Tender For Operation And Maintenance Of Electromechanical Services At Door Sanchar Bhawan Compound, Link Road, Cuttack (For The Financial Year 2026-27).(Sub Head:- Miscellaneous Electrical Maintenance Works Not Included In The O&M Contract).
Tender Overview
Project Description
Tender for Operation And Maintenance Of Electromechanical Services At Door Sanchar Bhawan Compound, Link Road, Cuttack (For The Financial Year 2026-27).(Sub Head:- Miscellaneous Electrical Maintenance Works Not Included In The O&M Contract).
BOQ
| Sl. No. | Item Description |
| 1 | SUB HEAD - I |
| 2 | Replacement of damaged miniature circuit breaker by supplying and fixing 6A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make-Legrand/L&T/Siemens/Schneider) |
| 3 | Single pole |
| 4 | Replacement of damaged isolators by supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 5 | Replacement of damaged isolators by supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make-Legrand/ L&T/ Siemens/ Schneider) |
| 6 | 100 A |
| 7 | Replacement of the following burnt out/damaged cable/wires/lugs/sockets etc. by new one of following types, sizes and ratings FRLSH/HFFR PVC insulated single core (unsheathed) bright annealed copper conductor multistrand flexible cable for voltage grade up to 1100V as per IS694:2010 i/c laying / drawing in existing conduit/pipe, connection, testing etc. as required. |
| 8 | 1 x 1.5 sq. mm |
| 9 | 10 x 1.5 sq. mm |
| 10 | Replacement of the burnt-out cables/wirings by the following sizes FR PVC insulated & PVC round sheathed multicore bright annealed bare copper conductor flexible cable for voltage grade up to 1100volts as per IS-694-2010 i/c fixing/laying on wall/ceiling with C clamps etc. as required. |
| 11 | 3 coreX1.5sqmm |
| 12 | 3 coreX2.5sqmm |
| 13 | Replacement of faulty and damaged FTL fittings by new one of following ratings, 65000K Cool Day Light suitable for operation on 140 volts to 270 volts AC, 50Hz i/c fixing and connection etc. as required. |
| 14 | 20/22 watt 65000K LED Batten Polycarbonate/Aluminium body. (Make-(Philips Ujjwal 20-Watt LED Batten / Equivalent model of Surya / Polycab / Crompton) |
| 15 | 20W 4ft ultra bright LED Tube light with very high efficacy 2100Lumen, 6500K & THD<15%, single side wiring suitable for installation in existing FLT fixtures having G13 lamp holders in replacement of conventional fluorescent tubes. faulty LED tubes i/c connection etc. as required. (Make-Phillips/Bajaj/Crompton/Havells). |
| 16 | Replacement of the lamp holders/ceiling roses etc. by new ones of reputed makes etc. as required. |
| 17 | 36 /40-watt Fluorescent Tube rods |
| 18 | 36/40-watt electronic ballast for Fl. Tube fittings |
| 19 | 9 /10-watt LED Lamp (B22) |
| 20 | 14/15-watt BC LED Lamp (B22/E27) |
| 21 | 20-watt LED Lamp (B22) |
| 22 | Starter for Fl. Fittings |
| 23 | 5/6Amps 250 Volts 3 pin Plug top |
| 24 | Supplying and fixing following modular type / Piano type switch/ socket on the existing modular plate/switch box including connections etc. as required. |
| 25 | 7\\"x5\\" PVC box |
| 26 | 4\\"x4\\" PVC box |
| 27 | Supplying and fixing of computer board consistinst of 4 nos Piano type switch, 4 nos piano type socket, 1 no fuse and 1 no indicator fixed on a suitable size PVC Box and hylum sheet cover etc complete as required. |
| 28 | Supplying and fixing following modular type / Piano type switch/ socket on the existing modular plate/switch box including connections etc. as required. |
| 29 | 16/20A Modular switch |
| 30 | 6 pin 16/20A Modular socket |
| 31 | Ding Dong Bell |
| 32 | Call Bell |
| 33 | 6 /10 Amps 1 way piano type switch |
| 34 | 20 Amps 1 way piano type switch |
| 35 | 6 Amps 3 pin piano type socket |
| 36 | 16 Amps 3 pin piano type socket |
| 37 | Replacement of faulty and unserviceable Ceiling Fan/wall mountingf fan by new ones of following specifications i/c installation, connection and testing etc. as required. (Havells Andria/Ambose ES/Artemis with 2 years warranty Or Equivalent of Usha/Bajaj/Crompton) |
| 38 | 1200mm sweep ceiling fan, 3nos aluminium blades, ISI marked minimum 1-Star rated, copper wound induction motor, 350RPM, min air delivery 226m3/min, powder coated with 260mm down rod suitable for operation on 230V 50HZ AC supply |
| 39 | 400mm sweep wall mounting fan, ISI marked minimum 1-Star rated, copper wound induction motor, 350RPM, min air delivery 226m3/min, powder coated with 260mm down rod suitable for operation on 230V 50HZ AC supply |
| 40 | Rewinding of 1200mm/1400mm ceiling fan by superior quality super enameled copper conductor i/c heat varnishing, testing etc. as required. |
| 41 | Replacement of the defective Capacitors / Fan regulators/ bearings for ceiling fans etc. by the new one of following ratings etc. as required. (Make- Anchor/Havells/Cona/ISI) |
| 42 | Stepped type Electronic Fan Regulator (Switch type) |
| 43 | 2.25 mfd 440 volts Capacitor for Ceiling Fan |
| 44 | Bearings for Ceiling fans (6201 & 6202) etc. as required. (Make: SKF/SS) |
| 45 | S/F of MCB protected Socket outlet 4 module with metal box comprising of 01no. 25Amps socket and 01no. 25Amps Plug and 01no. 25Amps \\"C\\" series SPMCB for Split AC units i/c connection, testing etc. as required. (Make- Legrand /Havells/HPL/Standard) |
| 46 | Replacement of burn out Sockets/lugs of cables by new ones of following types and sizes i/c dismantling the burnt out portion of cables/wires, crimping/fixing of new sockets/lugs etc. (Dowell's / Comet / Hex Connect well / SS) |
| 47 | For 50/70sqmm Al Conductor Armoured cable |
| 48 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 49 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (Make-Legrand/L&T/Siemens/Schneider) |
| 50 | 8 way with metal door (IP43) |
| 51 | Dismantling of the existing damaged exhaust fans from the ladies/Gents Toilets/ IQ Toilets and I/T/C of exhaust fan upto 450mm. sweep in the existing opening i/c transportation charges from BSNL Electrical Division Office at Cantonment Road, making good the damages, connection, testing etc. as required. |
| 52 | Extra for fixing the louver/shutter complete with frame for exhaust fan as required. |
| 53 | Dismantling of the existing damaged 2x40 watt SMO Fittings and I/T/C of pre-wired fl. fittings of all types complete with all accessories & tubes etc.as per following manner i/c transportation charges from Telephone Bhawan connection with 1.5 sq.mm. PVC insulated cu. conductor single core cable as required. |
| 54 | a) Directly on ceiling/wall. |
| 55 | Dismantling of the existing fan fittings from the TRA section and shifting the same to the DG Room as per the instruction of DGM City and Civil wing for the required modification work for handing over the Rooms for lease out purpose etc complete as required. |
| 56 | Note:- During preparation of the above estimate labour rates for consumable items have not been considered as there is an O&M Contract. |
| 57 | SUB HEAD -II (Supply of Store materials) |
| 58 | FAN EXHAUST 12\\"(300MM) - 16 nos |
| 59 | FITING TUBE LIGHT WEATHER PROOF 1X40W - 20 nos Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender