Housing Urban and Rular Development Government Departments Closing in 5 days TDR #56651360

Tender For Revenue Tower Ernakulam - Retro Fitting Works

Issued by Government Departments · Ernakulam, Kerala
Tender Value
1.20 Crore
Estimated cost
Bid Submission
31 Jul 2026
5 days left
EMD
50000
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ernakulam → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Revenue Tower Ernakulam - Retro Fitting Works- 1 Compound Wall 2 5.1.2:Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level:1:1:5:3 (1 Cement 1.5 Coarse Sand :3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 3 4.3.1:Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form Work For:Foundations, Footings, Bases For Columns 4 5.22.6:Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or More 5 50.6.2.1:Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 30X20X15 Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Foundation And Plinth With Thickness 15Cm In: Cm 1:6 ( 1 Cement :6 Coarse Sand) Etc Complete 6 13.1.1:12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 7 14.1.1:Repairs To Plaster Of Thickness 12 Mm To 20 Mm In Patches Of Area 2.5 Sq Meters And Under, Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete, Including Disposal Of Rubbish To The Dumping Ground Within 50 Meters Lead:With Cement Mortar 1:4 ( 1 Cement : Fine Sand) 8 10.25.2:Item Shifted To Sub Head 14 As Item 14.73Item Shifted To Head 14 As Item 14.74Steel Work Welded In Built Up Sections/Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works 9 13.88:Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete. 10 13.46.1:Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade:New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/10 Sqm) 11 10.26.3:Providing And Fixing Hand Rail Of Approved Size By Welding Etc. To Steel Ladder Railing, Balcony Railing, Staircase Railing And Similar Works, Including Applying Priming Coat Of Approves Steel Primer.G.I. Pipes 12 13.61.1:Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 13 19.21.1:Making Connection Of Drain Or Sewer Line With Existing Manhole Including Breaking Into And Making Good The Walls, Floors With Cement Concrete 1:2:4 Mix( 1 Cement:2 Coarse Sand: 4 Graded Stone Aggregate 20 Mm Nominal Size) Cement Plastered On Both Sides With Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand) Finished With A Floating Coat Of Neat Cement And Making Necessary Channels For The Drain Etc. Complete.For Pipes 100 To 250 Mm Diameter 14 19.7.2.1:Constructing Brick Masonry Manhole In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand) With R.C.C. Top With 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size), Foundation Concrete 1:4:8 Mix ( 1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size,) Inside Plastering 12 Mm Thick With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand) Finished With Floating Coat Of Neat Cement And Making Channels In Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design:Inside Size 120X90 Cm And 90 Cm Deep Including C.I. Cover With Frame ( Medium Duty ) 500 Mm Internal Diameter, Total Weight Of Cover And Frame To Be Not Less Than 116 Kg ( Weight Of Cover 58 Kg And Weight Of Frame 58 Kg):With Common Burnt Clay F.P.S ( Non Modular) Bricks Of Class Designation 7.5 15 19.8.2.1:Extra For Depth For Manholessize 120X90 Cmwith Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 16 Interlock 17 15.2.1:Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In-Charge.Nominal Concrete 1:3:6 Or Richer Mix (I/C Equivalent Design Mix) 18 15.28.1:Dismantling Roofing Including Ridges, Hips, Velleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of :G.S. Sheet 19 15.7.4:Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar 20 16.83:Taking Out Existing Cc Interlocking Paver Blocks From Footpath/ Central Verge, Including Removal Of Rubbish Etc., Disposal Of Unserviceable Material To The Dumping Ground, For Which Payment Shall Be Made Separately And Stacking Of Serviceable Material Within 50 Metre Lead As Per Direction Of Engineer-In-Charge. 21 15.60:Disposal Of Building Rubbish/ Malba/ Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved 22 50.2.25.1:Filling With ContractorS Own Earth ( Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M As Per Direction Of Site Engineer-In-Charge 23 16.91.2:Providing And Laying Factory Made Chamfered Edge Cement Concrete Paver Blocksin Footpath, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc, Of Required Strength,Thickness & Size/ Shape, Made By Table Vibratory Method Using Pu Mould, Laid Inrequired Colour & Pattern Over 50Mm Thick Compacted Bed Of Sand, Compacting Andproper Embedding/Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layerthrough Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand Andcutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweepingextra Sand. Complete All As Per Direction Of Engineer-In-Charge.80 Mm Thick C.C. Paver Block Of M-30 Grade With Approved Color Design And Pattern. 24 Od40981/2026-2027:Providing And Laying Factory Made Chamfered Edge Cement Concrete Paver Blocksin Footpath, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc, Of Required Strength,Thickness & Size/ Shape, Made By Table Vibratory Method Using Pu Mould, Laid Inrequired Colour & Pattern Over 50Mm Thick Compacted Bed Of Sand, Compacting Andproper Embedding/Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layerthrough Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand Andcutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweepingextra Sand. Complete All As Per Direction Of Engineer-In-Charge.80 Mm Thick Departmental C.C. Paver Block . 25 4.1.3:Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:2:4 (Cement : 2 Coarse Sand (Zone-Iii)Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 26 16.47.2:Painting Runway/ Taxi Track /Apron Making With Adequate Nos Of Coats To Give Uniform Finish With Road Marking Paint Of Superior Make As Approved By The Engineer-In-Charge, I/C Cleaning The Surface Of All Dirt, Scales, Oil Grease And Other Foreign Material Etc. And Lining Out Complete.Old Work (One Or More Coats) 27 G/L Parking Maintenance 28 4.1.3:Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:2:4 (Cement : 2 Coarse Sand (Zone-Iii)Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 29 11.8:Extra For Making Chequers Of Approved Pattern On Cement Concrete Floors, Steps, Landing, Pavements Etc. 30 21.1.1.1:Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing /Paneling, C.P. Brass/ Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge.(Glazing, Paneling And Dash Fasteners To Be Paid For Separately):For Fixed Portionanodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is : 1868, Minimum Anodic Coating Of Grade Ac 15) 31 21.1.2.1:For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/ Neoprene Gasket Required (Fittings Shall Be Paid For Separately)Anodised Aluminium ( Anodised Transparent Or Dyed To Required Shade According To Is : 1868, Minimum Anodic Coating Of Grade Ac 15) 32 21.3.1:Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item):With Float Glass Panes Of 4.0 Mm Thickness (Weight Not Less Than 10Kg/Sqm) 33 14.1.1:Repairs To Plaster Of Thickness 12 Mm To 20 Mm In Patches Of Area 2.5 Sq Meters And Under, Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete, Including Disposal Of Rubbish To The Dumping Ground Within 50 Meters Lead:With Cement Mortar 1:4 ( 1 Cement : Fine Sand) 34 10.25.2:Item Shifted To Sub Head 14 As Item 14.73Item Shifted To Head 14 As Item 14.74Steel Work Welded In Built Up Sections/Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works 35 13.111.1:Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade :Old Work (Two Or More Coat Applied @ 1.67 Ltr/ 10 Sqm) On Existing Cement Paint Surface 36 Toilet 37 14.82:Dismantling W.C. Pan Of All Sizes Including Disposal Of Dismantled Materials I/C Malba All Complete As Per Directions Of Engineer-In-Charge 38 15.52:Dismantling Of Flushing Cistern Of All Types (C.I. / Pvc/ Vitrious China) Including Stacking Of Useful Materials Near The Site And Disposal Of Unserviceable Materials Within 50 Metres Lead 39 15.12.1:Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead:Of Area 3 Sq. Metres And Below 40 15.60:Disposal Of Building Rubbish/ Malba/ Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved 41 17.18.1:Providing And Fixing P.V.C. Low Level Flushing Cistern With Manually Controlled Device (Handle Lever) Conforming To Is: 7231, With All Fittings And Fixtures Complete.10 Litre Capacity - White 42 17.2.1:Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required:W.C. Pan With Isi Marked White Solid Plastic Seat And Lid 43 17.28.1.2:Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including Pvc.Waste Fittings Complete.Semi Rigid Pipe40 Mm Dia 44 Od41368/2026-2027:Providing And Fixing White Vitreous China Flat Back Or Wall Corner Type Lipped Front Urinal Basin Of 430X260X350 Mm And 340X410X265 Mm Sizes Respectively G.I. Clamps Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required: 45 9.119:Providing And Fixing Factory Made P.V.C. Door Frame Of Size 50X47 Mm With A Wall Thickness Of 5 Mm, Made Out Of Extruded 5 Mm Rigid Pvc Foam Sheet, Mitred At Corners And Joined With 2 Nos. Of 150 Mm Long Brackets Of 15X15 Mm M.S. Square Tube, The Vertical Door Frame Profiles To Be Reinforced With 19X19 Mm M.S. Square Tube Of 19 Gauge, Epdm Rubber Gasket Weather Seal To Be Provided Through Out The Frame. The Door Fame To Be Fixed To The Wall Using M.S. Screws Of 65/100 Mm Size, Complete As Per ManufacturerS Specification And Direction Of Engineer-In Charge. 46 9.120.1:Providing And Fixing Factory Made Panel Pvc Door Shutter Consisting Of Frame Made Out Of M.S. Tubes Of 19 Gauge Thickness And Sized Of 19 Mm X 19 Mm For Styles And 15X15 Mm For Top & Bottom Rails. M.S. Frame Shall Have A Coat Of Steel Primers Of Approved Make And Manufacture. M.S. Frame Covered With 5 Mm Thick Heat Moulded Pvc C Channel Of Size 30 Mm Thickness, 70 Mm Width Out Of Whicj 50 Mm Shall Be Flat And 20 Mm Shall Be Tapered In 45 Degree Angle On Both Side Forming Styles And 5Mm Thick, 95 Mm Wide Pvc Sheet Out Of Which75 Mm Shall Be Tapered In 45 Degree On Th Inner Side To Form Top And Bottom Rail And 115 Mm Wide Pvc Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered On Both Sides To Form Lock Rail. Top, Bottom And Lock Rails Shall Be Provided Both Side Of The Panel. 10 Mm (5 Mmx2) Thick, 20 Mm Wide Cross Pvc Sheet Be Provided As Gap Insert For Top Rail & Bottom Rail. Paneling Of 5 Mm Thick Both Side Pvc Sheet To Be Fitted In The M.S. Frame Welded /Sealed To The Styles & Rails With 7 Mm (5 Mm + 2 Mm ) Thick X 15 Mm Wide Pvc Sheet Beading On Inner Side, And Joined Together With Solvent Cement Adhesive. An Additional 5 Mm Thick Pvc Strip Of 20 Mm Width Is To Be Stuck On The Interior Side Of The C Channel Using Pvc Solvent Adhesive Etc. Complete As Per Direction Of Engineer -In-Charge, ManufactureS Specification & Drawing.30 Mm Thick Plain Pvc Door Shutters 47 50.9.15.1:Supplying And Fixing 200 Mm Aluminium Aldrop 48 9.108.2:Providing And Fixing Ptmt Tower Bolts With 12 Mm One Piece Rod Inside And Necessary Screws Etc., Complete.202X42X18 Mm Weighing Not Less Than 78 Gms 49 8.10.2:Providing And Fixing Stone Slab With Table Rubbed, Edges Rounded And Polished, Of Size 75X50 Cm Deep And 1.8 Cm Thick, Fixed In Urinal Partitions By Cutting A Chase Of Appropriate Width With Chase Cutter And Embedding The Stone In The Chase With Epoxy Grout Or With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 6 Mm Nominal Size) As Per Direction Of Engineer-In Charge And Finished Smooth.Granite Stone Of Approved Shade 50 15.23.1:Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead.For Thickness Of Tiles 10 Mm To 25 Mm 51 50.18.8.6.2:Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 50 Mm Pipe 6 Kgf/Cm2 52 50.18.8.7.1:Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work Including Cutting Chases And Making Good The Wall Etc. 63 Mm Pipe 6 Kgf/Cm2 53 50.18.8.8.1:Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 75 Mm Pipe 6 Kgf/Cm2 54 Od99160/2026-2027:Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints Of 3 3Mm Width Using Epoxy Grout Mix 0.7Kg Of Organic Coated Filler Of Desired Shade Etc., Complete.Size Of Tile 600 Mm Width Tiles 55 Od99161/2026-2027:Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer), With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Brand & Manufacturer,In All Colours And Shade, In Walls With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, In Average 6 Mm Thickness, Including Grouting Of Joints Of 3 Mm Width Using Epoxy Grout Mix .7 Kg Of Organic Coated Filler Of Desired Shade.Size Of Tile 600 Mm Width Tiles 56 21.1.1.2:Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing /Paneling, C.P. Brass/ Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge.(Glazing, Paneling And Dash Fasteners To Be Paid For Separately):For Fixed Portionpowder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) 57 21.1.2.1:For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/ Neoprene Gasket Required (Fittings Shall Be Paid For Separately)Anodised Aluminium ( Anodised Transparent Or Dyed To Required Shade According To Is : 1868, Minimum Anodic Coating Of Grade Ac 15) 58 21.3.1:Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item):With Float Glass Panes Of 4.0 Mm Thickness (Weight Not Less Than 10Kg/Sqm) 59 21.12.3:Providing And Fixing Aluminium Tubular Handle Bar 32 Mm Outer Dia, 3.0Mm Thick & 2100 Mm Long With S.S. Screws Etc. Complete As Per Direction Of Engineer -In-Charge.Polyester Powder Coated Minimum Thickness 50 Micron Aluminium Tubular Handle Bar 60 9.7.5.3:Providing And Fixing Panelling Or Panelling And Glazing In Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows (Area Of Opening For Panel Inserts Excluding Portion Inside Grooves Or Rebates To Be Measured), Panelling For Panelled Or Panelled And Glazed Shutters 25 Mm To 40 Mm Thick:Particle Board 12 Mm Thickpre-Laminated Particle Board With Decorative Lamination On One Side And Balancing Lamination On Other Side, Grade I, Type Ii, Is : 12823 Marked 61 17.7.1:Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps 62 17.28.2.1:Flexible Pipe32 Mm Dia 63 18.56.2:Providing And Fixing Ptmt Pillar Cock Of Approved Quality And Colour.15 Mm Nominal Bore, 125 Mm Long Foam Flow, Weighing Not Less Than 120 Gms 64 Od99582/2026-2027:Providing And Fixing Cp Brass Pillar Taps Approved Quality .15 Mm Nominal Bore As Per The Direction Of Enginner In Charge 65 18.21.1.1:Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions:30 Cm Length15 Mm Nominal Bore 66 18.15.1:Providing And Fixing Brass Bib Cock Of Approved Quality :15 Mm Nominal Bore 67 50.17.1.4:Supplying And Fixing Cp Health Faucet Good Quality Including Cost Of Materials And Labour Charges Etc. Complete As Per The Direction Of Site Engineer-In-Charge. 68 Od100681/2026-2027:Providing And Fixing C.P. Brass Two Way Angle Cock For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is: 893115 Mm Nominal Bore 69 9.100.1:Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete:125 Mm 70 14.31.1:Providing And Fixing Bright Finished Brass Single Acting Spring Hinges With Necessary Brass Screws Etc. Complete:150 Mm 71 14.33.1:Providing And Fixing Bright Finished Brass Flush Bolts With Necessary Brass Screws Etc. Complete250 Mm 72 9.83:Providing And Fixing Aluminium Die Cast Body Tubular Type Universal Hydraulic Door Closer (Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 35 Kg And Door Width Upto 700 Mm), With Necessary Accessories And Screws Etc. Complete. 73 9.103:Providing And Fixing Bright Finished Brass 100 Mm Mortice Latch And Lock, Isi Marked, With Six Levers And A Pair Of Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is: 1868) Aluminium Lever Handles Of Approved Quality With Necessary Screws Etc . Complete. 74 13.99.1:Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade :One Or More Coats On Old Work 75 14.34:Providing And Fixing 150 Mm Bright Finished Floor Brass Door Stopper With Rubber Cushion, Necessary Brass Screws Etc. To Suit Shutter Thickness Complete 76 14.77:Cleaning Of Chocked Sewer Line By Diesel Running Vehicle Mounting Hydraulic Operated High Pressure Suction Cum Jetting Sewer Cleaning Machine Fitted With Pump Having 4000 Litres Suction Capacity And 6000 Litres Water Jetting Tank Capacity Including Skilled Operator, Supervising Engineer Etc. For Cleaning And Partial Desilting Of Manholes And Dechocking Of Sewer Lines. Dechocking And Flushing Of Sewer Line From One Manhole To Another By High Pressure Jetting System Of 2200 Psi For Sewer Line From 150Mm Dia Upto 300Mm Dia For All Depth. 77 14.78:Cleaning Of Under Ground Sump, Over Head R.C.C. Tank ( Independent Staging) Including Disposal Of Slit And Rubbish, All As Per Direction Of Engineer-In-Charge. The Cleaning Shall Consist Following Operations:- (I)Tank Shall Be Emptied Of Water By Pumping & Bottom Shall Be Cleaned Of Slit And Other Deposits. (Ii) Entire Surface Area Of The Sump Shall Then Scrubbed Thoroughly With Wire Brush Etc. And Pressure Washed With Water. (Iii) Chlorination Of Rcc Internal Surface By Liquid Chlorine. <Br> (Iv) The Treated Surface Shall Be Dried Using Air Jetting And All Loose Particles Shall Be Removal From The Surface. (V) Finally The Surface Shall Be Treated With Ultraviolet Radiation Etc. As Per Direction Of Engineer-In-Charge. 78 Fire Stair 79 14.1.1:Repairs To Plaster Of Thickness 12 Mm To 20 Mm In Patches Of Area 2.5 Sq Meters And Under, Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete, Including Disposal Of Rubbish To The Dumping Ground Within 50 Meters Lead:With Cement Mortar 1:4 ( 1 Cement : Fine Sand) 80 13.99.1:Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade :One Or More Coats On Old Work 81 False Ceiling 82 15.57:Dismantling Aluminium / Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Material And Stacking Of Serviceable Material With In 50 Metres Lead As Directed By Engineer - In-Charge 83 12.59.1:Providing And Fixing False Ceiling At All Height Including Providing & Fixing Of Framework Made Of Special Section, Power Pressed From M.S. Sheets And Galvanised With Zinc Coating Of 120 Gms/ Sqm (Both Side Inclusive) As Per Is : 277 And Consisting Of Angle Cleat Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37 Mm, At 1200Mm C/C, One Flange Fixed To The Ceiling With Dash Fastener 12.5Mm Dia X 50Mm Long With 6Mm Dia Bolts, Other Flanged Of Cleat Fixed To The Angle Hangers Of 25X10X0.50Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I Chanels 45X15X0.90Mm Running At The Spacing Of 1200 Mm C/C, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80Mm With Tapered Flanges Of 26Mm Each Having Lips Of 10.5Mm, At 450Mm C/C, Shall Be Fixed In A Direction Perpendicular To G.I Intermediate Channel With Connecting Clip Made Out Of 2.64Mm Dia X 230Mm Long G.I Wire At Every Junction, Including Fixing Perimeter Channels 0.50Mm Thick 27 Mm High Having Flages Of 20Mm And 30Mm Long, The Perimeter Of Ceiling Fixed To Wall/ Partitions With The Help Of Rawl Plugs At 450Mm Centre, With 25Mm Long Dry Wall Screws @ 230Mm Interval, Including Fixing Of Calcium Silicate Board To Ceiling Section And Perimeter Channels With The Help Of Day Wall Screws Of Size 3.5X25Mm At 230Mm C/C, Including Jointing & Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compounds, Jointing Tapes, Finishing With Jointing Compounds In Three Layers Covering Up To 150Mm On Both Sides Of Joints And Two Coats Of Primer Suitable For Boards, All As Per ManufactureS Specification And Also Including The Cost Of Making Opening For Light Fittings, Grills, Diffusers, Cut Outs Made With Frame Of Perimeter Channels Suitable Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With.A.8 Mm Thick Calcium Silicate Board Made With Calcareous & Siliceous Materials Reinforced With Cellulose Fiber Manufactured Through Acutoclaving Process. 84 21.5:Providing And Fixing Powder Coated Aluminium Work ( Minimum Thickness Of Powder Coating 50 Micron) Consisting Of Tee /Angle Sections, Of Approved Make Conforming To Is : 733 In Frames Of False Ceiling Including Aluminium Angle Cleats With Necessary C.P Brass/ Stainless Steel Sunk Screws, Aluminium Perimeter Angles Fixed To Wall With Stainless Steel Rawl Plugs @ 450 Mm Centre To Centre And Fixing The Frame Work To G.I Level Adjusting Hangers 6 Mm Dia. With Necessary Cadmium Plated Machine Screws All Complete As Per Approved Architectural Drawings And Direction Of The Engineer-In-Charge ( Level Adjusting Hangers, Ceiling Cleats And Expansion Hold Fasteners To Be Paid For Separately ). 85 Od90058/2026-2027:Providing And Fixing False Ceiling At All Heightinto The Exissting Aluminium Frame Work As Per The Direction Of Engineer In Charge. But Excluding The Cost Of Painting With.A.8 Mm Thick Calcium Silicate Board Made With Calcareous & Siliceous Materials Reinforced With Cellulose Fiber Manufactured Through Acutoclaving Process. 86 Glazing Works 87 15.57:Dismantling Aluminium / Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Material And Stacking Of Serviceable Material With In 50 Metres Lead As Directed By Engineer - In-Charge 88 15.18:Dismantling Steel Work In Built Up Sections In Angles, Tees, Flats And Channels Including All Gusset Plates,Bolts, Nuts, Cutting Rivets, Welding Etc. Including Dismembering And Stacking Within 50 Metres Lead. 89 14.72:Providing And Fixing Double Scaffolding System (Cup Lock Type) On The Exterior Side, Upto Seven Story Hight Made With 40 Mm Dia. M.S. Tube 1.5 M Centre To Centre, Horizontal & Vertical Tubes Joining With Cup & Lock System With M.S. Tubes, M.S. Tube Challies, M.S. Clamps And M.S. Staricase System In The Scaffolding For Working Platform Etc. And Maintaining It In A Serviceable Condition For The Required Duration As Approved And Removing It There After. The Scaffolding System Shall Be Stiffened With Bracings, Runners, Connection With The Building Etc Wherever Required For Inspection Of Work At Required Location With Essential Safety Features For The Workmen Etc. Complete As Per Directions And Approval Of Engineer- In Charge. The Elevational Area Of The Scaffolding Shall Be Measured For Payment Purpose. The Payment Will Be Made Once Irrespective Of Duration Of Scaffolding. Note:- This Item To Be Used For Maintenance Work Judicially, Necessary Deduction For Scaffolding In The Existing Item To Be Done . 90 5.2.2:Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 91 5.22.6:Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or More 92 10.25.2:Item Shifted To Sub Head 14 As Item 14.73Item Shifted To Head 14 As Item 14.74Steel Work Welded In Built Up Sections/Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works 93 50.6.3.2:Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X10 Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level For 10 Cm Thick Wall In : Cm 1:6 ( 1 Cement : 6 Coarse Sand) Including Cost Of Scaffolding Complete 94 13.1.1:12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 95 14.1.2:Repairs To Plaster Of Thickness 12 Mm To 20 Mm In Patches Of Area 2.5 Sq Meters And Under, Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete, Including Disposal Of Rubbish To The Dumping Ground Within 50 Meters Lead:Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand) 96 13.60.1:Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 97 21.1.1.2:Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing /Paneling, C.P. Brass/ Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge.(Glazing, Paneling And Dash Fasteners To Be Paid For Separately):For Fixed Portionpowder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) 98 21.1.2.2:For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/ Neoprene Gasket Required (Fittings Shall Be Paid For Separately)Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) 99 Od40282/2026-2027:Providing And Fixing Acp Sheet In Structural Glazing Work With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item):With Acp Sheet Of 3 Mm Thickness (Weight Not Less Than 5.25 Kg/Sqm) 100 Od90572/2026-2027:Providing And Fixing Acp In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item):With Acp Panels Of Of 3.0 Mm Thickness. 101 25.6: Providing And Supplying Spandrel Glass Panels Comprising Of 6 Mm Thick Heat Strengthened Monolithic Float Glass Of Approved Colour And Shade With Reflective Soft Coating On Surface # 2 Of Approved Colour And Shade So As To Match The Colour And Shade Of The Igus In The Vision Panels Etc., All Complete For The Required Performance As Specified, As Per The Architectural Drawings, As Per The Approved Shop Drawings, As Specified, And As Directed By The Engineer- In - Charge. For Payment, Only The Actual Area Of Glass On Face # 1 Of The Glass Panels (But Excluding The Area Of Grooves And Weather Silicone Sealant) Provided And Fixed In Position, Shall Be Measured In Sqm. (Payment For Fixing Of Spandrel Glass Panels In The Curtain Glazing Is Included In Cost Of Relevent Item*). ?(I) Coloured Tinted Float Glass 6Mm Thicksubstrate With Reflective Soft Coating On Face # 2, Having Properties As Visible Light Transmittance (Vlt) Of 25 To 35 %, Light Reflection Internal 10 To 15%, Light Reflection External 10 To 20 %, Shading Coefficient (0.25- 0.28) And U Value Of 3.0 To 3.3 W/M2 K Etc. .The Properties Of Performance Glass Shall Be Decided By Technical Sanctioning Authority As Per The Site Requirement. 102 Od90439/2026-2027:Removing Glazing From The Existing Portion And Re Fix It With Same Glass With Silicon Sealant, Baker Rod ,Desecant Etc As Per The Direction Of Engineer In Charge. 103 21.11.1:Providing And Fixing Stainless Steel (Ss 304 Grade) Adjustable Friction Window Stays Of Approved Quality With Necessary Stainless Steel Screws Etc. To The Side Hung Windows As Per Direction Of Engineer - In-Charge Complete.205 X 19 Mm 104 9.100.1:Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete:125 Mm 105 13.99.1:Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade :One Or More Coats On Old Work 106 15.60:Disposal Of Building Rubbish/ Malba/ Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved 107 Terrace Floor 108 14.1.1:Repairs To Plaster Of Thickness 12 Mm To 20 Mm In Patches Of Area 2.5 Sq Meters And Under, Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete, Including Disposal Of Rubbish To The Dumping Ground Within 50 Meters Lead:With Cement Mortar 1:4 ( 1 Cement : Fine Sand) 109 13.88:Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete. 110 13.46.1:Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade:New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/10 Sqm) 111 Wiring And Accessories 112 1.10.2:Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvcinsulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit,With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frlspvc Insulated Copper Conductor Single Core Cable Etc As Required.Group B 113 1.17.3:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.3 X 1.5 Sq.Mm 114 1.17.12:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.3 X 2.5 Sq. Mm 115 1.21.1:Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.20 Mm 116 1.31:Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5/6 Amps Modular Socket Outlet And 5/6 Amps Modular Switch, Connection Etc. As Required. (For Light Plugs To Be Used In Non Residential Buildings). 117 1.32:Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5/6 & 15/16 Amps Modular Socket Outlet And 15/16 Amps Modular Switch, Connection Etc. As Required. 118 1.58:Supplying And Fixing Pvc Batten/ Angle Holder Including Connection Etc. As Required. 119 Od68483/2026-2027:Supply And Providing The Following Types And Power Rated Lamps In The Existing Angle Holder/Fittings As Required 9 W Led Bulb 120 Od64394/2026-2027:Supply Conveyance, Installation, Testing And Commissioning The Following Types Of Strip Type /Slim Type Led Light Fittings Made From Crca Sheet With All Accessories And Lamps Directly On Wall/Rcc Ceiling And Giving Connections With 16/0.20 Mm 3 Core Pvc Insulated And Sheathed Round Copper Conductor Flex Wire Or Extending The Original Wiring And Giving Connections As Required Like Philips/ Bajaj/ Wipro/ Dewton. 16W To 20W Led Light Fittings(Including Inbuilt Led Tube Fittings ) 121 19.1:Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep Bee-5 Star Rated Ceiling Fan With Brushless Direct Current Motor (Bldc) , Class Of Insulation B , 3 No:S Blades , 30 Cm Long Down Rod , 2No:S Canopies, Shackle Kit, Safety Rope , Copper Winding, Power Factor Not Less Than .9, Service Value (Cm/M/W) Minimum 6.00, Air Delivery Minimum 210 Cum/Min,350 Rpm (Tolerance As Per Is :374-2019, Thd Less Than 10% Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accesories Including Safety Pin, Nut And Bolts , Washers, Temperature Rise Equal To 75 Deg Celsius ( Maximum) , Insulation Resistance More Than 2 Megaohm , Suitable For 230V,50 Hz, Single Phase Ac Supply , Earthing Etc., Complete As Required: 122 90.15.4.7:Supply Conveyance, Installation, Testing And Commissioning Of 100W Led Flood Light Output Greater Than 105Lumen/W 4000-6000 K With Ip 66 Protection Led Chip Make Cree/Lumilled/Nichea With Power Factor Greater Than 0.95 At Full Load, Internal Surge Protection Up To 8 Kv,And Aluminium Pressure Die-Cast Powder Coated Housing, Acrylic Cover Complete With Thd Less Than 10%, Power Factor Greater Than 0.98, Rohs Compliant, Duly Wired Up For Use On 230 V Ac Supply. Driver Compartment Should Be Seperatly Accessible For Maintenance (Lm 79&80 Certificates From Nabl Accredited Third Party Lab To Be Produced Mentioning Chip Manufacturer) 123 Od64395/2026-2027:Supply Of The Following Sizes Of Exhaust Fans In The Existing Opening, Fixing Necessary Bolt And Nuts, Making Good The Damages Etc. As Required Including Giving Connections With Required Length Of 24/0.20Mm Pvc Insulated And Pvc Sheathed 3 Core Round Copper Conductor Flex Wire Conforming To Relevant Is Upto 250 To 300 Mm, Single Phase, Light Duty Exhaust Fan In Plastic Body With Self Opening Louvers 124 1.51:Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required 125 2.10.1:Supplying And Fixing 5A To 32 A Rating, 240/415 Volts, 10 Ka, \\C\\ Curve, Miniaturecircuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcbdb Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole 126 90.12.7.1:Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required.2 Core 4 Sq Mm With Factory Made Clamp 127 2.13.1:Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 128 2.14.2:Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral),240 Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Milli Amperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 129 Panel Boards 130 Od64400/2026-2027:The Maintenance Of The Electrical Panel Boards Includes Thorough Cleaning, Tightening Of All Electrical Connections, Inspection And Testing Of Mcbs, Mccbs, Bus Bars, Cable Terminations, Indicator Lamps, Meters, And Internal Wiring. The Work Also Includes Identification And Rectification Of Loose Connections, Overheating, Dust Accumulation, Moisture Ingress, And Replacement Of Damaged Breaker,Breaker Handles, Fuse Units, Indicator Lamps, And Other Defective Components To Prevent Electrical Faults, Power Interruptions, And Fire Hazards. In Addition, Insulation Resistance Testing, Functional Testing Of Protective Devices, And Verification Of The Overall Condition Of The Electrical Distribution System Will Be Carried Out To Ensure Safe And Reliable Operation. 131 Diesel Generator Overhauling

BOQ

Name of Work:- REVENUE TOWER ERNAKULAM - RETRO FITTING WORKS
Sl. No. Item Description
1Compound wall
25.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources)
34.3.1:Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns
45.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
550.6.2.1:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete
613.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
714.1.1:Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand)
810.25.2:Item Shifted to Sub head 14 as item 14.73Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
913.88:Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
1013.46.1:Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
1110.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
1213.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
1319.21.1:Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix( 1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 ( 1 cement: 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete.For pipes 100 to 250 mm diameter
1419.7.2.1:Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 120x90 cm and 90 cm deep including C.I. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg):With common burnt clay F.P.S ( non modular) bricks of class designation 7.5
1519.8.2.1:Extra for depth for manholesSize 120x90 cmWith common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5
16Interlock
1715.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
1815.28.1:Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :G.S. Sheet
1915.7.4:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
2016.83:Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
2115.60:Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved
2250.2.25.1:Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
2316.91.2:Providing and laying factory made chamfered edge Cement Concrete paver blocksin footpath, parks, lawns, drive ways or light traffic parking etc, of required strength,thickness & size/ shape, made by table vibratory method using PU mould, laid inrequired colour & pattern over 50mm thick compacted bed of sand, compacting andproper embedding/laying of inter locking paver blocks into the sand bedding layerthrough vibratory compaction by using plate vibrator, filling the joints with sand andcutting of paver blocks as per required size and pattern, finishing and sweepingextra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.
24OD40981/2026-2027:Providing and laying factory made chamfered edge Cement Concrete paver blocksin footpath, parks, lawns, drive ways or light traffic parking etc, of required strength,thickness & size/ shape, made by table vibratory method using PU mould, laid inrequired colour & pattern over 50mm thick compacted bed of sand, compacting andproper embedding/laying of inter locking paver blocks into the sand bedding layerthrough vibratory compaction by using plate vibrator, filling the joints with sand andcutting of paver blocks as per required size and pattern, finishing and sweepingextra sand. complete all as per direction of Engineer-in-Charge.80 mm thick departmental C.C. paver block .
254.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
2616.47.2:Painting runway/ taxi track /apron making with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-Charge, i/c cleaning the surface of all dirt, scales, oil grease and other foreign material etc. and lining out complete.Old work (One or more coats)
27G/L Parking Maintenance
284.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
2911.8:Extra for making chequers of approved pattern on cement concrete floors, steps, landing, pavements etc.
3021.1.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionAnodised aluminium (anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15)
3121.1.2.1:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Anodised aluminium ( anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15)
3221.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
3314.1.1:Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand)
3410.25.2:Item Shifted to Sub head 14 as item 14.73Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
3513.111.1:Finishing walls with Acrylic Smooth exterior paint of required shade :Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface
36Toilet
3714.82:Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge
3815.52:Dismantling of flushing cistern of all types (C.I. / PVC/ Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead
3915.12.1:Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below
4015.60:Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved
4117.18.1:Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete.10 litre capacity - White
4217.2.1:Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid
4317.28.1.2:Providing and fixing P.V.C. waste pipe for sink or wash basin including PVC.waste fittings complete.Semi rigid pipe40 mm dia
44OD41368/2026-2027:Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:
459.119:Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos. of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door fame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer's specification and direction of Engineer-in Charge.
469.120.1:Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and sized of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of whicj 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5mm thick, 95 mm wide PVC sheet out of which75 mm shall be tapered in 45 degree on th inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mmx2) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded /sealed to the styles & rails with 7 mm (5 mm + 2 mm ) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer -in-charge, manufacture's specification & drawing.30 mm thick plain PVC door shutters
4750.9.15.1:Supplying and fixing 200 mm Aluminium aldrop
489.108.2:Providing and fixing PTMT Tower Bolts with 12 mm one piece rod inside and necessary screws etc., complete.202x42x18 mm weighing not less than 78 gms
498.10.2:Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in Charge and finished smooth.Granite Stone of approved shade
5015.23.1:Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm
5150.18.8.6.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2
5250.18.8.7.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work including cutting chases and making good the wall etc. 63 mm pipe 6 Kgf/cm2
5350.18.8.8.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2
54OD99160/2026-2027:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints of 3 3mm width using epoxy grout mix 0.7kg of organic coated filler of desired shade etc., complete.Size of Tile 600 mm width tiles
55OD99161/2026-2027:Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer,in all colours and shade, in walls with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints of 3 mm width using epoxy grout mix .7 kg of organic coated filler of desired shade.Size of Tile 600 mm width tiles
5621.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
5721.1.2.1:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Anodised aluminium ( anodised transparent or dyed to required shade according to IS : 1868, Minimum anodic coating of grade AC 15)
5821.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
5921.12.3:Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0mm thick & 2100 mm long with S.S. screws etc. complete as per direction of Engineer -in-Charge.Polyester powder coated minimum thickness 50 micron aluminium tubular handle bar
609.7.5.3:Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:Particle Board 12 mm thickPre-laminated particle board with decorative lamination on one side and balancing lamination on other side, Grade I, Type II, IS : 12823 marked
6117.7.1:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
6217.28.2.1:Flexible pipe32 mm dia
6318.56.2:Providing and fixing PTMT pillar cock of approved quality and colour.15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gms
64OD99582/2026-2027:Providing and fixing CP brass pillar taps approved quality .15 mm nominal bore as per the direction of enginner in charge
6518.21.1.1:Providing and fixing uplasticised PVC connection pipe with brass unions:30 cm length15 mm nominal bore
6618.15.1:Providing and fixing brass bib cock of approved quality :15 mm nominal bore
6750.17.1.4:Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge.
68OD100681/2026-2027:Providing and fixing C.P. brass two way angle cock for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore
699.100.1:Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm
7014.31.1:Providing and fixing bright finished brass single acting spring hinges with necessary brass screws etc. complete:150 mm
7114.33.1:Providing and fixing bright finished brass flush bolts with necessary brass screws etc. complete250 mm
729.83:Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
739.103:Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS: 1868) aluminium lever handles of approved quality with necessary screws etc . complete.
7413.99.1:Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work
7514.34:Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete
7614.77:Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150mm dia upto 300mm dia for all depth.
7714.78:Cleaning of under ground sump, Over Head R.C.C. Tank ( independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:- (i)Tank shall be emptied of water by pumping & bottom shall be cleaned of slit and other deposits. (ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water. (iii) Chlorination of RCC internal surface by liquid chlorine. <br> (iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface. (v) Finally the surface shall be treated with ultraviolet radiation etc. as per direction of Engineer-in-Charge.
78Fire stair
7914.1.1:Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand)
8013.99.1:Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work
81False Ceiling
8215.57:Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge
8312.59.1:Providing and fixing false ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flanged of cleat fixed to the angle hangers of 25x10x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45x15x0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5 mm thick bottom wedge of 80mm with tapered flanges of 26mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27 mm high having flages of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of day wall screws of size 3.5x25mm at 230mm c/c, including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes, finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufacture's specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitable fixed, all complete as per drawings, specification and direction of the Engineer in charge but excluding the cost of painting with.a.8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through acutoclaving process.
8421.5:Providing and fixing powder coated aluminium work ( minimum thickness of powder coating 50 micron) consisting of tee /angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-Charge ( level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately ).
85OD90058/2026-2027:Providing and fixing false ceiling at all heightinto the exissting aluminium frame work as per the direction of engineer in charge. but excluding the cost of painting with.a.8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through acutoclaving process.
86Glazing works
8715.57:Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge
8815.18:Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates,bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.
8914.72:Providing and fixing double scaffolding system (cup lock type) on the exterior side, upto seven story hight made with 40 mm dia. M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staricase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required location with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in Charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. Note:- This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done .
905.2.2:Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
915.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
9210.25.2:Item Shifted to Sub head 14 as item 14.73Item Shifted to head 14 as item 14.74Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
9350.6.3.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete
9413.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
9514.1.2:Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:Cement mortar 1:4 ( 1 cement: 4 coarse sand)
9613.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
9721.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
9821.1.2.2:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
99OD40282/2026-2027:Providing and fixing ACP Sheet in Structural Glazing work with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With ACP Sheet of 3 mm thickness (weight not less than 5.25 kg/sqm)
100OD90572/2026-2027:Providing and fixing ACP in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With ACP panels of of 3.0 mm thickness.
10125.6: Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc., all complete for the required performance as specified, as per the architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in - Charge. For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (Payment for fixing of Spandrel Glass panels in the curtain glazing is included in cost of relevent item*). ?(i) Coloured tinted float glass 6mm thicksubstrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. .The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
102OD90439/2026-2027:Removing Glazing from the Existing portion and re fix it with same glass with silicon sealant, baker rod ,desecant etc as per the direction of engineer in charge.
10321.11.1:Providing and fixing stainless steel (SS 304 grade) adjustable friction window stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer - in-Charge complete.205 x 19 mm
1049.100.1:Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm
10513.99.1:Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work
10615.60:Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved
107Terrace Floor
10814.1.1:Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand)
10913.88:Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
11013.46.1:Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
111Wiring and accessories
1121.10.2:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group B
1131.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1141.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1151.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1161.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1171.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1181.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
119OD68483/2026-2027:Supply and providing the following types and power rated lamps in the existing Angle holder/fittings as required 9 W LED BULB
120OD64394/2026-2027:Supply conveyance, installation, testing and commissioning the following types of strip type /Slim Type LED light fittings made from CRCA sheet with all accessories and lamps directly on wall/RCC Ceiling and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required like Philips/ Bajaj/ Wipro/ DEWTON. 16W to 20W LED light fittings(including inbuilt LED tube fittings )
12119.1:Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star rated ceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no:s blades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copper winding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Air delivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD less than 10% remote or electronic regulator unit for speed control and all remaining accesories including safety pin, nut and bolts , washers, temperature rise equal to 75 deg celsius ( maximum) , insulation resistance more than 2 Megaohm , suitable for 230V,50 Hz, single phase AC supply , earthing etc., complete as required:
12290.15.4.7:Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
123OD64395/2026-2027:Supply of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant IS upto 250 to 300 mm, single phase, light duty exhaust fan in plastic body with self opening louvers
1241.51:Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required
1252.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole
12690.12.7.1:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 4 sq mm with factory made clamp
1272.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1282.14.2:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
129Panel Boards
130OD64400/2026-2027:The maintenance of the electrical panel boards includes thorough cleaning, tightening of all electrical connections, inspection and testing of MCBs, MCCBs, bus bars, cable terminations, indicator lamps, meters, and internal wiring. The work also includes identification and rectification of loose connections, overheating, dust accumulation, moisture ingress, and replacement of damaged breaker,breaker handles, fuse units, indicator lamps, and other defective components to prevent electrical faults, power interruptions, and fire hazards. In addition, insulation resistance testing, functional testing of protective devices, and verification of the overall condition of the electrical distribution system will be carried out to ensure safe and reliable operation.
131Diesel generator Overhauling
132OD64490/2026-2027:The scope of DG overhauling shall include complete inspection, dismantling, cleaning, repair, reconditioning, replacement of worn-out or defective parts with new genuine or Engineer-approved equivalent parts, reassembly, testing, trial run, and commissioning of the DG set to restore it to satisfactory operating condition. The work shall include all labour, tools, tackles, lifting equipment, dismantling and handling, loading and unloading, transportation (where required), industrial machinery, consumables, lubricants, replacement parts, calibration, performance testing, and all incidental works necessary to complete the overhaul in accordance with the manufacturer's recommendations and the instructions of the Engineer-in-Charge, complete in all respects. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56651360
AUTHORITY Government Departments
TENDER VALUE 1.20 Crore
LAST DATE 31-07-2026
Authority
Authority Name kerala state housing board
Work Description Tender For Revenue Tower Ernakulam - Retro Fitting Works- 1 Compound Wall 2 5.1.2:Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level:1:1:5:3 (1 Cement 1.5 Coarse Sand :3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 3 4.3.1:Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form Work For:Foundations, Footings, Bases For Columns 4 5.22.6:Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or More 5 50.6.2.1:Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 30X20X15 Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Foundation And Plinth With Thickness 15Cm In: Cm 1:6 ( 1 Cement :6 Coarse Sand) Etc Complete 6 13.1.1:12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 7 14.1.1:Repairs To Plaster Of Thickness 12 Mm To 20 Mm In Patches Of Area 2.5 Sq Meters And Under, Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete, Including Disposal Of Rubbish To The Dumping Ground Within 50 Meters Lead:With Cement Mortar 1:4 ( 1 Cement : Fine Sand) 8 10.25.2:Item Shifted To Sub Head 14 As Item 14.73Item Shifted To Head 14 As Item 14.74Steel Work Welded In Built Up Sections/Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works 9 13.88:Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete. 10 13.46.1:Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade:New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/10 Sqm) 11 10.26.3:Providing And Fixing Hand Rail Of Approved Size By Welding Etc. To Steel Ladder Railing, Balcony Railing, Staircase Railing And Similar Works, Including Applying Priming Coat Of Approves Steel Primer.G.I. Pipes 12 13.61.1:Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 13 19.21.1:Making Connection Of Drain Or Sewer Line With Existing Manhole Including Breaking Into And Making Good The Walls, Floors With Cement Concrete 1:2:4 Mix( 1 Cement:2 Coarse Sand: 4 Graded Stone Aggregate 20 Mm Nominal Size) Cement Plastered On Both Sides With Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand) Finished With A Floating Coat Of Neat Cement And Making Necessary Channels For The Drain Etc. Complete.For Pipes 100 To 250 Mm Diameter 14 19.7.2.1:Constructing Brick Masonry Manhole In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand) With R.C.C. Top With 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size), Foundation Concrete 1:4:8 Mix ( 1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size,) Inside Plastering 12 Mm Thick With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand) Finished With Floating Coat Of Neat Cement And Making Channels In Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design:Inside Size 120X90 Cm And 90 Cm Deep Including C.I. Cover With Frame ( Medium Duty ) 500 Mm Internal Diameter, Total Weight Of Cover And Frame To Be Not Less Than 116 Kg ( Weight Of Cover 58 Kg And Weight Of Frame 58 Kg):With Common Burnt Clay F.P.S ( Non Modular) Bricks Of Class Designation 7.5 15 19.8.2.1:Extra For Depth For Manholessize 120X90 Cmwith Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 16 Interlock 17 15.2.1:Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In-Charge.Nominal Concrete 1:3:6 Or Richer Mix (I/C Equivalent Design Mix) 18 15.28.1:Dismantling Roofing Including Ridges, Hips, Velleys And Gutters Etc., And Stacking The Material Within 50 Metres Lead Of :G.S. Sheet 19 15.7.4:Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar 20 16.83:Taking Out Existing Cc Interlocking Paver Blocks From Footpath/ Central Verge, Including Removal Of Rubbish Etc., Disposal Of Unserviceable Material To The Dumping Ground, For Which Payment Shall Be Made Separately And Stacking Of Serviceable Material Within 50 Metre Lead As Per Direction Of Engineer-In-Charge. 21 15.60:Disposal Of Building Rubbish/ Malba/ Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved 22 50.2.25.1:Filling With ContractorS Own Earth ( Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M As Per Direction Of Site Engineer-In-Charge 23 16.91.2:Providing And Laying Factory Made Chamfered Edge Cement Concrete Paver Blocksin Footpath, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc, Of Required Strength,Thickness & Size/ Shape, Made By Table Vibratory Method Using Pu Mould, Laid Inrequired Colour & Pattern Over 50Mm Thick Compacted Bed Of Sand, Compacting Andproper Embedding/Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layerthrough Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand Andcutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweepingextra Sand. Complete All As Per Direction Of Engineer-In-Charge.80 Mm Thick C.C. Paver Block Of M-30 Grade With Approved Color Design And Pattern. 24 Od40981/2026-2027:Providing And Laying Factory Made Chamfered Edge Cement Concrete Paver Blocksin Footpath, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc, Of Required Strength,Thickness & Size/ Shape, Made By Table Vibratory Method Using Pu Mould, Laid Inrequired Colour & Pattern Over 50Mm Thick Compacted Bed Of Sand, Compacting Andproper Embedding/Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layerthrough Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand Andcutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweepingextra Sand. Complete All As Per Direction Of Engineer-In-Charge.80 Mm Thick Departmental C.C. Paver Block . 25 4.1.3:Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:2:4 (Cement : 2 Coarse Sand (Zone-Iii)Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 26 16.47.2:Painting Runway/ Taxi Track /Apron Making With Adequate Nos Of Coats To Give Uniform Finish With Road Marking Paint Of Superior Make As Approved By The Engineer-In-Charge, I/C Cleaning The Surface Of All Dirt, Scales, Oil Grease And Other Foreign Material Etc. And Lining Out Complete.Old Work (One Or More Coats) 27 G/L Parking Maintenance 28 4.1.3:Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:2:4 (Cement : 2 Coarse Sand (Zone-Iii)Derived From Natural Sources : 4 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 29 11.8:Extra For Making Chequers Of Approved Pattern On Cement Concrete Floors, Steps, Landing, Pavements Etc. 30 21.1.1.1:Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing /Paneling, C.P. Brass/ Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge.(Glazing, Paneling And Dash Fasteners To Be Paid For Separately):For Fixed Portionanodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is : 1868, Minimum Anodic Coating Of Grade Ac 15) 31 21.1.2.1:For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/ Neoprene Gasket Required (Fittings Shall Be Paid For Separately)Anodised Aluminium ( Anodised Transparent Or Dyed To Required Shade According To Is : 1868, Minimum Anodic Coating Of Grade Ac 15) 32 21.3.1:Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item):With Float Glass Panes Of 4.0 Mm Thickness (Weight Not Less Than 10Kg/Sqm) 33 14.1.1:Repairs To Plaster Of Thickness 12 Mm To 20 Mm In Patches Of Area 2.5 Sq Meters And Under, Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete, Including Disposal Of Rubbish To The Dumping Ground Within 50 Meters Lead:With Cement Mortar 1:4 ( 1 Cement : Fine Sand) 34 10.25.2:Item Shifted To Sub Head 14 As Item 14.73Item Shifted To Head 14 As Item 14.74Steel Work Welded In Built Up Sections/Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works 35 13.111.1:Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade :Old Work (Two Or More Coat Applied @ 1.67 Ltr/ 10 Sqm) On Existing Cement Paint Surface 36 Toilet 37 14.82:Dismantling W.C. Pan Of All Sizes Including Disposal Of Dismantled Materials I/C Malba All Complete As Per Directions Of Engineer-In-Charge 38 15.52:Dismantling Of Flushing Cistern Of All Types (C.I. / Pvc/ Vitrious China) Including Stacking Of Useful Materials Near The Site And Disposal Of Unserviceable Materials Within 50 Metres Lead 39 15.12.1:Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead:Of Area 3 Sq. Metres And Below 40 15.60:Disposal Of Building Rubbish/ Malba/ Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved 41 17.18.1:Providing And Fixing P.V.C. Low Level Flushing Cistern With Manually Controlled Device (Handle Lever) Conforming To Is: 7231, With All Fittings And Fixtures Complete.10 Litre Capacity - White 42 17.2.1:Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required:W.C. Pan With Isi Marked White Solid Plastic Seat And Lid 43 17.28.1.2:Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including Pvc.Waste Fittings Complete.Semi Rigid Pipe40 Mm Dia 44 Od41368/2026-2027:Providing And Fixing White Vitreous China Flat Back Or Wall Corner Type Lipped Front Urinal Basin Of 430X260X350 Mm And 340X410X265 Mm Sizes Respectively G.I. Clamps Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required: 45 9.119:Providing And Fixing Factory Made P.V.C. Door Frame Of Size 50X47 Mm With A Wall Thickness Of 5 Mm, Made Out Of Extruded 5 Mm Rigid Pvc Foam Sheet, Mitred At Corners And Joined With 2 Nos. Of 150 Mm Long Brackets Of 15X15 Mm M.S. Square Tube, The Vertical Door Frame Profiles To Be Reinforced With 19X19 Mm M.S. Square Tube Of 19 Gauge, Epdm Rubber Gasket Weather Seal To Be Provided Through Out The Frame. The Door Fame To Be Fixed To The Wall Using M.S. Screws Of 65/100 Mm Size, Complete As Per ManufacturerS Specification And Direction Of Engineer-In Charge. 46 9.120.1:Providing And Fixing Factory Made Panel Pvc Door Shutter Consisting Of Frame Made Out Of M.S. Tubes Of 19 Gauge Thickness And Sized Of 19 Mm X 19 Mm For Styles And 15X15 Mm For Top & Bottom Rails. M.S. Frame Shall Have A Coat Of Steel Primers Of Approved Make And Manufacture. M.S. Frame Covered With 5 Mm Thick Heat Moulded Pvc C Channel Of Size 30 Mm Thickness, 70 Mm Width Out Of Whicj 50 Mm Shall Be Flat And 20 Mm Shall Be Tapered In 45 Degree Angle On Both Side Forming Styles And 5Mm Thick, 95 Mm Wide Pvc Sheet Out Of Which75 Mm Shall Be Tapered In 45 Degree On Th Inner Side To Form Top And Bottom Rail And 115 Mm Wide Pvc Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered On Both Sides To Form Lock Rail. Top, Bottom And Lock Rails Shall Be Provided Both Side Of The Panel. 10 Mm (5 Mmx2) Thick, 20 Mm Wide Cross Pvc Sheet Be Provided As Gap Insert For Top Rail & Bottom Rail. Paneling Of 5 Mm Thick Both Side Pvc Sheet To Be Fitted In The M.S. Frame Welded /Sealed To The Styles & Rails With 7 Mm (5 Mm + 2 Mm ) Thick X 15 Mm Wide Pvc Sheet Beading On Inner Side, And Joined Together With Solvent Cement Adhesive. An Additional 5 Mm Thick Pvc Strip Of 20 Mm Width Is To Be Stuck On The Interior Side Of The C Channel Using Pvc Solvent Adhesive Etc. Complete As Per Direction Of Engineer -In-Charge, ManufactureS Specification & Drawing.30 Mm Thick Plain Pvc Door Shutters 47 50.9.15.1:Supplying And Fixing 200 Mm Aluminium Aldrop 48 9.108.2:Providing And Fixing Ptmt Tower Bolts With 12 Mm One Piece Rod Inside And Necessary Screws Etc., Complete.202X42X18 Mm Weighing Not Less Than 78 Gms 49 8.10.2:Providing And Fixing Stone Slab With Table Rubbed, Edges Rounded And Polished, Of Size 75X50 Cm Deep And 1.8 Cm Thick, Fixed In Urinal Partitions By Cutting A Chase Of Appropriate Width With Chase Cutter And Embedding The Stone In The Chase With Epoxy Grout Or With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 6 Mm Nominal Size) As Per Direction Of Engineer-In Charge And Finished Smooth.Granite Stone Of Approved Shade 50 15.23.1:Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead.For Thickness Of Tiles 10 Mm To 25 Mm 51 50.18.8.6.2:Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 50 Mm Pipe 6 Kgf/Cm2 52 50.18.8.7.1:Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work Including Cutting Chases And Making Good The Wall Etc. 63 Mm Pipe 6 Kgf/Cm2 53 50.18.8.8.1:Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 75 Mm Pipe 6 Kgf/Cm2 54 Od99160/2026-2027:Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints Of 3 3Mm Width Using Epoxy Grout Mix 0.7Kg Of Organic Coated Filler Of Desired Shade Etc., Complete.Size Of Tile 600 Mm Width Tiles 55 Od99161/2026-2027:Providing And Laying Vitrified Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer), With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Brand & Manufacturer,In All Colours And Shade, In Walls With Cement Based High Polymer Modified Quick Set Tile Adhesive (Water Based) Conforming To Is : 15477, In Average 6 Mm Thickness, Including Grouting Of Joints Of 3 Mm Width Using Epoxy Grout Mix .7 Kg Of Organic Coated Filler Of Desired Shade.Size Of Tile 600 Mm Width Tiles 56 21.1.1.2:Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing /Paneling, C.P. Brass/ Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge.(Glazing, Paneling And Dash Fasteners To Be Paid For Separately):For Fixed Portionpowder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) 57 21.1.2.1:For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/ Neoprene Gasket Required (Fittings Shall Be Paid For Separately)Anodised Aluminium ( Anodised Transparent Or Dyed To Required Shade According To Is : 1868, Minimum Anodic Coating Of Grade Ac 15) 58 21.3.1:Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item):With Float Glass Panes Of 4.0 Mm Thickness (Weight Not Less Than 10Kg/Sqm) 59 21.12.3:Providing And Fixing Aluminium Tubular Handle Bar 32 Mm Outer Dia, 3.0Mm Thick & 2100 Mm Long With S.S. Screws Etc. Complete As Per Direction Of Engineer -In-Charge.Polyester Powder Coated Minimum Thickness 50 Micron Aluminium Tubular Handle Bar 60 9.7.5.3:Providing And Fixing Panelling Or Panelling And Glazing In Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows (Area Of Opening For Panel Inserts Excluding Portion Inside Grooves Or Rebates To Be Measured), Panelling For Panelled Or Panelled And Glazed Shutters 25 Mm To 40 Mm Thick:Particle Board 12 Mm Thickpre-Laminated Particle Board With Decorative Lamination On One Side And Balancing Lamination On Other Side, Grade I, Type Ii, Is : 12823 Marked 61 17.7.1:Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps 62 17.28.2.1:Flexible Pipe32 Mm Dia 63 18.56.2:Providing And Fixing Ptmt Pillar Cock Of Approved Quality And Colour.15 Mm Nominal Bore, 125 Mm Long Foam Flow, Weighing Not Less Than 120 Gms 64 Od99582/2026-2027:Providing And Fixing Cp Brass Pillar Taps Approved Quality .15 Mm Nominal Bore As Per The Direction Of Enginner In Charge 65 18.21.1.1:Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions:30 Cm Length15 Mm Nominal Bore 66 18.15.1:Providing And Fixing Brass Bib Cock Of Approved Quality :15 Mm Nominal Bore 67 50.17.1.4:Supplying And Fixing Cp Health Faucet Good Quality Including Cost Of Materials And Labour Charges Etc. Complete As Per The Direction Of Site Engineer-In-Charge. 68 Od100681/2026-2027:Providing And Fixing C.P. Brass Two Way Angle Cock For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is: 893115 Mm Nominal Bore 69 9.100.1:Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete:125 Mm 70 14.31.1:Providing And Fixing Bright Finished Brass Single Acting Spring Hinges With Necessary Brass Screws Etc. Complete:150 Mm 71 14.33.1:Providing And Fixing Bright Finished Brass Flush Bolts With Necessary Brass Screws Etc. Complete250 Mm 72 9.83:Providing And Fixing Aluminium Die Cast Body Tubular Type Universal Hydraulic Door Closer (Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 35 Kg And Door Width Upto 700 Mm), With Necessary Accessories And Screws Etc. Complete. 73 9.103:Providing And Fixing Bright Finished Brass 100 Mm Mortice Latch And Lock, Isi Marked, With Six Levers And A Pair Of Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is: 1868) Aluminium Lever Handles Of Approved Quality With Necessary Screws Etc . Complete. 74 13.99.1:Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade :One Or More Coats On Old Work 75 14.34:Providing And Fixing 150 Mm Bright Finished Floor Brass Door Stopper With Rubber Cushion, Necessary Brass Screws Etc. To Suit Shutter Thickness Complete 76 14.77:Cleaning Of Chocked Sewer Line By Diesel Running Vehicle Mounting Hydraulic Operated High Pressure Suction Cum Jetting Sewer Cleaning Machine Fitted With Pump Having 4000 Litres Suction Capacity And 6000 Litres Water Jetting Tank Capacity Including Skilled Operator, Supervising Engineer Etc. For Cleaning And Partial Desilting Of Manholes And Dechocking Of Sewer Lines. Dechocking And Flushing Of Sewer Line From One Manhole To Another By High Pressure Jetting System Of 2200 Psi For Sewer Line From 150Mm Dia Upto 300Mm Dia For All Depth. 77 14.78:Cleaning Of Under Ground Sump, Over Head R.C.C. Tank ( Independent Staging) Including Disposal Of Slit And Rubbish, All As Per Direction Of Engineer-In-Charge. The Cleaning Shall Consist Following Operations:- (I)Tank Shall Be Emptied Of Water By Pumping & Bottom Shall Be Cleaned Of Slit And Other Deposits. (Ii) Entire Surface Area Of The Sump Shall Then Scrubbed Thoroughly With Wire Brush Etc. And Pressure Washed With Water. (Iii) Chlorination Of Rcc Internal Surface By Liquid Chlorine. <Br> (Iv) The Treated Surface Shall Be Dried Using Air Jetting And All Loose Particles Shall Be Removal From The Surface. (V) Finally The Surface Shall Be Treated With Ultraviolet Radiation Etc. As Per Direction Of Engineer-In-Charge. 78 Fire Stair 79 14.1.1:Repairs To Plaster Of Thickness 12 Mm To 20 Mm In Patches Of Area 2.5 Sq Meters And Under, Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete, Including Disposal Of Rubbish To The Dumping Ground Within 50 Meters Lead:With Cement Mortar 1:4 ( 1 Cement : Fine Sand) 80 13.99.1:Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade :One Or More Coats On Old Work 81 False Ceiling 82 15.57:Dismantling Aluminium / Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Material And Stacking Of Serviceable Material With In 50 Metres Lead As Directed By Engineer - In-Charge 83 12.59.1:Providing And Fixing False Ceiling At All Height Including Providing & Fixing Of Framework Made Of Special Section, Power Pressed From M.S. Sheets And Galvanised With Zinc Coating Of 120 Gms/ Sqm (Both Side Inclusive) As Per Is : 277 And Consisting Of Angle Cleat Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37 Mm, At 1200Mm C/C, One Flange Fixed To The Ceiling With Dash Fastener 12.5Mm Dia X 50Mm Long With 6Mm Dia Bolts, Other Flanged Of Cleat Fixed To The Angle Hangers Of 25X10X0.50Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I Chanels 45X15X0.90Mm Running At The Spacing Of 1200 Mm C/C, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80Mm With Tapered Flanges Of 26Mm Each Having Lips Of 10.5Mm, At 450Mm C/C, Shall Be Fixed In A Direction Perpendicular To G.I Intermediate Channel With Connecting Clip Made Out Of 2.64Mm Dia X 230Mm Long G.I Wire At Every Junction, Including Fixing Perimeter Channels 0.50Mm Thick 27 Mm High Having Flages Of 20Mm And 30Mm Long, The Perimeter Of Ceiling Fixed To Wall/ Partitions With The Help Of Rawl Plugs At 450Mm Centre, With 25Mm Long Dry Wall Screws @ 230Mm Interval, Including Fixing Of Calcium Silicate Board To Ceiling Section And Perimeter Channels With The Help Of Day Wall Screws Of Size 3.5X25Mm At 230Mm C/C, Including Jointing & Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compounds, Jointing Tapes, Finishing With Jointing Compounds In Three Layers Covering Up To 150Mm On Both Sides Of Joints And Two Coats Of Primer Suitable For Boards, All As Per ManufactureS Specification And Also Including The Cost Of Making Opening For Light Fittings, Grills, Diffusers, Cut Outs Made With Frame Of Perimeter Channels Suitable Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With.A.8 Mm Thick Calcium Silicate Board Made With Calcareous & Siliceous Materials Reinforced With Cellulose Fiber Manufactured Through Acutoclaving Process. 84 21.5:Providing And Fixing Powder Coated Aluminium Work ( Minimum Thickness Of Powder Coating 50 Micron) Consisting Of Tee /Angle Sections, Of Approved Make Conforming To Is : 733 In Frames Of False Ceiling Including Aluminium Angle Cleats With Necessary C.P Brass/ Stainless Steel Sunk Screws, Aluminium Perimeter Angles Fixed To Wall With Stainless Steel Rawl Plugs @ 450 Mm Centre To Centre And Fixing The Frame Work To G.I Level Adjusting Hangers 6 Mm Dia. With Necessary Cadmium Plated Machine Screws All Complete As Per Approved Architectural Drawings And Direction Of The Engineer-In-Charge ( Level Adjusting Hangers, Ceiling Cleats And Expansion Hold Fasteners To Be Paid For Separately ). 85 Od90058/2026-2027:Providing And Fixing False Ceiling At All Heightinto The Exissting Aluminium Frame Work As Per The Direction Of Engineer In Charge. But Excluding The Cost Of Painting With.A.8 Mm Thick Calcium Silicate Board Made With Calcareous & Siliceous Materials Reinforced With Cellulose Fiber Manufactured Through Acutoclaving Process. 86 Glazing Works 87 15.57:Dismantling Aluminium / Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Material And Stacking Of Serviceable Material With In 50 Metres Lead As Directed By Engineer - In-Charge 88 15.18:Dismantling Steel Work In Built Up Sections In Angles, Tees, Flats And Channels Including All Gusset Plates,Bolts, Nuts, Cutting Rivets, Welding Etc. Including Dismembering And Stacking Within 50 Metres Lead. 89 14.72:Providing And Fixing Double Scaffolding System (Cup Lock Type) On The Exterior Side, Upto Seven Story Hight Made With 40 Mm Dia. M.S. Tube 1.5 M Centre To Centre, Horizontal & Vertical Tubes Joining With Cup & Lock System With M.S. Tubes, M.S. Tube Challies, M.S. Clamps And M.S. Staricase System In The Scaffolding For Working Platform Etc. And Maintaining It In A Serviceable Condition For The Required Duration As Approved And Removing It There After. The Scaffolding System Shall Be Stiffened With Bracings, Runners, Connection With The Building Etc Wherever Required For Inspection Of Work At Required Location With Essential Safety Features For The Workmen Etc. Complete As Per Directions And Approval Of Engineer- In Charge. The Elevational Area Of The Scaffolding Shall Be Measured For Payment Purpose. The Payment Will Be Made Once Irrespective Of Duration Of Scaffolding. Note:- This Item To Be Used For Maintenance Work Judicially, Necessary Deduction For Scaffolding In The Existing Item To Be Done . 90 5.2.2:Reinforced Cement Concrete Work In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Up Tot Floor Five Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) 91 5.22.6:Steel Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or More 92 10.25.2:Item Shifted To Sub Head 14 As Item 14.73Item Shifted To Head 14 As Item 14.74Steel Work Welded In Built Up Sections/Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works 93 50.6.3.2:Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20X10 Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level For 10 Cm Thick Wall In : Cm 1:6 ( 1 Cement : 6 Coarse Sand) Including Cost Of Scaffolding Complete 94 13.1.1:12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) 95 14.1.2:Repairs To Plaster Of Thickness 12 Mm To 20 Mm In Patches Of Area 2.5 Sq Meters And Under, Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete, Including Disposal Of Rubbish To The Dumping Ground Within 50 Meters Lead:Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand) 96 13.60.1:Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 97 21.1.1.2:Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing /Paneling, C.P. Brass/ Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge.(Glazing, Paneling And Dash Fasteners To Be Paid For Separately):For Fixed Portionpowder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) 98 21.1.2.2:For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/ Neoprene Gasket Required (Fittings Shall Be Paid For Separately)Powder Coated Aluminium (Minimum Thickness Of Powder Coating 50 Micron) 99 Od40282/2026-2027:Providing And Fixing Acp Sheet In Structural Glazing Work With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item):With Acp Sheet Of 3 Mm Thickness (Weight Not Less Than 5.25 Kg/Sqm) 100 Od90572/2026-2027:Providing And Fixing Acp In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item):With Acp Panels Of Of 3.0 Mm Thickness. 101 25.6: Providing And Supplying Spandrel Glass Panels Comprising Of 6 Mm Thick Heat Strengthened Monolithic Float Glass Of Approved Colour And Shade With Reflective Soft Coating On Surface # 2 Of Approved Colour And Shade So As To Match The Colour And Shade Of The Igus In The Vision Panels Etc., All Complete For The Required Performance As Specified, As Per The Architectural Drawings, As Per The Approved Shop Drawings, As Specified, And As Directed By The Engineer- In - Charge. For Payment, Only The Actual Area Of Glass On Face # 1 Of The Glass Panels (But Excluding The Area Of Grooves And Weather Silicone Sealant) Provided And Fixed In Position, Shall Be Measured In Sqm. (Payment For Fixing Of Spandrel Glass Panels In The Curtain Glazing Is Included In Cost Of Relevent Item*). ?(I) Coloured Tinted Float Glass 6Mm Thicksubstrate With Reflective Soft Coating On Face # 2, Having Properties As Visible Light Transmittance (Vlt) Of 25 To 35 %, Light Reflection Internal 10 To 15%, Light Reflection External 10 To 20 %, Shading Coefficient (0.25- 0.28) And U Value Of 3.0 To 3.3 W/M2 K Etc. .The Properties Of Performance Glass Shall Be Decided By Technical Sanctioning Authority As Per The Site Requirement. 102 Od90439/2026-2027:Removing Glazing From The Existing Portion And Re Fix It With Same Glass With Silicon Sealant, Baker Rod ,Desecant Etc As Per The Direction Of Engineer In Charge. 103 21.11.1:Providing And Fixing Stainless Steel (Ss 304 Grade) Adjustable Friction Window Stays Of Approved Quality With Necessary Stainless Steel Screws Etc. To The Side Hung Windows As Per Direction Of Engineer - In-Charge Complete.205 X 19 Mm 104 9.100.1:Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete:125 Mm 105 13.99.1:Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade :One Or More Coats On Old Work 106 15.60:Disposal Of Building Rubbish/ Malba/ Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved 107 Terrace Floor 108 14.1.1:Repairs To Plaster Of Thickness 12 Mm To 20 Mm In Patches Of Area 2.5 Sq Meters And Under, Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete, Including Disposal Of Rubbish To The Dumping Ground Within 50 Meters Lead:With Cement Mortar 1:4 ( 1 Cement : Fine Sand) 109 13.88:Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches Etc. Complete. 110 13.46.1:Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade:New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/10 Sqm) 111 Wiring And Accessories 112 1.10.2:Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvcinsulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit,With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frlspvc Insulated Copper Conductor Single Core Cable Etc As Required.Group B 113 1.17.3:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.3 X 1.5 Sq.Mm 114 1.17.12:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.3 X 2.5 Sq. Mm 115 1.21.1:Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.20 Mm 116 1.31:Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5/6 Amps Modular Socket Outlet And 5/6 Amps Modular Switch, Connection Etc. As Required. (For Light Plugs To Be Used In Non Residential Buildings). 117 1.32:Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5/6 & 15/16 Amps Modular Socket Outlet And 15/16 Amps Modular Switch, Connection Etc. As Required. 118 1.58:Supplying And Fixing Pvc Batten/ Angle Holder Including Connection Etc. As Required. 119 Od68483/2026-2027:Supply And Providing The Following Types And Power Rated Lamps In The Existing Angle Holder/Fittings As Required 9 W Led Bulb 120 Od64394/2026-2027:Supply Conveyance, Installation, Testing And Commissioning The Following Types Of Strip Type /Slim Type Led Light Fittings Made From Crca Sheet With All Accessories And Lamps Directly On Wall/Rcc Ceiling And Giving Connections With 16/0.20 Mm 3 Core Pvc Insulated And Sheathed Round Copper Conductor Flex Wire Or Extending The Original Wiring And Giving Connections As Required Like Philips/ Bajaj/ Wipro/ Dewton. 16W To 20W Led Light Fittings(Including Inbuilt Led Tube Fittings ) 121 19.1:Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep Bee-5 Star Rated Ceiling Fan With Brushless Direct Current Motor (Bldc) , Class Of Insulation B , 3 No:S Blades , 30 Cm Long Down Rod , 2No:S Canopies, Shackle Kit, Safety Rope , Copper Winding, Power Factor Not Less Than .9, Service Value (Cm/M/W) Minimum 6.00, Air Delivery Minimum 210 Cum/Min,350 Rpm (Tolerance As Per Is :374-2019, Thd Less Than 10% Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accesories Including Safety Pin, Nut And Bolts , Washers, Temperature Rise Equal To 75 Deg Celsius ( Maximum) , Insulation Resistance More Than 2 Megaohm , Suitable For 230V,50 Hz, Single Phase Ac Supply , Earthing Etc., Complete As Required: 122 90.15.4.7:Supply Conveyance, Installation, Testing And Commissioning Of 100W Led Flood Light Output Greater Than 105Lumen/W 4000-6000 K With Ip 66 Protection Led Chip Make Cree/Lumilled/Nichea With Power Factor Greater Than 0.95 At Full Load, Internal Surge Protection Up To 8 Kv,And Aluminium Pressure Die-Cast Powder Coated Housing, Acrylic Cover Complete With Thd Less Than 10%, Power Factor Greater Than 0.98, Rohs Compliant, Duly Wired Up For Use On 230 V Ac Supply. Driver Compartment Should Be Seperatly Accessible For Maintenance (Lm 79&80 Certificates From Nabl Accredited Third Party Lab To Be Produced Mentioning Chip Manufacturer) 123 Od64395/2026-2027:Supply Of The Following Sizes Of Exhaust Fans In The Existing Opening, Fixing Necessary Bolt And Nuts, Making Good The Damages Etc. As Required Including Giving Connections With Required Length Of 24/0.20Mm Pvc Insulated And Pvc Sheathed 3 Core Round Copper Conductor Flex Wire Conforming To Relevant Is Upto 250 To 300 Mm, Single Phase, Light Duty Exhaust Fan In Plastic Body With Self Opening Louvers 124 1.51:Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required 125 2.10.1:Supplying And Fixing 5A To 32 A Rating, 240/415 Volts, 10 Ka, \\C\\ Curve, Miniaturecircuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcbdb Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole 126 90.12.7.1:Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required.2 Core 4 Sq Mm With Factory Made Clamp 127 2.13.1:Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 128 2.14.2:Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral),240 Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Milli Amperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 129 Panel Boards 130 Od64400/2026-2027:The Maintenance Of The Electrical Panel Boards Includes Thorough Cleaning, Tightening Of All Electrical Connections, Inspection And Testing Of Mcbs, Mccbs, Bus Bars, Cable Terminations, Indicator Lamps, Meters, And Internal Wiring. The Work Also Includes Identification And Rectification Of Loose Connections, Overheating, Dust Accumulation, Moisture Ingress, And Replacement Of Damaged Breaker,Breaker Handles, Fuse Units, Indicator Lamps, And Other Defective Components To Prevent Electrical Faults, Power Interruptions, And Fire Hazards. In Addition, Insulation Resistance Testing, Functional Testing Of Protective Devices, And Verification Of The Overall Condition Of The Electrical Distribution System Will Be Carried Out To Ensure Safe And Reliable Operation. 131 Diesel Generator Overhauling
Basic Detail
Tender No 01_RE_KSHB_KHU_2026-27
Bidding Type Tender
Location
City Ernakulam
State Kerala
Key Dates
Publish Date 24 Jul 2026
Submission Date 31 Jul 2026
Open Date 03 Aug 2026
Finance
Tender Value 1.20 Crore
Tender Fee 5900
EMD 50000
Exemption Not Available
Document List
BOQ_1458464.xls
c881d0fb-d8a7-4145-bee3-e948101b4c67.html
Tendernotice_1.pdf
Tendernotice_2 (6).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Aug 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1458464.xls

html

c881d0fb-d8a7-4145-bee3-e948101b4c67.html

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2 (6).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders