Defence Statutory Bodies & Commissions/Committees Closing in 21 days TDR #56652619

Tender For Repair/Maint Of Centrifugal Pump Set Lt Panel Soft Starter Panel At Water Supply Installation Under Age(I) Lansdowne

Issued by Statutory Bodies & Commissions/Committees · Pauri Garhwal, Uttarakhand
Tender Value
14.95 Lakhs
Estimated cost
Bid Submission
19 Aug 2026
21 days left
EMD
29900
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pauri Garhwal → Uttarakhand
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maint Of Centrifugal Pump Set Lt Panel Soft Starter Panel At Water Supply Installation Under Age(I) Lansdowne

BOQ

Name of Work:- REPAIR/MAINT OF CENTRIFUGAL PUMP SET LT PANEL SOFT STARTER PANEL AT WATER SUPPLY INSTALLATION UNDER AGE(I) LANSDOWNE
Sl. No. Item Description
1Excavation in trenches in any type of soil n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth for foundation laying of pipe etc n.exc 10 sqm on plan and n.exc 1.5 mtr in depth and getting out complete all as specified and as directed.
2Returning filling in including spreading levelling watering and well ramming in layers not.exc 25cm each layers complete all as specified and as directed.
3Removing excavated material(soil) n.exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed.
4S & F GI tubing, \\"medium grade\\" (ISI Marked) 100 mm dia with screwed joints or welded joints all as per site requirement incl all fittings complete laid in trenches / on walls / on ceiling / roof etc incl necessary suitable size of MS clamps / saddling on walls / ceiling etc including taking down old GI tubing complete all as specified and directed at water supply distribution/pumping system Lansdowne .
5Disconnecting /Dismantling all connections and taking out old Pebbles/granulars etc and S&F activated carbon & filtration media for Model No - MCF 1400, Dia - 1400mm , Height-1875mm of following type and size:
61.Vessel Size- 18*75
7a. Gravels Media - 300 Kg.
8b. Activated Carbon Media 800 IV - 900 Kg.
92. Multigrade filter, Model-MGF-1400 DIA
10Vessel Size- 18*75
11a. Gravel Sand Media- 300 Kg.
12b. Core Sand Media - 400 Kg.
13c. Fine Sand Media -700 Kg.
143. Vacating, Filling & service charges -1 Job
15S&F in repair of MCCB 4 pole, 415 volt , adjustable thermal and magnetic release type 400 Amp breaking capacity 36 KA complete all as specified and directed.
16S&F in repair of MCCB 4 pole, 415 volt , adjustable thermal and magnetic release type 250 Amp breaking capacity 36 KA complete all as specified and directed.
17S&F in repair of MCCB 4 pole, 415 volt , adjustable thermal and magnetic release type 350 Amp breaking capacity 36 KA complete all as specified and directed.
18S&F in replair of MCCB 4 pole, 415 volt , adjustable thermal and magnetic release type 160 Amp breaking capacity 36 KA complete all as specified and directed.
19Supply, installing, testing and commissioning in repair factory made and tested Indoor type Phase Sequence Corrector of capacity 200 Amps , 3 Phase 4 Wire, 415 volts, 50 Hz, wall mounted. The Phase Sequence Corrector shall be dust and vermin proof, protection class (IP-42) and made of 2.00 mm thick CRCA mild steel sheet, front opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FR cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anti corrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey shade 7035. The scope of work also comprising of the following:-
201. Motor Protection Automation Phase Sequence Corrector single phase preventer with facility to change over from automatic to manual with Over Load protection for contactors upto 200 Amps motor etc Protection :- Avoid damages during Phase sequence changes or reversal.• The Sequence Corrector will switch off, during the Single Phasing or Imbalance voltage occur & later, Auto-reset after restoration.• Quartz Timer One dial daily for automatic operation of motor.• No break downs of Three phase system due to the change in sequence.• Bye Pass Selector switch in case of controller Faulty.• Surge Protection Device 3 Phase 40kA 240/415 V AC= 01 No.The panel manufacturer should have following Govt. Approved Certificates: 1. CPRI Certification Degree of Protection IP-422. CPRI Certification Short Circuit withstand strenght should be 50kArms for 1.0 Sec 3. CPRI Certification Rated current for short circuit not less than 4000A with rated insulation voltage 660V4. ISO 9001 CERTIFIED
21Supply & fix in repair enclosed automatic star delta Starter suitable for 75 HP which is the combination of 3TF Contactors, 3UA relay and 3RP Timer with no derating upto +55°C, provides overload, single phasing protection for three phase motors and IP54 for Enclosure complete all as specified and directed.1. Operating Voltage ‒ 415V ac2. Rated Insulation Voltage ‒ Main circuit : 690V Auxiliary circuit : 690V3. Rated Impulse Voltage ‒ Main circuit : 8kV Auxiliary circuit : 6kV4. Coil Voltage ‒ 415V ac5. Permissible ambient temperature ‒ Operation : -5 to 40 °C,Temperature compensation : Upto 40 °C6. Frequency ‒ 50 Hz7. IP Protection ‒ IP 548. Cable incoming from Supply ‒ Top & Bottom both provisions9. Cable outgoing to Motor ‒ Bottom10. Locking ‒ Middle lock with key
22Taking down non functional electric induction motor of any size and capacity from water supply installation at 3rd stage/ Jharapani/ 2nd lift/ 15 Lakh GLN pump house, decoupling motor from pump and cutting, removing burnt out copper winding and re-winding with super enamelled copper wire of suitable gauge conforming to IS 13730-0-6 (2012) and reassembling /couple back complete and transporting back to its original location and making necessary alignment and electric connection complete all as specified and directed. Note :- Any other spare parts, if needed to be replaced shall be measured & paid as supply only separately under respective item of Sch 'A'/ BOQ.
23Supply only following spare parts suitable for motor mentioned at item No 12 above complete all as specified and directed :-
24Stainless steel bush/shaft sleeve for suction/delivery for 75 HP centrifugal multistage horizontal pump with bore as per sample.
25Stainless steel bush/shaft sleeve for suction/delivery for 100 HP centrifugal multistage horizontal pump with bore as per sample.
26Cast steel bearing lock nut with washer as per sample for 100HP Pump.
27Roller bearing NU-207 for 100HP Pump.
28Bush type flexible cast iron flanged coupling with finished bore and keyway as per sample for centrifugal Pump set.
29Rubber bush along with pin (high tensile nut bolt) as per sample for flexible coupling.
30S&F in repair electronic star delta timer 3-30 seconds type ST100,160-500Volts, 50Hz complete all as specified and directed.
31S&F in repair Power Contactor 95 Amps complete all as specified and directed.
32S&F in repair auxiliary contact block side mounting with 1 No + 1 NC complete all as specified and directed.
33S&F in repair motor protection relay D2MPR complete all as specified and directed.
34S&F in repair Phase failure relay with under and over voltage settings complete all as specified and directed.
35Supply and installation of solar all-in-one street lighting with smart intergrated solar street light with built in mono crystalline Solar Panle, lithium Feero phospate (LiFeP04) battery, MPPT charge controller and PIR Sensor with color temperature range 6000-6500K of power rating 25 watt, panel capacity 45W and battery capacity 21 AH with autonomy for 03 days complete with 5-6mtr hot dip galvanized octagonal smart pole duly grouted in PCC 1:2:4 (nominal mix) type B2 (Using 40mm graded crushed stone aggregate) as in foundation and all other works as required at site during execution as per manufacturer's recommendation, complete all as specifed and directed.
36Supply only calcium Hypochlorite Granules (65%-70%) complete all as specified and directed.
37M&L for brick work with sub class 'B' old size bricks straight or curved on plan exc 6.00 m mean radius built in cement mortar 1:6 for Pipe Line Support complete all as specified and directed.
38M&L for rendering 10 mm thick in cement mortar 1:6 on external surfaces of brick wall/concrete surface finished even anf fair complete all as specified and directed.
39M & L for angle iron work for support of water pipeline by welding at scattered location complete all as specified and directed.
40S& F in replacement soft starter suitable for 110 KW(150 HP) 3 phase 135 Amp as per existing at site complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56652619
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 14.95 Lakhs
LAST DATE 19-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint Of Centrifugal Pump Set Lt Panel Soft Starter Panel At Water Supply Installation Under Age(I) Lansdowne
Basic Detail
Tender No 87327/LDN/E8
Bidding Type Tender
Location
City Pauri Garhwal
State Uttarakhand
Key Dates
Publish Date 24 Jul 2026
Submission Date 19 Aug 2026
Open Date 28 Aug 2026
Finance
Tender Value 14.95 Lakhs
Tender Fee 500
EMD 29900
Exemption Available
Document List
BOQ_874451.xls
ff3b99e1-6a96-41b3-a2cf-17e747116b42.html
Tender87327.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 21 days
Aug 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 30 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_874451.xls

html

ff3b99e1-6a96-41b3-a2cf-17e747116b42.html

pdf

Tender87327.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders