Tender For B.O.Q For Construction Of Foundation For 02 High Mast Lights Including Panel At General Bipin Rawat Stadium Baramulla
Tender Overview
Project Description
Tender for B.O.Q For Construction Of Foundation For 02 High Mast Lights Including Panel At General Bipin Rawat Stadium Baramulla
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 27-Jul-2026 | AddendumNIT93 | Technical Bid | 10-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means(Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), includingdressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil asdirected, within a lead of 50 m. |
| 2 | All soils 2x5.8x5.8x3.1 =208.57 cum |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: |
| 4 | 1:4:8 mix 2x4x4x.1=3.2 cum |
| 5 | Providing and laying in position specified grade of reinforced cement concrete, excludingthe cost of centering, shuttering, finishing andreinforcement - All work up to plinth level: |
| 6 | 1:1.5:3 mix (1.3*1.3*2.9)+(3.8*3.8*0.4))*2=21.35cum |
| 7 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing inposition, and binding all complete upto plinth level. |
| 8 | aThermo-Mechanically Treated bars of gradeFe-500D or more.12mm dia barsT1=40No.s *3.535m=141.4mT2=40No.s*3.94m=157.60mT432No.s*3.94m=126.08mTotal length=425.08m @0.89Kgs/m=378.32Kgs (A)8mm Dia Bars T3=18No.s *4992m=89.85m.39Kg/m=35.04Kgs (B) for 2 High masts 2*413.36Kgs=826.72Kgs |
| 9 | Centering and shuttering including strutting,propping etc. and removal of form for : |
| 10 | Foundations, footings, bases of columns, etc. for mass concrete(1.3*2.9)*4+(0.4*3.8)*4)*2 |
| 11 | Carriage of material far an avg lead of 20km sand |
| 12 | Carriage of material far an avg lead of 20km aggregates |
| 13 | Cables |
| 14 | Supply and laying of following sizes 1.1 KV FRLS XLPE insulated cable with copper/Al conductor, PVC inner sheathed, overall PVC sheathed stranded and twisted cable in conformity to the technical specification and as per latest IS - codes. |
| 15 | Supply and lying 3CX 2.5sqmm unarmoured CU cable |
| 16 | Supply and lying 4CX 25sqmm Armoured AL cable |
| 17 | Supply and lying 3.5CX 70sqmm armoured AL cable in existing DWC HDPE Pipe |
| 18 | Supply and lying 4CX 6sqmm Armoured AL cable |
| 19 | Conduit |
| 20 | SITC of 25 MM MS flexibale conduit |
| 21 | Termination |
| 22 | 3CX 2.5sqmm unarmoured CU cable |
| 23 | 4CX 25sqmm Armoured AL cable |
| 24 | 3.5CX 70sqmm armoured AL cable |
| 25 | Earthing |
| 26 | Supply and lying of Chemical/Maintenance free Earthing with complete accessories |
| 27 | Providing and fixing 25 mm X 3 mm G.I. strip from earth electrode, as required. |
| 28 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required |
| 29 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 30 | 120 mm dia (OD-120 mm & ID-103 mm nominal) |
| 31 | Supply testing and commissioning of 3 phase, 160KVA Unbalanced servostablizer with all necessary protection equipments as pe relevant standards TDS and GTP to be submitted for approval of engineer in charge before installation |
| 32 | Main Panel |
| 33 | supply ,Installation, testing and commissioning of IP 55 cubicle type outdoor Main Panel suitable for 415 volt, 3 phase, 4 wire 50 HZ AC supply system, fabricated in compartmentalized design from CRCA steel of 2 mm thick for frame work and covers, 3 mm thick for gland platees, including cleaning and finishing complete with 7 tank process having extensible type TPN aluminium alloy bus bar of high conductivity seperate for Servo stablizer and Generator supply with Change over switch of 200Ams and Servo bypass switch, with base frame of M.S. section of suitable size, copper earth bar of size 25mmx 5mm at the rear with 2 nos earth stud, complete with control wire, cable alleys, cable gland plates, including following items mentioned below. The panel should be suitable for Pedestrail mounting type 500mm above ground level with necessary base frame. The panels shall be designed for minimum expected ambient temperature of 52 degree Celsius, 100 percent relative humidity and dusty weather. design and drawing to be approved from engineer in charge before installation |
| 34 | INCOMER:- |
| 35 | 1 No. Adjustable 400A, TPN MCCB (36kA) with thermo magnetic releases and all required accessories like spreader links, extended rotatory handel and phase barriers. |
| 36 | 1 Set phase indication lights (R, Y, B) Solid state type (LED) |
| 37 | 1 No. 0 to 500V, AC, Volt Meter with VSS & control fuses. |
| 38 | 1 No. 0 to 200A, Ammeter with ASS &CT's. of ratio 200/5A and class-1 accuracy. |
| 39 | Outgoing |
| 40 | 4 Nos+1No. spare. 100A TPN MCCB (25kA) with thermo-magnetic releases. |
| 41 | 2 Nos. 63A TPN MCCB (25kA) with thermo-magnetic releases. |
| 42 | 4 Nos. 32A TPN MCB (10kA) 6 No. 16 Amp MCB DP (10kA) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 13 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender