Tender For Annual Repare & Maintenance Works Of 01(One) No. District Water Testing Laboratory And 15(Fifteen) Nos. Sub District Water Testing Laboratories Under Bankura Division P.H.E. Dte. (Twelve Months)
Tender Value
4.84 Lakhs
Estimated cost
Bid Submission
17 Aug 2026
19 days left
EMD
9700
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bankura → West Bengal
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Annual Repare & Maintenance Works Of 01(One) No. District Water Testing Laboratory And 15(Fifteen) Nos. Sub District Water Testing Laboratories Under Bankura Division P.H.E. Dte. (Twelve Months)
BOQ
| Sl. No. | Item Description |
| 1 | Uprooting and removing plants from the surface of walls parapet etc and making good damages. (Repairing of damages to be paid separately). I-10, P-278 , PWD Building Schedule |
| 2 | (a) Small plant of girth of exposed stem upto 75 mm. lift upto 6 mtr. |
| 3 | Clearing compound premises of shurbs, plants, jungles etc. by cutting and removing as directed (Specific permission of Engineer-in-Charge prior to execution will be necessary).(Payment to be made on area cleared) I-19, P-268 , PWD Building Schedule |
| 4 | Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other incidental charges complete in all respect as per specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of ACP I-27, P-250 , PWD Building Schedule |
| 5 | (a) 3mm thick (0.25mm Al.+2.5mm LDPE +0.25mm Al. PVDF coating) |
| 6 | Supplying bubble free float glass of approved make and brandconforming to IS: 2835-1987. I-09 , P-243 , PWD Building Schedule |
| 7 | iii) 5mm thick clear glass. |
| 8 | Supplying PVC rollers for sliding windows as per direction of Engineer in charge. I-06 , P-242 , PWD Building Schedule |
| 9 | Supplying EPDM gusket of approved make and brand as per direction of Engineer in charge. I-08 , P-242 , PWD Building Schedule |
| 10 | i) For sliding windows |
| 11 | b) U shaped EPDM gasket for frames. |
| 12 | ii) For openable / Casement windows |
| 13 | a) EPDM / weather gasket for outer frame and mullion. |
| 14 | Brick work with 1st class bricks in cement mortar (1:6) (b) In superstructure, ground floor I-8/b , P-15 , PWD Building 3rd Corri Page no-02, Sl. No.02/b PWD Building |
| 15 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor). [Including cost of chipping over concrete surface] 20 mm. Th. Sand cement plaster (4:1) to Inside walls I-01/ii/a , P-189 , PWD Building 3rd Corri Page no-50, Sl. No.01/ii/a PWD Building |
| 16 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes. (d) With local hard blackstone variety chips (crusher broken) I-04/d, P-24 , PWD Building 3rd Corri Page no-10, Sl. No-27/d] PWD Building |
| 17 | Removing old paint from blistered painted surface with application of soda, sajimati or any approved chemical paint remover and exposing the original surface including cleaning and thorough washing to remove all traces of the removing agent including taking out shutters and refixing the same where necessary. I-02 , P-203 , PWD Building Schedule |
| 18 | Removing old paint from blistered painted surface of steel or other metal by chipping including scraping and cleaning and exposing the original surface. I-03 , P-203 , PWD Building Schedule |
| 19 | Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) I-05 , P-198 , PWD Building Schedule |
| 20 | (b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. I-01/b , P-200 , PWD Building Schedule |
| 21 | a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. I-01/a , P-200 , PWD Building Schedule |
| 22 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. I-17 , P-197 , PWD Building Schedule |
| 23 | a) Normal Acrylic Emulsion |
| 24 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : I-02 , P-201 , PWD Building Schedule |
| 25 | b) On steel or other metal surface : |
| 26 | (iv) Two coats (with any shade except white) |
| 27 | (B) Painting with superior quality aluminium paint of approved make and brand including smoothening surface by sand papering etc. on steel surface : I-03 , P-201 , PWD Building Schedule |
| 28 | (b) Two coats (Laboratory Instruments) |
| 29 | Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete. I-28 , P-145 , PWD Building Schedule |
| 30 | (i) 250mm x 16mm dia bolt. |
| 31 | Taking out shutter of door and window, dismantling by parts (for repair or replacement of damaged parts) , reassembling and refitting and rehanging same with old fittings but with new screws as necessary. (Where different parts of same shutter are renewed under different item, payment under item 73 will be made once only). I-31 , P-152 , PWD Building Schedule |
| 32 | Resetting old glazed porcelain tiles in 20 mm thick cement mortar (1:4) including 4 Nos of key stone (10 mm) fixed with adhesive of approved quality & 2 mm thick cement slurry using cement @ 2.91 kg/Sq.m at the back of tiles and finishing joints with white cement & colouring oxide [if required ] to match the colour of tiles over application slurry @1.75 kg/ Sq.m below cement mortar including dismantling the old mortar etc. I-10 , P-77 , PWD Building Schedule |
| 33 | d) Anti-termite treatment to the junction of wood work and masonry walls with chemical emulsion by admixing chloro-pyrofos emulsifiable concentrates (1% concentration) with water by weight including spraying at the points of contact with the adjoining masonry by drilling 6m. dia holes at a down-ward angle of about 45 degree at the junction of wood work and masonry and squirting chemical emulsion into these holes at the rate of half litre per hole. The entire work is to be carried out as per specification of Code I.S.-6313 (Part-III)-1981. The shutters are to be sprayed with emulsion. on both sides. All wooden fixtures like almirahs, racks etc. are also to be throughly sprayed with chemical emulsion. (Payme nt will be made on the basis of outside measurements of doors and windows) I-11/d , P-08 , PWD Building Schedule |
| 34 | Fixing only outdoor / street light type fluorescent light fitting complete with all accessories to be fixed/ projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall and painting. I-19, P-C3 , PWD Electrical Schedule |
| 35 | Fixing only fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports incl. S&F EI conduit, ball socket/socket type ceiling plate and connecting the length of PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm) flexible copper wire of 1.10 mt. length. I-15, P-C2 , PWD Electrical Schedule |
| 36 | Painting of ceiling fan with one coat of primer and two coat of synthetic enamel paint by spray painting after cleaning and removing the old paint. I-25, P-C3 , PWD Electrical |
| 37 | Supplying and fixing Changeover switch with Sheet Steel enclosure on flat iron frame on wall with nuts bolts etc. I-2/a, P-D1 , PWD Electrical Schedule |
| 38 | 32A, 240V DP, Havells |
| 39 | Wiring with 1.1 KV grade single core PVC insulated stranded Copper wire in EI conduit/GI conduit and painting. I-1, P-E1 , PWD Electrical Schedule |
| 40 | 2x1.5 sqmm wire in 19 mm conduit incl. S&F 1x14 SWG GI ECC (EI Conduit) |
| 41 | 2x2.5 sqmm wire in 19 mm conduit incl. S&F 1x14 SWG GI ECC (EI Conduit) |
| 42 | Supplying of different types of LED lamps (9W) I-5.3 F.25, P-113 , I & WD( M&E) Schedule |
| 43 | Havells make,NU Bulb Plus 9W 865 B22 3 Star |
| 44 | Supplying of approved make high speed ceiling fan (ISI marked) of following sizes having double ball bearing complete with standard down rod, canopy, hanging shackle,Aluminium blades,without regulator, AC 230-250 Volts. I-5.3 G.1, P-115 , I & WD( M&E) Schedule |
| 45 | 900mm/1050mm/1200mm |
| 46 | Opening the Ceiling Fan testing,Cheking and Re-Winding by supplying supper enamelled copper wire of appropiate gauge, minilex paper,mica sheet,changing the loops, over-hauling, backing, varnishing, re-fitting and using and measuring r.p.m for ceiling fan above 36\\" sweep upto 60\\" sweep. I-5.3 G.9, P-116 , I & WD( M&E) Schedule |
| 47 | Supplying of approved make exhaust fan heavy duty with mounting frame,blades AC 230-250 Volts. I-5.3 G.5, P-115 , I & WD( M&E) Schedule |
| 48 | 150mm Sweep RPM 900/1400 (6\\") |
| 49 | Comprehensive Annual Maintenance and servicing of Air conditioning machine of following ratings I-5.3 H.1, P-117 , I & WD( M&E) Schedule |
| 50 | 1.0 Ton split type |
| 51 | 1.5 Ton split type & cassette type both |
| 52 | Supply,Installation,testing & commissioning of suction/discharge copper pipe line in split air conditioning unit 1.0/1.5 TR/2 TR/3 TR capacity including brazing,nitrile rubber insulation 6/9 mm thick class 'O', etc complete as per required. I-5.3 H.4, P-117 , I & WD( M&E) Schedule |
| 53 | Copper tube 1/2\\" |
| 54 | Copper tube 3/8\\" |
| 55 | Gas charging (R410A/Eco Friendly Green Gas) of window/ split air conditioning unit including flushing of cooling & condensing units with nitrogen gas & rectification of leakage, replacement of filter,flair nut etc.if any. I-5.3 H.5, P-117 , I & WD( M&E) Schedule |
| 56 | 1.0 TR |
| 57 | 1.5 TR |
| 58 | Add GST 18 % ( CGST 9 % + SGST 9 %) |
| 59 | Add Cess 1 % Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysAug 20, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender