Tender For Annual Maintenance Of Non-Vrf Ac System Of Secretariat Building, Assembly Building,Raj Bhavan And Chief Justice Bungalow Agartala, Tripura For 01(One) Year.
Tender Value
17.24 Lakhs
Estimated cost
Bid Submission
31 Jul 2026
1 days left
EMD
34487
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
tripura → Tripura
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Annual Maintenance Of Non-Vrf Ac System Of Secretariat Building, Assembly Building,Raj Bhavan And Chief Justice Bungalow Agartala, Tripura For 01(One) Year.
BOQ
| Sl. No. | Item Description |
| 1 | Complete servicing of AC machines (Indoor & Outdoor Unit) as per direction of the Engineer-in-charge. |
| 2 | 1.0/1.2/1.5/2.0 TR split type AC. |
| 3 | 1.5 TR window type AC. |
| 4 | 2.5/3.0/4.0/4.5 TR High wall Split, cassette and vertical AC. |
| 5 | Leak testing of condenser & evaporator unit for performance and pressure testing etc and repair with brazing as per direction of the Engineer-in-charge. |
| 6 | 1.0/1.2/1.5/2.0 High wall split and window type AC. |
| 7 | 2.5/3.0/4.5 TR High wall split, cassette and vertical type AC |
| 8 | Charging of fresh refrigerant gas (R-22) for 1.0/1.2/1.5/2.0/3.0/4.0 TR capacity High wall split/window/cassette / vertical AC system as per direction of the Engineer-in-charge. |
| 9 | Charging of fresh refrigerant gas (R-410) for 1.0/1.2/1.5/2.0/3.0/4.0 TR capacity High wall split/window/cassette / vertical AC system as per direction of the Engineer-in-charge. |
| 10 | Charging of fresh refrigerant gas (R-32) for 1.0/1.2/1.5/2.0/3.0/4.0 TR capacity High wall split/window/cassette / vertical AC system as per direction of the Engineer-in-charge. |
| 11 | Charging fresh refrigerant gas for refrigerator (R-134,Hydro Carbon, R-600, R-190) as per direction of the Engineer-in-charge. |
| 12 | Providing, fitting and fixing of hermetically sealed compressor for replacement of defective one of fixed speed AC system as per direction of the Engineer-in-charge. (With one year warranty) |
| 13 | 1.0 TR capacity High wall split type AC. |
| 14 | 1.2 TR capacity High wall split type AC. |
| 15 | 1.5 TR capacity High wall split type AC. |
| 16 | 1.5 TR capacity window type AC. |
| 17 | 2.0 TR capacity High wall split and cassette type AC.. |
| 18 | 2.5 TR capacity High wall split and cassette type AC. |
| 19 | 3.0 TR capacity High wall split and cassette type AC. |
| 20 | 4.0 TR capacity vertical split type AC. |
| 21 | Providing, fitting and fixing of hermetically sealed compressor for inverter technology AC machine as per direction of the Engineer-in-charge. (With one year warranty) |
| 22 | 1.0 TR capacity High wall split and cassette type AC |
| 23 | 1.5 TR capacity High wall split and cassette type AC |
| 24 | 2.0 TR capacity High wall split and cassette type AC. |
| 25 | 2.5 TR capacity High wall split and cassette type AC |
| 26 | 3.0 TR capacity High wall split and cassette type AC |
| 27 | 4.0 TR capacity High wall split and cassette type AC. |
| 28 | Providing, fitting and fixing of hermetically sealed copper condenser unit for replacment of defective one as per direction of the Engineer-in-charge. |
| 29 | 1.0/1.5 TR capacity High wall split type AC. |
| 30 | 2.0/2.5 TR capacity High wall split and cassette type AC. |
| 31 | 3.0/4.0 TR capacity High wall split and vertical type AC. |
| 32 | Fitting, fixing of blower motor of Ac systems after rewinding I/C necessary replacement of bush, shaft etc with complete varnishing as per direction of the Engineer-in-charge. |
| 33 | Providing, fitting and fixing of scroll motor (A.C)of indoor unit split type AC system as per direction of the Engineer-in-charge. |
| 34 | Providing, fitting and fixing of scroll motor (D.C) of indoor unit for inverter technology split type AC system as per direction of the Engineer-in-charge. |
| 35 | Providing, fitting and fixing of swing motor of indoor unit split type AC system as per direction of the Engineer-in-charge. |
| 36 | Providing, fitting and fixing of relay of split type AC system as per direction of the Engineer-in-charge. |
| 37 | Providing, fitting and fixing of air filter of split type and window type AC system as per direction of the Engineer-in-charge. |
| 38 | Providing, fitting and fixing of indoor PCB circuit for inverter technology split/cassete/Vertical type AC system as per direction of the Engineer-in-charge. |
| 39 | 1.0/1.2/1.5 TR split type high wall AC |
| 40 | 2.0 TR split type high wall AC. |
| 41 | 2.5 TR/ 3.0 TR split/cassette type high wall AC. |
| 42 | 4.0TR vertical/cassette type AC.. |
| 43 | Providing, fitting and fixing of outdoor PCB circuit for inverter technology split/cassete type AC system as per direction of the Engineer-in-charge. |
| 44 | 1.0/1.2/1.5 TR split type high wall AC. |
| 45 | 2.0 TR split type high wall AC. |
| 46 | 2.5 TR/ 3.0 TR split/cassette type high wall AC. |
| 47 | 4.0TR vertical/cassette type AC. |
| 48 | Providing and fitting fixing PCB circuit for fixed speed split/cassete type AC as per direction of the Engineer-in-charge.. |
| 49 | 1.0/1.2/1.5 TR split type high wall AC. |
| 50 | 2.0 TR split type high wall AC. |
| 51 | 2.5 TR/ 3.0 TR split/cassette type high wall AC.. |
| 52 | 4.0TR vertical/cassette type AC. |
| 53 | Providing, fitting and fixing of defective PCB transformer for split type AC system as per direction of the Engineer-in-charge. |
| 54 | Providing, fitting and fixing of defective pump motor for cassette type AC system as per direction of the Engineer-in-charge. |
| 55 | Supply and installation of additional length of copper pipe of for suction and liquid line with insulation and necessary wiring (with three pin electrical plug) to connect the indoor and outdoor unit as per direction of the Engineer-in-charge. |
| 56 | 1/2\\" dia.. |
| 57 | 1/4\\" dia. |
| 58 | 3/4th dia. |
| 59 | 3/8th dia. |
| 60 | 5/8th dia. |
| 61 | Providing and Fabrication of M.S platform for placement of condensing unit by using M.S angel of (50x50x5)mm/(65x65x5)mm size base plate, nuts & bolts/universal bracket (GSS) for ODU of split type AC system including all accessories for on-site installation i/c painting, fitting, fixing grouting by cement mixer as per direction of the Engineer-in-charge. |
| 62 | Dismantling and re-installation of 1.0/1.2/1.5/2.0/2.5/3.0/4.0 TR window, split and cassette type AC system as per direction of the Engineer-in-charge. |
| 63 | Providing, fitting and fixing of G.C.I shed of two parts slanting with ridge and necessary structure by using M/S angle of (30x30x5) mm size M.S flat (18x5) mm size over condensing unit i/c painting and finishing as per direction of the Engineer-in-charge. |
| 64 | Providing of 3/4' UPVC pipe of best quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-charge |
| 65 | Providing, fitting and fixing of defective capicitor for window/split type AC system as per direction of the Engineer-in-charge.. |
| 66 | 25mfd capacitor |
| 67 | 36 mfd capacitor |
| 68 | 45mfd capacitor |
| 69 | 50 mfd capacitor |
| 70 | (80-120) mfd capacitor |
| 71 | Providing, fitting and fixing of Terminal Clip system as per direction of the Engineer-in-charge. |
| 72 | PVC tape (Black tap) |
| 73 | Providing, fitting and fixing of thermostat for AC system as per direction of the Engineer-in-charge. |
| 74 | Providing, fitting and fixing of selector switch for AC system as per direction of the Engineer-in-charge. |
| 75 | Providing, fitting and fixing of starting relay for window type AC system as per direction of the Engineer-in-charge. |
| 76 | Providing & charging of compressor oil with capillary complete as per direction of the Engineer-in Charge |
| 77 | Supply and installation of additional length of electrical copper wire 4 mm size with casing size 01 (One) inch including other materials to connect outdoor unit with electrical panel as per direction of the Engineer-in-charge. |
| 78 | Providing, fitting and fixing of fan capacitor 2.0/2.5/4.0/5.0 mfd as per direction of the Engineer-in-charge. |
| 79 | Providing, fitting and fixing of fan blade of outdoor unit of window, split, cassette and vertical type AC system as per direction of the Engineer-in-charge. |
| 80 | Providing, fitting and fixing of connector for split type AC system as per direction of the Engineer-in-charge. |
| 81 | Providing, fitting and fixing of remote with battery for window, split, cassette and vertical type AC system as per direction of the Engineer-in-charge. |
| 82 | Providing, fitting and fixing of coil sensor for split type AC system as per direction of the Engineer-in-charge. |
| 83 | Providing, fitting and fixing of room sensor for split type AC system as per direction of the Engineer-in-charge. |
| 84 | Providing, fitting and fixing of display sensor for split type AC system as per direction of the Engineer-in-charge. |
| 85 | Providing, fitting and fixing of nitral tape (Arrow tape) as per direction of the Engineer-in-charge. |
| 86 | Providing, fitting and fixing cooling coil for refrigerator as per direction of the Engineer-in-charge. (With one year warranty) |
| 87 | Providing, fitting and fixing fan motor for double door refrigerator as per direction of the Engineer-in-charge. |
| 88 | Providing, fitting and fixing timer for double door refrigerator as per direction of the Engineer-in-charge. |
| 89 | Providing, fitting and fixing sensor for double door refrigerator as per direction of the Engineer-in-charge. (With one year warranty) |
| 90 | Providing, fitting and fixing heater coil for double door refrigerator as per direction of the Engineer-in-charge. |
| 91 | Providing, fitting and fixing of contactors for split type AC system as per direction of the Engineer-in-charge. |
| 92 | Deployment of one(01) no. technician in one shift (08 hours) on each working day thoughout the year and other days of the year on as and when required basis to attend the call for maintenance immediately on urgent basis far carring out of work items under AMC. |
| 93 | Cleaning of Filters of Indoor units and Coils of Outdoor units of a AC system as per direction of the Engineer-in-charge. |
| 94 | Providing, fitting and fixing of hermetically sealed compressor for Refrigerator as per direction of the Engineer-in-charge. (With one year warranty) |
| 95 | Remote Battery Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 31, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayJul 31, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender