Tender For Special Repairs To Storage Shed No 13 At B Park Of Cafvd Khadki Under Ge (Central) Khadki
Tender Overview
Project Description
Tender for Special Repairs To Storage Shed No 13 At B Park Of Cafvd Khadki Under Ge (Central) Khadki
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 14-Aug-2026 | Date Corrigendum | Date | 03-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | B R POTION:- Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings/wall cladding etc complete all as specified and directed by Engr-in-Charge. |
| 2 | S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge. |
| 3 | S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in Ridge/guter /roof covering/cladding to wall, fixed with self tapping screws as specified etc complete all as specified and directed by Engr-in-Charge. |
| 4 | S & F Plain, galvanised, mild steel sheeting 1mm thick, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 etc complete all as specified and directed by Engr-in-Charge. |
| 5 | S & F 2mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc.complete all as specified and directed by Engr-in-Charge. |
| 6 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engr-in-Charge. |
| 7 | S&F for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats, gusset plates etc conforming to Fe 410 -W (Gde-E- 250) quality-A etc complete all as specified and directed by Engr-in-Charge. |
| 8 | S & F Framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hangingdoor fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to Fe 410 -W (Gde-E- 250) quality-A complete all as specified and directed by Engr-in-Charge. |
| 9 | S & F for 1.00mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc as per required at site complete all as specified and directed by Engr-in-Charge. |
| 10 | M & L for preparation of new or previously untreated steel surface of any description over 10cm in width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge. |
| 11 | M & L for preparation of old painted steel surface of any description, not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint complete all as specified and directed by Engr-in-Charge. |
| 12 | Demolition of cement Concrete of any description and in any position not otherwise specifically provided for etc complete all as specified and directed by Engr-in-Charge. |
| 13 | M & L Pavement quality concrete(PQC) of minimum 28 days field Flexural strength of 45Kg/ Sqcm or 4.5 Mpa, aggregate gradation as per Table 3 of IRC 15 2017, coarse aggregate of clean , hard strong, dense non-porous and durable pieces of crushed stone gravel, fine aggregates of clean natural sand crushed stone sand or combination of both using minimum 360 kg/cum of cement with non-circular virgin synthetic fibre of 12-18 mm length, specific gravity 1.34 to 1.39, UV stable, alkali resistant, with equivalent dia 15-40 micron, minimum melting temperature as 240°C and minimum tensile strength of 300 Mpa and at the rate as specified by the manufacturer. PQC laid, spread and compacted with slip-form paver of minimum 7.50 m width , including curing and tining by Texturing cum Curing Machine complete all as specified and directed. Required surface texturing to be done as specified in Clause, 10 1 14 and Tabl~ 9 of IRC' 15-2017 etc complete all as specified and directed by Engr-in-Charge. |
| 14 | Finishing surface of concrete roads, pavements, by brooming etc complete all as specified and directed by Engr-in-Charge. |
| 15 | M & L Forming Contraction (Dummy) joints 65mm deep x 10mm wide,filled with sealing compound, Grade 'B' complete all as specified and directed by Engr-in-Charge. |
| 16 | M & L Forming Construction joint 200mm deep x 10mm wide filled with sealing compound Grade 'B' complete all as specified and directed by Engr-in-Charge. |
| 17 | M & L for 200mm thich concrete slab for forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ complete all as specified and directed by Engr-in-Charge. |
| 18 | Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles and removing the debris outside the defence land complete all as specified and directed by Engr-in-Charge. |
| 19 | M & L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:4) etc complete all as specified and directed by Engr-in-Charge. |
| 20 | M & L for 15mm thick Rendering on brick /concrete or dubbed surface in CM 1:4 on wall with water profing compound finishing even & smooth without using extra cement and similar like at any height including necessary scaffolding , ladder & formwork including taking down cement plaster, raking out joints, hacking for key & scrubbing down with water and removing the debris outside defence land complete all as specified and directed by Engr-in-Charge. Note : water proofing compound shall be measured & paid separetely |
| 21 | M & L for 15mm thick Rendering on brick /concrete surface in CM 1:4 with water profing compound (Qty as per manufacturer instructions) finishing even & smooth without using extra cement and similar like etc complete all as specified and directed by Engr-in-Charge. (Note : water proofing compound shall be measured & paid separetely) |
| 22 | Supply only Liquid water proofing compound complete all as specified and directed by Engr-in-Charge. |
| 23 | M & L for preparing new plastered surface of walls and applying two coat of cement base paint over alkali resistant primer at any height including necessary scaffolding ladder etc complete all as specified and directed by Engr-in-Charge. |
| 24 | Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc 15cm thickness (below of above ground level) and removing the debris outside the defence land complete all as specified and directed by Engr-in-Charge. |
| 25 | M & L for plain cement concrete (1:3:6) type C-2, 75mm thick (using 40mm graded stone aggregate) finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 26 | S & F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories)complete all as specified and directed by Engr-in-Charge. |
| 27 | S & F 110mm bore PVC (SWR) bends any radius etc complete all as specified and directed by Engr-in-Charge. |
| 28 | EM PORTION:- Taking down carefully existing unserviceable aluminum / copper point wiring of any description & in any position with and including existing steel conduit / PVC Conduit / Casing caping fixed on surface/wall/angle/gardder and including all fitting, accessories & fixtures such as switches, ceiling roses, pendants, regulators, sockets, etc including sunken boxes/junction boxes and making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and directed by Engr-in-Charge |
| 29 | M&L for point wiring in PVC conduit of suitable size but not less than 20mm including all fittings such as elbow, bends, junction boxes, saddles, etc. on surface with and including ISI marked two runs of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) 1.5 sqmm nominal cross sectional area, 1100 volts grade and including one run of 1.5 sqmm (green colour) ISI marked PVC insulated unsheathed multistranded (FRLSH) copper conductor cable as earth wire to be terminated in and including PVC rectangular block of suitable size for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover for one light point or one fan point controlled by one switch including making good the disturbed wall and painting the same with matching to existing wall complete all as specified and directed by Engr-in-Charge |
| 30 | All as per Srl item No 2 above but light/fan/exhaust fan point controlled by one switch. |
| 31 | All as per Srl item No 2 above but 5 pin switch socket outlet 5 Amps on independent board controlled by one switch. |
| 32 | All as per Srl item No 2 above but 5 pin switch socket outlet 5 Amps on same board controlled by one switch. |
| 33 | All as per Srl item No 2 above but for for one 6 pin switch socket outlet 15 Amps/AC Point on independent board controlled by one switch in PVC conduit. |
| 34 | S& F for switch flush type, 5 Amps, single pole, one way , 230 volts AC circuit complete all as specified and directed by Engr-in-Charge. |
| 35 | S& F for socket outlet, five pin, 5 Amps, flush type, multipurpose, 230 volts AC circuit complete all as specified and directed by Engr-in-Charge. |
| 36 | S& F for switch flush type, 15 Amps, single pole, one way , 230 volts AC circuit complete all as specified and directed by Engr-in-Charge. |
| 37 | S& F for Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type , flush type, 230 volts AC circuit complete all as specified and directed by Engr-in-Charge. |
| 38 | S& Ffor ceiling rose PVC/polycarbonate, isolated body, three terminals, complete all as specified and directed by Engr-in-Charge.. |
| 39 | S&F in replacement Stepped type electronic fan regulator flush type suitable for ceiling fans, prewired 230 volts AC 50Hz supply 100Watt complete all as specified and directed by Engr-in-Charge. |
| 40 | Supply, fixing, connecting and testing in replacement Industrial Earth Plug & socket with sheet metal enclosure of IP44 rating electric driven single phase including MCB 'C' series SP 20 Amps and supplied with neutral links complete all as specified and directed by Engr-in-Charge. |
| 41 | Dismantling and Taking out old unserviceable copper/aluminium sub main wiring/Unarmoured cable (used as Sub main wiring) from any height of any Size and Core with all connecting accessories incld. conduit or casing caping and incld. making good to the disturbed wall and painting the same with matching paint as of existing wall incld material all as specified and directed by Engineer in charge. |
| 42 | M&L for Sub main wiring at any height with 2 single core PVC insulated, multi stranded copper conductor cable (FRLSH), unsheathed, 2.5 sqmm, 1100 volt grade conforming to IS drawn through and including New 20 mm PVC conduit and including one single core PVC insulated multi stranded unsheathed copper conductor cable, 2.5 sqmm,, FRLSH green in colour as continuous earth wire including all accessories and fixing arrengements, supporting clamps, bends, sockets and connecting items etc.complete all as specified and directed by Engr-in-Charge. |
| 43 | M&L for Sub main wiring at any height and surface with and including two single core PVC insulated multi stranded copper conductor cable, conforming to IS, FRLSH type, 4.0 Sqmm, 1100 volts grade, drawn through and including New PVC conduit 20 mm dia including connected accessories and one single core PVC insulated multi stranded unsheathed copper conductor cable, FRLSH type, 4.0 sqmm, 1100 Volts grade,,green in colour as earth contuinity wire complete all as specified and directed by Engr-in-Charge. |
| 44 | M&L for Sub main wiring at any height and surface with and including two single core PVC insulated multi stranded copper conductor cable, conforming to IS, FRLSH type, 6.0 Sqmm, 1100 volts grade, drawn through and including including New PVC conduit 20 mm dia connected accessories and one single core PVC insulated multi stranded unsheathed copper conductor cable, FRLSH type, 6.0 sqmm, 1100 Volts grade,,green in colour as earth contuinity wire complete all as specified and directed by Engr-in-Charge. |
| 45 | Dismantling and Taking down unserviceable existing light fittings of any size and capacity from any location/height after disconnecting of electrical connection complete including all connected accessories complete all as specified and directed by Engr-in-Charge. |
| 46 | S&F for CRCA housing box LED Type luminiare suitable for and including 2x20 W 4 feet long complete including tube rod & connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
| 47 | S&F for CRCA housing box LED Type luminiare suitable for and including 2x20 W 4 feet long complete including tube rod & connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 11 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender