Tender For Provision Of Security Wall And Watch Tower In Newly Acquired Land To Enclose Areas At Nmrl Ambernath
Tender Overview
Project Description
Tender for Provision Of Security Wall And Watch Tower In Newly Acquired Land To Enclose Areas At Nmrl Ambernath
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 27-Aug-2026 | REVISED PRE-PRICED SCHEDULES | Other | 11-Sep-2026 |
| 2 | 27-Aug-2026 | AMENDMENT TO TENDER DOCUMENTS, REVISED PRE-PRICED SCHEDULES AND EVISED BOQ | BOQ | 11-Sep-2026 |
| 3 | 27-Aug-2026 | REVISED CRITICAL DATES_1 | Date | 11-Sep-2026 |
| 4 | 21-Aug-2026 | REVISED CRITICAL DATES | Date | 04-Sep-2026 |
| 5 | 21-Aug-2026 | REVISED CRITICAL DATES | Date | 04-Sep-2026 |
| 6 | 04-Sep-2026 | REVISED PREPRICED SCHEDULES_1 | Other | 18-Sep-2026 |
| 7 | 04-Sep-2026 | AMENDMENT TO TENDER DOCUMENTS AND REVISED BOQ_1 | BOQ | 18-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Schedule 'A' Part - IBUILDINGS & STRUCTURESThis Schedule contains Sl item No. 1.01 which is not prepriced by MES and the prepriced rate indicated in Col - 5 as `0.00 indicates this fact only. The tenderer is required to quote their rates in Column 6. |
| 2 | Lumpsum price worked out by the contractor for Construction of Watch Tower, ground + 2 storeys in RCC framed structure with RCC roof including all fittings and fixtures complete all as specified and as shown on drawings. |
| 3 | Lumpsum price worked out by the Contractor for \\"SITE CLEARANCE AND DEVELOPMENT” as listed in Schedule ‘A’ Part - II representing _______% ___________ percent Above / Below the lumpsum price of `12,86,979.14 inserted by the MES in Schedule ‘A’ Part - II |
| 4 | Lumpsum price worked out by the Contractor for “ PATH / HARDSTANDING” as listed in Schedule ‘A’ Part - III representing _______% __________________ percent Above / Below the lumpsum price of `16,48,422.22 inserted by the MES in Schedule 'A' Part - III |
| 5 | Lumpsum price worked out by the Contractor for “SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part - IV representing __________ % ___________________ percent Above / Below the lumpsum price of `66,466.60 inserted by the MES in Schedule ‘A’ Part - IV |
| 6 | Lumpsum price worked out by the Contractor for “FENCING / COMPOUND WALL / GATE” as listed in Schedule ‘A’ Part - V representing _______ % _______________ percent Above / Below the lumpsum price of `2,54,63,771.36 inserted by the MES in Schedule ‘A’ Part - V |
| 7 | Lumpsum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - VI representing ______% _______________________ percent Above / Below the lumpsum price of `22,379.80 inserted by the MES in Schedule ‘A’ Part - VI |
| 8 | Lumpsum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - VII representing __________% _______________ percent Above / Below the lumpsum price of `74,621.00 inserted by the MES in Schedule ‘A’ Part - VII |
| 9 | Lumpsum price worked out by the Contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - VIII representing __________ % _____________________ percent Above / Below the lumpsum price of `74,545.83 inserted by the MES in Schedule ‘A’ Part - VIII |
| 10 | Lumpsum price worked out by the Contractor for “EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - IX representing ______ % _________________ percent Above / Below the lumpsum price of `37,924.00 inserted by the MES in Schedule ‘A’ Part - IX |
| 11 | Schedule 'A' Part - XThis Schedule is not prepriced by MES and the prepriced rate indicated in Col - 5 as `0.00 indicates this fact only. The tenderer is required to quote their rates in Column 6. This Schedule constitutes Sl. Item Nos. 11 to 41 |
| 12 | SEWAGE DISPOSALS&F, septic tanks 10 users of LLDPE type complete all as specified and directed. |
| 13 | FENCING / COMPOUND WALL / GATES&F, galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails / post straing bolts, including securing or typing at crossing with and provision of galvanised mild steel wire, staples or steel pins etc (each line of wire to be measured) complete all as specified and directed. |
| 14 | INTERNAL ELECTRIFICATIONS&F, LED decorative box type light fitting 1 x 20W, 4 ft, 220V, with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 15 | S&F, LED decorative box type light fitting 1 x 9/10 W, 2 ft, 220 V, with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 16 | S&F, LED street light fittings 35watt, 230volts, outdoor type high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP-66 protection and GI pipe 1.5m bend to shape to fix in wall through proper clamps, nuts, bolts with washers connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 17 | S&F, exhaust fan, 250mm sweep made of sturdy engineering plastic complete with louvers shutter, voltage 230 volts, 50Hz, 1200 RPM, copper wire complete all as specified and directed. |
| 18 | S&F, electric water heater, storage type steel body with inner tank and heating element upto 2KW capacity 25 litres BEE 5 star rated complete with all accessories such as safety valve, thermostat, NRV, connection pipes etc., complete all as specified and directed. |
| 19 | EXTERNAL WATER SUPPLYConstruction of valve chamber of size 1000mm x 1000mm x 1000mm with PCC solid block masonry 15mm thick PCC foundation 1:4:8, type D2 and 15cm thick hardcore, 200mm thick PCC solid block masonry built in CM 1:6, 15mm thick internal and external plaster CM 1:4, 10 SWG thick MS sheet cover including 40 x 40 x 6mm MS angle frame fixed in coping in PCC 1:2:4, type B1 with locking arrangement and painting with one coat of red oxide and two coat of black bituminous paint complete all as specified and directed. |
| 20 | EXTERNAL ELECTRIFICATIONSupply, laying & testing, cable XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35sqmm 4core complete all as specified and directed. |
| 21 | Supply, laying & testing, cable XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16sqmm 4core complete all as specified and directed. |
| 22 | Supply, laying & testing, cable XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10sqmm 2core complete all as specified and directed. |
| 23 | Excavating in trenches not exceeding 1.5m wide and exceeding 1.5m in depth for taking out / laying of LT under ground cables and getting out in soft soil type of earth strata complete all as specified and directed. |
| 24 | Excavating in trenches not exceeding 1.5m wide and exceeding 1.5m in depth for taking out / laying of LT under ground cables and getting out in hard soil type of earth strata complete all as specified and directed. |
| 25 | Excavating in trenches not exceeding 1.5m wide and exceeding 1.5m in depth for taking out / laying of LT under ground cables and getting out in disintegrated rock type of earth strata complete all as specified and directed. |
| 26 | Excavating in trenches not exceeding 1.5m wide and exceeding 1.5m in depth for taking out / laying of LT under ground cables and getting out in hard rock type of earth strata complete all as specified and directed.Note: Blasting is prohibited. |
| 27 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm in soil complete all as specified and directed. |
| 28 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm in soft / disintegrated rock complete all as specified and directed. |
| 29 | Removing surplus excavated rock to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 30 | M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 31 | Supplying & laying, reinforced precast concrete cable cover but class LV, type I, flat, size 250mm x 150mm x 40mm for cable protection complete all as specified and directed. Please Enable Macros to View BoQ information Compatibility Report for BOQ_89100 corrected by me.xls Run on 5/17/2020 18:00 The following features in this workbook are not supported by earlier versions of Excel. These features may be lost or degraded when opening this workbook in an earlier version of Excel or if you save this workbook in an earlier file format. Significant loss of functionality # of occurrences Version Any effects on this object will be removed. Any text that overflows the boundaries of this graphic will appear clipped. 3.0 Excel 97-2003 One or more cells in this workbook contain data validation rules which refer to values on other worksheets. These data validation rules will not be saved. 4.0 Excel 97-2003 Minor loss of fidelity Some formulas in this workbook are linked to other workbooks that are closed. When these formulas are recalculated in earlier versions of Excel without opening the linked workbooks, characters beyond the 255-character limit cannot be returned. 5Defined Names Excel 97-2003 One or more objects in this workbook such as shapes, WordArt, or text boxes may allow text to overflow the object boundaries. Earlier versions of Excel do not recognize this option and will hide overflowing text. 6.0 Excel 97-2003 |
| 32 | Supplying & laying, reinforced precast concrete cable cover but class LV, type I, flat, size 250mm x 150mm x 40mm for cable protection complete all as specified and directed. Please Enable Macros to View BoQ information Compatibility Report for BOQ_89100 corrected by me.xls Run on 5/17/2020 18:00 The following features in this workbook are not supported by earlier versions of Excel. These features may be lost or degraded when opening this workbook in an earlier version of Excel or if you save this workbook in an earlier file format. Significant loss of functionality # of occurrences Version Any effects on this object will be removed. Any text that overflows the boundaries of this graphic will appear clipped. 3.0 Excel 97-2003 One or more cells in this workbook contain data validation rules which refer to values on other worksheets. These data validation rules will not be saved. 4.0 Excel 97-2003 Minor loss of fidelity Some formulas in this workbook are linked to other workbooks that are closed. When these formulas are recalculated in earlier versions of Excel without opening the linked workbooks, characters beyond the 255-character limit cannot be returned. 5Defined Names Excel 97-2003 One or more objects in this workbook such as shapes, WordArt, or text boxes may allow text to overflow the object boundaries. Earlier versions of Excel do not recognize this option and will hide overflowing text. 6.0 Excel 97-2003 |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 3 daysCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 3 daysCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 3 daysCorrigendum-4 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-5 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-6 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 10 daysCorrigendum-7 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 10 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender