Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #56652635

Tender For special Repair To Area Drainage And Certain Revenue Work At Aizawl Mil Stn

Issued by Statutory Bodies & Commissions/Committees · Kolasib, Mizoram
Tender Value
43.20 Lakhs
Estimated cost
Bid Submission
15 Aug 2026
18 days left
EMD
86400
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kolasib → Mizoram
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for special Repair To Area Drainage And Certain Revenue Work At Aizawl Mil Stn

BOQ

Name of Work:- SPL REPAIR TO AREA DRAINAGE AND CERTAIN REVENUE WORK AT AIZAWL MIL STN
Sl. No. Item Description
1B & R Division Items
2Demolition of un-reinforced cement concrete in ground floor and paving not exceeding 15 cm thick (below or above ground level) complete all as specified and directed.
3Demolition of Concrete of any description and in any position not otherwise specifically provided complete all as specified and directed.
4Demolition of reinforced cement concrete of any description and in any position complete all as specified and directed.
5Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and as directed.
6Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing) removing serviceable tiles to stores and rubbish off the premises.
7Dismantling plain or corrugated steel sheeting, any gauge or any thickness as in roof covering, wall cladding, etc.including all necessary staging / scaffolding, etc. as required complete all as specified and as directed.
8Dismantling wall and ceiling boards (fibre, pulb, insulation etc) or insulation boards slabs/blankets any thickness including cover fillets all as specified and as directed.
9Dismantling of timber scantling 40 Sqcm and over in section, in any position in framed work complete all as specified and directed.
10Taking down chowkhats or frame with shutters (without taking off shutters from frame) each not exceeding 1.50 Sqm each complete all as specified.
11Taking down Chowkhats or frames with shutters exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutters from the frame) complete all as specified.
12Taking up or down 15mm dia GI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
13Taking up or down 20mm dia GI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
14Surface dressing n exc 15 cm deep and getting out in soft / lose soil complete all as specified
15Excavation over areas not exceeding 1.5m deep and getting out hard/dense type of soil complete all as specified and directed.
16Excavating in trenches, n exc 1.50 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out hard/dense type of soil complete all as specified and directed.
17Excavating in trenches, n exc 1.50 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/ loose type of soil complete all as specified and directed.
18Returning, filling in trenches including spreading, leveling watering and ramming in layers not exceeding 25cm all as specified.
19Removing of surplus soil not exceeding 50 m and deposited where directed at a level not exceeding 1.50m above the starting point all as specified.
20Removing excavated materials (soils) exc. 1.50Km but n exc 5.0 Km and deposited where directed at a level not exceeding 1.50m above the starting point all as specified and directed.
21Removing building materials including debris etc. (other than spoil payable under items 03028 to 03031 in Section-3-Earthwork) to a distance beyond intitial 50 meter and up to 3 Km from unit location or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination,
22M & L for Hand packing of stone boulders (any thickness) at back of walls over arches etc. and raising (or lowering) to the required level complete all as specified and directed.
23M & L for Hardcore broken stone of gauge exc 40mm and n exc 63mm deposited spread and levelled in layers n exc 15cm thick watered and rammed to a true surface complete all as specified and directed.
24M & L for Plain cement concrete (1:4:8), Type D2 using 40 mm graded stone aggregate as in foundations, sub-base,filling and mass concrete complete all as specified.
25M & L for 100 mm thick plain cement concrete (1:4:8) type D-2 using (40mm graded stone aggregate) as in Sub base of floor rough surface complete all as specified.
26M & L for 75 mm thick plain cement concrete (1:4:8) type D-2 using (40mm graded stone aggregate) as in Sub base of floor rough surface for receiving tile complete all as specified.
27M & L for plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregates) as in plinth protection 75mm thick finished over and smooth without using extra cement complete all as specified and dirceted
28M & L for plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregates) as in foundations, sub-base,filling and mass concrete complete all as specified and dirceted
29M & L for plain cement concrete (1:2:4) type B1 using 20mm graded aggreagate as in surface channel and drain complete all as specified and directed.
30Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends for etc complete all as specified and directed.
31M & L for plain cement concrete (1:2:4) type B1 using 20mm graded aggreagate as in walls or retaining wall, any thickness, size or shape including plaster, buttresses columns, pillars, boundary pillars and posts ( including caps and bases) complete all as specified and directed.
32M & L for plain cement concrete (1:2:4) type B1 using 20mm graded aggreagate as in bed blocks, coping , cills, steps, kneelers, bed plates, apex stones kerbs and similar works including necessary formwork complete all as specified and directed.
33M & L for Precast reinforcement cement concrete (1:2:4) type B1 using 20mm graded aggreagate as in cover slab for man holes, chullah hoods, chajja, water troughts, mangers, shelves and similar article with plain faces set in cement mortar (1:4) incl necessary formwork complete all as specified and directed.
34M & L for 25mm thick plain cement concrete (1:2:4) type B-0 using (12.50mm graded stone aggregate) as in floors complete all as specified.
35M & L for plain cement concrete (1:2:4) type B-0 using (12.50mm graded stone aggregate) as in kerbs or mud stops, rounded or chamfered on edges complete all as specified.
36Use and waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished flat surfaces of concrete complete all as specified and as directed.
37Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished flat surfaces of concrete all as specified and directed.
38Use and waste formwork to sides and soffits of floor or roof beam, beam hunching, girder, lintels, cantilever, shelves including supports etc for rough finished flat surfaces of concrete complete all as specified and directed
39Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed
40Use and waste of formwork to faces of wall, retaining walls, abutments, parapets and staircase railings and similar work including attached pilasters, buttressws etc vertical or to batter all as specified and directed.
41M & L for Reinforced Cement Concrete nominal mix 1:1.5:3 type A1 using 20 mm graded aggregate a in foundation including rafts, footings, foundation beams, plinth beams, bases for columns etc complete all as specified and directed.
42M & L for Reinforced Cement Concrete nominal mix 1:1.5:3 type A1 using 20 mm graded aggregate as in columns, pillars, piers, posts and struts complete all as specified and directed.
43M & L for Reinforced Cement Concrete nominal mix 1:1.5:3 type A1 using 20 mm graded aggregate as in beams, cantilever, lintels over 1.5 m complete all as specified and directed.
44M & L for Reinforced Cement Concrete nominal mix 1:1.5:3 type A1 using 20mm aggregate as in slab supported on walls , beams, and column in floors, roof, landing, balconies, canopies, deck slab and in shelves and like etc comlpete all as specified and directed.
45M & L for Mild Steel TMT Bar 10mm dia and over , cut to length bend to shape as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
46M & L for Mild Steel TMT Bar 6mm dia and over up to 10 mm dia as in stirrups, spacers and binders as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed
47M & L for Walling of random rubble ,coursed in retainning walls,abutments and similar works regular coursed,well bonded,bedded and solidly hearted,built in cement mortar(1:6) with lime/sand stone and Precast Cement concrete (1:3:6) type C1 as bond stone (in lieu of stone bond stone ) set in cement mortar (1:6) brought upto courses Complete all as specified and directed Note :- (i) Precast PCC Bond stone shall be measured and paid separately relevant against Item.(ii) RR Masonary will be measured after deducting qty of PCC Bond stone.
48M & L for precast PCC bond stone (1:3:6) type C1 using 20 mm graded stone aggregates) as bond stone use for retainning wall, abutment and similar works and set in cement mortar 1:6 including neceessary formwork Complete all as specified and directed
49M & L for raised pointing to squared rubble, coursed or uncoursed in CM (1:3) complete all as specified and directed
50M & L for precast autoclaved acrated concrete bricks (AAC) block masonary with 150mm thick with grade -I, AAC block of density 551 to 650kg/cum conformimg to IS-2185 (Part -III) i super structure above plinth level upto floor V level with RCC bend at sill level and lintel level with approved block laying polymer modified adhesive mortar complete all as spd and directed. Note : RCC bend and reinforcement shall be measured and paid separately
51M & L for brickwork with subclass 'B' old bricks straight or curved on plan exc 6 m mean raduis, built in CM (1:6) complete all as specified and directed.
52M & L for 15 mm thick rendering on fair faces of concrete surface in cement mortar (1:3) surfaces finished even and smooth with additional thickness to be provided as floating/setting coat using extra cement complete all as specified and directed.
53M & L for 15 mm thick rendering in cement mortar 1:6 on fair faces of brick wall or concrete surfaces, finished the surfaces even and fair without using extra cement complete all as specified and directed.
54M & L for 15 mm thick rendering in cement mortar 1:4 on fair faces of brick wall or concrete surfaces, finished the surfaces even and fair without using extra cement complete all as specified.
55Supply only integral water proffing compound WPC complete all as specified.
56M & L Non Skid ceramic tiles colour 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.06 but not exceeding 0.11 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including 15 mm thick screed bed or bedding layers in cement mortar 1:6 over brushing with neat cement slurry complete all as specified.
57M & L Glazed ceramic coloured tiles in vertical surface size 450mm x 300mm x & ( 6mm to 7mm )mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over & including 10mm thick screed bed or backing coat in cement mortar 1:4 laying of skirting/dado on walls all as specified and directed.
58M & L for 20mm thick granite stone slab, of any type, table rubbed and polished, in steps, jambs, pillars, window cills, cooking platforms and the like in laid over and including 15mm thick screed in cement mortar (1:6) with cement slurry @4 kg/Sqm including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of slab and taking off old damaged slab and disposing off complete all as specified and as directed.
59S & F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
60S & F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
61S & F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers,hold fasts, bands, straps, wall ties, plain angle cleats, eaves board frame and similar articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
62S & F mild steel screw bolts (machine made) of 11 mm to 15 mm dia with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,length of bolt exceeding 10 cm but not exceeding 15 cm complete all as specified.
63S & F 5 mm thick mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to Fe 290 grade E-165 complete all as specified.
64S & F structural steel work in tubular/hollow sections trusses , Purlin , posts, rafter etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 complete all as as specified and directed.
65S & F 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type with decorative faces veeners on both side all as specified and directed.
66S & F 2nd class hard wood glazed and skeleton door shutters 35 mm thick open rebated and prepared to receive glass, guage etc (with sash bars), edge of framing plain chemfered ro rounded fitted with cut and mitred beds for securing glass etc complete all as specified and directed.
67S & F Solid PVC door frame of size 50mm X 47mm made out of 5 mm wood grain printed PVC sheet reinforced with mild steel square tube and edges will be painted to match with printed sheet complete all as specified in clause 8B.3.1 and shown on page 150 of MES Schedule Part-II (2010).
68S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded wood grain printed plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and wood grain printed PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of wood grain printed sheet, 15mm wide x 5mm thick PVC sheet beading used inside stiles and rail and decorative PVC beading of 10mm x 10mm (90 degree), used solvent cement, S & Fing in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2004) complete all as specified. Make: Rajshri or equivalent as approved.
69S & F Pressed steel frames made of 1.25mm thick MS sheet of profile 165mmX60mm for door and window frames with one or more rebates including hinges, lock strike plate, shock absorber, treating of internal surfaces of chowkhats with coal tar or black paint including hinges, hold fasts/lugs etc complete all as specified.
70S & F Steel ventilator with top hung shutter including hinges, steel peg stay, lugs as in hold fast with locking arrangements, complete all as specified.
71S & F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified.
72S & F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z-sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge
73S & F 3.00mm thick sheet glass ordinary quality and glazing with oil putting square n exc 0.5 sqm in each pane complete all as specified.
74S & F 75mm long MS Butt hinges, medium weight, cold rolled complete all as specified.
75S & F 150 mm long extruded aluminium alloy handles fabricated type anodised complete all as specified & directed .
76S & F 150 mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and directed.
77S & F 200 mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and directed.
78S & F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixedcomplete all as specified.
79S & F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixedcomplete all as specified.
80S & F 150 mm length floor door stopper of brass body and tongue, anodised with hard drawn steel spring, fixed in floor, overall length cover plate 150mm, etc complete all as specified & directed .
81S & F as MS chromium plated curtain rods with brackets including fixing stops, rollers bracket etc with harrison rails all as specified and directed .
82S & F for vitreous china wash basin, Wall hung basin with fixing accessories set, size 560mm X 430mm X 195mm, set with full pedestal complete all as specified. Make- Jaquar CNS-WHT-811 and CNS-WHT-303 or equivalent as per approved list
83S & F in repair vitreous china Squatting pan, 'Orissa' pattern, Size 580 X 440mm ,with integral foot rests (excluding flushing ciestern and flush pipe) incl provision of cement concrete bedding complete all as specified & as directed .
84S & F PVC valveless, syphonic action type, low level flushing cistren 10 ltr capacity ISI Marked incl all acessories and 32mm dia PVC flush / discharge pipe incl float valve, inlet complete all as specified.
85S & F soap dish chromium plated standerd quality fixed on wall with brass screw complete all as specified.
86S & F PVC connections 15mm size with PTMT nuts of length 450 m complete all as specified.
87S & F PVC connections 15mm dia size with PTMT nuts of length 600mm complete in all respect as specified
88S & F 15mm bore pillar tap cast copper alloy with capstan head, chromium plated concealed screwed down high pressure with or without hot or cold with long shunk screwed shanks and fly nuts screwed for iron pipes and connecting to water pipe line complete all specified and directed.
89Supply and fix as 15 mm bore bib taps fancy type, chromium plated, cast copper alloy with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule all as specified.
90S & F Chromium plated shower roses with or without swivel joints of any colour for fixing with 15mm pipe. ( Minimum weight 40gms ) with shower arm 15mm size. 195mm long with bend of 45 degree with flange of PTMT any colour. (Minimum weight 40gms) complete in all respect as specified.
91S & F sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60cm long fixed in position with CP screw complete all as specified and directed.
92S & F 600mm X 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed.
93S & F Towel rail, 20mm dia brass chromium plated, 600mm long with fancy type brass chromium plated brackets on both sides and fixed with steel screws and wooden/rawl plugs complete all as specified.
94S & F 32mm bore low density polyethylene pipes (LDPE) of pressure rating 6kgf/sqcm fixed complete all as specified and as directed.
95S & F in repair water connection for Hot & Cold water connection pipe for geyser of any capacity, steel armared of length not less than 600mm complete all as specified and directed.
96Supply and fix eaves gutters 110 mm bore PVC (SWR) Pipe single socketed in any length with rubber ring joints, fixed in wall complete all as specified.
97S & F 110mm bore PVC (SWR) pipes single socketed with rubber joint, in any length, with rubber ring joints, laid in trenches or in floors complete all as specified.
98S & F 75mm bore PVC (SWR) pipes single socketed with rubber joint, in any length fixed to walls / floors or in trenches complete all as specified.
99S & F 50mm bore PVC (SWR) pipes single socketed with rubber joint, in any length, laid in trenches or in floors / fixed to walls complete all as specified.
100S & F 110mm bore PVC (SWR) bend suitable for pipe complete all as specified.
101S & F 75mm bore PVC (SWR) cowls pipe complete all as specified.
102S & F 110mm bore PVC (SWR) junction, single T equal or unequal with or without door access complete all as specified.
103M & L PVC(SWR) floor trap, 75mm bore , plain with grating including jointing with solvent cement complete all as specified.
104S & F 110mm dia PVC (SWR) reducer suitable for pipe complete all as specified.
105S & F 110mm dia PVC (SWR) WC connector with lip ring suitable for pipe complete all as specified.
106S & F 110mm dia PVC (SWR) 'S' trap suitable for pipe complete all as specified.
107S & F 15mm bore steel water tubing, medium grade, galvanised with screwed and socketed joints, in any length, including S & Fing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for water connections complete all as specified and as directed.
108S & F 20mm bore steel water tubing, medium grade, galvanised with screwed and socketed joints, in any length, including S & Fing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for water connections complete all as specified and as directed.
109S & F 20 mm bore dia, Gun-metal, gate valves, with iron wheel head, screwed both ends on GI pipes with GI union fixed in existing/ new location complete all as specified and directed.
110S & F 15mm bore stop angle valve chromimum plated, any colour high pressure screwed for iron pipe and fixed, ( Minimum weight 15mm-90gms) and fixed complete all as specified.
111M & L for suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system) of grid size 600mmx600mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 4mm thick high Pressure high pressure Non Asbestos Fiber Cement decorative Board (E-Board Classic) in a grid of GI system duly suspended with 4 mm dia GI bar hanger fixed with steel dash fasteners or iron purline from the roof with adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts, sprinkler, smoke detectors etc. The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. The last hanger at the end of each main runner should not be placed at more than 450mm from the adjucent wall, flush fiiting 1220mm cross tee to be interlocked between main runners @ 610mm c/c, as to form 600 mm x 600 mm grid and incl apply coloured painting work with two coat of acrylic emulsion paint over a coat of cement primer before installing it on the grid all as specified and directed. Make : Everest Industries Ltd or equivalent as per IS 14862 all as specified and directed.
112M & L for preparation of new plastered surface surfaces of walls and applying three coats of white wash complete all as specified and directed.
113M & L for applying two coats of cement base paint over one coat of primer on plastered surfaces of walls including preparation of new or previously untreated surfaces all as specified and directed
114M & L preparation of new plastered surface of walls and applying two coat of acrylic distemper over one coat of alkali resistant primer complete all as specified.
115M & L preparation of new steel surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
116E & M Division items
117Taking down carefully copper/aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc including removing from site for taking credit and making good to disturbed surface of walls, floors etc as per existing specification complete all as specified and as directed.
118Taking down old existing light fitting any type and any capacity complete all as specified and as directed.
119M & L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty,concealed PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One light point controlled by one switch.
120M & L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty,concealed PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for ceiling fan point controlled by one switch.
121M & L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, concealed PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One fan point/exhaust fan point controlled by one, one way switch .
122M & L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, concealed PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One 3 pin 5 Amp socket outlet point controlled by one switch on the same board.
123M & L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One 3 pin 5 Amp socket outlet point controlled by one switch on independent board.
124M & L for point wiring with FRLSH stranded copper conductor 2.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 2.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for 3 pin, 15 Amp socket outlet, independent
125M & L for point wiring with FRLSH stranded copper conductor 4.0 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, concealed PVC Conduit concealed type of suitable size including all accessories etc ISI marked, with GI sheet pressed terminal box (recessed) with 3mm thick laminated hylem sheet top cover for fixing switches, sockets and regulators including PVC insulated FRLSH stranded copper conductor 4.0 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for 3 pin, 15 Amp socket outlet, independent.Note: The point wiring will be done from DBs to the switch sockets of any size with three wires running independently for each point and with no tappings.
126S & F modular switch 1 way 6A/10A, 1 Module complete all as specified and directed.
127S & F modular switch 1 way 16A/20A, 1 Module complete all as specified and directed.
128S & F modular socket 6A/10A, 2/3 pin combined 2 module complete all as specified and directed.
129S & F modular socket 16A/20A, 2/3 pin combined 2 module complete all as specified and directed.
130S & F ceiling rose surface bakelite with three terminals all as specified and directed
131S & F modular metal flush box 3 module with white cover plate with frame ISI marked complete all as specified and directed
132S & F modular metal flush box 6 module with white cover plate with frame ISI marked complete all as specified and directed
133Supply & Fix LED betten tube light fitting of capacity 20W, extruded aluminum housing enhances safety, high quality PC diffuser, easy to install efficiancy 110/125lumen/watts operating on 230V, 50Hz, AC Supply, CCT 6500K, P.F>0.9, 2.5 KV surge protection, 4-feet long, housing made out of extruded alluminium with decorative end caps elegently designed complete all as specified.
134Supply & Fix LED betten tube light fitting of capacity 20W, aluminum housing enhances safety, high quality PC diffuser, easy to install efficiancy 110/125lumen/watts complete all as specified.
135Supply & Fix enviromental friendly bldg security street light, LED luminaire 25 watt made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07 including fixing arrangements complete all as per directed by Engr-in–charge.
136S & F for Plastic body Exhaust Fan 250 mm sweep, single phase 230 volts AC, 900 RPM four blade with louver shutters complete fixed properly on wall surface with the provisioning of suitable sizes of rag bolts, nuts, washer and to connect by using cable PVC insulated copper stranded conductor of size 1.5 Sqmm 3 core and overall PVC sheathed which shall be passed through PVC flexible conduit of length not exceeding 0.50 mtr all as reqd and as directed by Engr-in-Charge.
137S & F BLDC ceiling fan 1200mm sweep complete with blades, down rods and accessories, 230 V, min air delivery 210 CFM with service value 6.00 BEE 5 star rated & provn of ‘S’ type fan hook complete all as specified and directed.
138S & F electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection pipe etc complete all as specified and as directed.
139S & F sheet metal enclosure powder coated single phase DB for fixing of MCBs, 8 way double door with Aluminum bus bar 100 Amp including grouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed.
140S & F MCB SPN of capacity 6-32 Amps, 240 V, 10 KA 'C' curve complete all as specified and directed.
141S & F MCB SP of capacity 5-32 Amps, 240 V, 10 KA 'C' curve complete all as specified and directed.
142S & F MCB SP of capacity 5-32 Amps, 240 V, 10 KA 'B' curve complete all as specified and directed.
143Taking out old existing earthing and M & L for new earthing with galvanised steel earth plate electrode 600mm X 600mm X 6mm thick burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to 4mm dia GI wire protected by 20 mm bore light grade galvanised iron pipe and other end connected to test point as directed including funnel with wire mesh and watering pipe 20 mm bore medium grade galvanised iron pipe with charcoal and common salt in alternaterlayers of 15 cm thickness all around the GI plate electrode with concrete pit in PCC 1:3:6 type C-1 with cast iron frame including cast iron cover 10mm thick hinged to CI frame and 6mm MS rod for handle, necessary excavation and earth wok in hard/dense soil and disposal of spoil to a distance n exc 50 m and necessary testing complete all as shown in electrical plate No 3 of SSR part-I complete all as specified and directed.
144Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 6sqmm 2 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56652635
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 43.20 Lakhs
LAST DATE 15-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repair To Area Drainage And Certain Revenue Work At Aizawl Mil Stn
Basic Detail
Tender No 8174A/E8
Bidding Type Tender
Location
City Kolasib
State Mizoram
Key Dates
Publish Date 25 Jul 2026
Submission Date 15 Aug 2026
Open Date 18 Aug 2026
Finance
Tender Value 43.20 Lakhs
Tender Fee 500
EMD 86400
Exemption Available
Document List
8174A-SchofCreditformat.pdf
8174A-TP.pdf
a3a17550-28c4-41a5-a012-39f1d0df5874.html
BOQ_874588.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 25, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Aug 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
pdf

8174A-SchofCreditformat.pdf

pdf

8174A-TP.pdf

html

a3a17550-28c4-41a5-a012-39f1d0df5874.html

xls

BOQ_874588.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders