep in hard rock soil, through machine or by any suitable means.Earth electrode consisting of 3 mtr. Long and 50 mm Dia. Size Pure copper earth electrode surrounded by highly condective black fill compound chemical 2 bags (25 kg each) with necessary masonry encloser for 300 mm x 300 mm size GI earth pit cover complete as required. (2.002) |
| 25 | Supplying, Installation, testing and commissioning of earth pit of minimum dia. 150 mm size 3 mtr. Deep in hard rock soil, through machine or by any suitable means.Earth electrode consisting of 3 mtr. Long and 80 mm Dia. Size G.I electrode Surrounded by highly conductive black fill compound chemical 2 bags (25 kg each) with necessary masonry encloser for 300 mm x 300 mm size GI earth pit cover complete as required. (2.003) |
| 26 | Supply of XLPE insulated PVC sheathed AL. conductor Armoured cable 1.1 KV grade confirming to IS -7098 of following size -3.5 C *240 sq mm |
| 27 | Supply of XLPE insulated PVC sheathed AL. conductor Armoured cable 1.1 KV grade confirming to IS -7098 of following size -3.5 C *50 sq mm |
| 28 | Supply of XLPE insulated PVC sheathed AL. conductor Armoured cable 1.1 KV grade confirming to IS -7098 of following size -3 C *50 sq mm |
| 29 | Supply of XLPE insulated PVC sheathed AL. conductor Armoured cable 1.1 KV grade confirming to IS -7098 of following size -4 C *6 sq mm |
| 30 | Suplly of XLPE insulated PVC sheathed AL. conductor Armoured cable 1.1 KV grade confirming to IS -7098 of following size -4 C * 10sq mm |
| 31 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 32 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 33 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm |
| 34 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re- filling etc. as required. |
| 35 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 36 | Supply and installation following size of perforated pre-painted M.S cable trays with perforation not more than 17.5% in conveninet sections, jointed with connectors , suspended from the ceiling with M.S suspenders including bolts nuts, painteing suspenders etc as required .300 mm width x 50mm depth X 1.6 mm thickness. |
| 37 | Supply and installation following size of perforated pre-painted M.S cable trays with perforation not more than 17.5% in conveninet sections, jointed with connectors , suspended from the ceiling with M.S suspenders including bolts nuts, painteing suspenders etc as required .150 mm width x 50mm depth X 1.6 mm thickness. |
| 38 | Supply and installation following size of perforated pre-painted M.S cable trays with perforation not more than 17.5% in conveninet sections, jointed with connectors , suspended from the ceiling with M.S suspenders including bolts nuts, painteing suspenders etc as required .100 mm width x 50mm depth X 1.6 mm thickness. |
| 39 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.3 1/2 X 240 sq. mm (62mm) |
| 40 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.3 1/2 X 50 sq. mm |
| 41 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KVgrade as required.3 X 50 sq. mm |
| 42 | Wiring for circuit/ sub -main wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 43 | Wiring for circuit/ sub -main wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 44 | Wiring for circuit/ sub -main wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 45 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, & Ccurve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 46 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 47 | Supply and fixing following rating, double pole 240 V , isolator in the existing MCB DB complete with connections, testing and Commissioning etc. as required.63 A |
| 48 | Brush Less Direct Current (BLDC) Motor Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal ( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply,earthing etc. complete as req. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 49 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 50 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clammped with 1mm thick saddle). |
| 51 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 52 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C |
| 53 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. asrequired. |
| 54 | Supply of 380 mm (15 inch) sweep 1400 rpm exhaust fan fresh Air Type comlete with shutter blades etc. as required. |
| 55 | Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep |
| 56 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 8 way, Double door |
| 57 | (b) 6 way , Double door |
| 58 | (c) 12 Way , Double door |
| 59 | P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd. as reqd. |
| 60 | LED Flood Light, powder coated pressure die cast aluminum (System lumen efficacy ≥120 and <135 lm/Watt). Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg 120deg as per the application and the project requirement deg, suitable tilt able fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 100 watt |
| 61 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency .>85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). CRCA Sheet Body (Thickness ≥ 0.50 mm) 18- 22 watt |
| 62 | Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 63 | Providing and fixing of 4.5 KG CO2 type fire extinguisher sqeeze grip type, trolly wheel as well mounting type complete in all respect with ISI mark i/c fixing arrangement etc as required. |
| 64 | Providing and fixing ABC (Aluminium Phosphate) power type fire extinguisher of 6kgs capacity complete in all respect with isi mark i/c fixing arrangement etc as required. |
| 65 | Supply and fabrication of pole protection system made up 8SWG steel wire mesh of size 25mmX75mm rectangular with 50mmX50mmX6mm MS angle iron for supporting the mesh i/c MV Danger plate and grounding the protection system in |
| 66 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 67 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm |
| 68 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm |
| 69 | Supplying and laying of following size DWC HDPE pipe lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 70 | SITC of 3mm (Min) ACP sheet based acrylic raised letters LED Board with 1\\" x1\\" M.S square pipe box type frame , pipe frame all open sides covered by G.I Sheet preperly |
| 71 | SITC of 50mmX50mmX6mm angle iron mounting stand for ACP sign board and painting with primer and finished paint as required. |
| 72 | Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level |
| 73 | Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 74 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelCold twisted bars |
| 75 | PART -B -STP Type-2 Pump (Sewage Transfer Pump)SITC of Raw Sewage Transfer Pumps (Type-2) suitable for transferring raw sewage from inlet sump to downstream treatment units, complete with pump, motor, base frame, coupling, coupling guard, fasteners, and all accessoriesPump Type: - SubmerssibleService: Raw Sewage TransferCapacity: 20.83 m³/hr (each pump)Total Number of Pumps: 2 Nos.Head: 15 m (approx.)Suction / Delivery Line Size: individual line 100 mm and common header line 100 mmMotor: TEFC squirrel cage induction motorPower Consumption: 3.7KW EachMaterial of Construction (MOC):Pump Casing: SS-304 Impeller: SS-304 Shaft: SS-304Sealing Arrangement: Mechanical seal suitable for raw sewage applicationMounting: Common base frame with anti-vibration pads |
| 76 | Mechanical Fine ScreenSITC of Mechanical Fine Screen with conveyer suitable for preliminary treatment of sewage complete in all respects, including frame, screen bars, drive mechanism, fasteners, supports, and accessories.Channel Size: Suitable for channel size 2.0 m (L) × 0.4 m (W) × 0.7 m SWD Clear Bar Spacing: 20 mm opening & 10mm Bar thickness Drive System: Motor-driven with gearbox and chain/sprocket arrangementPower Consumption: 1.1 KWMaterial of Construction (MOC):Screen Bars & Wetted Parts: SS 316Frame & Structural Parts: SS 316 |
| 77 | Manual Fine Screen SITC of Manual Fine Screen suitable for preliminary screening of raw sewage at inlet channel, complete with frame, screen bars, lifting hooks, supports, and all necessary accessoriesChannel Size: Suitable for channel size 2.0 m (L) × 0.4 m (W) × 0.7 m SWDClear Bar Spacing: 6 mm opening & 2 mm Bar thicknessOperating Mode: Manual rakingMaterial of Construction (MOC):Screen Bars & Wetted Parts: SS 316Frame & Supporting Members: SS 316 |
| 78 | Oil skimmer mechanismSITC of oil skimmer mechanism suitable for preliminary oil & grease removal of raw sewage at inlet channel, complete with skimmer assembly, frame, lifting hooks, supports, anchor bolts, fasteners, and all necessary accessories Material of Construction (MOC):Skimmer Assembly & Wetted Parts: SS-316Frame & Supporting Structure: SS-316Size of Unit :2.4 m x 1.5 m x 1.0 m SWD + 0.50 FB; No. of Units : 1 No.Power Consumption: 1.1 KW |
| 79 | Mechanical Grit UnitSITC of mechanical grit unit suitable for removal of grit and heavy inorganic particles from raw sewage during preliminary treatment, complete with grit removal mechanism, drive arrangement, frame, supports, anchor bolts, fasteners, and all necessary accessories,Application: Preliminary Treatment – Grit RemovalUnit Size: 0.8 m (L) × 0.8 m (W) × 0.6 m LDGrit Contact & Wetted Parts: SS-316Power Consumption: 2.2 KW EachFrame & Supporting Structure: SS / MS epoxy coated, suitable for sewage envionment |
| 80 | Parshall Flume with Ultrasonic Flow Meter-SITC of Parshall flume complete with ultrasonic non-contact flow meter suitable for measurement of raw sewage flow at inlet channel, including flume section, ultrasonic sensor, transmitter, mounting supports, cabling, fasteners and all necessary accessoriesOverall length 3.0 m; Channel width 1.0 m; Throat width 0.152 m; Water depth 0.5 m SWD + 0.5 m FBParshall Flume with Ultrasonic Flow MeterFlume body: RCC / FRP / SS; Meter housing & wetted parts: SS / corrosion-resistant material |
| 81 | Equalisation tank Submersible MixersSITC of submersible mixers suitable for mixing and homogenisation of sewage in equalisation tank, complete with submersible motor, mixer assembly, guide rail arrangement, lifting chain, mounting accessories, anchor bolts, fasteners and all necessary fittingsTank capacity: 172.374 m³Submersible MixerPower Consumption: 4.5 KW EachMixer body, shaft & wetted parts: SS-316No.2 |
| 82 | Anoxic of submersible mixers suitable for mixing and homogenisation of sewage in equalisation tank, complete with submersible motor, mixer assembly, guide rail arrangement, lifting chain, mounting accessories, anchor bolts, fasteners and all necessary fittingsTank capacity: 21.55 m³Submersible MixerPower Consumption: 0.37 KW EachMixer body, shaft & wetted parts: SS-316No.2 |
| 83 | MBBR Tank-1-2SITC, filling and commissioning of MBBR bio media suitable for biological treatment in MBBR Tank-1 and Tank-2, including required quantity of media with specific surface area 2500–3000 m²/m³, complete with all accessories, as per approved drawings and datasheet.Tank capacity: 11.191 m³ (each tank)MBBR Bio MediaMedia material: HDPE / equivalent; 2 No. of Tank. |
| 84 | Internal Recirculation PumpsSITC of internal recirculation pumps suitable for process liquid recirculation, complete with pump, motor, base frame, coupling, coupling guard, anchor bolts, fasteners and all necessary accessories.6 m³/hr, 10 m (approx.)Power Consumption: 0.55 KW EachProgressive Cavity Pump / Rotary Lobe PumpAs per vendor designPump casing: SS-304; Rotor/Screw: SS-304 / SS-316; Shaft: SS-410 / SS-316 |
| 85 | Return Activated Sludge PumpsSITC of submersible pumps suitable for return activated sludge recirculation, complete with submersible motor, guide rails, lifting chain, mounting accessories and all fittings.33 m³/hr, 10 m (approx.)Power Consumption: 2.2 KW EachSubmersible PumpAs per vendor designWetted parts: SS-304No. 2 |
| 86 | Air BlowerSITC of blower suitable for aeration in STP / process tanks, complete with blower assembly, drive motor, base frame, coupling, coupling guard, fasteners and all necessary accessories.90 Nm³/hr, 8 m (approx.)Power Consumption: 1.1 KW EachTwin-Lobe / Tri-Lobe / CentrifugalAs per vendor designBlower casing/housing: DI – EN-GJS-400 / SG Iron; Shaft: SS-304; Impeller/rotor: SS-304No. 3 |
| 87 | Tube Settler MediaSITC of tube settler media suitable for solid-liquid separation in sedimentation / clarifier tanks, complete with media supports and necessary accessories, as per approved drawings and datasheet.4.5 m³Chevron type, black coloured mediaNot applicableHigh-density polymer / corrosion-resistant plastic; |
| 88 | Sludge Transfer PumpsSITC of pumps suitable for sludge transfer, complete with drive motor, base frame, coupling, coupling guard, fasteners and all necessary accessories, as per approved drawings and datasheet.1 m³/h, 10 m (approx.)Power Consumption: 0.37 KW EachScrew Type / Progressive Cavity Pump / Rotary Lobe PumpPump casing: SS-304; Rotor/Screw: SS-304 ; Shaft: SS-304No.2 |
| 89 | Chlorinator for Chlorine Disinfection system SITC of chlorinator units suitable for treated water disinfection, complete with dosing pump, reactor, valves, mounting accessories and all necessary fittings, as per approved drawings and datasheet.0.5 kg/h; Voltage 220–240 V / 50–60 Hz; IP65; Max. 80 psi / 85°C, Chlorinator Unit Reactor: SS 304No. 2 |
| 90 | Filter Feed PumpSITC of submersible pumps suitable for Treated Water Transfer Pump, complete with submersible motor, guide rails, lifting chain, mounting accessories and all fittings.26.0 m³/hr, 25 m (approx.) of 3.7 KW power consunmptionSubmersible PumpWetted parts: SS-304No. 2 |
| 91 | Pressure Sand FilterSITC of pressure sand filter suitable for water filtration, complete with filter vessel, media support system, valves, piping connections, and all accessories.Dia 1.7 m × 2.0 m SWD + 0.5 m FBPressure Sand FilterVessel: SS ; Internals: SS / PVC / HDPENo.1 |
| 92 | Activated Carbon FilterSITC of activated carbon filter suitable for water filtration, complete with filter vessel, media support system, valves, piping connections, and all accessories, as per approved drawings and datasheet.Dia 1.6 m × 2.0 m SWD + 0.5 m FBActivated Carbon FilterNot applicableVessel: SS ; Internals: SS / PVC / HDPENo.1 |
| 93 | Sludge Transfer PumpsSITC of pumps suitable for sludge transfer, complete with drive motor, base frame, coupling, coupling guard, fasteners and all necessary accessories, as per approved drawings and datasheet.1 m³/h, 10 m (approx.)Screw Type / Progressive Cavity Pump / Rotary Lobe PumpPump casing: SS-304; Rotor/Screw: SS-304 ; Shaft: SS-304No.2 |
| 94 | Sludge Sump Submersible Mixers SITC of submersible mixers suitable for mixing and homogenisation of sewage in equalisation tank, complete with submersible motor, mixer assembly, guide rail arrangement, lifting chain, mounting accessories, anchor bolts, fasteners and all necessary fittingsTank capacity: 2.90 m³Power Consumption: 0.37 KW EachSubmersible MixerMixer body, shaft & wetted parts: SS-304No.2 |
| 95 | Filter press Feed Pumps SITC of pumps suitable for sludge transfer, complete with drive motor, base frame, coupling, coupling guard, fasteners and all necessary accessories, as per approved drawings and datasheet.1.1 m³/h, 10 m (approx.)Power Consumption: 0.37 KW EachScrew Type / Progressive Cavity Pump / Rotary Lobe PumpPump casing - SS-304; Rotor/Screw: SS-304 ; Shaft: SS-304 No.2 |
| 96 | Filter pressSITC of filter press suitable for sludge dewatering, complete with filter press unit, gearbox, drive system, fabricated base frame, panels, accessories, and all necessary fittings.1.1 m³/hFilter PressAs per vendor design; RPM 100Wetted parts: SS-304 ; Base: Fabricated; Gearbox make: SEW / Bonfiglioli / Equivalent;No.2 |
| 97 | DWPE Dosing SystemSITC of DWPE Dosing System suitable for increasing sludge concentration prior to the dewatering unit, complete with dosing pump, gearbox, drive system, fabricated base frame, control panel, all accessories, and necessary fittings for complete and efficient operation.DWPE Dosing System,Capacity of Pump15 LPH quantity: 3 Nos.Power Requirement:PP Head & PVC FittingsFor sludge concentration improvement in dewatering unit |
| 98 | DWPE TankSITC of dosing tank of MOC: MSEP/HDPE (High Density Polyethylene)/PP/FRP (Fiber Reinforced Plastic) |
| 99 | Submersible Mixer SITC of submersible mixers suitable for mixing and homogenisation of sewage in equalisation tank, complete with submersible motor, mixer assembly, guide rail arrangement, lifting chain, mounting accessories, anchor bolts, fasteners and all necessary fittingsTank capacity: 0.2 m³Submersible MixerMixer body, shaft & wetted parts: SS-304 No.2 |
| 100 | Centrate PumpsSITC of Centrate Transfer Pumps (Type-1) suitable for transferring to sump to treatment units, complete with pump, motor, base frame, coupling, coupling guard, fasteners, and all accessoriesPump Type: Centrifugal Pump – HorizontalService:Centrate Transfer PumpCapacity: 1.10 m³/hr (each pump)Total Number of Pumps: 2 Nos.Head: 15 m (approx.)Suction / Delivery Line Size: individual line 400 mm and common header line 700 mmMotor: TEFC squirrel cage induction motorPower Consumption: 1.1 KW EachMaterial of Construction (MOC):Pump Casing: SS-304 Impeller: SS-304 Shaft: SS-304Sealing Arrangement: Mechanical seal suitable for raw sewage applicationMounting: Common base frame with anti-vibration pads |
| 101 | Treated Water Transfer PumpSITC of submersible pumps suitable for Treated Water Transfer Pump, complete with submersible motor, guide rails, lifting chain, mounting accessories and all fittings.21 .0 m³/hr, 25 m (approx.) of 3.7 KW power consunmptionSubmersible PumpWetted parts: SS-304No. 2 |
| 102 | Air Blower for filter SITC of blower suitable for aeration in STP / process tanks, complete with blower assembly, drive motor, base frame, coupling, coupling guard, fasteners and all necessary accessories.240 Nm³/hr, 8 m (approx.)Power Consumption: 1.1 KW EachTwin-Lobe / Tri-Lobe / CentrifugalBlower casing/housing: DI – EN-GJS-400 / SG Iron; Shaft: SS-304; Impeller/rotor: SS-3-4No. 3 |
| 103 | Backwashing pumpSITC of Backwash Pumps 33 .0 m³/hr, 15 m (approx.) of 3.7 suitable for transferring to sump to treatment units, complete with pump, motor, base frame, coupling, coupling guard, fasteners, and all accessoriesPump Type: Centrifugal Pump – Horizontal pumps |
| 104 | UV DisinfectionSITC of UV disinfection system suitable for treated water disinfection, complete with UV reactor, lamps, power SITC/ballast, mounting supports, piping connections and all necessary accessories.21.55 m³/hUV Disinfection SystemPower Consumption: 1.1 KW EachAs per vendor design; Voltage 220–240 V / 50–60 Hz, IP65No. 1 |
| 105 | STP interconnection pipe lineSITC of pipes having size of 80 mm , conforming IS IS 4984:2016 ,PN 10.MOC -HDPE OD - 90 mm |
| 106 | SCADA SystemSITC of Programmable Logic Controller (PLC) panel, CPU (Siemens/Allen Bradley / Mitsubishi or equivalent), I/O modules, power supply, HMI (10\\"), enclosed in IP55 panel. Designation Description Make Qty 1 CPU1 FX5U;CPU Mitsubishi 1 2 BH1 Header Module Mitsubishi 1 3 DI1-11 Digital IO Module Mitsubishi 11 4 DO1-3 Digital IO Module Mitsubishi 3 5 AI1-AI3 Analog IO Module Mitsubishi 3 6 AO1,2 Analog IO Module Mitsubishi 2 7 BEM1 System Module Mitsubishi 1 8 ETHSW1 Unmanaged Ethernet Switch-Din Rail Mountable Phoenix 1 9 CMN-CBL Ethernet Communication Cable EEPL Std. 2 10 P Control Panel With Two Mounting Plates, Front & Rear Door ith A Size Drawing Pocket EEPL Std. 1 11 L1 Red Colour LED Indication Lamp L&T 1 12 L2 Red Colour LED Indication Lamp L&T 1 13 F1-F2 Fan-6 Inch Clasiair 2 14 F1-F2 Metal Finger Guard Clasiair 2 15 FILTER Filter-6 Inch,RAL-7035 Elettro 4 16 DLS1,2 Door Limit Switch With Plastic Protective Cover Kaycee 2 17 TL1,2 Tube Light-LED(Cisa Battern) Sturlite 2 18 Q2.1 MCB(SB202 M-C25) ABB 1 Page | 12 19 Q2.1A MCB(SB202 M-C10) ABB 1 20 Q2.2,2.3, 2.1A,2A MCB(SB202 M-C6) ABB 4 21 Q2.4,2.5 MCB(SB202 M-C4) ABB 2 22 PS1 Power Supply-Din Rail Mounting Multispan 1 23 RLB1-RLB10 8 Channel Relay Board,PC24D08-CNB-SO2 Phoenix 10 24 SKT1 Universal Power Socket EEPL Std.. 1 25 EB Earth Bolt EEPL Std. 2 26 PE Panel Earth (Copper) EEPL Std. 1 27 SE System Earth (Copper) EEPL Std. 1 28 BB1,BB2 24VDC/0VDC BusBars (Copper) EEPL Std. 2 29 XFTB Fuse Terminal Block-TB 4-HESI(5x20) EI Phoenix 2 30 XFTB 5x20mm Miniature Glass Fuse Links Protectron 2 31 230VAC,0VAC Normal Terminal Block-TB 2.5 EI Phoenix 10 32 XDI,XDI-11 Fuse Terminal Block-TB 4-HESI(5x20) EI Phoenix 65 33 XDI,XDI-11 Normal Terminal Block-TB 2.5 EI Phoenix 208 34 XDI,XDI-11 5x20mm Miniature Glass Fuse Links Protectron 65 35 XDO-10 Fuse Terminal Block-TB 4-HESI(5x20) EI Phoenix 80 36 XDO-10 Normal Terminal Block-TB 2.5 EI Phoenix 80 37 XDO-10 5x20mm Miniature Glass Fuse Links Protectron 80 38 XAI-3 Fuse Terminal Block-TB 4-HESI(5x20) EI Phoenix 48 39 XAI-3 Normal Terminal Block-TB 2.5 EI Phoenix 48 40 XAI-3 5x20mm Miniature Glass Fuse Links Protectron 24 41 XAI-3 5x20mm Miniature Glass Fuse Links Protectron 24 42 XAO Fuse Terminal Block-TB 4-HESI(5x20) EI Phoenix 8 43 XAO Normal Terminal Block-TB 2.5 EI Phoenix 16 44 XAO 5x20mm Miniature Glass Fuse Links Protectron 8 45 XPTB1,2 Normal Terminal Block-TB 10 EI Phoenix 6 46 EP Normal Terminal Block End Plate-D-TB 2.5 E Phoenix 23 47 EP Fuse Terminal Block End Plate-D-TB 4-HESI EI Phoenix 13 48 EP Normal Terminal Block End Plate-D-TB 4/10 E Phoenix 2 49 CBL Internal Cables Polycab 1 Lot 50 ACC Accessories EEPL Std. 1 Lot 51 SW Cimplicity Server Standard Runtime GE 1 52 PC Personal Computer With Windows11 Professional 64 Bit With USB Type Keyboard & Mouse HP/Dell 1 53 MON LED Monitor 21” HP/Dell 1 54 UPS 1kVA Online UPS APC/Eq 1 55 PR Printer-A3 Size BKW HP/Eq 1 SITC of instrumentation for the STP, complete with all fittings, accessories, control panels, mounting arrangements, and necessary components for proper and reliable operation. INSTRUMENTATION |
| 107 | Pressure Gauges Mechanical deformation of Bourdon tube (elastic metal tube tends to straighten under applied pressure); Range:- 0~6 bar ; Resolution ratio:- 1% of full scale; Precision:- ±1.6% F.S.; Output mode:- Analog (dial type local indication); Working conditions:- 0~60℃ & up to rated pressure; Storage temperature:- -20~70℃; Installation mode:- Direct mounting on pipelines / pumps with threaded connection (bottom entry); Power Supply:- Not required; Levels of protection:- IP65 (weatherproof, glycerin-filled for vibration resistance); Response time:- Instantaneous; Maintenance |
| 108 | Level SwitchesMeasuring principle:- Float / Conductivity / Capacitive / Vibrating fork method; Range:- Point level detection (High/Low level); Resolution ratio:- Not applicable (discrete switching device); Precision:- ±1% of switching point; Output mode:- Relay output (NO/NC) / PNP-NPN; Working conditions:- 0~60℃ & up to 1MPa (depending on type); Storage temperature:- -10~70℃; Installation mode:- Side mounting / Top mounting / Threaded or flanged connection; Power Supply:- 12 VDC / 24 VDC / 230 VAC; Levels of protection:- IP65/IP67; Response time:- ≤1 second |
| 109 | Level ControllerMeasuring principle:- Signal processing from level sensors (ultrasonic / pressure / float / differential level transmitter); Range:- As per connected sensor (typically 0~10 m or more); Resolution ratio:- 1 mm or 0.1% of span; Precision:- ±0.25% F.S.; Output mode:- Relay output / 4-20 mA / RS-485 Modbus / HART; Working conditions:- 0~50℃ & <0.3MPa; Storage temperature:- -10~60℃; Installation mode:- Panel mounting / Wall mounting; Power Supply:- 24 VDC / 230 VAC; Levels of protection:- IP65 (panel front); Response time:- ≤1 second; Maintenance |
| 110 | OMSMeasuring principle:- Optical (Infrared scattered light/ nephelometric method); Range:- 0~-30,000 mg/L Resolution ratio:- 1 mg/L; Precision:- ±5% F.S.; Output mode:- RS-485/ Modbus/ RTU / 4-20 mA; Working conditions:- 0~50℃ & <0.3MPa; Storage temperature:- 0~60℃; Installation mode:- Immersion mounting with protective holder; Power Supply:- 12 VDC / 24 VDC; Levels of protection:- IP68; Response time:- ≤60 seconds; Maintenance:- Periodic cleaning with automatic wiper/air cleaning system |
| 111 | DO AnalyzerInstallation of DO Sensor in Aeration Tank Measuring principle:- Fluorescence method; Range:- 0~20mg/L (0 - 200% saturation @ 25℃); Resolution ratio:- 0.01 mg/L, 0.1℃; Precision:- ±2%F.S. & ±0.3℃; Output mode:- RS-485/ Modbus/ RTU; Working conditions:- 0~45℃ & <0.2MPa; Storage temperature:- 0~60℃; Installation mode:- Immersion mounting; Power Supply:- 12 VDC; levels of protection:- IP68 |
| 112 | MLSS AnalyzerMeasuring principle:- Optical (Infrared scattered light method); Range:- 0~20,000 mg/L ; Resolution ratio:- 1 mg/L; Precision:- ±5% F.S.; Output mode:- RS-485/ Modbus/ RTU; Working conditions:- 0~45℃ & <0.2MPa; Storage temperature:- 0~60℃; Installation mode:- Immersion mounting; Power Supply:- 12 VDC / 24 VDC; Levels of protection:- IP68 |
| 113 | Water Level IndicatorMeasuring principle:- Ultrasonic / method; Range:- 0~10 m Resolution ratio:- 1 mm; Precision:- ±0.25% F.S.; Output mode:- RS-485/ Modbus/ RTU / 4-20 mA; Working conditions:- 0~50℃ & <0.3MPa; Storage temperature:- 0~60℃; Installation mode:- Top mounting (ultrasonic) / Submersible (hydrostatic); Power Supply:- 12 VDC / 24 VDC; Levels of protection:- IP68 (sensor), IP65 (controller); Response time:- ≤1 second; Maintenance |
| 114 | Differential Level TransmitterMeasuring principle:- Differential pressure (hydrostatic head measurement); Range:- 0~10 mWC (meter of water column) or as per application; Resolution ratio:- 0.1% of span; Precision:- ±0.1% to ±0.25% F.S.; Output mode:- 4-20 mA / HART / RS-485 Modbus; Working conditions:- -10~80℃ & up to 1MPa (depending on model); Storage temperature:- -20~85℃; Installation mode:- Wall/pipe mounting with impulse lines (high & low pressure sides); Power Supply:- 24 VDC; Levels of protection:- IP65/IP67; Response time:- ≤1 second |
| 115 | PART C: Dismantling work IP Extn. Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 116 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge: In cement mortar |
| 117 | Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured) : From brick work in cement mortar |
| 118 | Extra for scrapping, cleaning and straightening reinforcement from R.C.C. or R.B. work. |
| 119 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : Of area 3 sq. metres and below |
| 120 | Of area beyond 3 sq. metres |
| 121 | Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in: Channels, angles, tees and flats |
| 122 | Carriage of materials by Mechanical Transport including loading, unloading and stacking of Earth:- (Note:- Rate shall be applicable for net quantity after deduction of prescribed rate of voids ) Building Rubbish, Lime, Moorum (Lead 5 Km |
| 123 | PART D CIVIL Work Carriage of earth upto 3 km |
| 124 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.2.6.1 All kinds of soil |
| 125 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means infoundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 All kinds of soil. |
| 126 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc.in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. |
| 127 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.2.28.1 All kinds of soil |
| 128 | Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4 (1 cement: 2coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 129 | Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.4.20.1 All works upto plinth level4.20.1.2 Concrete of M15 grade with minimum cement content of 240 kg /cum |
| 130 | Centering and shuttering including strutting, propping etc. and removal of form forFoundations, footings, bases of columns, etc. for mass concrete |
| 131 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc |
| 132 | Suspended floors, roofs, landings, balconies and access platform |
| 133 | Shelves (Cast in situ) |
| 134 | Centering and shuttering including strutting, propping etc. and removal of form for5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 135 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 136 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing inposition and binding all complete upto plinth level. |
| 137 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing inposition and binding all complete above plinth level. |
| 138 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.5.33.1 All works upto plinth level5.33.1.1 Concrete of M25 grade with content of 330 kg /cum minimum cement |
| 139 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.5.33.1 All works upto plinth level5.33.1.2 Concrete of M30 grade with content of 350 kg /cum minimum cement |
| 140 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.5.33.2 All works above plinth level upto floor V level5.33.2.1 Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 141 | Providing and laying in position ready mixed or site batched design mix cement concrete forreinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.5.33.2 All works above plinth level upto floor V level5.33.2.2 Concrete of M30 grade with minimum cement content of 350 kg /cum |
| 142 | Brick work with common burnt clay modular bricks of class designation 7.5 in foundation andplinth in:- Cement Mortar 1:6 (1 cement : 6 coarse sand) |
| 143 | Brick work with common burnt clay machine moulded perforated bricks of class designation12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement: 6 coarse sand):6.3.1 With F.P.S.(non modular) bricks |
| 144 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 insuperstructure above plinth level up to floor V level in all shapes and sizes in :6.4.2 Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 145 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness tobe specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 146 | Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).9.1.3 Kiln seasoned and chemically treated hollock wood |
| 147 | Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS : 14616 and TADS 15:2001 (Part B), fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer- in-charge and panelling with panels of : (Note:- Butt hinges and necessary screws shall be paid separately)9.6.2 12 mm thick pre-laminated particle board (decorativelamination on both sides) grade -1, medium density flat pressed, three layer particle board FPT-I or graded wood particle board FPT- I, conforming to IS : 3087, bonded with BWP type synthetic resin adhesive as per IS : 848 and pre-laminated conforming to IS : 12823, Grade 1, Type - II marked. |
| 148 | Two track four panels sliding windows with Aluminium channel for roller track, wool pile, zinc alloy (zamak) powder coated handle on three panels along with multi-point locking system, nylon rollers with SS 304 body. - Using R4 series with frame (64 mm & above)x (45 mm & above) & sash (44 mm & above) x (55 mm & above) (Height above 1.8m). |
| 149 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specifiedby the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 150 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by themanufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete11.4 .2 Size of Tile 600x600mm |
| 151 | 12 mm cement plaster 1:4 (1 cement : 4 fine sand) |
| 152 | 12 mm cement plaster finished with a floating coat of neat cement of mix : - 1:4 (1 cement: 4fine sand) |
| 153 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat ofneat cement of mix : - 1:4 (1 cement: 4 fine sand |
| 154 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). |
| 155 | 6 mm cement plaster of mix : 13.16.1 1:3 (1 cement : 3 fine sand) |
| 156 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface toprepare the surface even and smooth complete. |
| 157 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including waterthinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 158 | Finishing walls with Acrylic Smooth exterior paint of required shade :13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 159 | Providing and laying 75 mm thick compacted bed of dry brick aggregate of 40 mm thicknominal size including spreading, well ramming, consolidating and grouting with jamuna sand, including finishing smooth etc. complete as per direction of Engineer-in-charge |
| 160 | Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS :8329 : 400 mm dia Ductile Iron Class K-7 pipes |
| 161 | Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design |
| 162 | Providing and fixing in position precast R.C.C. manhole cover and frame.19.19.2.2 Circular shape 500mm internal diameter |
| 163 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or gradedwood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. - Pre-laminated particle board with decorative lamination on both sides |
| 164 | Providing and Placing in position suitable PVC water stops conforming to IS:12200 forconstruction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete :22.4.1 Serrated with central bulb (225 mm wide, 8-11 mm thick) |
| 165 | PART E: Piping work for supply to various parks for Horticulture purposes at I.P. Extension SPS CARRIAGE OF MATERIALS:- By Mechanical Transport including loading,unloading and stacking (5 km) |
| 166 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, includinggetting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 167 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm indepth: consolidating each deposited layer by ramming and watering, lead up to 50m and lift up to 1.5m. |
| 168 | Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.4.20.1 All works upto plinth level4.20.1.2 Concrete of M15 grade with minimum cement content of 240 kg /cum |
| 169 | Suspended floors, roofs, landings, balconies and access platform |
| 170 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete uptoplinth level. |
| 171 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.5.33.1 All works upto plinth level5.33.1.1 Concrete of M25 grade with content of 330 kg /cum minimum cement |
| 172 | Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:6.2.2 Cement Mortar 1:6 (1 cement: 6 coarse sand). |
| 173 | 12 mm cement plaster finished with a floating coat of neat cement of mix :13.7.2 1:4 (1 cement: 4 fine sand) |
| 174 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix13.8.2 1:4 (1 cement: 4 fine sand) |
| 175 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.15.2.1 Nominal concrete 1:3:6 or leaner mix (including equivalentdesign mix) |
| 176 | Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge :15.43.2 bituminous road |
| 177 | Providing and laying 75 mm thick compacted bed of dry brick aggregate of 40 mm thick nominal size including spreading, well ramming, consolidating and grouting with jamuna sand, including finishing smooth etc. complete as per direction of Engineer-in-charge. |
| 178 | Providing and laying C.C. pavement of mix M-25 with ready mixed concretefrom batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately).(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately). |
| 179 | Providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50mx2.00m made of 40x40x6mm angle iron or 50x50x3mm hollow MS tube posts/horizontal members/bracings covered with 1.63mm thick MS sheet. The sheet shall be fixed with 30x5mm MS flat by suitable welding/riveting. The panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5m. MS channel ISLC 75 @ 5.70 kg/m, 50cm long shall be provided at the bottom having oval shaped holes of size 50x25mm at both ends with 50cm long MS angle 40x40x6mm bracing. Suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250mm long expansion fasteners at both ends. The work shall be executed as per drawing/direction of Engineer-in-Charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineerin-Charge.(Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completionof the work). |
| 180 | Providing and fixing brass stop cock of approved quality :20 mm nominal bore |
| 181 | Providing flanged joints to double flanged C.I./D.I. pipes and specials,including testing of joints: 100 mm Dimeter Pipe |
| 182 | Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) :18.31.1.2 Class II |
| 183 | Providing & Fixing in position Single orifice Air Valve and providing saddle clamp or flanged joints (one no. ) i.c cost bolts, nuts, rubber insertion etc. (3mm th.two washers for each bolt) all complete i/c taxes, transporation, loading, unloading, erection, testing to the specified head by filling water as per specification and as directed by Engineer-in-charge.100 mm dia |
| 184 | Providing and fixing C.I. dirt box strainer for bulk type water meter with nuts, bolts, rubber insertions etc. complete conforming to IS : 2373.100 mm dia |
| 185 | Providing and laying D.I. specials of class K-12 suitable for push-on joints as per IS:9523. Up to 600mm dia. |
| 186 | Providing push-on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and the cost ofrubber gasket :100 mm dia pipes |
| 187 | Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329. 100 mm dia Ductile IronClass K-7 pipes |
| 188 | Providing and laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K - 9 conforming to IS : 8329 :100 mm dia Ductile Iron Double Flanged |
| 189 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality. EHD - 3519.19.4.1 Circular shape 560 mm internal dia Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 25, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysAug 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender