Tender For Supply, Installation, Testing And Commissioning (Sitc) Of 150 Tonnage Capacity (Minimum) Air Cooled Chiller With Adiabatic Cooling Kit Against Buyback Of 150 Tonnage Capacity Air Cooled Chiller At Rrcat, Indore.
Tender Overview
Project Description
Tender for Supply, Installation, Testing And Commissioning (Sitc) Of 150 Tonnage Capacity (Minimum) Air Cooled Chiller With Adiabatic Cooling Kit Against Buyback Of 150 Tonnage Capacity Air Cooled Chiller At Rrcat, Indore.
BOQ
| Sl. No. | Item Description |
| 1 | Supply, installation, testing and commissioning (SITC) of 150 Tonnage capacity (minimum at 45 degC) Air Cooled Chiller with adiabatic cooling kit against buyback of 150 tonnage capacity Air Cooled Chiller (Make Blue Star, Model no. LCAX2-1055D) as per technical specification. |
| 2 | Supply, Installation,Testing and Commissioningof Eurovent/AHRI certified Aircooled chiller as per tender specification of 150 TR actual capacity at 45 degC ambient temperature (without adiabatic kit) and operating conditions as given below with screw compressors with VFD and single refrigerant circuits operating on refrigerant R-134a/equivalent or better driven by suitable motor, air-cooled condenser copper tubes & fins with anti corrosion coating, flooded/DX type shell & tube evaporator,VFD on condenser fans, flow switches at chiller inlet/outlet, initial refrigerant & oil charged from the factory, microprocessor based control panel, spring isolators of suitable capacity all mounted on M.S. frame.Chiller shall be BMS compatible with its control panel having BACnet/Modbus/IP based network platform with ethernet/RS-485 port for compatible with existing PLC based system. The motor shall be with class 'F' Insulation suitable for 415 volts ±10%, 50Hz± 5 %, three phase AC supply. Factory testing of the chiller at AHRI approved test bed. |
| 3 | Site Operating Parameters |
| 4 | Air Entering Temp. to the Condenser: 45ºC |
| 5 | Chiller :- CHW in at 12 ºC & CHW Out at 7ºC |
| 6 | Chiller Fouling Factor - 0.0001 FPS |
| 7 | Chilled Water Flow: As per AHRI |
| 8 | Total Pr.Drop: < 7 Meters of water |
| 9 | C.O.P at AHRI condition (35degC): 3.1 minimum. (without adiabatic cooling kit) |
| 10 | IPLV (SI): 5 min. (without adiabatic cooling kit) |
| 11 | OEM must give the performance of chiller at 45ºC |
| 12 | All Performance parameters shall be strictly as per technical specification Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 21 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 24 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender