Tender For Provision Of New Visitor Management And Waiting Area Near Security Gate At Arde Pashan, Pune
Tender Value
1.69 Crore
Estimated cost
Bid Submission
28 Aug 2026
32 days left
EMD
2.44 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision Of New Visitor Management And Waiting Area Near Security Gate At Arde Pashan, Pune
BOQ
| Sl. No. | Item Description |
| 1 | Schedule 'A' Part-I (BUILDINGS AND STRUCTURES)This Schedule (contains under mentioned Sl item No. 1.01) is not prepriced by MES and the prepriced rate indicated in Col - 5 as ₹0.00 indicates this fact only. The tenderer is required to quote their rates in Col 6. |
| 2 | Lumpsum price worked out by the contractor for Construction of Visitor Management and Waiting area building in G+1 storey along with independent adjacent Toilet block and mild steel gate with permanent specifications in RCC framed structure including all fittings and fixtures complete all as specified and as shown on drawings. |
| 3 | Lump sum price worked out by the Contractor for “EXCAVATION AND EARTHWORK” as listed in Schedule ‘A’ Part - II representing __________ % ________________ percent Above / Below the lump sum price of ₹31,692.10 inserted by the MES in Schedule ‘A’ Part - II |
| 4 | Lump sum price worked out by the Contractor for “PATH / HARDSTANDING” as listed in Schedule ‘A’ Part - III representing _________ % ___________________ percent Above / Below the lump sum price of ₹11,31,621.40 inserted by the MES in Schedule ‘A’ Part - III |
| 5 | Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part - IV representing ______ % ___________ percent Above / Below the lump sum price of `77,433.75 inserted by the MES in Schedule ‘A’ Part - IV |
| 6 | Lump sum price worked out by the Contractor for “FENCING AND GATE” as listed in Schedule ‘A’ Part - V representing __________ % __________________ percent Above / Below the lump sum price of ₹7,15,567.18 inserted by the MES in Schedule ‘A’ Part - V |
| 7 | Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - VI representing __________ % ____________ percent Above / Below the lump sum price of `2,61,890.00 inserted by the MES in Schedule ‘A’ Part - VI |
| 8 | Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - VII representing ________ % ____________ percent Above / Below the lump sum price of `31,675.40 inserted by the MES in Schedule ‘A’ Part - VII |
| 9 | Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - VIII representing ________ % __________________ percent Above / Below the lump sum price of ₹22,144.13 inserted by the MES in Schedule ‘A’ Part - VIII |
| 10 | Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - IX representing _________ % ________________ percent Above / Below the lump sum price of `11,348.80 inserted by the MES in Schedule ‘A’ Part - IX |
| 11 | Lump sum price worked out by the Contractor for “AIR CONDITIONING” as listed in Schedule ‘A’ Part - X representing _______ % ______________ percent Above / Below the lump sum price of ₹1,20,612.00 inserted by the MES in Schedule ‘A’ Part - X |
| 12 | Schedule 'A' Part - XIThis Schedule is not prepriced by MES and the prepriced rate indicated in Col - 5 as ₹0.00 indicates this fact only. The tenderer is required to quote their rates in Column 6. This Schedule constitutes Sl. Item Nos. 12.00 to 61.00. |
| 13 | INTERNAL ELECTRIFICATIONM&L for point wiring (concealed wiring) of any length using approved colour coding as per IS, with multistranded copper conductor 1.5 Sqmm (nominal area), single core, PVC insulated and unsheathed stranded FRLSH cable 1100 volts grade, in PVC rigid conduits heavy duty, medium grade, ISI marked (min 20mm dia) with valid CML No., totally concealed in wall / floor and casing along roof / ceiling including all accessories as required complete including GI metal flush doxes with modular frame / cover plate of suitable size for mounting modular switches / sockets etc., and PVC insulated multistranded FRLSH copper conductor 1.5 Sqmm single core cable |
| 14 | (green colour) as earth conductor and connecting to common earth dolly complete all as specified and directed for the following: - |
| 15 | One light point controlled by one switch two way type. |
| 16 | One ceiling fan / exhaust fan point controlled by one switch one way type. |
| 17 | One 3 pin 5/6 Amps socket outlet point on same board. |
| 18 | One 3 pin 5/6 Amps socket outlet point on independent board. |
| 19 | All as per Sl item No. 12 above but with 2.5 Sqmm copper conductor FRLSH (multistrand), 1100 volts grade PVC insulated, ISI marked unsheathed cable in and including concealed PVC conduit, heavy duty, ISI marked, medium grade with valid CML No. not less than 25mm dia with all fitting & accessories as required and including PVC insulated ISI marked, unsheathed, FRLSH copper conductor cable of size 2.5 Sqmm (green colour) as earth wire to common earth dolly for one three pin socket outlet 15 Amps. |
| 20 | S&F, modular switch one way, 6 Amps, one module complete all as specified and directed. |
| 21 | S&F, modular switch two way, 6 Amps, one module complete all as specified and directed. |
| 22 | S&F, modular switch 6 Amps 2/3 pin, two module complete all as specified and directed. |
| 23 | S&F, modular switch one way, 16 Amps, one module complete all as specified and directed. |
| 24 | S&F, modular switch 6/16 Amps, 2/3 pin, two module complete all as specified and directed. |
| 25 | S&F, ceiling rose 3 terminals / PVC / polycarbonate, isolated body complete all as specified and directed. |
| 26 | S&F, modular stepped type electronic fan regulator 120W complete all as specified and directed. |
| 27 | S&F, 50mm dia x 1.5m long GI pipe (medium class) bracket for mounting of security light fitting on pole including bending the pipe to the required shape 02 Nos 40mm x 3mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and paint complete all as specified and directed. |
| 28 | M&L for PVC conduit medium grade, concealed type not less than 25mm dia including all accessories as required in installation for laying existing LAN / CAN / TV / Internet cables of any type complete all as specified and directed.Note: (i) Cutting in chases and pointing in brick wall / stone wall shall be done by contractor without any extra cost.(ii) Making good of disturbed surfaces matching with existing finishes shall be done by contractor without any extra cost. |
| 29 | S&F, BLDC ceiling fans 1200mm sweep complete with blades, down rods of adequate length (not less than 300mm) with electronic regulator and accessories 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00, BEE five star rated with Brushless Direct Current motor (BLDC), white colour complete including making electric connection by providing 1.0 Sqmm x 3 core flexible sheathed copper cable from ceiling rose / source to fan connector complete all as specified and directed. |
| 30 | S&F, heavy duty industrial wall fan (steel body), air circulator of 450mm sweep with single phase suitable for 230 volts, 50 Hz, 1440 RPM, air delivery shall not be less than 24000 CMM, 250 Watt, wall mounted, 3 blade and connecting up complete including making connection by providing 1.5 Sqmm x 3 core flexible sheathed copper cable from ceiling rose to connector of fan including all accessories complete all as specified and directed. |
| 31 | S&F, DB box in sheet metal enclosure MCB DB 4 way TPN double door, factory made suitable for MCB as incomer and suitable for SP/TP DB in outgoing, enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK 09, as per IEC 61439-3, 415 volts, including blanking plate etc., DB box to be flush and fixed in concealed in wall complete including taking down the existing DB of any type and size along with its accessories by removing from existing circuits and refixing the new DBs and circuits complete as required at site complete all as specified and directed. |
| 32 | S&F, DB box in sheet metal enclosure MCB DB 6 way TPN double door, factory made suitable for MCB as incomer and suitable for SP/TP DB in outgoing, enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK 09, as per IEC 61439-3, 415 volts, including blanking plate etc., DB box to be flush and fixed in concealed in wall complete including taking down the existing DB of any type and size along with its accessories by removing from existing circuits and refixing the new DBs and circuits complete as required at site complete all as specified and directed. |
| 33 | S&F, 63A rating, 4 pole, 415 V, MCCB in the existing MCCB DB complete with connections, testing and commissioning as required complete all as specified and directed. |
| 34 | M&L for earthing with galvanised steel earth plate electrode 600 x 600 6mm thick buried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m below normal ground level connected to GI wire 4mm by means of nuts, bolts, check nuts, washers of galvanised iron or steel all as shown in electrical plate No. 03 of SSR Part-I connected to earthing test point including excavation / earth work in any type of strata, removal of surplus excavated material, GI pipe for watering and funnel, PCC 1:3:6 type C1 chamber including necessary formwork / mould for fair and even |
| 35 | surfaces, precast RCC 1:2:4 type B0 chamber cover slab, GI funnel with GI watering pipe 20mm bore medium grade, wire mesh, protection pipe 40mm bore, charcoal and salt, GI pipe light grade for earth lead upto 7.50m long including testing complete all as specified and directed.Note: GI wire beyond 7.5m will be measured and paid separately. |
| 36 | Providing and laying GI wire 4mm from earth electrode directly in ground complete all as specified and directed. |
| 37 | S&F, exhaust fan steel body AC single phase 230V of size 300mm sweep with blades and frame and louvers including making opening brick / stone masonry wall as per requirement of exhaust fan and make good and matching with existing surfaces complete all as specified and directed. |
| 38 | INTERNAL WATER SUPPLYS&F, chromium plated two way bib cock complete all as specified and directed. |
| 39 | S&F, chromium plated pillar cock auto closing system complete all as specified and directed. |
| 40 | PATH / HARDSTANDINGForming 12mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, grade 'A' thick of slab 100mm complete all as specified and directed. |
| 41 | SEWAGE DISPOSALM&L for cement concrete 1:3:6 type C2 aggregate laying concrete bed to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested in; complete all as specified and directed. |
| 42 | Providing and laying non-pressure NP2 class (light duty) 150mm dia R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints complete all as specified and directed. |
| 43 | FENCING AND GATEM&L, Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for holding chain link fencing and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 44 | M&L for painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 45 | EXTERNAL WATER SUPPLYExcavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out and getting out in soft soil for GI/CI pipes complete all as specified and directed. |
| 46 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out and getting out in hard / dense soil for GI/CI pipes complete all as specified and directed. |
| 47 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out and getting out in disintegrated rock for GI/CI pipes complete all as specified and directed. |
| 48 | Returning filling in trenches including spreading levelling watering and well ramming in layers not exceeding 25cm complete all as specified and directed. |
| 49 | Removing of surplus soil and depositing to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 50 | M&L for galvanized iron water tubing medium grade 40mm ISI marked in trenches complete with all accessories such as tees union, bend, elbow nipple reducer etc., all as required at site for branch connection including cutting threading complete all as specified and directed. |
| 51 | M&L for galvanized iron water tubing medium grade 20mm ISI marked in trenches complete with all accessories such as tees union, bend, elbow nipple reducer etc., all as required at site for branch connection including cutting threading complete all as specified and directed. |
| 52 | S&F, gun metal gate / globe valve with iron wheel head screwed both ends for iron pipe, 40mm dia complete all as specified and directed. |
| 53 | S&F, gun metal gate / globe valve with iron wheel head screwed both ends for iron pipe fixed 20mm dia complete all as specified and directed. |
| 54 | EXTERNAL ELECTRIFICATIONSupply, laying, testing & commissioning of LT underground cable 3.5 Core x 120 Sqmm, 1100 volts grade, XLPE insulated and PVC sheathed, heavy duty armoured with multistranded aluminium conductors, IS-7098 marked, laid in trenches / ducts / fixed on poles / walls / laid under roads / paths / drain / culverts or encased in GI pipe complete all as specified and directed Please Enable Macros to View BoQ information |
| 55 | EXTERNAL ELECTRIFICATIONSupply, laying, testing & commissioning of LT underground cable 3.5 Core x 120 Sqmm, 1100 volts grade, XLPE insulated and PVC sheathed, heavy duty armoured with multistranded aluminium conductors, IS-7098 marked, laid in trenches / ducts / fixed on poles / walls / laid under roads / paths / drain / culverts or encased in GI pipe complete all as specified and directed Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 32 daysAug 31, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 35 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender