Tender For Construction Of Block Level Mission Shakti Bhawan (Subhadra Sakti Kendra) At Mouza-Bhoi Nagar, Unit-9 (F), Back Side Of Census India Building (G) In The District Of Khordha
Tender Value
65.46 Lakhs
Estimated cost
Bid Submission
06 Aug 2026
2 days left
EMD
65470
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Khordha → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Block Level Mission Shakti Bhawan (Subhadra Sakti Kendra) At Mouza-Bhoi Nagar, Unit-9 (F), Back Side Of Census India Building (G) In The District Of Khordha
BOQ
| Sl. No. | Item Description |
| 1 | CIVIL PORTION - Clearing and grubbing roads and land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness. |
| 2 | Earth work in excavation in foundation trenches, column foundation, pit, etc in all kind of soil including moorum stony earth and earth mixed with boulders except sheet rock and boulders not requiring blasting including dressing of sides and levelling the bed up to the required depth and depositing the excavated materials away from the work site with initial lead of 50 mtr and all lifts, including shoring, shuttering & dewatering (if required) with cost of labour, labour cess, hire & running charges of all machineries, sundries & T&P required for the work complete as directed by the Engineer in charge. Upto 1.5mtr Depth |
| 3 | Disposal of surplus/ excavated materials by mechanical means within 5km. Lead away from the site including cost of all labour , T&P complete as per the direction of the Engineer-in-charge. Ground Floor |
| 4 | Filling the Foundation and Plinth, sides of foundation, etc. with excavated materials (excluding rock), in layers not exceeding 0.225 m in depth including cost of watering, ramming, dressing and levelling the top to proper level & gradient, cost of labour, conveyance, loading, unloading, T&P, etc, all complete as per the direction of Engineer-in-Charge. Ground Floor |
| 5 | Supplying, diluting and preparing chemical emulsion like Imidacloprid 30.5 % SC or other chemicals approved by Central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as Pre-Constructional Anti-termite Treatment confirming to IS 6313 (Part-II) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. at the rate of 7.5 liters per sqm on vertical surface and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150mm center to center (or as directed by the manufacturer) including the cost of all materials, cost of all labour, conveyance, loading, unloading, T&P, etc. all complete as per the direction of Engineer-in-Charge. ( The payment shall be made on the basis of actual plinth area of the building at ground floor and vertical faces will not be measured for payment). Note- The contractor shall have to furnish Ten (10) years guarantees to maintain the anti-termite treated area / structure free from termite. In addition to the 10 years guarantee furnished as above, the contractor shall have to furnish ten years (after certificate of final completion) Bank Guarantee Bond issued by any Nationalized Bank executed in favour of the client as directed in the prescribed proforma available in the tender document for an amount of 10% (ten percent) of cost of this item of work. |
| 6 | Supplying and Filling with Sand in Foundation and Plinth in layers not exceeding 20 cm in depth, well watered and compact , top surface dressed and levelled to proper level and gradient including cost of all materials , conveyance,taxes, royalties, loading, unloading, cost of all labour, T&P, etc.All compelete as per the dirrection of Engineer-in-charge. Ground Floor |
| 7 | Providing and lying Plain Cement Concrete of proportion (1:3:6) in foundation & floor using 40 mm & down grade black hard crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -charge. Ground Floor |
| 8 | Providing, lifting, hoisting and laying in position Machine Batched , Machine Mixed and Machine Vibrated Design mix Cement Concrete of M-25 Including the cost of Centering and Shuttering (minimum cement content not less than 403Kg/Cum) grade in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance, loading, unloading, royalties, watering and curing for the required period, T&P , hire & running charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions ( as per IS 9103 ) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-charge but excluding the cost of steel reinforcement.(A)R.C.C. Pile cap and footing bases of columns mass concrete pre-cast slab etc. Ground Floor- |
| 9 | (B)R.C.C. Plinth Beam-Ground Floor |
| 10 | (C)R.C.C. Beams, columns, grider and bressmer etc. Ground Floor |
| 11 | Terrace Floor |
| 12 | (D)R.C.C. Floor and Roof slab, landing, balconies,Projecting sun shadesup to 4.3Mtr. Height. Ground Floor |
| 13 | Terrace Floor |
| 14 | (E)R.C.C. chajjas. Ground Floor |
| 15 | Terrace Floor |
| 16 | (F)R.C.C. Lintel-Ground Floor |
| 17 | Terrace Floor |
| 18 | (G)R.C.C. R.C.C. stairs excluding landing but including railing. Ground floor- |
| 19 | Providing & fixing TOR Fe-500 HYSD Reinforcement bars of required diameter and approved quality for Reinforced Cement Concrete work including straightening, cutting, bending, binding, welding(if approved) , joining (if necessary), tying the grills, hoisting, lowering and placing in position as per the approved design & drawings (BBS) with provision of standard fan hooks including the cost of all materials, cost of all labour, conveyance, loading, unloading, cost of binding wires of 18 to 20 gauge, T&P, etc, all complete as per the direction of Engineer-in-Charge. Note: (Linear measurements will be taken & quantity will be calculated on standard weight. Lap length of bars & Weight of binding wire will not be considered for measurement and payment).Ground Floor |
| 20 | Terrace Floor |
| 21 | Providing and laying Brick Masonry work in Foundation & Plinth using Fly ash bricks of 25 Cm. x 12 Cm. x 8 Cm. size having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 % confirming to IS 12894 and IS 2212 in cement mortar (1:4) affter immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge. Ground Floor |
| 22 | Providing and laying Brick masonry work in Superstructure using Fly ash bricks of 25 Cm. x 12 Cm. x 8 Cm. size having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 % confirming to IS 12894 and IS 2212 in cement mortar (1:4) for Half Brick Masonry Wall with provisions for 2 nos 6mm dia MS bar at each 4th layer after immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge. ( Excluding Cost Of Steel Reinforcement ) Ground Floor |
| 23 | Providing and laying of Full Brick Masonry work in Superstructure using Fly ash bricks of 25 Cm. x 12 Cm. x 8 Cm. size having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 % confirming to IS 12894 and IS 2212 in cement mortar (1:6) affter immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge. Ground Floor |
| 24 | Terrace Floor |
| 25 | Providing 6 mm thick Cement Plaster in Cement Mortar of (1:4) to Ceilings of Roof Slabs, Stairs, Landings, Chajja, Shelves, Columns, Beams and Lofts etc. including roughening, scraping and cleaning and finishing the plastered surface smooth using wooden floats only to proper plumbs and level, making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading and royalties, all labour, scaffolding, watering and curing , sundries, T&P etc. complete as per direction of the Engineer-in-charge. Ground Floor |
| 26 | Terrace Floor |
| 27 | Providing 12mm thick Cement Plaster to the Surface of Brick Masonry Wall in Cement Mortar (1:6) including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading and royalties, all labour, scaffolding, watering and curing, sundries and T&P etc. complete as per direction of the Engineer-in-charge. Ground Floor |
| 28 | Terrace Floor |
| 29 | Providing 16mm thick cement plaster in cement mortar (1:6) to the surfaces of brick masonry wall including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, royalties, cost of labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge. Ground Floor |
| 30 | Terrace Floor |
| 31 | Providing average 25mm thick grading Concrete in C.C ( 1:2:2 ) using 6mm size crusher broken black hard granite chips using 2% water proofing cement compound (Make: Sika / Fosroc / Equivalent) after scraping and cleaning the roof surface and finishing smooth to proper slope and gradient including cost of all materials, conveyance, sundries,T&P watering and curing by ponding water over terrace slab etc. complete as per the direction of the Engineer-in-charge. Terrace Floor |
| 32 | Supplying and finishing the plastered surface of wall using Cement Based Wall Putty (Water Based) of approved make and quality and finished smooth and even surface to receive the paint including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, scaffolding, T&P, etc, all complete as per the direction of Engineer-in-Charge. (Make: Birla White/J K Wall Putty),Internal Wall Putty,Ground Floor |
| 33 | Terrace Floor |
| 34 | Providing and applying Two Coats Plastic Emulsion Paint of approved make, quality and shade over a coat of wall primer of approved quality to the internal plastered surfaces including throughly brushing the surface to make free from foreign materials, sand papering, priming including cost of all materials, cost of all labour, conveyance, loading, unloading, scaffolding, staging, watering and curing, T&P etc. complete as per the direction of the Engineer-in-charge. (Note: Colour & shade to be approved before procurment & use).(Make:Dulux/Nerolac/Berger/Asian Paint) Ground Floor |
| 35 | Terrace Floor |
| 36 | Providing and Painting with Two Coats Weather Coat Paint (exterior grade) of approved make & shade manufactured by reputed manufacturer make an even finished surface over a coat of water bound cement primer in all heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete. (Make: Dulux/ Nerolac/Berger/Asian Paint) Ground Floor |
| 37 | Terrace Floor |
| 38 | Providing and painting Two Coats of Synthetic Enamel Paint of approved quality, brand and shade to Iron Work including cost, conveyance, royalties , cost of all labour, labour cess, T&P etc. required for the work complete as directed by the Engineer-in-Charge. (Note: Colour & shade to be approved before procurment & use).(Make:Dulux/Nerolac/Berger/Asian Paint) Ground Floor |
| 39 | Terrace Floor |
| 40 | Providing and laying of 600 mm x 600 mm Matt Finished Vitrified Floor Tiles confirming to IS : 15622 of approved make, quality and colour without any warpage laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with acid including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of tiles shall be approved before procurement and use.) (Make:Somany/Jhonson/RAK/Kajaria) Ground Floor |
| 41 | Providing and laying of Vitrified Wall Tiles in dado/skirting confirming to IS : 15622 of approved make, quality, colour and size 600mm x600mm upto required height from floor level fixed over an under layer of 12mm thick bed of cement mortar (1:3) (1 Cement : 3 Coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (Make:Somany/Jhonson/RAK/kajaria) Ground Floor |
| 42 | Providing & laying granite stone flooring in Floors and landing using 19 mm thick granite stone slab of approved quality, colour and size above 0.4 Sqm as per IS 14223 laid over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) confirming to IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. Ground Floor |
| 43 | Terrace Floor |
| 44 | Providing & laying granite stone tiles in dado/skirting using 10mm thick granite stone slab of approved quality, colour and size above 0.4 Sqm as per IS 14223 to proper line, level and slope laid over 12mm thick cement mortar (1: 3) confirming to IS IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of tiles shall be approved before procurement and use.) Ground Floor |
| 45 | Terrace Floor |
| 46 | Providing 25 mm thick A.S. flooring with base C.C. (1:2:4) using 20 mm size hard granite crusher broken chips after roughening, scraping, cleaning the base, watering well and laying flooring to required level in panels 2m x 2m (Max.) by using dividing glass strips of 40 x 4 mm size, well compacted and top finishing smooth by trowel with a thick coat of neat cement punning, polished well including cost of all materials, labour, conveyance, sundries, T&P, curing etc. complete as per direction of Engineer-in-Charge. Ground Floor |
| 47 | Supplying, fitting & fixing of well dressed and seasoned sal wood choukath of approved size wrought and put up in door frame including two coat of coaltaring to wall and lintel side faces, in all floors including cost, conveyance, cost of all labour, labour cess, T&P etc. complete as directed by Engineer-In-Charge. Ground Floor |
| 48 | Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete Ground Floor |
| 49 | Terrace Floor |
| 50 | Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures.(S/R-2022,Page No-235,Item No-12) Ground Floor |
| 51 | Terrace Floor |
| 52 | Supplying, fitting & fixing of M.S. Grill made out of M.S. flats/square bars as per drawing and design fixed in position to proper plumb, including a coat of priming with approved quality metallic primer, materials including cost, conveyance, taxes, transportation of all materials, cost of all labour, sundries, T&P etc. complete as per direction of Engineer in charge. Ground Floor |
| 53 | Terrace Floor |
| 54 | Supplying, fabricating & fixing of polished stainless steel (304 grade) items made out of pipes, angles, flats, plates, hollow tube, square pipe bracing as per approved design and specification, buffing, polishing etc. with cost, conveyance, labour in railing, parapet, staircase, space frame etc required for the work complete in all respect as per direction of Engineer-in-charge. Ground Floor |
| 55 | Providing & fixing 8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process. false ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x10 x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45 x15 x 0.90mm running at the spacing of 1200 mm c/ c, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of dry wall screws of size 3.5 x25mm at 230mm c/c, including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes,finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufacture's specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specificaton and direction of the Engineer in charge but excluding the cost of painting . |
| 56 | Supplying and fixing of Roller blinds by fixing powder coated top channel, bottom channel with bottom end cap, control unit and good quality of 0.60 mm thick fabric of approved design and quality etc. complete. |
| 57 | Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP - 63:2018. |
| 58 | Construction of granular sub-base by providing Grading-VI Material as per table 400-2, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with |
| 59 | ELECTRICAL PORTION - Circuit Cum wiring - Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) Make-Schneider(Zencelo)/legrand(Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. Group-B |
| 60 | Group-C |
| 61 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 62 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (flame retradant type)) with suitable size modular box & cover( falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 63 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)((flame retradant type)) with suitable size modular box & cover(flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 64 | Supplying and installation of AC Point having 16-25A DP MCB, C series with enclosure, Schneider/Siemens/Legrand/ABB c of suitable size as required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 1 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 65 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 66 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 67 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 68 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(LFDB TO LBDB/UBDB) (2X6+1X2.5) |
| 69 | Recessed wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(4X6+2X4) |
| 70 | Fan & Indoor fixtures - SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 71 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 10-18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 72 | Supplying an fixing of recess/surface mounted 2'x2' 36 W(595mmx595mmx70mm) square shaped LED with lumen efficacy not less than 130lm/W, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty) as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 5years. |
| 73 | SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years |
| 74 | Supplying, Erection, Fixing, connection & testing of LED BOUNDRY WALL Light of elegant look (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) 60 W LED street light having die cast aluminium housing with toughened glass having lumen efficacy of 110 lm/w or more (As per LM 79 report of third party NABL lab) ,IP 65 protection or more , LED street light model having warrantied for a period of 5 years . The luminaire should be supplied along with bracket maintenance free for inspection as required as per direction of Engg.-in-Charge. |
| 75 | Supplying, Erection, Fixing, connection & testing of wall mounted 10W LED Bulkhead wall fitting of Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj. The luminaire should be Replacement Warranty will be 2 years |
| 76 | Supplying, installation, testing and commssioning of 1200 mm sweep Copper wound BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery 215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix /Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years. |
| 77 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 78 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge (Make: legrand Myrius /Schneider(Zencelo)/Panasonic(Vision)) |
| 79 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge . (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. |
| 80 | Panels, MDBs, DBs, MCBs - Main Distribution Board - S/I/T & Commissioning of LT indoor/outdoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 3 mm CRCA steel sheet duly derusted & painted by siemens gray powder cote paint is designed as G.A drawing as per direction of Engg.-in-Charge.Warrenty period of replacement of panel & accessories must be 1 years & compelete test certificate must be submitted along with panel board including component list. ON/OFF/TRIP indication for all the incoming and outgoing feeders.50X10MM Separate Aluminium Earth bus bar should be installed. Make of MCCB- ABB(Formula)/Siemens (3VA)/ SCHNEIDER(CVS)/ Legrand(DPX3). Make of MCB- ABB(SB 200) /Siemens (Betaguard)/ SCHNEIDER(Acti 9 AN9)/ Legrand(DX3) Incomer-1-01 number of 63A 4P Icu=100%Ics, 36Ka LSIG MCCB with micro processor based release Electrical locking for normal & DG ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS (FROM TRANSFORMER) Incomer-2-01 number of 63A 4P Icu=100%Ics, 36Ka LSIG MCCB with micro processor based release Electrical locking for normal & DG ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS) From DG 1 no. 63A onload change over. Make-Legrand/ABB/Siemens/Schneider Busbar- 04 numbers of 100 Amps AL bus bar Electrolytic busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. Out going- 08 numbers of 40A 4P MCB 10kA, C series. ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB-FORMULA) Instrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) Digital Meter Displays Current, line to neutral & line to line Voltages, frequency & Power Factor. (VA & PF - Phase Wise & Average) (SECURE/ Legrand ) for all the incomers (ii) 02 set of 4 pole (3P+N) 65 KA SPD type 1+2 with 63 A 4 P Mcb, C series 10kA (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard)/ABB SB200 - PANEL AS ABOVE - |
| 81 | DBS - Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years (a) 4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(FOR LIGHT,POWER INDOOR,3-PH,POWER LOAD) Warranty on DB is 3 years. |
| 82 | 8 Way(8+24) Way TPN MCB DD DB Horizontal Type suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(FOR POWER & INDOOR AC DB)Warranty on DB is 3 years. |
| 83 | Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 230 volts, MCB . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 year.. |
| 84 | Supplying and fixing 40 amps rating, 415 volts, C series,10KA breaking capacity, FOUR poles MCB of Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9 /ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 1 year. |
| 85 | Supplying and fixing 40 Amps rating, RCCB 30mA . Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. . The RCCB should be Replacement Warranty will be 1 year. |
| 86 | Cables, Cable Laying & Termination - Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. (a) 3C X 6 sqmm |
| 87 | 4C X 16 sqmm |
| 88 | LAYING OF CABLE - Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand cushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 89 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface/tray with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 90 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 120 SQ. MM From 25 SQ. MM in surface/tray with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 91 | TERMINATION OF CABLES - Supply & Making end Termination with brass compression gland and Cu/aluminium lugs for PVC insulated and PVC sheathed cable of 1.1 kv grade (without cost of Cable) 3C X 6 sqmm(19 mm) |
| 92 | 4C X 16 sqmm(28mm) |
| 93 | Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. 110 mm dia (OD-110 mm & ID-97 mm nominal) |
| 94 | EARTHING SYSTEM - /IT/C of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 95 | Providing and fixing 25mm x 6 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 96 | Supply, Installation, testing & Commissioning of Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 97 | Supplying and laying 25 mm X 6 mm G.I strip at 0.50 metre below ground & open surface as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm). |
| 98 | Supplying and laying 6 SWG G.I. wire at existing trench & open surface for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 99 | EXTERNAL LIGHTING - Supplying, Erection, Fixing, connection & testing of 40W LED GATE Light of (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) maintenance free having 2 years warranty G.I P ipe with braket including MCB box & including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge. |
| 100 | EXTINGUISHER SYSTEM - Providing and fixing of 4.5 kg carbon-di-oxide type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS : 2878 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.Make- Safex/ Fireshield/Kanex/ Ceasefire . |
| 101 | Supplying, installation, testing and commissioning of ABC type fire extinguishers of 6 kg capacity including cost of all material & labour etc complete. Make-Safex/Fireshield/Ceasefire |
| 102 | Miscellaneous Items - Supplying 11 kV hand gloves as reqd. |
| 103 | Supplying and Laying Rubber mat 1M X 2M X 2.0MM thick to withstand 1.1 KV dielectric strength, Electrical Safety/Shock Chart & SLD etc as required. |
| 104 | P.H. PORTION - Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipes confirming to CPVC/UPVC ASTM-D- 1785/89 (Sch-80) and pipe fittings of the following nominal borewith clamps including making good the wall , ceiling and floor, testing all complete as per specification and direction of the Engineer in charge.(Supreme/Ashirvad/Oriplast/AKG) In ground floor 20 mm CPVC pipes |
| 105 | 25 mm CPVC pipes |
| 106 | Supplying all materials, labour,T&Pand providing and fixing to wall or ceiling and floor pvc pipes conforming to ASTM-D-1785/04 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge upreme/Ashirvad/ Oriplast/ AKG) Ground Floor 25mm PVC ASTM (Sch-80) Pipe |
| 107 | 32mm PVC ASTM (Sch-80) Pipe |
| 108 | 1st Floor 50mm PVC ASTM (Sch-80) Pipe |
| 109 | supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings etc. all complete as per P.H. specification and direction of E.I.C.250 mm thick wall in GF |
| 110 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages as per direction of the E.I.C. |
| 111 | Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge. (below model or equivalent of any brand) 15mm dia CP two way bib cock(CON-CHR-041KN) |
| 112 | 15 mm dia CP Sink cock(CON-CHR-347FKN) |
| 113 | 15mm dia CP angle stop cock(CON-CHR-053KN) |
| 114 | 15mm dia CP Health faucet.ALD-CHR-579 |
| 115 | 15mm dia CP Pillar cock (Jaquar)CON-CHR-021KN |
| 116 | 15mm dia CP flange |
| 117 | 15mm Cp extention piece |
| 118 | 125mmdia C.P.grating |
| 119 | 25mm dia C-PVC ball valve.(Ashrivad make) |
| 120 | 32mm dia C-PVC ball valve.(Ashrivad make) |
| 121 | 50mm dia C-PVC ball valve.(Ashrivad make) |
| 122 | 600mm X 125mm C.P glass shelf (ACN -CHR-1171N) |
| 123 | CP towel rail (25 mm)(ACN-CHR-1111N) |
| 124 | C.P towel ring(ACN-CHR-1121NMI) |
| 125 | CP soap Dish holder (ACN-CHR-1131N) |
| 126 | Supplying all materials, labour, T&P and fitting and fixing 10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge 10 litres capacity pvc low level cistern (Slimline-white) |
| 127 | Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class K.B brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 3.18m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge 2000litre capacity water storage tanks(3 layer)(Sintex make) (1st Floor) |
| 128 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturers specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge(Supreme/ Ashirvad/ Oriplast/AKG) 10mm dia U-PVC SWR pipes |
| 129 | 110mm U-PVC door Tee |
| 130 | 110mm U-PVC plain Tee |
| 131 | 110mm U-PVC door bend |
| 132 | 110mm U-PVC plain bend |
| 133 | 110mm dia U-PVC off set |
| 134 | 110mm dia U-PVC 'P' trap |
| 135 | 110mm dia U-PVC cowl |
| 136 | 110mm dia U-PVC clamp |
| 137 | 75mm dia U-PVC SWR pipes(Supreme/Ashirvad) |
| 138 | 75mm U-PVC door bend |
| 139 | 75mm U-PVC plain bend |
| 140 | Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI/PVC SWR pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge 250mm to 375mm thick wall |
| 141 | Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x 30mm footrest, fixing 100mm dia HCI P or S trap (with/without 50mm dia horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc all complete as per specification and direction of the Engineer in charge 580mm size Orissa pan (Parryware/Cera/ Nycer Make) |
| 142 | Supplying all materials,labour,T&P and fixing the following vitreous china wash down water closet(European type W.C.pan) with integral P or S trap to the fllor with wooden plugs and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar(1:1)fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc.all complete as per specification and direction of the Engineer-in-charge. E.W.C. S trap with seat cover (Parryware/Hindware) |
| 143 | Supplying all materials, labour, T&P and fixing bowl pattern urinal conforming to IS:771-part-3-1985 of the following sizes including connecting the urinal with 32mm dia pvc waste pipe 910mm long by means of white lead mixed with chopped hemp, fixing 32mm dia CP dome waste, 15mm dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc all complete as per specification and direction of the Engineer in charge. Half stall urinal (Jaquar/Parryware / Hindware make). URS-WHT-13253N Urinal (Back Inlet) |
| 144 | 15mm dia urinal spreader |
| 145 | 32mm dia C.P. dome waste |
| 146 | Supplying all materials, labour, T&P and fixing wash kitchen sink/laboratory sink with outlet at end and weir overflow including fitting and fixing a pair of cast iron or MS brackets painted white, fixing 50mm/40mm dia CP brass waste, fixing 50mm/40mm dia PVC waste pipe 910mm long with supply of wooden plugs, screws and cement etc including cutting holes in walls and making good the damages etc all complete as per specification and direction of the Engineer in charge 600x450x250 mm stainless steel kitchen sink-glossy-IS:13983 - 1994 (Jayna make) |
| 147 | Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps(Plaza make) capstan head screw down high pressure lettered Hot and Cold with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, etc all complete as per specification and direction of the Engineer in charge 550mmx400mm size wash hand basin with Pedestall (Parryware) |
| 148 | Under Counter Basin (560x455) (H)10095 white |
| 149 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge Design Mirror |
| 150 | Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge. |
| 151 | Supplying all materials, labour, T&P and providing cement concrete (1:4:8) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor |
| 152 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor |
| 153 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, paym ent of royalty, taxes etc all complete as per specification and direction of the Engineer in charge 12mm thick CP (1:4) on bw- In gf |
| 154 | Fitting and fixing vetrified tiles on floors or steps & landing on 25mm. thick bed of cement mortar (1:1) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including cost conveyance, royalities and taxes etc. all complete as per direction of Engineer in charge. (Ceramic floor tiles of premium grade Kajaria / Jonshon/Somany make of size 600x600mm to be pre-approved by the Engineer in charge) In Ground Floor |
| 155 | Fitting and fixing vetrified tiles to dados skirting & risers of steps on 12mm. thick C.P (1:3) jointed with neat cement slurry mixed with pigments to match the shade of tiles including cost conveyance, royalities and taxes etc. all complete as per direction of Engineer in charge. (Ceramic wall tiles of Size 600x300mm premium grade Kajaria / Somany make special plain / printed series to be pre-approved by the Engineer in charge) In Ground Floor |
| 156 | Supplying all materials, labour, T&P and fixing Granite tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge In Ground floor |
| 157 | Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. |
| 158 | Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge |
| 159 | Providing & Applying priming one coat with Cement primer of approved brand and manufacture on plaster surface as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete. |
| 160 | Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer, over the plastered wall surfaces to prepare the surface even and smooth as per the instruction of Engineer-In-Charge at all elevations including all material & labour complete. |
| 161 | Preparing surface and painting at all height with two or more coats of interior Plastic Emulsion \\"Royale Shyne\\" of Asian Paints or equivalent of approved shade as per the instructions of the manufacturers; giving uniform shade etc in all heights of walls etc. including interior wall primer & providing scaffolding, cleaning, curing and supply of all materials and labour complete as per drawing, design and direction of Architect/Engineer-In-Charge. |
| 162 | Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:1.5:3) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, fly ash bricks in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI/P-trap gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge Inside size 250mmx250mm |
| 163 | Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge Inside size 760mmx760mmx460mm |
| 164 | Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class K.B brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge Inside size 910mmx910mmx910mm |
| 165 | Supplying all materials, labour, T&P and providing 450mm dia x 50mm thick RCPC man hole cover in cement concrete (1:2:4) using 12mm size h.g chips, placing the cover on the man hole/ inspection chamber and finishing smooth all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification and direction of the Engineer in charge R.C.P.C. Cover(20\\"/22\\" round Man hole cover) |
| 166 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. 1.40m dia x 2.00m deep soakway pit |
| 167 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class 3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturers specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge.(Supreme/Ashirvad/Oriplast/AKG) 110mm dia u-pvc pipe alround concrete |
| 168 | 160mm dia u-pvc pipe alround concrete |
| 169 | Construction of 20 users Brick Septic tank Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-Charge. |
| 170 | Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general. |
| 171 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor |
| 172 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12m size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor |
| 173 | Supplying all materials, labour, T&P and providing brick work with K.B bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:4) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In F&P |
| 174 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 175 | Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor |
| 176 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge R.C.C floor and roof slabs |
| 177 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor |
| 178 | Supplying all materials, labour, T&P and providing cement concrete (1:1.5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In ground floor |
| 179 | Supplying all materials, labour, T&P and providing,fitting and fixing 100mm x 100mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification and direction of the Engineer in charge |
| 180 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge |
| 181 | Sinking of (200 x150)mm dia bore well - 1 No by DTH method - abour for drilling a perfectly vertical bore hole of specified dia for a specified depth below first level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only Drilling of 200mm dia bore 00 mtr to 45mtr |
| 182 | Drilling of 150mm dia bore 45 mtr to 150mtr |
| 183 | Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from first level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials. Lowering of 200mm dia P.V.C casing pipes 00 mtr to 45 mtrs |
| 184 | Cost of 200mm dia PVC (sch-80) pipe |
| 185 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge By DTH Rig |
| 186 | Supplying all materials, labour, T&P for withdrawing casing pipes from the unsuccessful bore well including all necessary equipment and labour as per direction of the Engineer in charge . |
| 187 | Supplying all materials, labour, T&P and constructing Bore well protection chamber of the inside size 650x650x1000hight with cement concrete (1:3:6) using 40mm size hard granite metal on foundation, 1st class Fly ash brickwork in cement mortar (1:3), with base cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:4) inside and outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. |
| 188 | Supply all materials, labour, T&P and providing,fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1phase line voltage ranging from 320 volt to 450 volt conforming to IS:8034/89 with following specifications with suitable control pannel, jointing with GI/PVC/HDPE pipes electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge. 1.50 H.P single phase 3 stage head range 20 to 35 metres, discharge 145 to 110 L.P.M with outlet dia of 25mm |
| 189 | DOL controll pannel |
| 190 | 2.5 Sqmm flat cable |
| 191 | 32mm dia Steel short piece |
| 192 | Steel roop with cover |
| 193 | Well cap |
| 194 | 50mm size CI bracket |
| 195 | 20mm dia rigid UPVC pipe |
| 196 | 32mm Dia brass non return valve(Shakti make) |
| 197 | 32mm dia HDPE pipe |
| 198 | Labour charges for lowering of submesible pumpset with pipes and cables etc. with testing and commissioning at site. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 06, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysAug 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender