Tender For Repair / Maintenance Of Sewage Line, Septic Tank, Manhole, Stp Incl Cleaning Work Of Drain In New Cantt Under Ge Gangtok
Tender Value
30 Lakhs
Estimated cost
Bid Submission
05 Aug 2026
5 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
sikkim → Sikkim
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair / Maintenance Of Sewage Line, Septic Tank, Manhole, Stp Incl Cleaning Work Of Drain In New Cantt Under Ge Gangtok
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exc. 1.5 metre deep and not exc. 1.5 metre wide and n. Exc 10sqm on plan getting out as in soft/loose soil for foundation etc complete all as specified and directed. |
| 2 | Excavation in trenches exc. 1.5 metre deep and not exc. 3.00 metre wide and n. Exc 10sqm on plan getting out as in soft/loose soil for foundation etc complete all as specified and directed. |
| 3 | Returning, filling in, including spreading levelling watering and well ramming in layers not exceeding 25 cms in thick as in soft/loose soils complete all as specified and directed. |
| 4 | Removing surplus soils to a distance not exceeding 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point complete all as specified and directed. |
| 5 | Demolition of precast block masonary or precast concrete article built in cement mortar complete all as diected. |
| 6 | Demolition/Dismantling and breaking up of drain pipes (AC, PVC or SWR or Reinforced cement concrete) 150mm dia (Internal), set in cement mortar including taking out from trenches,PCC bed, haunching set in CM and removing from site complete all and directed. |
| 7 | Demolition/Dismantling and breaking up of drain pipes (AC, PVC or SWR or Reinforced cement concrete) 200mm dia (Internal), set in cement mortar including taking out from trenches, PCC bed, haunching set in CM and removing from site complete all as specified and directed. |
| 8 | M&L for PCC 1:3:6 type C-2 (by using 40 mm graded stone aggregate) as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150ID/172ODmm dia DWCPE pipe, and 150mm bore NP3 pipe, complete all as specified and directed. |
| 9 | M&L for PCC 1:3:6 type C-2 (by using 40 mm graded stone aggregate) as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 200ID/232ODmm dia DWCPE pipe and NP3 pipe, complete all as specified and directed. |
| 10 | S&F for reinforced concrete pipes, class NP3, laid and jointed complete with collars of 150mm bore complete all as specified and as directed. |
| 11 | M&L for 150ID/170 (OD)mm dia DWCPE SN8 pipe single socketed, in length with joints laid in trenches or in floors Confirming to IS 16098(pt-2) complete all as specified and as directed. |
| 12 | M&L for 200(ID)/ 232 (OD)mm dia DWCPE SN8 pipe single socketed, in length with joints laid in trenches or in floors Confirming to IS 16098(pt-2) complete all as specified and as directed. |
| 13 | S&F in repair 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to wall, laid in trenches or in floor with all necessary clamps,bolts, bends, Tee etc complete all as specified and as directed. |
| 14 | S&F in repair 150 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to wall, laid in trenches or in floor with necessary clamps, bolts, bends, Tee etc.complete all as specified and as directed. |
| 15 | S&F in repair for PVC(SWR) 75mm pipes single socketed, in any length with rubber ring joints, laid in trenches or in floor with necessary clamps, bolt, bends, Tee all as specified and directed. |
| 16 | M&L for cutting into existing manholes for connecting new drains (internal dia pipe 150mm to 200mm), making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-I smooth finished, and reforming benching complete all as specified and directed. |
| 17 | M&L for precast PCC 1:3:6 type C1 (by using 20mm graded stone aggregate) block masonry with solid blocks, exc 10 cm in width and setting in CM 1:6 complete all as specified and directed. |
| 18 | Taking down cement plaster on brick or stone walls or concrete surface, including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 19 | M&L for 20 mm thick rendering in two layer (10mm thick each layer) in CM 1:4 and top layer with using water proofing compound as per manufactures instructions on fair faces of brick or concrete surfaces, finished even & fair with using extra cement complete all as directed.Note :- WPC will be measured and paid seperately as supply only) |
| 20 | M&L for 15 mm thick rendering in CM (1:6) on other than fair faces of brick or concrete surfaces, finished even & fair with using extra cement complete all as directed. Please Enable Macros to View BoQ information |
| 21 | M&L for 15 mm thick rendering in CM (1:6) on other than fair faces of brick or concrete surfaces, finished even & fair with using extra cement complete all as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysAug 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender