Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #56652423

Tender For Special Repair And Addl/Altn To Lt External Electric Services Against Job No.W/Srw/Electric Services/2025-26 Under Ge 861 Ews

Issued by Statutory Bodies & Commissions/Committees · Anantnag, Jammu and Kashmir
Tender Value
26.14 Lakhs
Estimated cost
Bid Submission
24 Aug 2026
0 days left
EMD
52500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Anantnag → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Special Repair And Addl/Altn To Lt External Electric Services Against Job No.W/Srw/Electric Services/2025-26 Under Ge 861 Ews

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 17-Aug-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 24-Aug-2026

BOQ

Name of Work:- SPECIAL REPAIR AND ADDL/ALTN TO LT EXTERNAL ELECTRIC SERVICES AGAINST JOB NO.W/SRW/ELECTRIC SERVICES/2025-26 UNDER GE 861 EWS
Sl. No. Item Description
1Excavating in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cable, pipes etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in Soft/ Loose soil complete all as specified and as directed by Engineer-in- charge.
2Excavating in trenches, not exceeding 1.5 mtr wide and exceeding 1.5 mtr and not exceeding 3.00mtr depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cable, pipes etc. not exceeding 10 sqm on plan and exceeding 1.5 mtr and not exceeding 3.00mtr depth and getting out in Soft/ Loose soil complete all as specified and as directed by Engineer-in- charge.
3Returning filling in, approved soft/loose soil, including spreading , levelling, watering and well ramming in layers, each layer not exceeding 25cm in any type of soil complete all as specified and as directed by Engineer-in- charge.
4Removing excavated material/soils to a distance not exceeding 50 mtr and depositing where directed at a level not exc.1.5 mtr above the starting point, complete all as spefied and as directed by Engineer-in-Charge.
5Material and Labour sand cushioning, with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and as directed by Engineer-in-Charge. (Note:- Punned thickness shall be considered for payment purpose)
6Material and Labour Bricks laid in trenches flat with width equal to length of brick for cable protection well burnt sub class 'B' laid across the complete all as specified and directed by Engineer-in-Charge.
7Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 35 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
8Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 25 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
9Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 70 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
10Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 95 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
11Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 120 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
12Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 150 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
13Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 16 Sqmm 2.00 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
14Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6 buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including earth continuity GI strip 32mm x 6mm (upto test point from earth plate i.e. 7.5m min) by means of GI bolts/nuts/washersand including protected by 15mm dia GI light grade protection pipe from earth plate to test point, including making of test point. Earth plate shall be surrounded by packed layer of char coal/coke & salt all around bottom and top with alternative layer. 20mm GI mediumt grade pipe for watering (should be 10cm above GL) and including socket, plug, funnel, wire mesh, RCC cover and (including steel for cover) PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil , returning filling and disposal of surplus soil to a distance not exceeding 50m, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and and as directed by Engineer-in-charge. Note:- (i) Earth continuity of GI wire 4 mm including protection pipe up to 7.5 mtrs from earth electrode will be included in unit rate, complete all as specified and directed. (ii) The rate of earth work in soft/loose soil i.e. excavation, returing filling and removal, form work is included in this item and nothing shall be paid extra on this account. (iii) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (iv) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
15Supply ,Fabricate, install, connect, test and commissioning of out door type LT electrical panel board, AC, 3 phase, 4 wire, 415 / 500 V, 50 Hz, outdoor type, fabricated with 3.15 mm thick made of CRCA, powder coated , CPRI Approved , Cable gand, bottom with detachable plates, front and rear with hinged type door and locking arrangements, chamber for cable entry and exit, chamber for aluminium bus bars with and including aluminium bus bars 4 Nos, 500 amps capacity insulated with colored PVC sleeves mounted on suitable insulators and separators, holes drilled for connections, complete suitable for mounting following switch gear items internally connected with suitable capacity aluminium strip/ rods insulated, complete mounted on PCC pillars complete all as specified and directed by Engineer-in-Charge and comprising of the followings:-INCOMING :-(a) MCCB 4 Pole, 415 V, adjustable thermal setting, 250 Amps with breaking capacity 36/35 KA - 01 No OUTGOING :- (b) MCCB 4 Pole, 415 V, adjustable thermal setting 63 Amps with breaking capacity 25 KA - 03 Nos.(c) MCCB 4 Pole, 415 V, adjustable thermal setting 100 Amps with breaking capacity 16 KA - 01 No. (d) MCB SPN 32 Amps, 230 Volt , 10 KA - 01 No. (e) Voltmeter, electronic, digital type, with selector switch 0 - 500 volts, AC, 50 Hz - 1 No. (f) Ammeter electronic, digital type, 0 - 400 amps, AC, 50 Hz - 1 No. (g) Current transformer200 / 5 amps rating, AC, 50 Hz - 3 Nos. (h) Phase indication LED lamps - 3 Nos(RYB). Note: Drawings of LT Panel shall be approved from GE before procuement .
16Supply & Fixing LED street light fitting 36 Watt 230 V AC outdoor type, energy saving and environment friendly light fitting with electronic geart housed with high pressure die cast aluminum housing LED street light luminaires complete all as per manufacturer's instructions , with IP66 protection with and including all accessaries complete all as specified and directed by Engineer-in-Charge. Notes:-(a) Contractor has to furnish a replacement warranty of 02 years for LED Light fittings complete including from the certifiy date of completion of CA. The product will be replaced free of cost in the following case :-(i) Manufacturing defects.(ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (b) All LED light must meet the provision laid down in IS - 16101, 16102 Part -I/II,16103 Part -I, 16104,16105,16106, 16108/2012 and 15885 Part -II / Section 13. (c) Scope of work shall include LED Light fittings walls/ceiling which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account. (d) cable for connection from Junction box to street light shall be measured and paid seperately under appropriate item of Schedule 'A' BoQ.(e) Street light bracket shall be measured and paid seperately under appropriate item of Schedule 'A' BoQ.
17Supply & Fixing Security light brackets made with 40mm dia light grade galvanised iron pipe 1.50mtrs long with 30° bend with and including flat iron clamps , nuts, bolts and washers to brace the same properly duly painted with two coats of silver coloured synthetic enamel paint over one coat of red oxide zinc chrome primer and complete all as specified and directed by Engineer-in-Charge.
18Supply & Fixing outdoor type SMC junction box of size 170mm x 170mm x 105mm one piece moulded SMC door hinged fixed base with hinged right or left side and fixed to the foundation pole with and including suitable fixing arrangement bus bar with single electrolytic aluminium for both phase and neutral supported on FRP insulator and cut out complete fixed on the pole with suitable inlet and outlet , provision for cable connection, with and icluding one no. MCB SP 6 Amps rating 'B' curve for controling the pole light including necessary connection, complete all as specified and directed by Engineer-in-Charge. Note: The rate of one no. MCB SP 6 Amps rating 'B' curve is included in this item and bidder shall quote his rate accordingly. Nothing shall be paid extra on this account.
19Supply and fixing 1.5 Sqmm x three core PVC insulated flexible copper conductor wire for street/security light terminal box, complete all as specified and directed by Engineer-in-Charge.
20Material & Labour for Steel tubular poles type 410 SP-31 (9.00mtr long) complete with cast iron base plate, finial, taper plug, bolts nuts & screws complete with and including internal surface of steel tubular pole through out and external surface up to planting depth shall be painted with bituminous paint and remaining external surface shall be treated with two coats of aluminium paint over a coat of red oxide zinc chromate primer complete and painting upto 1.5 mtr with alternate layer of yellow & black including marking Sr No of the poles all as specified. , with and including PCC 1:3: 6 Type C-1, using 20mm grade stone aggregates of size 0.60 mtr x 0.60mtr x 1.50 mtr , with and including coping in PCC 1:2:4 Type B-1 using 20mm grade stone aggregates of required size as directed by Engineer-in-charge , with and including two coats of cement base paint over and with including appropriate primer , with and including Earth work such as excavation,Returning Filling and removal complete all as specified and directed by Engineer-in-Charge. Note : The rate of bituminous paint , one coat of red oxide zinc chrome primer & two coats of aluminium paint upto 1.5 mtr , PCC 1:3: 6 Type C-1, using 20mm grade stone aggregates of size 0.60 mtr x 0.60mtr x 1.50 mtr , coping in PCC 1:2:4 Type B-1 using 20mm grade stone aggregates of required size , two coats of cement base paint over and with including appropriate primer ,Earth work such as excavation,Returning Filling removal is included in this item and bidder shall quote his rate accordingly. Nothing shall be paid extra on this account. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56652423
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 26.14 Lakhs
LAST DATE 24-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair And Addl/Altn To Lt External Electric Services Against Job No.W/Srw/Electric Services/2025-26 Under Ge 861 Ews
Basic Detail
Tender No GE 861 EWS-73(T)/2025-26
Bidding Type Tender
Location
City Anantnag
State Jammu and Kashmir
Key Dates
Publish Date 17 Aug 2026
Submission Date 24 Aug 2026
Open Date 26 Aug 2026
Finance
Tender Value 26.14 Lakhs
Tender Fee 500
EMD 52500
Exemption Not Available
Document List
82a5beb5-a875-4fe7-baf5-8001727d62fc.html
BOQ_874546.xls
credit73T.pdf
Tender73T.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 24, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Today
Aug 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Aug 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
html

82a5beb5-a875-4fe7-baf5-8001727d62fc.html

xls

BOQ_874546.xls

pdf

credit73T.pdf

pdf

Tender73T.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders