Educational and Research Institute Government Departments Closing in 15 days TDR #56654533

Tender For Aluminum Partition Work And Pre-Painted Profile Sheet Barricading For Store Area Including Painting, Electrical And Air Conditioning Works For Pmdk At Crc Lucknow

Issued by Government Departments · Lucknow, Uttar Pradesh
Tender Value
19.26 Lakhs
Estimated cost
Bid Submission
11 Aug 2026
15 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Lucknow → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Aluminum Partition Work And Pre-Painted Profile Sheet Barricading For Store Area Including Painting, Electrical And Air Conditioning Works For Pmdk At Crc Lucknow

BOQ

Name of Work:- Aluminum Partition Work and Pre-Painted Profile Sheet Barricading for Store Area Including Painting, Electrical and Air Conditioning Works for PMDK at CRC Lucknow
Sl. No. Item Description
1Demolishing cement concrete manually/ by mechanical means including disposal of material outside of Campus Government of India Guide Line/ Engineer-in-charge. Nominal concrete 1:3:6 or richer mix (including equivalent design mix)
2Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material outside of Campus as per Government of India guidelines/Engineer-in-charge.
3Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish /unserviceable material outside of Campus Government of India guidelines/ Engineer-in-charge.
412 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) including supply of all Material, labour and T&P etc Complete.
5Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc.including disposal of unserviceable material outside of Campus Government of India Guide Line/ Engineer-in-charge. (Make - Asian, Nerolac or equivalent )
6Finishing walls with Acrylic Smooth exterior paint of required shade : Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface sqm (Make - Asian, Nerolac or equivalent )
7Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (Make - JK,Asian,Birla or equivalent)
8Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour Old work (Two or more coats) (Make - Asian,Nerolac or equivalent )
9Cleaning & Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work including Supply of all material ,Labour and T&P etc Complete.
10Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) Makes : Saint Gobain, Asahi, Pilkington, Modiguard or equivalent as approved
11Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mmthick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm,cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphey wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. With 15 mm thick Tegular edged light weight calcium sliciate false ceiling tiles Makes : Gyproc of Saint gobain / USG Boral / Approved equivalent
12Providing and fixing aluminium work for doors, windows, Partition work , ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
13Providing and fixing aluminium work For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)
14Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides. Makes : Jacsons (Exterior grade), Associate or equivalent as approved
15Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness Makes : Dorma, Ozone Overseas Pvt Ltd, Dorset kaba Security Systems Pvt Ltd, Godrej, Everite Agencies, Dyna, Door King, Hettich India Pvt Ltd or equivalent as approved
16Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. Makes : Dorma, Ozone Overseas Pvt Ltd, Dorset kaba Security Systems Pvt Ltd, Godrej, Everite Agencies, Dyna, Door King, Hettich India Pvt Ltd or equivalent as approved
17Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
18Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 20 mm nominal dia Pipes
19Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 including cutting, jointing, wastage, but excluding cost of N jointing Single Socket Type B for (Internal Toilet and external wall) - 110mm dia SWR UPVC pipe lines laid complete
20Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. Makes : Kajaria, Regency, Nitco, Rak, or equivalent as approved
21Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works Makes : Tata, SAIL, Jindal Steel and Power Ltd, or equivalent as approved
22Centering and shuttering including strutting, propping etc. and removal of form Suspended floors, roofs, landings, balconies and access platform
23Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.Makes : Tata, SAIL, TISCO, IISCO, RINL, Jindal Steel and Power Ltd, JSW Steel Ltd or equivalent as approved
24Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note:Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately.In case the cement content in design mix is more than 110% of the specified minimum cement content,the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level upto floor V levelConcrete of M25 grade with minimum cement content of 330 kg /cum
25Providing, fabricating, supplying, and fixing of powder-coated/anodized aluminium sliding door system complete as per site condition and direction of EIC
26Providing and fixing approved quality chrome plated brass long body bib cock (wall-mounted tap) of 15 mm nominal bore, with foam flow / aerator arrangement, complete with all accessories such as wall flange, screws, nuts, washers, fittings, and connection to the existing pipe line, including cutting and making good the wall surface, testing for leakage, and commissioning complete as per direction of Engineer-in-Charge.Makes : Duravit, Kohler, Queo, Artize, Jaquar, Toto, Hindware, Cere, Roca, Kerovit or equivalent as approved
27Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.(Make – Apollo ,Jindal or equivalent approved by Engineer in Charge)
28Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.(Including Cornor Sheet for Locking of Both Vertical and Horizontal Sheet) (Make - Jindal,Tata, JSW and equivalent approved by Engineer in Charge)
29Providing and laying Polished Granite stone Counter in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black
30Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group CMake: Polycab, KEI, RR Kabel, Finolex, Havells
31Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( withoutindependent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.Group CMake: Polycab, KEI, RR Kabel, Finolex, Havells
32Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wireMake: Polycab, KEI, RR Kabel, Finolex, Havells
33Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wireMake: Polycab, KEI, RR Kabel, Finolex, Havells
34Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
35Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
36Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required.
37Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
38Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recessSupplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.Make: Schneider Electric, Legrand, Siemens, ABB, L&T
39Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
40LED Panel light 2x2 ft., (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)36 wattMake: Philips , Wipro, Crompton, Havells, Bajaj
41Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)Make: Atomberg, Havells, Crompton, Orient Electric, Usha
42Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole. Make: Schneider Electric, Legrand, Siemens, ABB, L&T
43Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple poleMake: Schneider Electric, Legrand, Siemens, ABB, L&T
44Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A TPNMake: Schneider Electric, Legrand, Siemens, ABB, L&T
45Supplying and fixing of surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required .(Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 12 way (4 + 36), Double doorMake: Schneider Electric, Legrand, Siemens, ABB, L&T
46Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required
47Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 20 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.Make: Schneider Electric, Legrand, Siemens, ABB, L&T
48Supplying following 1.1kV grade, heavy duty XLPE insulated PVC Sheathed Copper Conductor FRLS type armoured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel armouring (round or flat as mentioned) and with all components as mentioned in BOQ, specifications and schedule, complete etc. as required.4core, 25 sq.mm.Make: Polycab, KEI, RR Kabel, Finolex, Havells
49Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
50Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required4C X 25 sq. mmMake: Polycab, KEI, RR Kabel, Finolex, Havells
51Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant,wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, aircirculation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5-year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply: Electricalcable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature).1.5 TR with 5 Star BEE Rating Make: Daikin, Mitsubishi Electric, Carrier, Blue Star, Hitachi Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56654533
AUTHORITY Government Departments
TENDER VALUE 19.26 Lakhs
LAST DATE 11-08-2026
Authority
Authority Name Indian Council Of Agricultural Research
Work Description Tender for Aluminum Partition Work And Pre-Painted Profile Sheet Barricading For Store Area Including Painting, Electrical And Air Conditioning Works For Pmdk At Crc Lucknow
Basic Detail
Tender No PT/LT/04/BE
Bidding Type Tender
Location
City Lucknow
State Uttar Pradesh
Key Dates
Publish Date 24 Jul 2026
Submission Date 11 Aug 2026
Open Date 12 Aug 2026
Finance
Tender Value 19.26 Lakhs
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
BOQ_965667.xls
fb4ef3b1-06dd-4f42-8149-f932f1a386a8.html
Tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 11, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Aug 12, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_965667.xls

html

fb4ef3b1-06dd-4f42-8149-f932f1a386a8.html

pdf

Tender.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender