Defence Statutory Bodies & Commissions/Committees Closing in 13 days TDR #56652402

Tender For Special Repairs To Fire Station Bldg No. P-17 At Nad Sunabeda, Odisha Under Ge (P) (Navy) Visakhapatnam

Issued by Statutory Bodies & Commissions/Committees · Koraput, Odisha
Tender Value
36 Lakhs
Estimated cost
Bid Submission
13 Aug 2026
13 days left
EMD
72000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Koraput → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repairs To Fire Station Bldg No. P-17 At Nad Sunabeda, Odisha Under Ge (P) (Navy) Visakhapatnam

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 31-Jul-2026 BOQ corrigendum BOQ 13-Aug-2026

BOQ

Name of Work:- SPECIAL REPAIRS TO FIRE STATION BLDG NO. P-17 AT NAD SUNABEDA, ODISHA UNDER GE (P) (NAVY) VISAKHAPATNAM
Sl. No. Item Description
1SCHEDULE 'A PART-I (B/R WORKS)Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
2Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. laid, badded and pointed in any mortar complete all as per specified and direded.
3Demolition of brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as per specified and direded.
4Taking down chowkats of frames with shutters (without taking off shutters, from the frames) not exceeding 1.50 Sqm each and removing off the site complete all as per specified and direded.
5Taking down chowkats of frames with shutters (without taking off shutters, from the frames) exc 1.50 Sqm but n exc 4.0 sqm each and removing off the site complete all as specified and directed.
6M&L for brickwork with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
7M&L Non Skid joint free ceramic coloured tiles 7-8mm thick, area of each tiles exc 0.06 Sqm but n. exc 0.11 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 15 mm thick screed bedding in cement mortar 1:4 complete all as specified and directed.
8S&F glazed coloured ceramic tiles in vertical surface, as per approved design, size 300 X 450 X 7 mm or 350 X 250 X 7 mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles, laid over and incl 10mm thick bedding in cement mortar 1:4 complete all as specified and directed.
9M&L for vitrified ceramic tiles dark shade 10mm thick (square/ rectangular) polished area of each tile not exceeding 0.36 Sqm in floors etc set and joined in neat cement slurry and pointed in colored cement to match over 15 mm thick screed bed of cement mortar 1:4 complete all as specified and directed..
10M& L for Vitrified Ceramic tiles, dark shade, 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in vertical surfaces, set and jointed in neat cement slurry and pointed in white or colored cement to match including screed bed or bedding layers 10 mm thick in cement mortar (1:4) for laying floor finishes complete all as per specified and directed.
11S&F Pre-polished Machine cut kota stone slab flooring 18-20 mm thick over and including 15 mm thick screed base in cement mortar (1:4), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
12M&L for Pre-polished Machine cut kota stone as in skirting 20-25mm thick over and including 20 mm thick screed bed in cement sand mortar 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
13M&L for Granite (of any type) 20 mm thick work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15 mm thick screed bed in cement sand mortar 1:4 complete all as specified and as directed.
14M&L PCC 1:2:4 type B1 using 20 mm graded aggregate as in roof padding, roof kerbs or mud stops and including demolition & removal of demolished materials complete all as specified and directed.
15M&L for Roof Treatment including the following complete all as specified and as directed:-(i) Taking out of existing water proofing treatment by roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc.and brushing with neat cement slurry @ 3.00 kg of cement per Sqm and 30mm thick PCC padding.(ii) 10 mm thick plastering over PCC padding in CM 1:4 on surface mixed with WPC @ 2% by weight of cement as per manufacturers instructions.(iii) Cleaning of plastered surface and applying one coat of hot blown bituminous primer conforming to IS -3384 (latest) @ 0.5 Ltr / Sqm.(iv) APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by torch application complete all as specified. Polymeric membrane shall be taken to a height of 30 cm (minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing.(v) Applying one coat of bituminous aluminium primer over APP membrane @ 0.11 Lit / Sqm.Note:- (a) Primer, APP membrane & bituminous aluminium paint shall be of same manufacturer and executed through applicator authorised by the approved manufacturer only.(b) Membrane shall be laid with side overlap of 100 mm and end overlap of 150 mm as per manufacturers instruction.(c) PCC 30mm thick Padding & WPC will be measured and paid separately.
16Providing and fixing factory made uPVC white colour casement (Openable) Door made of extruded profile wilh wall thickness of 2.3mm ( + -0.2mm). Window profile with hollow section with multi chamber, frame (60mm x 58mm), sash (60mm x 78mm). T profile (One vertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling ol holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware.EPDM gasket 1.2 + -0.2mm thick galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27mm), T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall wilh 8mm x 100mm long fasteners. Hardware: [casement door handle made of zinc alloyed (white powder coated). Corner striker. Secondary Strikers. Cylinder. Door transmission gear made of mild sleel with multi point locking system with strikes. 3D Hinges of zinc alloyed (white powder coated) [and 5mm thick glazing with selected quality glass. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose.) complete all as per specified and directed.
17Providing and fixing factory made uPVC white colour Sliding window Three track with area n.exc 2.0 Sqm made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured lor payment purpose.) complete all as per specified and directed.
18Providing and fixing factory made uPVC white colour fixed window with Area exceeding 1.00 sqm but not exceeding 2.00 sqm each made of extruded profiles with wall thickness of 2.3mm(+-0.2mm). Window profile with hollow section with multi chamber. Frame (60mm x 58mm). T profile (Onevertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket. 1.2 +–0.2mm thick, galvanized steel Frame (28mm x 21.5mm), T profile (27mm x 17 mrn) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners- 5mm thick glazing with selected quality glass (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories Net opening will be measured for payment purpose.) complete all as per specified and directed.
19Supply and fixing factory made uPVC white colour fixed glazed window/ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.) comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge.(Glass shall be paid separately).Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
20Hacking out old broken glass (any thickness size quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones 4 mm thick sheet glass ordinary quality & glazing with oil putty or fitted with beads in squares n.exc.0.50 sqm in each pane complete all as specified and directed.
21S&F 4 mm thick figured glass, pin head type and glazing with oil putty or fitted with beads in squares n.exc. 0.50 sqm in each pane complete all as specified and directed.
22S&F Wire netting of stainless steel wire 1.4mm dia with size of mesh 12mm fixed with tinned tacks of stainless steel wire staples complete all as specified and directed.
23Supply only 5 mm thick sheet glass ordinary quality & glazing with oil putty or fitted with beads in squares exc.0.50 sqm in each pane complete all as specified and directed.
24S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin- charge.
25S&F in repair Door closer aluminium (extruded section body) hydraulically regulated, designation No.3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed.
26S&F of Mortice Lock of 4 Lever, vertical type of size 100mm made of Brass complete all as specified and as directed.
27S&F in repairs curtain rod of 18 mm dia mild steel, chromium plated with fixing brackets, stops, rollers etc, complete all as specified and directed.
28Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed.
29S&F Anodised aluminium snap grid frame work using T&L sections of size 610x610mm including cleats complete for false ceiling complete all as specified and directed.
30S&F Hangers 6mm dia G.1 (Upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I 40 x 3 mm size 60 mm long complete all as per specified.
31M&L for Exposed metal frame ceiling with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid (Frame work form ceiling shall be measured and paid separately) complete all as specified and directed.
32S&F CPVC pipes 16mm dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified including taking down old unserviceable pipes complete all as specified and directed.
33S&F CPVC pipes 20mm dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified including taking down old unserviceable pipes complete all as specified and directed.
34S&F CPVC pipes 25mm dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified including taking down old unserviceable pipes complete all as specified and directed.
35S&F in repair of stainless steel sink with one side draining board made out of 1.00mm thick sheet for kitchen with plug washers, waste pipe, CI cantilever brackets, connection union overall size 1040mmx510mmx203 with bowl i.e. 510x405x203mm incl making good damaged surfaces with cement morter (1:3) to match with the existing and complete all as directed by Engineer-in-Charge.(Make: Prayag, Cat No 1244DM or Equivalent)
36S&F in repair 1mm thick stainless steel kitchen plate rack of size 786x760x254mm and fixing in position as directed by Engineer-in-Charge.(Make: Prayag, Cat No P346 or Equivalent)
37S&F in repairs vitreous china (white) wash down water closet pan (pedestal pattern) with 'P' or 'S' trap front or back inlet, fixing bolts(except flushing cistern and flush pipe) incl seat cover and mild steel chromium plated or aluminium hinging device complete all as specified and directed.
38S&F in repair vitreous china (white) wash hand basin of size 550mm x 400mm incl providing 32mm dia CP wasted coupling, CP bottle trap bracket and making all necessary connections, fixed complete all as specified and directed.
39S&F in repair fancy type chromium plated bib cock long body 15mm size with wall flange, as directed by the Engr-in-Charge.(Make: Prayag, Cat No 9206 or Equivalent)
40S&F in repair 15mm bore Stop valves fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
41S&F in repair fancy type chromium plated pillar cock 15mm size without wall flange, as directed by the Engr-in-Charge. (Make: Prayag, Cat No 9204 or Equivalent)
42S&F in repair for Tubular towel rail, Brass chromium plated, 20mm dia, D type, 60cm long between flanges complete all as specified and directed. Make: Prayag or Equivalent
43S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. (Make: Prayag, Cat No BEA-40S or Equivalent)
44S&F in repair of Liquid soap container of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 105gms) complete all as specified and directed.
45S&F in repair of Grating doom 125 mm dia with waste hole of PTMT. (Minimum weight 40gms) complete all as specified and directed.
46S&F in repair 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed..
47M&L in repair PVC (Plastic polymer Cistern) valve less, Syphonic action type, flushing cistern of capacity 10 litres, low level, white with inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32mm PVC flush pipe of required length including PVC Connection pipe of 450mm length and making connections complete all as specified and directed.
48S&F in repair PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints fixed to walls/ floor complete including clamps for securing pipe complete all as specified and directed.
49S&F in repairs PVC (SWR) bend with access door of any radius 110mm bore complete all as specified and directed..
50S&F in repair PVC (SWR) pipes 75 mm dia single socketed in any length with rubber ring joints fixed to walls/ floor complete including clamps for securing pipe complete all as specified and directed.
51S&F in repair PVC (SWR) vent cowl 75mm dia complete all as specified and directed.
52S&F in repair PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
53M&L for Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing of CP Push cock, flush pipe and Union for discharge pipe including waste pipie and connection pipe as in repairs.
54Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings removing serviceable sheet to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
55M&L for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick, any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall etc fixed with self tapping screws complete all as specified and as directed by Engineer-in-Charge.
56Dismantling wrought iron or mild steel work of any description not otherwise provided for removing serviceable items to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
57M&L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161- 1979 grade St.-240 complete all as specified and as directed by engineer-In- Charge
58M&L for Cement concrete 1:2:4 (Type B1) using 20mm aggregate in surface channels and drains complete all as specified and directed.
59M&L for Precast cement concrete in Cover slab type B1 1:2:4 using 20mm graded aggregate n.exc 150mm thick) for man holes, chullah hoods,chajjas,water troughs, mangers, shelves and similar articles with Plain Faces complete all as specified and as directed by engineer-In- Charge
60M&L for RCC types A1 1:1.5:3 (20mm graded aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like including demolition complete all as specified and directed.
61All as per Item No. 60 above but in chajjas
62M&L for Formwork to soffits of suspended slabs rough finished concrete flat surface such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick
63M&L for TMT bars 10mm dia cut to length bent to shape etc as required and binding with and including MS wire (annealed) not les than 0.9mm dia as in reinforcement complete all as specified and as directed.
64Demolition of cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
65M&L for 75mm thick cement concrete 1:3:6 type C2, using 40 mm graded aggregate as in plinth protection and finishing surface even and fair without using extra cement complete all as specified and directed.
66M&L for Cement concrete type B-1, 1:2:4 (20mm graded aggregate) 40mm thick as in base of flooring complete all as specified and as directed.
67M&L PCC 1:3:6 type C-2 using 40mm graded stone aggregate 100mm thick as in base of footpath/hardstanding complete all as specified and directed.
68M&L PCC 1:2:4 type B-1 using 20mm graded stone aggregate 75mm thick as in footpath/hardstanding complete all as specified and directed.
69M&L for Spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green complete all as specified and directed.
70Dismantling of PVC water tanks of capacity of exc 500 ltrs and n exc 1000 ltrs and removing serviceable water tank to store complete all as specified and directed by Engineer-in-Charge.
71S&F for 1000 capacity in litres Rotational moulded polyethylene water storage tanks made of 3 layer virgin plastic (cylindrical vertical with closed top) white in colour ISI marked hoisted and fixed in position. (Make: Sintex-CCTS-0200-01 or Equivalent.)
72Taking down cement plaster including racking out joints, hacking for key scrubbing down with water etc including removal of rubbish material from site complete all as specified and directed by Engineer-in-Charge.
73M&L for rendering 15mm thick plaster in CM 1:4 in two layers (10mm and 5mm thick) mixed with water proofing compound with 5mm thick layer on fair faces of brick work or concrete surfaces including finishing the surface even and smooth without using extra cement, complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately.
74M&L for 10mm thick plaster in cm (1:6) on fair faces of brick or concrete surfaces including finishing even & smooth without using extra cement complete all as specified and directed.
75M&L for 5mm thick plaster in cm (1:3) on fair faces of concrete surfaces of ceiling including finishing even & smooth without using extra cement complete all as specified and directed.
76M&L for preparation of new wall surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm with a finsih of plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete
77M&L for preparation of new wall surfaces and applying 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work over a coat of primer including plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed.
78M&L for preparation of new plastered ceiling surfaces and applying 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work over a coat of primer complete all as specified and directed..
79M&L for complete removal of existing treatment from external wall surface and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm with a finsih of plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed.
80M&L for complete removal of existing treatment from wall surface and applying 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work over a coat of primer including plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smoothcomplete all as specified and directed.
81M&L for preparation of old painted wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
82M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
83M&L for complete removal of existing treatment from old ceiling surfaces and applying 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work over a coat of primer complete all as per specified and directed.
84SCHEDULE 'A PART-I E/M WORKS)Taking down carefully copper /aluminiium point wiring ( light,fan,socket or power ) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets ,light fitting etc . Removing materials matrials to stores for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately ) and making good disturbed surfaces of walls, floors complete all as per specified and directed.
85M&L for point wiring with PVC insulated, PVC unsheathed FRLS cable, single core, stranded, copper conductor cable 1.5 sqmm size, drawn in and including Non metallic rigid PVC conduit 20mm dia with all accessories and including PVC unsheathed FRLS cable , 1.5 sqmm stranded copper cable (green insulation) for continuous earth wire for the following :-
86One light point or fan/Exhaust Fan point controlled by one switch
87One point for socket outlet 5 amp same board
88One 3 pin socket outlet, 5 amps, independent
89One 3 pin socket outlet, 15 amps. Independent , with cables 2.5 Sqmm size copper conductor cable with continuous earth wire of 1.5 sqmm copper conductor on independent board.
90Supply and fixing metal flush box 6 module complete as directed
91Supply and fixing metal flush box 4 module complete as directed .
92Supply and fixing metal flush box 3 module complete as directed.
93Supply and fixing metal flush box 2 module complete as directed.
94Supply and fixing modular cover plate with frame 6 Module complete as directed .
95Supply and fixing modular cover plate with frame 4 Module complete as directed.
96Supply and fixing modular cover plate with frame 3 Module complete as directed .
97Supply and fixing modular cover plate with frame 2 Module complete as directed.
98Supply and fixing modular switch 6 amps Single module complete as directed .
99Supply and fixing modular switch 16 amps Single module complete as directed .
100Supply and fixing modular socket 6 amps 5 pin socket Single Module complete as directed .
101Supply and fixing modular socket 6/16 amp 3 pin combined Single Module complete as directed.
102Supply and fixing modular fan regulator 2 Module complete as directed .
103S&F ceiling rose, 3 phase/PVC/polycarbonate, isolated body for surface type, bakelite 65x50mm three terminal
104S&F lamp holder (angular) insulated body with back plate suitable for batten fittings complete all as specified & directed
105S&F energy efficient light emmitting fluorescent light fitting 1x20 watt, four feet , white fittings with LED rod complete with all accessories & Provn of three core cable of copper conductor of size 0.75 sqmm, making necessary electric connetion from ceiling rose to fitting terminal , fixing the fitting on wall complete all as specified & directed.
106S&F for energy efficient light emmitting fluorescent light fitting 1x10 watt Two feet LED tube light with LED rod complete with all accessories & Provn of three core cable of copper conductor of size 0.75 sqmm, making necessary electric connetion from ceiling rose to fitting terminal , fixing the fitting on wall including all necessary fixing accessories complete all as directed.
107S & F LED bulb 9W, B22 holder based Cool Daylight lamp with polycarbonate body and aluminium heat sink with warm white all as specified and as directed.
108Taking down Existing Ceiling Fans/exhaust fan any make and size/any condition, keeping at site for reuse, cleaning, painting, refixing the same in serviceable condition after completion of repair works in old or new location complete all as directed.
109S&F Building security light LED street light fitting 35watt, made up of pressure die cast aluminum housing with high power LEDs with secondary optics, IP66 protection, Orion Neo LED street light with poly carbonate cover including GI Bracket made out of 40 mm dia medium grade GI tube up to 1.5 m long bend to shape 115 degree off set shape, fixed with 2 nos of suitable MS Flat clame of size 40x6 mm with necessary nut bolts & washers and applying two coats of aluminum enameled paint over one coat of zinc oxide primer for clamp complete all as specified.
110M&L in repair for two single core (submain) PVC insulated FR cable with 6 sqmm nominal cross sectional area stranded copper conductor and one single core green PVC insulated FR cable 6 sqmm stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit including all conduit and fixing accessories, concealed in wall including cutting chases and making good disturbed surface to match complete all as specified.
111Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 4 mm GI Wire [Earth Lead] and GI pipe 15 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 5 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified.
112S&F in repair MCB DB, TPN, 4 Way, 415 Volts, sheet steel phospetised powder coated, Vertical, with DIN Channel, Double Door with 200 Amps rated bus bar 415V nautral link suitable for mounting MCBs, IP:43 protection complete all as specified and as directed
113S&F in repair MCB DB double door ,IP 43 protection single pole and neutral 8 way sheet steel phospetised powder painted with 200 amps rated bus bar 240V natural link complete all as specified
114S&F MCB SPN 32 Amps, 10 KA rating, complete all as specified and directed
115S&F MCB TPN 63 Amps, 10 KA rating complete all as specified and directed
116S&F MCB SP 6 to 32 Amps, 10 KA rating complete all as specified and directed Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56652402
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 36 Lakhs
LAST DATE 13-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repairs To Fire Station Bldg No. P-17 At Nad Sunabeda, Odisha Under Ge (P) (Navy) Visakhapatnam
Basic Detail
Tender No 8966/E8
Bidding Type Tender
Location
City Koraput
State Odisha
Key Dates
Publish Date 31 Jul 2026
Submission Date 13 Aug 2026
Open Date 01 Jan 0001
Finance
Tender Value 36 Lakhs
Tender Fee 500
EMD 72000
Exemption Available
Document List
34e7b922-57d6-402c-8a71-60effe8a7f79.html
BOQ_873876.xls
Tender8966.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 31, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Aug 13, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 13 days
Aug 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
html

34e7b922-57d6-402c-8a71-60effe8a7f79.html

xls

BOQ_873876.xls

pdf

Tender8966.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail