Tender For Repair, Maintenance Of Security Lights, Flood Lights And Connected Items At Sec - I At Ge Devlali
Tender Value
75.10 Lakhs
Estimated cost
Bid Submission
22 Aug 2026
26 days left
EMD
1.38 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Nashik → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair, Maintenance Of Security Lights, Flood Lights And Connected Items At Sec - I At Ge Devlali
BOQ
| Sl. No. | Item Description |
| 1 | Supply, Laying, jointing and testing in replacement of LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable ISI marked, laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizes and aluminium lugs for connection complete all as specified and directed of following sizes:- a) 4 core 10 sqmm |
| 2 | b) All as per item No.1 here in before but of size 4 core 16 sqmm |
| 3 | c) All as per item No.1 here in before but of size 2 core 10 sqmm |
| 4 | d) All as per item No.1 here in before but of size 4 core 25 sqmm |
| 5 | e) All as per item No.1 here in before but of size 3.5 core 35 sqmm |
| 6 | f) All as per item No.1 here in before but of size 3.5 core 50 sqmm |
| 7 | g) All as per item No.1 here in before but of size 3.5 core 70 sqmm |
| 8 | Taking down existing defective LT under ground cable of any size from trenches complete all as directed |
| 9 | Excavation in trenches n.exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and electric pole as per specification and getting out in soft/loose soil complete all as specified and directed. |
| 10 | Supply & lay in trenches double walled corugated HDPE pipe 50 mm dia high density for protection of under ground cables (Note: pipe couplers with seal, bends, end covers etc are deemed to be included in rate quoted) |
| 11 | Supply & lay in trenches double walled corugated HDPE pipe 70 mm dia high density for protection of under ground cables (Note: pipe couplers with seal, bends, end covers etc are deemed to be included in rate quoted) |
| 12 | Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n.exc. 25 cm thick complete all as specified and directed |
| 13 | Removing of excavated soil to a distance n.exc. 50 mtr from starting point and deposited where directed at a level not exceeding 1.5 mtr above the starting point including spreadind complete all as specified and directed. |
| 14 | Taking down defective street light fittings of any type and any wattage for Inspection / checking /finding faults /repairs/replacement of parts, including thorough cleaning of acrylic perpex cover and refixing the same in existing position after carrying out necessary repair/replacement of parts, complete including testing etc for smooth functioning all as specified and directed. Note :- (i) Repair/replacement of parts (after taking down fitting) required will be measured and paid separately in relevent items of schedule as supply and fixing |
| 15 | M & L in replacement for bracket made out of GI tubing 40 mm dia, light grade 1.5 mtr long including fixing with MS clamps -2 Nos made out of 40 mm wide 4 mm thick flat iron with M.S nuts bolts 75 mm long 12 mm dia -4 Nos with flat washer (3mm thick) -02 No for each including painting with aluminium paint over one coat of red oxide to the M.S clamps & bracket etc complete all as directed at site. |
| 16 | Supply & fixing in replacement Driver for 120 Watt LED street light fitting of Model No Endura City Liner Neo, Make Havells or any other techno commercial equivalent make as approved by GE |
| 17 | Supply & fixing in replacement Driver for 72 Watt LED street light fitting of Make Havells/Bajaj/ Crompton |
| 18 | S&F supply and fix in repair PVC insulated stranded unarmoured Copper conductor cable 1.0 Sqmm flat/ round three core 1100 volts grade for street light complete all as specified and directed |
| 19 | Taking down of High masts light and other defective items (like-motor, control panel junction box etc) refixing it after replacing /repairing, all as specified and directed. |
| 20 | Supply and lay in replacement 40 mm bore GI tubing light grade, ISI marked, for cable protection at road crossing/floor/wall/ on poles or at any indicated situation etc duly sealed at both end after drawing cable including necessary clamps,saddels etc complete all as specified and as directed. |
| 21 | M & L for cement concrete 1:3:6 type C-2 using 40 mm graded aggregate incl necessary form work for coping of poles etc all as specified and directed. |
| 22 | M&L for cement concrete 1:4:8 type D-2 using 40 mm graded aggregate as in foundation for pole including necessary form work all as specified and directed |
| 23 | Taking down old us poles any type & Supplying, install and erect in true vertical position steel tubular swaged welded pole in replacement complete with cast iron/MS base plate 6mm thick and of size 300x300mm, finial taper, pole cap, bolts, nuts, washers & screws etc. pole made out of ERW M.S. tubing conforming to IS-2713 part-II type 410 SP-31 (9.0 metre long) LT including of holes of reqd Nos and size for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embedded in concrete, painting pole No the black paint by stenciled letters /figures of 8 cm height complete all as specified and directed by Engr-in-charge. (Note: Excavation and PCC works will be measured and paid separatly in respective items.) |
| 24 | Excavation in trenches n. exc. 1.5 mtr in wide and exc. 1.5 mtr in depth for steel tubular pole and getting out in soft/loose soil complete all as specified and directed. |
| 25 | M&L in replacement Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or sizes as indicated or directed and inclusive of one primer coat and two coats of alluminium paint complete all as specified and directed. |
| 26 | M & L for scrubbing out old paint, rust etc from 9 Mtr long pole and making smooth and even suface then painting with one coat of anti rust paint and two coats of superior quality aluminium paint on entire exposed portion of pole structure including all fitments on pole and writing pole number with 2'' size with white paint lettering on black base all as directed at site. (work shall be completed in the stipulated period as directde by Engr -in -charge ). |
| 27 | S&F in replacement new Endura cityliner Neo 70/72 Watt LED Luminaries lense embaded PC cover with high power LED as light source of 70W with10 KV built in surg protector, IP 66 protection and impact resistance of IK07. (suitable for pole/bracket dia 54 mm) Make Havells Cat Part Num:-ENDURACITYLINERNEOSL70WLED 757PASYBOTG or Equivalent model in Wipro/ Philips/ Crompton/Surya |
| 28 | S&F in replacement new Endura cityliner Neo 60 Watt LED Luminaries lense embaded PC cover with high power LED as light source of 60W with10 KV built in surg protector, IP 66 protection and impact resistance of IK07. (suitable for pole/bracket dia 54 mm) Make Havells Cat Part Num:-ENDURACITYLINERNEOSL60WLED 757PASYBOTG or Equivalent model in Wipro/ Philips/ Crompton/Surya |
| 29 | S&F in replacement new Endura cityliner Neo 120 Watt LED Luminaries with high power LED as light source of 120W with10 KV built in surg protector, IP 66 protection and impact resistance of IK07. (suitable for pole/bracket dia 54 mm) Make Havells Cat Part Num:- ENDURAPEARLMAGSL120WLED 757PASYTOTGASTHO or Equivalent model in Wipro/ Philips/ Crompton/ Surya |
| 30 | S&F in replacement Energy saving, environment friendly & robust IP 65 protected 80 Watt LED midbay with PDC housing suitable for ceiling (Surface/Suspended) mount & in Wide beam optics. Make- Havells model - ILIOSBAYPLUSHBP80WLED857SP90DTOPC/ or equivalent of Wipro/ Philips/Compton/Surya |
| 31 | S & F in replacement Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 flood light, 200 Watt suitable for highlighting architectural facade and general purpose lighting. Make- Havells, Model - JETAVALOURFL200WLED757MODNBLTG or Equivalent of Wipro/ Bajaj/ Crompton |
| 32 | Supply & fix in replacement Thermo plastic street light sintex box of size 280 X 170 X 130 mm Cat No GS-JB-2817 top Hinged (or equivalent make of National) wiith 4 way connector mounted on epoxy insulators for looping of cable for 3 Phase and 1 neutral fixed on pole with the help of MS nuts bolts and MS clamps-1 Nos of size 40 mm X 4 mm thick with one No MCB SP 6 Amp capacity mounted on din rail inside box. |
| 33 | Supply & fix in replacement Thermo plastic street light sintex box of size 280 X 170 X 130 mm Cat No GS-JB-2817 top Hinged (or equivalent make of National) wiith MCB TPN 32 Amps for looping of cable for 3 Phase and 1 neutral fixed on pole with the help of MS nuts bolts and MS clamps-1 Nos of size 40 mm X 4 mm thick with one No MCB SP 6 Amp capacity mounted on din rail inside box. |
| 34 | S &F in replacement Astronomical time switch model L&T GIC Astro Mini T2DDT7, 240 Volts DIN Mounting suitable for street light auto On-Off circuit Make L&T or equivalent of Siemens/ Legrand |
| 35 | S &F in replacement 3 Phase 32 Amps contactor 415 Volts coil votage AC supply suitable for street light auto On-Off circuit Make L&T, Model - MNX-32 or eqivalent of Siemens/ Legrand |
| 36 | S &F in replacement 3 Phase 50 Amps contactor 415 Volts coil votage AC supply suitable for street light auto On-Off circuit Make L&T, Model - MNX-50 or eqivalent of Siemens/ Legrand |
| 37 | Supply and fix in replacement coil (CS94192) of voltage 415 coil voltage suitable for contactor MNX50/70/80 of make L&T |
| 38 | Supply and fix in repair MCB TPN 32 Amps, 240 volts complete all as specified and as directed. |
| 39 | Supply and fix in replacement MCB TPN 63 Amps, 240 volts complete all as specified and as directed. |
| 40 | Supply, fix, test & commissioning in replacement of LT weather proof panel board powder coated out door type double door shutter type made out of CRCA 3.15 mm thick outer and 1.6mm thick for inner door confirming to IS 8623 with angle iron 50x50x6 mm outdoor, floor mounting type with closed bus bar, chamber and with aluminium bus bar of cap 200 Amp with necessary insulator suitable for 3 phase, 4 wire 50 Hz AC supply as per CPRI approved including provn of digital ammeter 0-500A, digital voltmeter 0-500Volts, CT's of suitable ratio, indicator lamps R-Y-B, selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc all as specified and directed with the following Work also includes provision of suitable size of cable glands, cable lugs, nut, bolts, washers etc.The bottom portion of enclosure shall be minimum 30 cm above ground level of legs of angle iron) Consisting of following accessories :- a) Aluminium bus bar capacity 200 Amps for Phase-R-Y-B-3 Nos & 150 Amps for neutral -1 No, Neutral link-01 Nob) MCCB TPN 25 KA, 63 Amp - 1 No (I/C) c) MCB SP 16 Amps - 06 Nos d) Astronomical timer suitable for street light control as per sunrise and sun set with 32 Amps MNX 32 contactor ( L&T) 3 Phase, 415 Volt - 0 1 Set |
| 41 | Supply and fix, test, commissioning of LT weather proof Feeder pillar and Timer panel board powder coated out door type double door shutter type made out of CRCA 3.15 mm thick outer and 1.6mm thick for inner door confirming to IS 8623 with angle iron 50x50x6 mm outdoor, floor mounting type with closed bus bar, chamber and with aluminium bus bar with necessary insulator suitable for 3 phase, 4 wire 50 Hz AC supply as per CPRI approved including provn of digital ammeter 0-500A, digital voltmeter 0-500Volts, CT's of suitable ratio, indicator lamps R-Y-B, selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc all as specified and directed with the following Work also includes provision of suitable size of cable glands, cable lugs, nut, bolts, washers etc (The bottom portion of enclosure shall be minimum 60 cm above ground level of legs of angle iron & depth of the panel should not be less than 45cm) a) Aluminium bus bar of capacity 300 Amps for Phase-R-Y-B & 150 Amps for neutral -1 No b) MCCB 4 Pole 36 KA , 160 Amp - 1 No (I/C Main)c) MCCB 4 Pole 25 KA , 100 Amp - 1 No Out going )d) MCB TPN 63 Amp 10 KA - 2 Nose) MCB TPN 40 Amp 10 KA -1 No f) Astronomical timer suitable for street light control as per sunrise and sun set with 32 Amps MNX 32 contactor (L&T) 3 Phase, 415 Volt - 0 1 Set |
| 42 | S &F in replacement Automatic street light switch using NATURE SWITCH for automatic switching of street Lights based on LUX level of Natural Light. The sensor (Nature Switch) along with suitable Power Contactor, MCB and Support Terminals should be enclosed in pole/ wall mountable enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade special moulding compound (Sintex make SMC Junction box) conforming to IP54 degree of ingress. The contactor, MCB and Circuit wiring should suitable enough to take load of 12 KW equally distributed over 3 Phase (4KW /Phase). Model No- 02EC12KW3P, Contactor Rating : 40 Amps (AC3), MCB (single-pole) Rating :63 Amps 3 Nos. Make : Nature Switch : Kakatiya Energy Systems Pvt Ltd Hyderabad or Equivalent of Bajaj /L&T/Legrand |
| 43 | Supply and fix in replacement MCCB 63 Amps 25 KA 4 Pole all as specified and as directed |
| 44 | Taking down old us poles of any type & supply, install & erect in true vertical posision galvanised steel octagonal poles 7 meter long with side mounted decorative type single arm bracket for mounting street lights of 3 mm thick sheet, bottom dia 130 mm and top dia 70 mm finial tapered complete with MS base plate of size 220mmx220mmx12mm, foundation bolts, nuts, washers & screws.The poles shall be hot dip galvanized as per relevant Indian standards with average coating thickness of minimum 70 micron. the material of pole HT Steel Conforming to grade S355JO & that of base plate is Fe 410 conforming to IS 226 / IS 2062. The Octagonal Poles shall be in single section. There shall not be any circumferential weld joint. Pole drawing along with details of base plate, foundation bolts and foundation details (RCC) shall be submitted along with pole. (Note: excavation, RCC foundation as per manufacturer drawing & specification, foundation bolts with nut & washers, Decorative type single arm for mounting street light, connector block for 3phase+ 1nutral for cable termination & MCB SP 10 Ams & pole cap is deemed to be included in rate quoted) |
| 45 | Taking down old u/s poles of any type & supply, install & erect in true vertical posision galvanised steel octagonal poles 8 meter long with side mounted decorative type single arm bracket for mounting street lights of 3 mm thick sheet, bottom dia 130 mm and top dia 70 mm finial tapered complete with MS base plate of size 220mmx220mmx12mm, foundation bolts, nuts, washers & screws.The poles shall be hot dip galvanized as per relevant Indian standards with average coating thickness of minimum 70 micron. the material of pole HT Steel Conforming to grade S355JO & that of base plate is Fe 410 conforming to IS 226 / IS 2062. The Octagonal Poles shall be in single section. There shall not be any circumferential weld joint. Pole drawing along with details of base plate , foundation bolts and foundation details (RCC) shall be submitted along with pole. (Note: excavation, RCC foundation as per manufacturer drawing & specification, foundation bolts with nut & washers, Decorative type single arm for mounting street light, connector block for 3 phase+ 1 neutral for cable termination & MCB SP 10 Ams & pole cap is deemed to be included in rate quoted) |
| 46 | M&L earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6.0 mm thick, and with GI Strip burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 32 x 6 mm size by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified.Note: The unit rate includes earth strip and protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point. |
| 47 | All as item No 46 above but earthig using 25x4mm size GI strip all as specified and as directed. |
| 48 | Supply and fix in replacemet of tri-colour LED strip in existing optical fibre poles, LED strip 18 meter long (orange+ white+ green in single strip) with driver operating on 230 volt, 50 Hz AC supply all as specified and directed. (Note-taking down existing optical fibre pole of 7 meter long and refixing the same after installation of LED strip is deemed to be included in rate quoted) Make: Philips/Havells/bajaj/Wipro |
| 49 | Cutting through existing bituminous road /PCC/floor/approx size width 50cm X 60cm depth along cross section of the road for laying of GI tubing/RCC pipe/HDPE pipe for encasing of cable and repairing the road to match with the original finish complete all as specified. |
| 50 | Supply and lay in replacement 80 mm bore GI tubing light grade, ISI marked, for cable protection at road crossing/floor/wall/ on poles or at any indicated situation etc duly sealed at both end after drawing cable including necessary clamps,saddels etc complete all as specified and as directed. |
| 51 | Supply,install, testing & commissioning of factory made LT panel wall mounted board made out of CRCA sheet 2 mm thick indoor type toltally enclosed weather, dust and vermin proof compartment type with front hinged door and locking arrengement mounted on M S flat iron clamp welded to panel body duly grouted on wall 415 V, 3 phase, 4 wire AC, 50 Hz having aluminium bus bar 160 Amps for phase-03 Nos & neutral- 01 No with 02 Nos Earth Terminals. insulated with PVC sleeves, space for fixing single phse KWH Energy meter 12 Nos 120x120x6 mm size angle iron hold fast, fastener bolts, copper lugs, spacers channels, rubber gaskets, locking knob, hylem sheet piece, PVC shrinkable sleeves, nut and bolts, washers etc suitable single core copper wire connectors, suitable compartments and epoxy power spray paint with primer complete all as specified including the following accessories including taking down old unservicable LT panel board INCOMING- a) MCCB 415 V 4 POLE 18 KA breaking capacity of 63 Amps- 01 No b) R-Y-B phase LED indicating lamp-03 Nos OUTGOING- a) MCB SPN 32Amps, 230V, 10 KA, C curve - 05 Nos b) Providing space for and refixing existing single phase KWH electric enery meter-04 Ns c) Copper wire 6 Sqmm wire and open terminals for all meters totaly pre wired. d) Glass windows for all meter for taking meter reading Note:- 1. Cost of taking down electric meters from old unserviceable penel board keeping in safe custody and refixing the same electric meters in new panel is deemed to be included in rate quoted. |
| 52 | Supply and fix , test , commissioning of LT weather proof panel board powder coated out door type double door shutter type made out of CRCA 3.15 mm thick outer and 1.6 mm thick for inner door confirming to IS 8623 with angle iron 50x50x6 mm outdoor, floor mounting type with closed bus bar, chamber and with aluminium bus bar with necessary insulator suitable for 3 phase, 4 wire 50 Hz AC supply as per CPRI approved including provn of digital ammeter 0-500A, digital voltmeter 0-500Volts, CT's of suitable ratio, indicator lamps R-Y-B, selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc all as specified and directed with the following Work also includes provision of suitable size of cable glands, cable lugs, nut, bolts, washers etc (The bottom portion of enclosure shall be minimum 40 cm above ground level. legs & depth of the panel should not be less than 45cm).Legs of angle iron should be 100 cm lenth (60 cm below ground and 40 cm above the eground) a) Aluminium bus bar of capacity 400 Amps for Phase-R-Y-B & 200 Amps for neutral -1 No b) MCCB 4 Pole 36 KA , 250 Amp - 1 No (I/C) c) MCCB 4 Pole 30 KA, 63 Amp - 5 Nos |
| 53 | All as item No 52 above but with following accessories:- a) Aluminium bus bar of capacity 200 Amps for Phase-R-Y-B & 100 Amps for neutral -1 No b) MCCB 4 Pole 36 KA , 160 Amp - 1 No (I/C)c) MCB TPN 63 Amp ,10 KA - 4 Nos (O/G) d) MCB SPN 32 Amps-02 (O/G) |
| 54 | All as item No 52 above but with following accessories:- a) Aluminium bus bar of capacity 400 Amps for Phase-R-Y-B & 200 Amps for neutral -1 No b) MCCB 4 Pole 36 KA 250 Amp - 1 No (I/C)c) MCCB 4 Pole 36 KA 160 Amp - 1 No (O/G)d) MCCB 4 Pole 25 KA 63 Amp - 4 Nos (O/G) |
| 55 | Fixing only, 4 meter cast iron decorative street light pole (CAT REF:- SDP 4M ZYLO SOB E17) in replacement of U/S decorative CI/Steel tubular/Octagonal pole.a) Rate of foundation for pole as per OEM drawings are deemed to be included in rate quoted.b) Rate of bottom mounted inverted light is also included in rate qouted. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 26 daysAug 29, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 33 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender