Tender For Provisioin Of Incinerators, Replacement Of Water Tank, Acs And Coolers At Icgas Chennai Under Ge (I) Cg Chennai
Tender Value
58400
Estimated cost
Bid Submission
14 Aug 2026
0 days left
EMD
58400
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provisioin Of Incinerators, Replacement Of Water Tank, Acs And Coolers At Icgas Chennai Under Ge (I) Cg Chennai
BOQ
| Sl. No. | Item Description |
| 1 | Supply and Fix Rotational Moulded Polyethylene (HDPE) FDA grade materials water storage tanks,1000 litres capacity, three layered (Cylindrical vertical with closed top) screwed lid type conforming to IS 12701-1996 with manhole lid and suitable locking arrangement, making holes for inlet, outlet, washout and over flow pipes, hoisted and fixed in position as specified in SSR Part -I (2009) complete all as specified and as directed. |
| 2 | Taking down 25mm dia steel tubing including all connections and fittings complete all as specified and as directed by the Engineer-in-Charge. |
| 3 | Taking down 20mm dia steel tubing including all connections and fittings complete all as specified and as directed by the Engineer-in-Charge. |
| 4 | Supply and fix of 20mm bore dia Medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors etc., complete all as specified and as directed. |
| 5 | Supply and fix of 25mm bore dia Medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors etc., complete all as specified and as directed. |
| 6 | Supply and Fix in repairs Gun metal globe or gate valve of size 25mm bore confirming to IS 778-1984 with brass spindle and iron wheel head at the top screwed both ends for GI pipe including all fittings / fixtures like nipple, union etc., complete all as specified and as directed. |
| 7 | Supply and fix in repairs Ball brass valve (Float valve for water tanks) 25mm dia high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrute and fixed complete all as specified and as directed. |
| 8 | Excavating in trenches not exceeding 1.5m wide and not exceeding1.5m in depth for foundationetc for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed. |
| 9 | Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out a in soft/loose soil complete all as specified and as directed. |
| 10 | Material and Labour for Plain cement concrete 1:4:8, type D2 using 40 mm graded stone aggregate as in foundation filling as mass concrete complete all as specified and as directed. |
| 11 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and as directed. |
| 12 | Removing excavated material (soil) n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point complete all as specified and as directed. |
| 13 | Material and labour for Hardcore of gauge exc 63mm but not exceeding 100 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and as directed. |
| 14 | Material and labour for providing 100mm thick cement concrete type D-2, 1:4:8 (using 40mm graded crushed stone aggregate) as in sub base of floors complete all as specified and as directed. |
| 15 | Material and labour for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in radius, built in in cement mortar(1:6) old size bricks complete all as specified and as directed. |
| 16 | Material and labour for rendering in Cement Mortar 15mm thick in two coats, i.e, in Cement Mortar 1:4, 5mm thick mixed with water proofing compound as per manufacturers' instructions over in Cement Mortar 1:6, 10mm thick on fair faces of brick/concrete surfaces, finished even and fair externally all as specified and as directed.Note: WPC will be measured and paid separately. |
| 17 | Material and labour for applying two coats of cement base paint over a coat of primer on new plaster or untreated surfaces on walls incl preparation of wall complete all as specified and as directed. |
| 18 | Supply only integral water proofing compound. |
| 19 | Supply and fix of Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 20 | Demolition of Reinforced cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 21 | Material and Labour for Providing precast cement concrete of 1:2:4 Type B1 using 20mm graded stone aggregate as in cover slabs etc including making of perforated holes if necessary and set in cement mortor 1:6 including all mouldings but excluding frames complete all as specifed and as directed.Note: Reinforcement bars shall be measured and paid separately. |
| 22 | Material and labour for High strength Mild steel Deformed Steel Bars produced by Thermo Mechanical Treatment process [TMT] of grade Fe-500D in reinforcement, 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-500D complete all as specified and as directed. |
| 23 | Material and labour for preparation of new steel surfaces over 10cm in width or girth and applying two coats of synthetic enamel paint over one coat of zinc primer complete all as specified and as directed |
| 24 | Demolition of floor hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off the premises to out side MD land etc., complete all as specified and as directed. |
| 25 | Material and labour for Double charged Virified ceramic tiles of grade B-I(a), 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, laid in floors of pattern as approved over and including 15mm thick screed bed in Cement mortar 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. |
| 26 | Material and labour for Double charged Virified ceramic tiles of grade B-I(a),10 mm thick (square/ rectangular) polished, of size matching to floor tile as approved, fixed in vertical surfaces such as in skirting/dado set and jointed in neat cement slurry and pointed in white or coloured cement to match floor tile over a backing coat in Cement Mortar 1:4, 10mm thick on fair faces of brick or concrete surfaces complete all as specified and as directed. |
| 27 | Material and labour for coloured Vitrified Ceramic tiles of grade B-I (a),10 mm thick (square/ rectangular) polished, light shade, area of each tile not exceeding 0.36 sqm, laid in floors of pattern as approved over and including 15mm thick screed bed in Cement mortar 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and as directed. |
| 28 | Material and labour for coloured Vitrified ceramic tiles of grade B-I(a), 10mm thick of size matching to floor tile as approved by GE, fixed in vertical surfaces such as in skirting/dado set and jointed in neat cement slurry and pointed in white or coloured cement to match floor tile over a backing coat in Cement Mortar 1:4, 10mm thick on fair faces of brick or concrete surfaces all as specified and as directed. |
| 29 | Supply, install, test & commissioning of 2 TR Capacity Wall mounted Split Air conditioners, BEE 5 star rated with plasma filter and builtin air ionizer, EER 3.2 fitted with hermitically sealed compressor operating on refrigerant green gas non CFC fir wall mounting, copper cooling coil and conforming to IS 1391(Part 2) suitable to operate on 230±10%,50Hz single phase AC supply with evaporator and condensing unit made of copper tubes with aluminium fins, cordless remote control, copper piping for both suction and discharge of three meters length with protection covering for piping of suitable size of medium PVC pipe, power and control cabling as per site requirement, out door unit fitted with MS brackets including taking down BER ACs and out door units up to 2 TR capacity and along with all accessories like copper tupes etc., handover to MES store complete all as specified and as directed. |
| 30 | Note for item No.29[i] Contractor shall submit 5 Years warranty for Indoor unit, PCB, 10 Years warranty for compressor and 3 years warranty for Voltage stabilizer issued by the manufacturer / OEM to the Engineer-in-Charge.[ii] MS brackets for outdoor unit shall be measured and paid separately. |
| 31 | Supply, install, testing and commissioning of water cooler, fully stainless steel, electric driven single phase, 230 volt, AC 50HZ having storage capacity of 80 liters and nominal cooling capacity 40 ltrs per hours complete including provision of suitable fixing arrangements such as angle iron, nut, bolt etc., complete all as specified and as directed. |
| 32 | Material and labour for Providing and fixing metal-clad industrial type socket outlet with plug top and miniature circuit breaker (MCB), 20A, 240V, 50Hz, single phase, IP44 rated, complete with MS sheet metal enclosure box of adequate size, 35mm DIN rail, 20A SP MCB conforming to IS 60898, 20A 3-pin industrial socket outlet and matching plug top conforming to IS 4615, cable gland of suitable size, internal PVC insulated copper wiring tails of 4 sq.mm, all terminals, ferrules, earth continuity connection, fixing to wall with rawl plugs / anchor fasteners, testing and commissioning, including all sundries and incidentals complete as directed by the Engineer-in-Charge. |
| 33 | Material and labour for Providing and fixing power wiring from distribution board (DB) to metal-clad industrial socket outlet using 2 x 4 sq.mm + 1 x 4 sq.mm (3 core) FRLS PVC insulated copper conductor wires pulled through 25mm dia surface / recessed PVC rigid conduit, complete with conduit clips / saddles at 600mm spacing, bends, elbows, junction boxes, draw wire, fish tape, all conduit accessories, termination at both ends with lugs / ferrules, earth continuity, testing and commissioning, including all sundries and incidentals complete as directed by the Engineer-in-Charge. |
| 34 | Supplying and laying of CPVC pipes 25mm bore (outer diameter) SDR 11 conforming to IS 15778, including plain CPVC SDR 11 solvent cement jointed fittings, fixed on walls / ceiling with clamps / saddles or laid in floors in chase, complete with solvent cement, primer, clamps, supports, cutting, jointing, pressure testing and commissioning, all as specified and as directed by the Engineer-in-Charge. |
| 35 | Supplying and fixing CPVC ball valve of 25mm outer diameter SDR 11 with threaded / solvent cement ends conforming to IS 15778 / IS 9890 in CPVC pipeline including cutting the pipe, fitting and jointing with solvent cement and primer, testing at specified pressure, commissioning complete in all respects as per specifications and as directed by the Engineer-in-Charge. |
| 36 | Supply and fixing Brass Elbow 25 mm nominal bore suitable for 25 mm OD CPVC pipe, complete with all necessary fittings, jointing materials, cutting and making good connections, complete all as specified and directed. |
| 37 | Supply and fixing brass tee suitable for 25 mm outer dia CPVC pipe, conforming to relevant standards, complete with jointing materials, cutting and making good connections, complete all as specified and as directed by the Engineer-in-Charge. |
| 38 | Supply and fixing brass union suitable for 25 mm outer dia CPVC pipe, conforming to relevant standards, complete with all necessary jointing materials, including cutting, fitting and making good connections, complete all as specified and as directed by the Engineer-in-Charge. |
| 39 | Supply and fixing male brass threaded adaptor (MTA/MBTA) suitable for 25 mm outer dia CPVC pipe, comprising CPVC socket end and brass male threaded insert, conforming to relevant IS standards, complete with jointing materials, fixing, testing and making good connections, complete all as specified and as directed. |
| 40 | Supply and fixing wall mounted automatic voltage stabilizer 5 kVA capacity, single phase, suitable for operation on 230V, 50Hz AC supply and compatible with split/window air conditioners, having digital display, copper wound transformer, input voltage correction range approximately 170–270V, output regulation ±5%, thermal overload and short-circuit protection, housed in powder-coated MS enclosure, complete with mounting hardware, wiring connections, testing and commissioning, all as specified and as directed |
| 41 | Material and labour for providing, laying and fixing interconnecting control/power cable between indoor and outdoor units of air conditioner, comprising 4 core × 1.5 sq.mm FRLS copper conductor cable with earth continuity conductor, laid along refrigerant piping and secured inside approved PVC casing-capping/conduit as required, including all fixing accessories, terminations, testing and commissioning, complete all as specified and as directed. |
| 42 | Material and labour for providing and fixing additional refrigerant copper piping set for air conditioner, beyond the standard 3.0 metre length supplied with the unit, consisting of a pair of seamless annealed copper tubes of suitable sizes for liquid and suction lines, complete with closed-cell nitrile rubber insulation, saddles, clamps, supports, fittings, brazing/jointing, pressure testing, insulation of joints and commissioning, complete all as specified and as directed. |
| 43 | Material and labour for providing, laying and fixing 25 mm dia PVC condensate drain pipe for air conditioning units, including all necessary fittings such as bends, tees, couplers, solvent cement joints, clamps, saddles, supports and fixing accessories, laid to proper gradient for free flow of condensate water, complete all as specified and as directed. |
| 44 | Material and labour for providing and fixing MS wall/floor mounting brackets/stand for outdoor unit of air conditioner, fabricated from suitable size mild steel sections, hot-dip galvanised or epoxy powder coated for corrosion protection, including foundation bolts, anchor fasteners, anti-vibration rubber pads, clamps, supports, cutting, welding, drilling and fixing in position, complete all as specified and as directed. |
| 45 | Material and labour for carrying out minor civil works in connection with installation of air conditioning system, comprising core cutting through walls/slabs, cutting and making chases, making good disturbed surfaces, cement plastering, painting touch-up, sealing of openings and restoration of finishes to match existing work, complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedAug 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender