Tender For Repair / Maintenance Of Street Lights, Security Lights And Perimeter Lights And Connected Works In Pinto Park Area Under Ge (Af) Palam, Delhi Cantt - 10

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
20 Lakhs
Estimated cost
Bid Submission
21 Aug 2026
6 days left
EMD
40000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair / Maintenance Of Street Lights, Security Lights And Perimeter Lights And Connected Works In Pinto Park Area Under Ge (Af) Palam, Delhi Cantt - 10

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 01-Aug-2026 CORRIGENDUM NO 1 Other 14-Aug-2026
2 14-Aug-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 21-Aug-2026

BOQ

Name of Work:- REPAIR / MAINT OF STREET LIGHTS, SECURITY LIGHTS AND PERIMETER LIGHTS AND CONNECTED WORKS IN PINTO PARK AREA UNDER GE (AF) PALAM, DELHI CANTT - 10
Sl. No. Item Description
1M&L for servicing / overhauling of High Mast light assembly of any make model, capacity, height by greasing of wire rope, winch, motor with complete function, proper connection of light fittings in lantern carriage, cleaning of High Mast panel including replacement of unserviceable high mast fittings complete all as specified and as directed by Engineer-in-Charge.
2S&F in replacement of steel wire rope of high mast light from winch to top made out of stainless steel grade AISI 316 suitable for taking minimum 750 kg load as per existing rope size etc complete all as specified and as directed. Make:- USHA / Ashai / Bw ltd
3Supply & fixing in replacement of weather proof, PVC insulated, PVC sheathed, unarmoured flexible cable, with multistranded copper conductor of size 4 sqmm, 3 core fixed from Junction box to high mast light fittings etc complete all as specified and as directed.
4M&L for repairing of 1-1.5 HP capacity electric motor of high mast, AC 3 phase, dismantling the motor cutting and taking out the old winding wires, cleaning the slots, rewinding the motor with appropriate size of super insulated copper conductor winding wire of same gauge, and varnishing complete including replacing the worn out bearing reassembling the motor fixing in same position and testing complete all as specified and directed by Engr In charge.
5Supply only PVC insulation tape of size 18 mm *6 mtr long FR grade (R/G/B/N colour code) complete all as specified and as directed.
6S&F in replacement of LED street light fitting 120 Watt, system efficiency not less than 100-120 lumen / watt, IP66 including 10KV SPD, consisting of high / low voltage cut off, maintenance free isolated electronic driver circuits, low THD, PMMA grade high quality transmittance lens, epoxy powder coated die cast aluminium housing with weather proof gasket for lamp & driver compartment, heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting complete all as specified and as directed. Make:- Eveready /Halonix/Bajaj/CG.
7S&F in replacement of LED street light fitting 90 Watt, system efficiency not less than 100-120 lumen / watt, IP66 including 10KV SPD, consisting of high / low voltage cut off, maintenance free isolated electronic driver circuits, low THD, PMMA grade high quality transmittance lens, epoxy powder coated die cast aluminium housing with weather proof gasket for lamp & driver compartment, heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting complete all as specified and as directed. Make:- Eveready /Halonix/Bajaj/CG
8S&F in replacement of LED street light fitting 60 Watt, system efficiency not less than 100-120 lumen / watt, IP66 including 10KV SPD, consisting of high / low voltage cut off, maintenance free isolated electronic driver circuits, low THD, PMMA grade high quality transmittance lens, epoxy powder coated die cast aluminium housing with weather proof gasket for lamp & driver compartment, heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting complete all as specified and as directed. Make:- Eveready /Halonix/Bajaj/CG
9S&F in replacement double dome LED type aviation obstruction light provided on top of high mast. Led lamp 2nos x 100watt aviation obstruction light fitted in a weather- proof box on body unit of aluminium alloy complete all as specified and as directed by Engr-in-charge.
10S&F in replacement of LED flood light fitting 200 Watt, system efficiency not less than 100-120 lumen / watt, IP66 including 10KV SPD, consisting of high / low voltage cut off, maintenance free isolated, electronic driver circuits, low THD, PMMA grade high quality transmittance lens, epoxy powder coated die cast aluminium housing with weather proof gasket for lamp & driver compartment, heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing high mast & connecting complete all as specified and as directed. Make:- Eveready /Halonix/Bajaj/CG
11S&F in replacement of LED flood light fitting 150 Watt, system efficiency not less than 100-120 lumen / watt, IP66 including 10KV SPD, consisting of high / low voltage cut off, maintenance free isolated electronic driver circuits, low THD, PMMA grade high quality transmittance lens, epoxy powder coated die cast aluminium housing with weather proof gasket for lamp & driver compartment, heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing high mast & connecting complete all as specified and as directed. Make:- Eveready /Halonix/Bajaj/CG
12S&F in replacement of LED flood light fitting 100 Watt, system efficiency not less than 100-120 lumen / watt, IP66 including 10KV SPD, consisting of high / low voltage cut off, maintenance free isolated electronic driver circuits, low THD, PMMA grade high quality transmittance lens, epoxy powder coated die cast aluminium housing with weather proof gasket for lamp & driver compartment, heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing high mast & connecting complete all as specified and as directed. Make:- Eveready /Halonix/Bajaj/CG
13Excavation in trenches in soft/loose soil not exceeding 1.50 Mtrs wide and not exc. 1.5 Mtr deep and getting out for taking out/laying cable, poles & stay etc complete all as specified and as directed by Engr-in-Charge.
14All as per item No 13 here-in-before but exceeding 1.5 m and not exceeding 3.0 m in depth complete all as specified and as directed by Engr-in-Charge.
15Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25cm thick after the cable have been laid, tested complete all as specified and as directed by Engineer-in-Charge
16Removal of excavated surplus soil to a distance not exc. 50 Mtrs and depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and as directed by Engr-in-charge
17M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15cm deep after laying the cable ie total 23cm, punned thickness i.e. 18cm shall be measured and paid) complete all as specified and as directed.
18M&L for brick burnt clay sub class ‘B’ laid in trenches for cable protection of complete laid dry flat complete all as specified and as directed.
19M&L for augering of holes in true horizontal position under road /pavement by means of mechanical rig after doing ultrasound technique to prevent any damage to existing cables/pipe lines coming in route 1.5 Mtr deep and not exceeding 15 Mtrs long including laying HDPE/GI pipe upto150mm dia complete all as specified and as directed.
20S&F in replacement of analog type time switch 3P module, DIN 24 hours programmable every 30 minutes of current capacity 32 Amps with one change over including connecting to existing power contactor complete as specified and as directed.
21Taking out old unserviceable LT under ground cable any type from trenches, pipes & poles complete all as specified and as directed.
22Supply and laying in replacement XLPE LT 1100 Volt grade, armoured under ground cable size of 10 sqmm 2 core with stranded aluminium conductor in trenches /passing through pipes/ on poles etc complele all as specified and as directed.
23All as per srl item No 22 above but 16 Sqmm 2 core complele all as specified and as directed.
24All as per srl item No 22 above but 16 Sqmm 4 core complele all as specified and as directed.
25All as per srl item No 22 above but 25 Sqmm 4 core complele all as specified and as directed.
26All as per srl item No 22 above but 70 Sqmm 3.5 core complele all as specified and as directed.
27All as per srl item No 22 above but 120 Sqmm 3.5 core complele all as specified and as directed.
28All as per srl item No 22 above but 50 Sqmm 3.5 core complele all as specified and as directed.
29All as per srl item No 22 above but 95 Sqmm 3.5 core complele all as specified and as directed.
30All as per srl item No 22 above but 35 Sqmm 3.5 core complele all as specified and as directed. Note:- Excavation, earthwork and protection of cable shall be measured and paid seperately.
31Supply & jointing heat shrinkable straight through joint suitable for LT 1100 Volt grade XLPE cable of size 150-70 sqmm 3.5 core complete with treating of cable to make ready for jointing complele all as specified and as directed.
32Ditto all as per item No 31 but of size 35 -50 sqmm 3.5 core complele all as specified and as directed.
33M&L for defect rectification LT cable laid in trenches by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc. including and additional excavation in normal alluvial strata required for exposing the cable fault removal of deteriorated portion of cable treating of cable and keeping the same ready for jointing work for cable of size up to 240 sqmm 3.5 core. Note:- The fault locating equipments shall be brought to site within the two hours of instruction from Engr-in-Charge.
34S&F in replacement of GI tubing 50 mm bore, light grade laid in tenches for cable protection, under the road/path/along the pole complete all as specified and as directed.
35S&F in replacement of GI tubing 80 mm bore, light grade laid in tenches for cable protection, under the road/path/along the pole complete all as specified and as directed.
36M&L for PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundation/post hole complete all as specified and as directed.
37M&L for PCC (1:3:6) type C1 (using 20mm graded stone aggregate) for making coping of LT poles complete all as specified and as directed by Engr-in-Charge.
38M&L for junction box outdoor in replacement, 3 phase 415 Volts of size (350 x 250 x 150)mm made out of hot press moulded SMC front openable hinged type including 4 Nos. Aluminium bus bars mounted on insulators heavy duty of rating 32 Amps with necessary fixing arrangements to pole with MS calmps, nuts, bolts etc of size (25 x 4)mm duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. Make:- Sintex/Hensel/L&T
39Supply and fixing in replacement of street light fitting bracket fabricated of 40mm GI tubing duly bent to shape, 1.5 mtr long complete alongwith two Nos MS clamps of size (40 x 5)mm and nut, bolts & washers complete all as specified and as directed by Engr-in-Charge.
40M&L in replacement of three core 1.5 sqmm copper conductor cable for connecting up street/ security light with pole junction box complete all as specified and as directed.
41Supply and fixing in replacement of MCCB 63 Amp, 4 pole 16 kA necessary connection including taking out old existing unserviceable MCCB from panels etc complete all as specified and as directed. Make:- Havells/HPL/L&T
42S&F in replacement of MCCB 400 Amps 4 pole 35/36 kA 415 Volts 50 Hz with thermal adjustable magnetic settings, Icu=Ics, necessary conection from panels etc complete all as specified and as directed. Make:- Havells/HPL/L&T
43S&F in replacement of MCCB 315 Amps 4 pole 35/36 kA 415 Volts 50 Hz with thermal adjustable magnetic settings, Icu=Ics, necessary conection from panels etc complete all as specified and as directed. Make:- Havells/HPL/L&T
44S&F in replacement of MCCB 160 Amps 4 pole 16 kA 415 Volts 50 Hz with thermal adjustable magnetic settings, Icu=Ics, necessary conection from panels etc complete all as specified and as directed. Make:- Havells/HPL/L&T
45S&F in replacement of MCCB 125 Amps 3 pole 16 kA 415 Volts 50 Hz with thermal adjustable magnetic settings, Icu=Ics, necessary connection from panels etc complete all as specified and as directed. Make:- Havells/HPL/L&T
46Supply and fixing MCB, SPN 32 Amp,10 kA complete all as specified and as directed.
47Supply and fixing MCB, SP, 6-32 Amp,10 kA complete all as specified and as directed.
48Material and labour for submain wiring with two single core 4 sqmm PVC insulated FRLS multistranded copper conductor cable drawing into and including rigid non metallic PVC conduit, medium grade ISI marked with all conduit fittings & fixing accessories and one single core 4 sqmm FRLS multistranded copper conductor cable as continuous earth wire complete all as specified and as directed.
49S&F in replacement of LED bollard of capacity 10/11 watt, IP 65/66 for garden/pathway made with aluminium extrusion for studdiness with polycarbonate diffuser complete all as specified and as directed. Make:- Eveready /Halonix/Bajaj/CG
50S&F in replacement indirect decorative LED post top lantern 40/45W, IP65 with die cast aluminium spigot, powder coated aluminium reflector complete all as specified and as directed. Make:- Eveready /Halonix/Bajaj/CG
51S&F LED post top lantern 20 W with die cast aluminium spigot, spun aluminium powder coated top cover aluminium PDC heat sink, opal PC diffuser and clear acrylic IP65 complete all as specified and as directed. Make:- Halonix/Bajaj/Havells
52Supply and fixing in replacement of power contactor 32-40 Amp, 4 pole for timer panel complete all as specified and as directed. Make:- HPL/ L&T/ Havells
53M&L for refixing the interlocking tiles of any description taken out during excavation from the surface after placing the pipe in trenches and making good disturbed surface complete all as specified and as directed by Engr in charge.
54Supply, installation & testing in replacement of outdoor type, weather proof, cubical LT cable junction box made out of 3.15 mm thick MS/CRCA steel sheet mounted on 60cm long legs made out of (40 x 40 x 6) mm equal angle, embedded in PCC (1:2:4) type B-1 blocks of size (15 x 15 x 20)cm, front and back openable, double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz , factory fabricated with suitable foamed-in PU gasket to make it dust/vermin proof, IP 54 protection, powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI approved & submit certificate for short circuit current of 50 kA for one second and similar design and technology shall be adopted from manufacturer of the panel complete in all respects alongwith provision of cable gland for cable entry/out. The junction box shall be auminium bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 400 amps for three phases and one neutral alongwith provision for in/out LT cable with suitable size gland complete all as specified and as directed by Engr in charge.
55Supply, installation & testing in replacement of outdoor type, weather proof, cubical LT cable junction box made out of 3.15 mm thick MS/CRCA steel sheet mounted on 60 cm long legs made out of (40 x 40 x 6) mm equal angle, embedded in PCC (1:2:4) type B-1 blocks of size (15 x 15 x 20)cm, front and back openable, double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz, factory fabricated with suitable foamed-in PU gasket to make it dust/vermin proof, IP 54 protection, powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI approved & submit certificate for short circuit current of 50 kA for one second and similar design and technology shall be adopted from manufacturer of the panel complete in all respects alongwith provision of cable gland for cable entry/out. The junction box shall be auminium bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 600 amps for three phases and one neutral alongwith provision for in/out LT cable with suitable size gland complete all as specified and as directed by Engr in charge.
56M&L for preparation of old painted steel tubular pole 11/9 metre height by scrapping with steel wire brush and cleaning the rust of pole and cross arm and applying two coats of aluminium paint over and a coat of red oxide primer above 1.5 m height and painting blue and white strips (30 cm width) with synthetic enamel paint upto 1.5 m height from bottom point, and writing the existing pole number with radium sticker in yellow circle of dia 150mm complete all as specified and as directed.
57M&L for painting to PCC pole 11/9 meter height using one coat white cement paint on pole including cross arms, clamp & bracket of any type and any size by a coat of synthetic enamel paint with white /blue 30cm wide strip upto the height of 1.5 mtr above ground level and marking the pole No in 4” dia yellow paint circle complete all as specified and as directed.
58M&L for earthing in replacement of with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to GI strip (32 x 6)mm as earth lead by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC (1:3:6) type C-1 (using 20mm graded stone aggregate), with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM (1:4), funnel with wire gauge mesh, 80mm thick RCC pit cover 320mm x 320mm of RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of GI strip protected by 40mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, and including all excavation and earth work & connecting the earthing to an earthing test point complete all as specified & directed by Engr-in-Charge.
59M&L for earthing in replacement with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to GI 4mm dia wire as earth lead by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC (1:3:6) type C-1 (using 20mm graded stone aggregate), with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM (1:4), funnel with wire gauge mesh, 80 mm thick RCC pit cover 320mm x 320mm of RCC (1:2:4) type B-1 (using 20mm graded stone aggregate) reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of GI strip protected by 15mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, and including all excavation and earth work & connecting the earthing to an earthing test point complete all as specified & as directed by Engr-in-Charge.
60Supply and fixing steel tubular swaged poles with cast iron base plate, finial taper plug bolts, nuts, screws as specified type 410 SP-31 (9.0 Mtr long) including embossing the manufacturer's name and IS No of pole and erecting in position all as specified and directed with and including providing painting the exposed portion with two coats of aluminium paint over a coat of red oxide primer and internally through out plus embedded portion with two coats of black bituminous paint over a coat red oxide primer and painting of 30cm wide blue and white strips upto 1.5 mtr from bottom of the erected pole including marking of pole number complete with all accessories including demolition/dismantling of concrete and remove from site complete all as specified and as directed. Note:- Necessary excavation, earth work and PCC shall be measured and paid separately.
61Supply and fixing in replacement of time switch distribution board made out with MS box 2mm thick with analog type time switch complete with 3 pole power contactor 32 Amps and time switch, ON/OFF switch, indicator and control wiring complete all as specified and as directed. Make:- Indoasian Cat Part No. TL032ABO or equivalent in make HPL/L&T.
62M&L for PVC insulated service cable flat or round sheathed, aluminium, multistranded conductor 1100V grade size 16 sqmm 2 core complete all as specified and as directed.
63M&L for PVC insulated service cable flat or round sheathed, aluminium, multistranded conductor 1100V grade size 10 sqmm 2 core complete all as specified and as directed.
64M&L for PVC insulated service cable flat or round sheathed, aluminium, multistranded conductor 1100V grade size 6 sqmm 2 core complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56652500
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 20 Lakhs
LAST DATE 21-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Maintenance Of Street Lights, Security Lights And Perimeter Lights And Connected Works In Pinto Park Area Under Ge (Af) Palam, Delhi Cantt - 10
Basic Detail
Tender No 8026/A/T-43/E8
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 14 Aug 2026
Submission Date 21 Aug 2026
Open Date 28 Aug 2026
Finance
Tender Value 20 Lakhs
Tender Fee 500
EMD 40000
Exemption Available
Document List
3f8d11cf-fde3-4da0-92b5-b94cb5a6d6c7.html
BOQ_874469.xls
tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 14, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Aug 21, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 6 days
Aug 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Aug 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
html

3f8d11cf-fde3-4da0-92b5-b94cb5a6d6c7.html

xls

BOQ_874469.xls

pdf

tender.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail