Tender For Repair / Maintenance Of Internal Electrication Incl Fitting And Fixtures With Connected Items, Internal Wiring, Submain Wiring, Distribution Boards/ Mccbs/ Mcbs, Building Security Lights Etc Of Md Jcos/ Ors Accn In Me Line & Cod Lines Area
Tender Overview
Project Description
Tender for Repair / Maintenance Of Internal Electrication Incl Fitting And Fixtures With Connected Items, Internal Wiring, Submain Wiring, Distribution Boards/ Mccbs/ Mcbs, Building Security Lights Etc Of Md Jcos/ Ors Accn In Me Line & Cod Lines Area Under Ge (North) Delhi Cantt - 10
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 14-Aug-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 21-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully copper / aluminium point wiring (light / fan socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces to match with the existing all as specified and directed. |
| 2 | M&L for point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc and making good to the disturbed surfaces complete all as specified and directed for One light / bell / buzzer point controlled by one, one way switch 06 Amps. |
| 3 | All as per the description of srl item No 02 here-in-before but one fan point controlled by one, one way switch 06 Amps. |
| 4 | All as per the description of srl item No 02 here-in-before but one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch complete all as specified and as directed. . |
| 5 | All as per the description of srl item No 02 here-in-before but one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch complete all as specified and as directed. |
| 6 | All as per the description of srl item No 02 above but point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 2.5 Sq mm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed. |
| 7 | S&F switch piano flush type, 06 Amps, single pole, one way, 230 volts complete all as specified and as directed. |
| 8 | S&F switch piano type 2 way 5/6 Amp, 230 Volt, flush button single pole two way complete all as specified and directed by Engineer -in-Charge. |
| 9 | S&F switch piano flush type, 16 Amps, single pole, one way, 230 volts with switch frame complete all as specified and as directed. |
| 10 | S&F socket outlet 2 in 1, 5 pin, 06 Amps, flush type, 230 volts with socket frame complete all as specified and as directed. |
| 11 | S&F socket outlet 2 in 1, 3 pin, 06 Amps and 3 pin, 16 Amps, flush type, 230 volts with socket frame complete all as specified and as directed. |
| 12 | S&F ding dong bell, AC, 230 volts, single pole complete all as specified and as directed. |
| 13 | S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and as directed. |
| 14 | S&F ceiling rose, 6 Amps, 230 volts, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25mm size complete all as specified and as directed. |
| 15 | Material and labour for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of modular metal flush box, modular white cover plate with frame, blanking plate etc suitable for Mylinc / Coral / Sleek model accessories etc and making good to the disturbed surfaces complete all as specified and directed for one light point controlled by one, one way switch 06 Amps. |
| 16 | All as per the description of srl item No 15 here-in-before but one bell point controlled by one bell push switch 06 Amps. |
| 17 | All as per the description of srl item No 15 here-in-before but one ceiling / Exhaust fan point controlled by one, one way switch 06 Amps. |
| 18 | All as per the description of srl item No 15 here-in-before but one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch. |
| 19 | All as per the description of srl item No 15 here-in-before but one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch. |
| 20 | All as per the description of srl item No 15 above but point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 2.5 Sq mm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed. |
| 21 | Supply and fixing modular switch, 06 Amps, single pole, one way, 230 volts, one module and IP 20 protection complete all as specified & directed. |
| 22 | Supply and fixing modular bell push with indicator, 06 Amps, single pole, one way, 230 volts, complete all as specified & directed. |
| 23 | Supply and fixing modular switch, with indicator, 16 Amps, single pole, one way, 230 volts, one module complete all as specified & directed. |
| 24 | Supply and fixing modular socket outlet 05 Pin, 06 Amps, 02 module with shutter complete all as specified & directed. |
| 25 | Supply and fixing modular socket outlet 02 in 01, 03 pin, 06 Amps and 16 Amps, 02 module with shutter complete all as specified & directed. |
| 26 | Supply and fixing modular ceiling fan regulator, 02 module, AC, 230 volts, 120 watts, duly ISI marked complete all as specified & directed. Note : Make/Model for Srl Item 21 to 26 shall be as per existing at site. |
| 27 | Supply and fix lamp holder, PVC / Polycarbonate fancy type suitable for batten fitting including 9W LED bulb complete all as specified and as directed. |
| 28 | S&F surface mounting LED integrated aluminium housing batten with polycarbonate deffuser luminaire not less than 10 watt 2 feet fixture should have minimum efficiency at level >=120lumens/watt, life of fixture not less than 50K Hrs, Ripple<5%, UGR<19, Minimum surge protection level of 2.5 KV, CCT 6500K with same lumens/w CRI>80, PF>0.95, THD<10%@240V AC, an operating voltage range of 140-270V and all accessories pre-wired including connecting up with copper conductor wire of suitable size with connector block complete. Make :Havells/Halonix/Orient Electric |
| 29 | S&F surface mounting LED integrated aluminium housing batten with polycarbonate deffuser luminaire not less than 20 W, 4 feet fixture should have minimum efficiency at level >=120lumens/watt, life of fixture not less than 50K Hrs, Ripple<5%, UGR<19, Minimum surge protection level of 2.5 KV, CCT 6500K with same lumens/w CRI>80, PF>0.95, THD<10%@240V AC, an operating voltage range of 140-270V and all accessories pre-wired including connecting up with copper conductor wire of suitable size with connector block complete. Make :Havells/Halonix/Orient Electric |
| 30 | S&F in repair decorative wall mounting light SS finish fixture with extruded glass difuser suitable for up to 40 watt mini glass lamp, lamp holder, including 9 Watts LED bulb having minimum efficiacy at level >=120lumens/watt, life of fixture not less than 50K Hrs, Ripple<5%, UGR<19, Minimum surge protection level of 4 KV, CCT 4000-6500K with same lumens/w CRI>80, PF>0.95, THD<10%@ operating voltage 170V-240V for fixing in decorative wall mounting light and all accessories pre-wired including connecting up including taking down of existing u/s light fitting complete |
| 31 | S&F in repair Supply and fixing LED luminaire 4 X 1 feet, 35/36 watt, 220 VoltAC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete completeMake :Havells/Halonix/Orient Electric |
| 32 | S&F in repair Supply and fixing LED luminaire 600 mm x 600 mm x 70mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete complete. Make :Havells/Halonix/Orient Electric |
| 33 | Supply and fixing in repair LED street light fitting 72/75 Watt 230 Volt AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. pre-wired incl connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections and 50 mm bore light grade G. I. tube mounting bracket of 1.5 meter in length, bend to shape at 140 degree in ‘L’ shape and fixed to wall by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts & washers complete. Make :Havells/Halonix/Orient Electric |
| 34 | Supply and fixing in repair LED street light fitting 35/36 Watt 230 Volt AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. pre-wired incl connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections and 50 mm bore light grade G. I. tube mounting bracket of 1.5 meter in length, bend to shape at 140 degree in ‘L’ shape and fixed to wall by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts & washers complete. Makes - Havells/Halonix/Orient Electric |
| 35 | Material and labour in repair for sub main wiring with 04 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 4 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories and connected to common earth dolly with suitable copper lugs including all cutting / chases etc in walls and making good to the disturbed surfaces complete all as specified & directed, including taking down old sub main wiring. |
| 36 | All as per the description of srl item No 35 but 06 Sqmm nominal cross sectional area. |
| 37 | All as per the description of srl item No 35 but 10 Sqmm nominal cross sectional area, four single core, with and including continuous earth wire of size 06 Sqmm nominal cross sectional area. |
| 38 | S&F in repair industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB, SP, AC, 230 volts of 20 Amps, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces complete |
| 39 | S&F in repair sheet metal enclosure distribution board, single pole and neutral, AC, 230 volts, 08 way, with 200 Amps rated copper bus bar and metal double door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces complete |
| 40 | All as per the description of srl item No 39 but 12 way |
| 41 | S&F in repair sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 440 volts, 04 ways with 200 Amps rated copper bus bar and metal door with IP 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces complete all as specified and directed and comprising of the following :- (a) MCCB, 125 Amps, 04 pole, AC, 415 Volts,16 KA - 01 No. (b) MCB, SP, AC, 230 volts of 06 to 32 Amps, \\"C\\" curve, 10 KA - 12 Nos. |
| 42 | S&F in repair MCB, SP, AC, 230 volts of 06 to 32 Amps capacity \\"C\\" curve, 10 KA breaking capacity and making connections by using copper lugs complete |
| 43 | S&F in repair MCB, DP, AC, 230 volts of 40 Amps capacity \\"C\\" curve, 10 KA breaking capacity and making connections by using copper lugs complete |
| 44 | S&F in repair MCB, DP, AC, 230 volts of 63 Amps capacity \\"C\\" curve, 10 KA breaking capacity and making connections by using copper lugs complete |
| 45 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, Copper winding of sweep 200 mm, cutting of hole in wall, making of wooden frome, all arrangements for mounting of fan including making good of disturbed surface etc complete all as directed |
| 46 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, Copper winding of sweep 250 mm, cutting of hole in wall, making of wooden frome, all arrangements for mounting of fan including making good of disturbed surface etc complete all as directed |
| 47 | S&F in repair MCCB, 63 Amps, 03 pole, AC, 415 Volts of 16 KA breaking capacity complete |
| 48 | S&F in repair MCCB, 100 Amps, 03 pole, AC, 415 Volts of 16 KA breaking capacity complete all as specified & directed. |
| 49 | S&F in repair MCCB, 125 Amps, 03 pole, AC, 415 Volts of 16 KA breaking capacity complete. |
| 50 | S&F or passing through pipe, 10 Sqmm, 2 core, 1100 Volts grade, heavy duty, multi-stranded, PVC insulated, aluminium conductor, served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed service cable for service connections from existing LT Panel/Pole to DB/busbar chamber including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete |
| 51 | S&F in repair garden light fitting 9/10 watts, rated LED, alluminium lighting fixture,Acrylic Defuser, stanless steel screws, Corrosion & UV RAys Reasitant coatting. Bollard light with and including of brick/PCC work all as requad at side but not less than in size as directed by Engr.in Charge Make : Crompton / Halonix/ Havells |
| 52 | Supply and fix exhaust fan, steel body AC single Phase. 230 Volts of size 450 mm sweep heavy duty with, blades, and frame and louvers and taking down old exhaust fan and depositing to MES store yard, all arrangements for mounting of fan including making good of disturbed surface etc complete all as directed |
| 53 | Supply and fix exhaust fan, steel body AC single Phase. 230 Volts of size 300 mm sweep with, blades, and frame and louvers and taking down old exhaust fan and depositing to MES store yard all arrangements for mounting of fan including making good of disturbed surface etc complete all as directed |
| 54 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection pipes etc.including grouting of bolts for fixing complete and taking down old/unsv fan and deposit in E/M store yard all as directed at site by Engr-in-charge. |
| 55 | S&F in replacement , Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 220 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 Volts 50 Hz, single phase AC Supply, earthing etc. complete as required including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block to ceiling rose complete . and taking down old/unsv fan and deposit in E/M store yard complete all as specified and directed |
| 56 | M&L for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried vertically in ground (earth pit not less than 2.25meter deep below ground level) with top edge of the plate not less than 1.5meter below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete. Note:- On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.) |
| 57 | Supply and fixing in repairs LED post top lantern 20 Watt with die cast aluminium spigot spun aluminium powder coated top cover aluminium clear acrylic and IP 65/66 including connecting up with provision of PVC insulated copper conductor cable 1.5 Sqmm, 2/3 core as required for connections,with and incl all PCC works reqd at site complete all as specified and directed. Make : Crompton / Halonix/ Havells Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
TodayCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 7 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender