Bids Are invited for Orthopaedic Battery Operated Drill System (V2) (Q2) - The Cannulated Battery Handpiece , The Diameter Of Cannulation 4 Mm , Weight Of Handpiece 1300 Gm With Battery , Power Of The System 170 W , Maximum Speed With Attachments 150
Tender Overview
Project Description
Bids Are invited for Orthopaedic Battery Operated Drill System (V2) (Q2) - The Cannulated Battery Handpiece , The Diameter Of Cannulation 4 Mm , Weight Of Handpiece 1300 Gm With Battery , Power Of The System 170 W , Maximum Speed With Attachments 1500 Rpm , There Separate Forward And Reverse Triggers , Handpiece Compatable With Radiolucent Drive , Instant Change Between Clockwise And Counterclockwise Rotation Possible , The System Fully Autoclavable , All Attachments Can Be Fitted On Single Handpiece , Reliable Protection Of Soft Tissue With Integrated Oscillation Mode , Power Module , Has Li-Ion Batteries, Control Unit & Motor Inside , Mode Selector Switch To Select Drilling/Reaming, Saw, Oscillating Drill Mode , There A Display Indicating The Battery Capacity Status , Button To Diagnose Errors In The System , Weight Of Module 500-700 Gm , Battery Litium Ion Battery With A Minimum Life Of 1000 Cycles , No Self Discharging Of Batteries And No Memory Effect There In The Batteries , The Capacity Of The Battery 1.2 Ah , Maximum Charging Time Between < 60 Min , Battery Voltage 20 -30V , Batteries Are Safe And Easy To Handle In The Operation Theatre , Lid For Hand Piece , Fully Autoclavable , Weight Of Lid 80 Gm , For Holding And Preventing Fall Of Power Module From The Hand Piece , Mode Selector Switch To Select Drilling/Reaming, Saw, Oscillating Drill Mode , Sterile Cover , Made Of Stainless Steel , Fully Autoclavable , For Sterile Transfer Of Power Module To Battery Hand Piece , Universal Battery Charger Ii , 4 Charging Bays , Capable Of Charging Nicd, Nimh And Lithium Ion Batteries , Display The Charging Status Of The Batteries , Keeps Inserted Batteries Constantly Fully Loaded , Ao/Asif Quick Coupling Attachment , Diameter Of Cannulation 2 Mm , Maximum Speed 1450 Rpm , Maximum Torque 3 Nm , Drill Chuck Attachment , Diameter Of Cannulation 4 Mm , Maximum Speed 1450 Rpm , Maximum Torque 3 Nm , Ao/Asif Quick Coupling For Medullary Reaming , Diameter Of Cannulation 4 Mm , Maximum Speed 330 Rpm , Maximum Torque 13 Nm , Quick Coupling For K-Wire , Continous Adjustment Facility For Wire Diameter From 1 To 4 Mm , Maximum Speed 1450 Rpm , Handpiece, Recon Sagittal Saw, With T-Handle, , Maximum Oscillating Frequency 11,000 Osc/Min. , The Litude Of Oscillation 4.5° , Saw Blade For Tjr Surgery Length 81 To 116 Mm, Usable L 60 To 95 Mm, Width 12.5 To 25 Mm, Thickness 0.89 To 1.47 Mm , Saw Blade For General Traumatology Length 46 To 90 Mm, Usable Length 25 To 69 Mm, Width 10 To 50 Mm, Thickness 0.4 To 1.2 Mm , Lid For Recon Sagittal Saw, , Fully Autoclavable , Weight Of Lid 80 Gm , For Holding And Preventing Fall Of Power Module From The Hand Piece , Sterilization Case , Should Be Of Same Make Of The Company Of The Product , Should Accommodate All Hand Piece, Attachment And Accessories For Autoclave In Their Respective Slots Made For Them , The Bidder Should Fix The Price Of The Blades Of Sagittal Saw (Small And Large), Blade Of Recirprocating Saw For Another 5 Years , Consumables, Accessories, Spare Parts Included In The Warranty Period (List To Be Provided) , Reusable Included In The Warranty Period (List To Be Provided) , Cmc 1St (3Rd Year) For All Above Items , Cmc 2Nd (4Th Year) For All Above Items , Cmc 3Rd (5Th Year) For All Above Items , Cmc 4Th (6Th Year) For All Above Items , Cmc 5Th (7Th Year) For All Above Items , Cmc 6Th (8Th Year) For All Above Items , Blade Of Sagittal Saw (Small) , Blade Of Sagittal Saw (Large) , Blade Of Recirprocating Saw
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | The Cannulated Battery handpiece | The Cannulated Battery handpiece |
| 2 | The diameter of cannulation 4 mm | The diameter of cannulation 4 mm |
| 3 | Weight of handpiece 1300 gm with Battery | Weight of handpiece 1300 gm with Battery |
| 4 | Power of the system 170 W | Power of the system 170 W |
| 5 | Maximum speed with attachments 1500 rpm | Maximum speed with attachments 1500 rpm |
| 6 | There separate forward and reverse triggers | There separate forward and reverse triggers |
| 7 | Handpiece compatable with radiolucent drive | Handpiece compatable with radiolucent drive |
| 8 | Instant change between clockwise and counterclockwise rotation possible | Instant change between clockwise and counterclockwise rotation possible |
| 9 | The system fully autoclavable | The system fully autoclavable |
| 10 | All Attachments can be fitted on single handpiece | All Attachments can be fitted on single handpiece |
| 11 | Reliable protection of soft tissue with integrated oscillation mode | Reliable protection of soft tissue with integrated oscillation mode |
| 12 | Power Module | Power Module |
| 13 | Has Li-Ion batteries, control unit & motor inside | Has Li-Ion batteries, control unit & motor inside |
| 14 | Mode Selector Switch to select Drilling/Reaming, Saw, Oscillating Drill mode | Mode Selector Switch to select Drilling/Reaming, Saw, Oscillating Drill mode |
| 15 | There a display indicating the battery capacity status | There a display indicating the battery capacity status |
| 16 | Button to diagnose errors in the system | Button to diagnose errors in the system |
| 17 | Weight of module 500-700 gm | Weight of module 500-700 gm |
| 18 | Battery Litium Ion battery with a minimum life of 1000 cycles | Battery Litium Ion battery with a minimum life of 1000 cycles |
| 19 | No self discharging of batteries and no memory effect there in the batteries | No self discharging of batteries and no memory effect there in the batteries |
| 20 | The capacity of the Battery 1.2 Ah | The capacity of the Battery 1.2 Ah |
| 21 | Maximum charging time between < 60 min | Maximum charging time between < 60 min |
| 22 | Battery voltage 20 -30V | Battery voltage 20 -30V |
| 23 | Batteries are Safe and easy to handle in the operation theatre | Batteries are Safe and easy to handle in the operation theatre |
| 24 | Lid for Hand piece | Lid for Hand piece |
| 25 | Fully autoclavable | Fully autoclavable |
| 26 | Weight of Lid 80 gm | Weight of Lid 80 gm |
| 27 | For holding and preventing fall of Power Module from the Hand piece | For holding and preventing fall of Power Module from the Hand piece |
| 28 | Mode Selector Switch to select Drilling/Reaming, Saw, Oscillating Drill mode | Mode Selector Switch to select Drilling/Reaming, Saw, Oscillating Drill mode |
| 29 | Sterile Cover | Sterile Cover |
| 30 | Made of Stainless steel | Made of Stainless steel |
| 31 | Fully autoclavable | Fully autoclavable |
| 32 | For sterile transfer of Power Module to Battery Hand piece | For sterile transfer of Power Module to Battery Hand piece |
| 33 | Universal Battery Charger II | Universal Battery Charger II |
| 34 | 4 charging bays | 4 charging bays |
| 35 | capable of charging NiCd, NiMh and Lithium Ion batteries | capable of charging NiCd, NiMh and Lithium Ion batteries |
| 36 | Display the charging status of the batteries | Display the charging status of the batteries |
| 37 | Keeps inserted batteries constantly fully loaded | Keeps inserted batteries constantly fully loaded |
| 38 | AO/ASIF Quick Coupling attachment | AO/ASIF Quick Coupling attachment |
| 39 | Diameter of cannulation 2 mm | Diameter of cannulation 2 mm |
| 40 | Maximum Speed 1450 rpm | Maximum Speed 1450 rpm |
| 41 | Maximum Torque 3 Nm | Maximum Torque 3 Nm |
| 42 | Drill Chuck attachment | Drill Chuck attachment |
| 43 | Diameter of cannulation 4 mm | Diameter of cannulation 4 mm |
| 44 | Maximum Speed 1450 rpm | Maximum Speed 1450 rpm |
| 45 | Maximum Torque 3 Nm | Maximum Torque 3 Nm |
| 46 | AO/ASIF Quick Coupling for Medullary Reaming | AO/ASIF Quick Coupling for Medullary Reaming |
| 47 | Diameter of cannulation 4 mm | Diameter of cannulation 4 mm |
| 48 | Maximum Speed 330 rpm | Maximum Speed 330 rpm |
| 49 | Maximum Torque 13 Nm | Maximum Torque 13 Nm |
| 50 | Quick Coupling for K-wire | Quick Coupling for K-wire |
| 51 | Continous adjustment facility for wire diameter from 1 to 4 mm | Continous adjustment facility for wire diameter from 1 to 4 mm |
| 52 | Maximum Speed 1450 rpm | Maximum Speed 1450 rpm |
| 53 | Handpiece, Recon Sagittal Saw, with T-Handle, | Handpiece, Recon Sagittal Saw, with T-Handle, |
| 54 | Maximum oscillating frequency 11,000 osc/min. | Maximum oscillating frequency 11,000 osc/min. |
| 55 | The amplitude of oscillation 4.5° | The amplitude of oscillation 4.5° |
| 56 | Saw Blade for TJR Surgery Length 81 to 116 mm, Usable L 60 to 95 mm, Width 12.5 to 25 mm, Thickness 0.89 to 1.47 mm | Saw Blade for TJR Surgery Length 81 to 116 mm, Usable L 60 to 95 mm, Width 12.5 to 25 mm, Thickness 0.89 to 1.47 mm |
| 57 | Saw Blade for General Traumatology Length 46 to 90 mm, Usable Length 25 to 69 mm, Width 10 to 50 mm, Thickness 0.4 to 1.2 mm | Saw Blade for General Traumatology Length 46 to 90 mm, Usable Length 25 to 69 mm, Width 10 to 50 mm, Thickness 0.4 to 1.2 mm |
| 58 | Lid for Recon Sagittal Saw, | Lid for Recon Sagittal Saw, |
| 59 | Fully autoclavable | Fully autoclavable |
| 60 | Weight of Lid 80 gm | Weight of Lid 80 gm |
| 61 | For holding and preventing fall of Power Module from the Hand piece | For holding and preventing fall of Power Module from the Hand piece |
| 62 | Sterilization Case | Sterilization Case |
| 63 | Should be of same make of the company of the product | Should be of same make of the company of the product |
| 64 | Should accommodate all hand piece, attachment and accessories for autoclave in their respective slots made for them | Should accommodate all hand piece, attachment and accessories for autoclave in their respective slots made for them |
| 65 | The bidder should fix the price of the blades of sagittal saw (small and large), blade of recirprocating saw for another 5 years | The bidder should fix the price of the blades of sagittal saw (small and large), blade of recirprocating saw for another 5 years |
| 66 | Consumables, accessories, spare parts included in the warranty period (list to be provided) | Consumables, accessories, spare parts included in the warranty period (list to be provided) |
| 67 | Reusable included in the warranty period (list to be provided) | Reusable included in the warranty period (list to be provided) |
| 68 | CMC 1st (3rd Year) for all above items | CMC 1st (3rd Year) for all above items |
| 69 | CMC 2nd (4th Year) for all above items | CMC 2nd (4th Year) for all above items |
| 70 | CMC 3rd (5th Year) for all above items | CMC 3rd (5th Year) for all above items |
| 71 | CMC 4th (6th Year) for all above items | CMC 4th (6th Year) for all above items |
| 72 | CMC 5th (7th Year) for all above items | CMC 5th (7th Year) for all above items |
| 73 | CMC 6th (8th Year) for all above items | CMC 6th (8th Year) for all above items |
| 74 | Blade of sagittal saw (small) | Blade of sagittal saw (small) |
| 75 | Blade of sagittal saw (large) | Blade of sagittal saw (large) |
| 76 | Blade of recirprocating saw | Blade of recirprocating saw |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender