Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #56652512

Tender For Day To Day Maintenance Of Electrical Fittings And Fixtures In Tech And Domestic Area At 3 Brd Under Ge (Af) Mc Chandigarh

Issued by Statutory Bodies & Commissions/Committees · Chandigarh, Chandigarh
Tender Value
30 Lakhs
Estimated cost
Bid Submission
22 Aug 2026
0 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Day To Day Maintenance Of Electrical Fittings And Fixtures In Tech And Domestic Area At 3 Brd Under Ge (Af) Mc Chandigarh

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 15-Aug-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 22-Aug-2026

BOQ

Name of Work:- DAY TO DAY MAINT OF ELECTRICAL FITTINGS AND FIXTURES IN TECH AND DOMESTIC AREA AT 3 BRD UNDER GE (AF) MC CHANDIGARH
Sl. No. Item Description
1Taking down carefully aluminum/copper point wiring (light, fan, socket any type, power, bell etc. complete including fixtures & fittings (such as ceiling rose, socket, Pendent, regulator, light fitting etc) and removing the material from site and making good the disturbed surfaces of walls, ceiling etc complete all as directed.
2M & L for Concealed Point wiring with 1.5 Sqmm (nominal area) single core PVC insulated unsheathed (FRLS) cable, multi-stranded, copper conductor, in universal colour code with & including suitable size of rigid non-metallic PVC conduit (not less then 20mm dia medium grade) and its all accessories complete concealed in wall / roof incl cutting & chases and modular flush metal boxes 0.8 mm thick suitable for modular fittings including modular outer cover plate. Make : Legrand (Arteor)/ Schneider (Zencelo)/ Anchor (Panasonic Thea)/ Goldmedal (Nixon Quorra) with inner frame suitable for cover plate as per site requirement for mounting modular switches, sockets, etc including earth wire of PVC insulated (FRLS) copper conductor multistranded of 1.5 Sqmm size in green colour complete including making good (i.e plastering in cement mortar 1:6, one coat of putti and two coats of interior emulsion paint with matching existing surface) all as specified in current SSR Part-I & II all as directed for One light point/exhaust/ceiling fan/bell controlled by one way switch 6 Amp complete as directed.
3All as per item No 2 here-in-before but for One 3 pin 6 Amps socket point controlled by one switch on same board.
4All as per Item No 2 here-in-before but for One 3 pin 6 Amps socket point controlled by one Modular switch on independent board.
5All as per item No. 2 here-in-before but for 3 pin / 5 pin 16 Amps sockets outlet with 2.5 Sqmm PVC insulated & unsheathed (FRLS) copper conductor cable, main wire and earth wire independent complete all as specified and as directed.
6Supply and Fixing Modular switch 16/20 Amp single pole one way, 2 Module with indicator and no top gap between rocker plate and fully shrouded double rocker mechanism type all the importent parameters like rating etc should be laser printed on every switch along with catalogue number all as specified. Make : Legrand (Arteor) / Schneider (Zencelo) / Anchor (Panasonic Thea).
7Supply and Fixing Modular socket shutter type, 2-in-1, 3 and 5 pins 6 /16 Amps, combined 2 Module and no top gap between rocker plate and fully shrouded double rocker mechanism type all the important parameters like rating etc should be laser printed on every switch along with catalogue number complete all as specified.Make : Legrand (Arteor) / Schneider (Zencelo) / Goldmedal (Nexon)
8Supply and Fixing Ceiling rose surface bakelite square in shape size 100mm, three terminals complete all as specified.
9Supply and Fixing of Modular switch 6 Amps single pole one-way, 1 Module and no top gap between rocker plate and fully shrouded double rocker mechanism type all the important parameters like rating etc should be laser printed on every switch along with catalogue number complete all as specified. Make : Legrand (Arteor) / Schneider (Zencelo) / Anchor (Panasonic Thea)/ Goldmedal (Nixon Quorra)
10Supply and Fixing of Modular socket shutter type, 2-in-1, 3 pins 6 Amps, ISI marked, combined 2 Module and no top gap between rocker plate and fully shrouded double rocker mechanisam type all the importent parameters like rating etc should be laser printed on every switch along with catoulage number complete all as specified. Make : Legrand (Arteor)/ Schneider (Zencelo)/ Anchor (Panasonic Thea)/ Goldmedal (Nixon Quorra)
11Supply & Fixing of Modular fan Regulator electronic step type 100 watt, ISI marked, 2 Module complete all as specified. Make : Legrand (Arteor)/ Schneider (Zencelo)/ Anchor (Panasonic Thea)/ Goldmedal (Nixon Quorra)
12Supply and fixing of light type LED, 200- 240 Volts, Muziris Picture Light-12W, lighting method Downward bulb base E27, warm/cool/natural as per site requirement, wall mount with all accessories complete connections all as specified and directed. Make :- Philips/ Jaquar/ Havells.
13S&F recess mounting LED 36W 2'x2' tile in CRCA housing with full opal diffuser suitable for Armstrong/Grid ceilings with revolutionary flicker controlled technology to reduce harmful invisible flicker present in LED lighting sources all as specified and directed.
14S&F surface mounting LED 36W 2'x2' tile in CRCA housing with full opal diffuser suitable for RCC ceilings with revolutionary flicker controlled technology to reduce harmful invisible flicker present in LED lighting sources all as specified and directed.
15Supply and fix Lamp holder, PVC / polycarbonate type with back plate suitable for batten fittings complete all as specified.
16Supply and fixing SPN 40- 63 Amps,' C' series, bracking cap10KA, 240V complete all as specified.
17Supply and fixing in replacement of MCB Single pole 6 to 32 Amp, 240V, 10KA, 'B' curve curve with indicator light complete all as specified & directed.Make :- Gold medal/ Havells/ Legrand.
18Supply and fix Plexo box, IP 55, 3 module with adaptor and PVC membrane, grey in colour all as specified and directed.
19Supply and fixing in replacement of MCB DB Single pole and neutral 12 way sheet steel phospehtised powder painted with IP 43 protection 240 V neutral link, earth bar and Din rail double door complete including making good (i.e plastering in cement mortar 1:6, one coat of putti and two coats of interior emulsion paint with matching existing surface) all as specified and directed.Make : Goldmedal/ Legrand/ Havells.
20Supply and fixing in replacement of MCB DB Single pole and neutral 08 way sheet steel phospehtised powder painted with IP 43 protection 240 V neutral link, earth bar and Din rail double door completeincluding making good (i.e plastering in cement mortar 1:6, one coat of putti and two coats of interior emulsion paint with matching existing surface) all as specified and directed.Make : Goldmedal/ Legrand/ Havells.
21Suply and fixing in replacement MCB distribution board, SPN 4 Way, Double door, IP 43 rated, concealed in wall sheet steel, phosphatised, powder painted with Copper bus-bar 100Amp, neutral link, earth bar and din rail , cable ties for cable management, 240 V, completeincluding making good(i.e plastering in cement mortar 1:6, one coat of putti and two coats of interior emulsion paint with matching existing surface) all as specified. Make : Havells/ Legrand/ Goldmedal.
22Material and labour for Concealed Sub Main Wiring with two run single core 1.5 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed 1100 volts grade colour code cables, drawn on surface in and including UPVC conduit of 25mm dia bore medium grade, including standard fittings such as Tees, junction, bends etc., with and including one run of continuous multi stranded copper conductor 1.5Sqmm (nominal area) FRLS PVC insulated and unsheathed 1100volts grade colour code cable for earth continuity including making good (i.e plastering in cement mortar 1:6, one coat of putti and two coats of interior emulsion paint with matching existing surface) including taking down old, complete all as specified and directed.Note :- Two run of 1.5 Sqmm + One run of 1.5 Sqmm for earth wire + one run of UPVC conduit shall be measured as one RM.
23Material and labour for Concealed Sub Main Wiring with two run single core 2.5 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed 1100volts grade colour code cables, drawn on surface in and including UPVC conduit of 25mm dia bore medium grade, including standard fittings such as Tees, junction, bends etc., with and including one run of continuous multi stranded copper conductor 2.5Sqmm (nominal area) FRLS PVC insulated and unsheathed 1100volts grade colour code cable for earth continuity including making good (i.e plastering in cement mortar 1:6, one coat of putti and two coats of interior emulsion paint with matching existing surface) including taking down old, complete all as specified and directed.Note :- Two run of 2.5 Sqmm + One run of 2.5 Sqmm for earth wire + one run of UPVC conduit shall be measured as one RM.
24Material and labour for Sub Main Wiring with two run single core 4 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed 1100volts grade colour code cables, drawn on surface in and including UPVC conduit of 25mm dia bore medium grade, including standard fittings such as Tees, junction, bends etc., with and including one run of continuous multi stranded copper conductor 4 Sqmm (nominal area) FRLS PVC insulated and unsheathed 1100 volts grade colour code cable for earth continuity including making good (i.e plastering in cement mortar 1:6, one coat of putti and two coats of interior emulsion paint with matching existing surface) including taking down old, complete all as specified and directed.Note :- Two run of 4 Sqmm + One run of 4 Sqmm for earth wire + one run of UPVC conduit shall be measured as one RM.
25Material and labour for Sub Main Wiring with two run single core 6.0 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed 1100 volts grade colour code cables, drawn on surface in and including UPVC conduit of 25mm dia bore medium grade, including standard fittings such as Tees, junction, bends etc., with and including one run of continuous multi stranded copper conductor 6 Sqmm (nominal area) FRLS PVC insulated and unsheathed 1100volts grade colour code cable for earth continuity including making good (i.e plastering in cement mortar 1:6, one coat of putti and two coats of interior emulsion paint with matching existing surface) including taking down old complete all as specified and directed.Note :- Two run of 6 Sqmm + One run of 6 Sqmm for earth wire + one run of UPVC conduit shall be measured as one RM.
26Material and labour for Sub Main Wiring with Four run single core 10 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed 1100volts grade colour code cables, drawn on surface in and including UPVC conduit of 32 mm dia bore medium grade, including standard fittings such as Tees, junction, bends etc., with and including Two run of continuous multi stranded copper conductor 10 Sqmm (nominal area) FRLS PVC insulated and unsheathed 1100volts grade colour code cable for earth continuity including making good (i.e plastering in cement mortar 1:6, one coat of putti and two coats of interior emulsion paint with matching existing surface) including taking down old, complete all as specified and directed.Note :- Four run of 10 Sqmm + One run of 10 Sqmm for earth wire + one run of UPVC conduit shall be measured as one RM. Please Enable Macros to View BoQ information
27Material and labour for Sub Main Wiring with Four run single core 10 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed 1100volts grade colour code cables, drawn on surface in and including UPVC conduit of 32 mm dia bore medium grade, including standard fittings such as Tees, junction, bends etc., with and including Two run of continuous multi stranded copper conductor 10 Sqmm (nominal area) FRLS PVC insulated and unsheathed 1100volts grade colour code cable for earth continuity including making good (i.e plastering in cement mortar 1:6, one coat of putti and two coats of interior emulsion paint with matching existing surface) including taking down old, complete all as specified and directed.Note :- Four run of 10 Sqmm + One run of 10 Sqmm for earth wire + one run of UPVC conduit shall be measured as one RM. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56652512
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 30 Lakhs
LAST DATE 22-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Day To Day Maintenance Of Electrical Fittings And Fixtures In Tech And Domestic Area At 3 Brd Under Ge (Af) Mc Chandigarh
Basic Detail
Tender No GE (AF) MC/CHD/T-49/2026-27
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 15 Aug 2026
Submission Date 22 Aug 2026
Open Date 24 Aug 2026
Finance
Tender Value 30 Lakhs
Tender Fee 500
EMD 60000
Exemption Available
Document List
a359e47e-674f-4129-93d6-12aa12c14e5a.html
BOQ_874509.xls
TenderDocument49.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 22, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Aug 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Today

Tender Documents

Download All (ZIP) ↓
html

a359e47e-674f-4129-93d6-12aa12c14e5a.html

xls

BOQ_874509.xls

pdf

TenderDocument49.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders