Educational and Research Institute Government Departments Closing in 14 days TDR #56642716

Tender For Construction Of X-Ray Room At Dental Institute Dr. Harvansh Singh Judge Institute Of Dental Sciences & Hospital In P.U South C Us, Sector-25, Chandigarh

Issued by Government Departments · Chandigarh, Chandigarh
Tender Value
8.08 Lakhs
Estimated cost
Bid Submission
11 Aug 2026
14 days left
EMD
16500
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of X-Ray Room At Dental Institute Dr. Harvansh Singh Judge Institute Of Dental Sciences & Hospital In P.U South C Us, Sector-25, Chandigarh

BOQ

Name of Work:- Construction of X-Ray Room at Dental Institute Dr. Harvansh Singh Judge Institute of Dental Sciences & Hospital in P.U South C us, Sector-25, Chandigarh
Sl. No. Item Description
1Civil Work
2Steel reinforcement for RCC work including straightening cutting bending ,placing and binding all complete upto plinth level
3Thermo- Mechanically Treated bars (Ref:-5.22.6)
4Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering shuttering finishing and reiforcement - all work to plinth level
51:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size(Ref:-5.1.3)
6Centering and shuttering including struuting propping etc. and removal of form for
7Shelves (cast in situ) (Ref:-5.9.4)
8Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters
935 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (Ref:-9.21.1)
10Providing and laying vitrified tiles in different sizes(thickness to be specified by the manufacturer) with water absorption less than 0.08% and confirming to IS : 15622 of approved brand & manufacturer, in all colours and shade, in skirting riser of steps, laid with cement based high polymer modified quck set tile adhesive (water based)confirming to IS:15477, in average 6mm thickness ,including grouting of joints(Payment for grouting of joints to be made separately)
11Size of Tile 600x600 mm (Ref:-11.47.2)
12Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and shade, laid with cement based high polymer modified quick set tile adhesive (water conforming to IS:15622, of approved brand & manufacturer, in all colours and based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).
13Size of Tile 600x600 mm (Ref:-11.49.2)
14Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :
15In 75x75 mm deep chase (Ref:-12.21.1)
16Making khurras 45x45 cm with average minimum thickness of 5cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding the edge sand making and finishing the outlet complete. (Ref:-12.22)
17Painting top of roofs with bitumen of approved quality at 17Kg per 10 sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm including cleaning the slab surface with brushes and finally with apiece of cloth lightly soaked in Kerosene oil complete:
18With residual type petroleum bitumen of grade VG -10 (Ref:-12.15.1)
1910 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa at 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks of class designation 100 grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat :
20With common burnt clay F.P.S.(non modular) brick tile of class designation 10 (Ref:-12.16.1)
2115mm cement plaster on rough side of single or half wall of mix
221:4 (1cement :4 fine sand) (Ref:-13.2.1)
23Distempring with oil bound washable distemper of approved brand and manufacture to give an even shade
24New work (two or more coats) over and including water tinnable priming coat with cement primer (Ref:-13.41.1)
25Finishing walls with Acrylic Smooth exterior paint of required shade
26New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) (Ref:-13.46.1)
27Providing and applying white cement based putty of average thickness 1 mm of approved brand manufacturer over the plastered wall sufrace to prepare the surface even and smooth complete.(Ref:-13.80)
28Removing white or color wash by scrapping and sand papering the surface smooth including necessary repairs to scratches etc complete (Ref:-13.88)
29Providing and fixing APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrance, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrance manufacture of density at 25°C, 0.87 - 0.89 kg/ litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using Butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/ 5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacture of membrane.
303mm thick (Ref:-14.90.1)
31Providing & laying brick work with F.P. S of class designation 100( average compressive strength not less then 105 kg per sq.cm) in superstructure above plinth level up to V level in all shapes and sizes(Ref. N.S.)
32Cement mortar 1:4 (1 cement : 4 coarse sand
33Providing and making of Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position In gratings, frames, guard bar, ladder, railings, brackets, gates, Trusses and similar works and applying a priming coat of approved steel primer and two coats of approved synthetic enamal paint. complete in all respect to the entire satisfaction of the Engineer-in-Charge. (Ref:-N.S.)
34Providing & fixing readymade (Precut) red agra stone of 40mm thickness of 33\\" x 11\\" (or as per site) size to be fixed with hold fastners(to be paid extra). The work includes dismantling/ cheiseling of existing cement mortar and apply 12mm thick cement mortar 1:3 (1 cement : 3 corse sand) for fixing of stone along with matching colour grout as per stone shade and necessary scaffolding work. Complete in all respects to the entire satisfaction of the engineer in-charge.(Ref:-N.S.)
35Providing & Fixing 6mm thick Toughfened glass to be supported/Fixed with epdm neoprene gasket & screws if any. Complete as per the architectural drawings and the directions of engineer-in-charge.(Ref:-N.S.)
36Electrical Work
37Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc. as required
38Group C (Ref:-1.8.3)
39Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required
403 x 2.5 sq. mm (Ref:-1.17.12)
413 x 4 sq. mm (Ref:-1.17.21)
42Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required
4325mm (Ref:-1.21.2)
44Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required
4575 mm X 75 mm X 60 mm deep (Ref:-1.22.1)
46Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required
475/6 amps switch (Ref:-1.23.1)
483 pin 5/6 A socket outlet (Ref:-1.23.4)
49Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required (Ref:-1.29)
50Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required (Ref:-1.30)
51Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required
524 way (4 + 12), Double door (Ref:-2.4.1)
53Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
54Single pole (Ref:-2.10.1)
55Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. (Ref:-2.16
56Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V \\"C\\" curve TP MCB complete with connections, testing and commissioning etc. as required (Ref:-2.17)
57Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. (Ref:-5.4)
58Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required (Ref:-5.15)
59Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required (Ref:-5.2)
60Supply, installation, testing & commissioning of 63 Amp MCB TPN, 10kA, 'C' curve in the existing distribution board, complete in all respect to the entire satisfaction of engineer in-charge.
61Supplying and fixing 100W socket type 5 step fan regulator on existing plate with all petty materials complete in all respect to the entire satisfaction of the Engineer-in-charge(Ref:-N.S)
62Supplying, installation, Testing & Commissioning of Panel light 36 Watt, 1x4 ft., with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 5700°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm).(Ref:-N.S)
63Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 1 star rated (min), ceiling fan, double ball bearing, 100% copper wound motor with 3 nos. blades, down rod as per site requirement, 2 nos. canopies, shackle kit, safety rope, Power Factor not less than 0.9, Air delivery minimum 210 Cum/Min, THD less than 10%, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required(Ref:-N.S)
64Supply and laying of XLPE insulated PVC inner sheathed aluminum conductor Un-Armoured (3.5 core) cable of size 25 sqmm on the existing cable tray complete in all respect to the entire satisfaction of the Engineer-in-Charge(Ref:-N.S)
65Supplying & lnstallation Inverter Type Split Air-Conditioner 2 TR capacity with R-32 gas, (Inverter type, 3 star rating) with copper condenser. The A.C shall be suitable for 230 Volts +/- 10%, 50Hz single phase & shall be capable of performing following function:- (i) Cooling (ii) Dihumidifying (iii) Air Circulation (iv) Filtering (v) Remote control including installation charges complete in all respect as per manufacture standards including cost of copper pipe with insulation upto 3 MTR i.e. piping for suction and discharge and upto 3.0 Mtr. power wiring between indoor and outdoor 100% copper to the entire satisfaction of E.l.C. complete with copper tubing indoor/ outdoor and condensor unit with copper connection to compressor to the entire satisfaction of ElC. (Ref:-N.S)
66Providing, fixing, testing & commissioning of 22 Guage soft hard copper piping 3/8\\" & 3/4\\" or as per original manufacture of AC Size for flare connection (liquid line & gas pipe) between indoor & outdoor units alongwith 6 mm thick nitrile rubber insulation & protective covering for exposed whether/chasing including cost of chasing brick wall, RCC wall & repairing of original condition as per site requirement, the rate per metre includes cost of 1 metre each of both 3/8\\" & 3/4\\" with insulation and other works etc. Make (Ref:-N.S)
67Supply and Installation of of 5kVA Voltage Stablizer with copper winding having 110-270Volts range for input and output including cost of suitable electrical copper wire up to nearest electrical socket, complete in all respect to the entire satisfaction of Engineer in Charge. (Ref:-N.S)
68Supply and Installation of PVC rigid drain of 3/4\\" including cost of clamping and chasing through walls and making good the same in original condition complete in all respects from indoor unit to disposal point as directed by E.I.C.(Ref:-N.S)
69Supply and Erection of Exhaust Fan (Copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation, epoxy powder coating along with metallic louver. The job includes carriage charges, connection, testing, commissioning etc as required to complete the job to the entire satisfaction of the Engineer-in-charge.(Ref:-N.S)
70300MM Sweep with louver. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56642716
AUTHORITY Government Departments
TENDER VALUE 8.08 Lakhs
LAST DATE 11-08-2026
Authority
Authority Name Panjab University
Work Description Tender for Construction Of X-Ray Room At Dental Institute Dr. Harvansh Singh Judge Institute Of Dental Sciences & Hospital In P.U South C Us, Sector-25, Chandigarh
Basic Detail
Tender No 6890/EE/Mtc.
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 24 Jul 2026
Submission Date 11 Aug 2026
Open Date 12 Aug 2026
Finance
Tender Value 8.08 Lakhs
Tender Fee Ref. Documents
EMD 16500
Exemption Not Available
Document List
89d51b6a-736f-4e33-9604-3efb9f940e06.html
BOQ_115615.xls
Tendernotice_1 (17).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 11, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Aug 12, 2026

Bid Opening Date

Technical bids will be opened and evaluated.