Drinking Water Supply and Sanitation Government Departments Closing in 26 days TDR #56642662

Tender For Construction Of Mini Tubewell, Pump House, Solar Power Plant And Ground Water Recharging System Along With All Other Appurtenant Civil & Electro-Mechanical Works Including Testing And Commissioning (With Twelve Months Defect Liability Peri

Issued by Government Departments · Dehradun, Uttarakhand
Tender Value
65.26 Lakhs
Estimated cost
Bid Submission
24 Aug 2026
26 days left
EMD
1.31 Lakhs
Bank guarantee accepted
Document Fee
4720
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dehradun → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Mini Tubewell, Pump House, Solar Power Plant And Ground Water Recharging System Along With All Other Appurtenant Civil & Electro-Mechanical Works Including Testing And Commissioning (With Twelve Months Defect Liability Period And 03 Years O&M) On Item Rate Contract Basis Including Supply Of All Materials, Labour And T&P Etc At C Us Of Saraswati Vidya Mandir, Manduwala, District Dehradun Under Honble Chief Minister Announcement No. 553/2025.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 25-Jul-2026 Corrigendum_1 Technical Bid 24-Aug-2026

BOQ

Name of Work:- Construction of Mini Tubewell, Pump House, Solar Power Plant and Ground Water Recharging System along with all other appurtenant Civil & Electro-Mechanical works including testing and commissioning (with twelve months defect liability period and 03 years O&M) on item rate contract basis including supply of all materials, labour and T&P etc at C us of Saraswati Vidya Mandir, Manduwala, District Dehradun under Honble Chief Minister Announcement No. 553/2025.
Sl. No. Item Description
1MINI TUBE WELL CONSTRUCTION
2Transportation of Rig machine, camp equipage, connected T&P and necessary material, tubewell assembly pipe etc. required for drilling upto site of work including loading, unloading, erection and levelling of Rig machine in all respect.
3Drilling of 200 mm dia bore by rig machine in alluvial boulders, Pebbles, rocky stone, sticky clay etc by ODEX system including lowering, welding of casing/perforated pipe from ground level to 130 mts BGL
4Supply and lowering of M.S ERW (Fincut) 200 mm nominal dia casing pipe 7.1 mm thick duly properly beveled at 450 at both end [as per IS 3589/4270 ]( Plain pipe)
5Supply and lowering of 200 mm dia, 7.1 mm thick M.S ERW (Fincut) perforated pipe
6Supply & fixing of 200 mm dia casing shoe suitable for odex drilling and made out of EN-24 steel.
7Development of tube well by air compressor, including erection,running of compressor and yield testing through \\"V\\" notch
8Development of tube well by OP unit including carting of OP unit, T&P at site running of O.P unit and yield test of TW at \\"V\\" notch
9Chemical & bacteriological test of water
10Resistivity survey of site
11SITC OF PUMPING PLANT
12Supply of Submersible pump-set of 100 LPM cold and clear water against a total head of 140 mtrs. with suitable capacity motor to operate on 415±10% Volts, 3 Phase, 50 C/S A.C. Supply complete.(one no.as spare)
13Supply and Installation of wall mounting 7.5 hp Starter cum panel for above submersible motor for operation on 400 volts+/-10%,3 phase, 50 c/s AC supply complete with Cu bus bar, internal interconnection and comprising of star-delta,over load and under load and under voltage protection,Ampere meter, Volt meter operated with selector switch & CT, LT power capacitor, single phase preventor, indicating lamp, door switch with complete internal connection by copper wire.
14Supply of 4 Sq. mm PVC insulated 3- core submersible cable.
1532 Amp.four pole adjustable with enclosure box fixed in wooden board capable for grounting at wall.
16Supply of jointing material such as lugs, tapes etc.
17Providing, supplying, lowering and fixing heavy duty threaded/socketed uPVC column pipes (65 mm) conforming to relevant provisions of Bureau of Indian Standards IS 12818 and IS 4985, suitable for submersible pump applications, with minimum pressure rating of 22 kg/cm² (or equivalent heavy duty class), capable of safely withstanding total operating head, surge pressure, column water load and suspended load of pump-motor assembly, complete with couplers, sealing arrangement and all accessories as required for proper installation and operation.
1865 mm dia sluice valve with hand wheel PN-1.6
1965 mm dia Reflux valve PN-1.6
20Specials for above such as uPVC bend 90º × 65 mm dia - 2 Nos., 65 mm × 65 mm X65 mm M.S.A.F.Tee - 1 No., 65 mm dia. MSDF distance piece 3.0 mtr. Long.-2 Nos., Ventury (65 x 50 mm) - 1 No., 65 mm dia MS DI clamp heavy duty - 1 Set., M.S.T/W Cap 65mm x 200 mm) - 1 No., Jointing above pipes & specials - 1 set.
21Supply of class-B, rubber resistance sheet suitable for 11 KV as per IS 15652 : (2006)
22\\"SITC of 1 No. 25 kVA, 3-phase, indoor type, Oil-Cooled Rolling Contact Type Servo Voltage Stabilizer (SVS) designed for a wide input range of 280V to 460V (P-P) and a precision output of 415V +/- 1%, featuring high-grade electrolytic copper windings, buck-boost transformer technology, and microprocessor-based digital control for balanced/unbalanced load correction.
23Supply, installation, and testing of a maintenance-free grounding system comprising 4 Nos. Chemical Earth Pits with earth enhancement compound and concrete test chambers, interconnected below ground via GI/Copper strips to form a closed-loop equipotential grid (<1.0\ \Omega as per IS:3043); including the provision of a wall-mounted Main Earth Busbar, double-loop body earthing for the Pump and Servo Stabilizer using GI strips, and dedicated instrument earthing for the Automation/PLC panel using copper wire/strips, complete with all excavation, trenching, jointing, termination, and commissioning.
24PLC based control panel integrated with multifunction energy meter through RS485 Modbus Providing and fixing PLC based automatic control panel complete with wall/door mounted HMI touch screen display for monitoring and control of tube well pumping system including indication of electrical parameters, pump status, faults, water level and auto/manual operation complete with communication wiring and accessories.communication for transmission, monitoring and logging of electrical parameters including voltage, current, kW, kWh, power factor and run status complete with communication accessories and control wiring
25Auto phase reversal unit for auto phase correction suitable for total load of tubewell .
26Pressure transmitter
27Signal cabling between RTU / PLC and field instruments including screened/unscreened & control copper cables, PVC conduit pipes, accessories, PVC bends, AC/DC relays with base, flexible pipe, lugs etc complete in all respects.
28Wiring for light point, fan point etc. with 1.5 sq mm FR PVC insulated copper conductor single core cable in surface PVC conduit with piano type switch, phenolic laminated sheet, suitable size GI box, with earth wire of 1.5 sq mm FR PVC insulated copper conductor single core cable etc as required.
29Wiring for circuit/submain alongwith earth wire with the 2x2.5 sq. mm + 1x2.5 sq. mm earth wire size of FR PVC insulated copper conductor single core cable in surface PVC conduit as required.
30Wiring for circuit/submain alongwith earth wire with the 2x4 sq. mm + 1x4 sq. mm earth wire size of FR PVC insulated copper conductor single core cable in surface PVC conduit as required.
31Supply and fixing of metal box of 180 mmx100mmx160 mm deep on surface with suitable size phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 amp and 15x16 amp socket outlet and 15/16 amp piano type switch, connections, painting etc as required.
32Supply and fixing of 6 Way double door way S.P.N. sheet steel, MCB DB, 240 V on surface complete with copper bus bar, neutral bus bar, earth bar, inter connections including earthing etc as required. (But without MCB/ RCCB/Isolator)
33Supply and fixing of 5 A to 32 A, 240 V, 10 KA, C serious MCB suitable for inductive load of following pole in the existing MCB DB complete with connection, testing etc as required.
34Supply and fixing of double pole, 240 V, isolator in the existing MCB DB complete with connection, testing etc as required.
35Supply and fixing of 20 W LED tubelight complete in all respect (Bajaj / Philips / Equivalent make)
36Supply of 3.5 Core × 16 sq.mm Aluminium Conductor, XLPE insulated, PVC sheathed, armoured LT power cable, suitable for 1100 volts grade, conforming to relevant IS specifications, complete in all respects as required at site.
37Stand-alone solar pole light system comprising suitable Wp solar PV module conforming to Bureau of Indian Standards / International Electrotechnical Commission, LiFePO₄/VRLA battery (12.8V, 24–60Ah, 2–5 days autonomy), LED luminaire (30 W, ≥120 lm/W, IP65/66) with inbuilt driver and surge protection, MPPT/PWM charge controller with dusk-to-dawn operation and protections, mounted on 6 m hot-dip galvanized steel pole (≥80 micron) with suitable structure, IP65 battery box, UV-resistant cabling, earthing and all accessories, complete to provide 10–12 hours lighting per day as per MNRE/BIS/IEC norms.
38Supply of heavy-duty manual Chain Pulley Block of 3 Ton lifting capacity with 4.5 metre standard lift, fitted with alloy steel load chain, mechanical brake arrangement, and complete with geared travelling trolley suitable for beam movement, duly tested for safe operation and conforming to relevant IS standards, complete in all respects as required at site.
39Supply of suitable capacity chlorinator dozer pump with all accessories as- Injector and NRV with PVC pipes etc., 200 Ltr.Capacity PVC tank, Starter cum panel, Single phase automatic stabilizer, Chlorine testing kit, Supply of Sodium hypo-chloride (Naocl) solution.
40Supply of Sodium Hypochlorite Solution of approved make and standard concentration, suitable for chlorination and water disinfection applications, packed in sealed containers, conforming to relevant IS specifications, including loading, transportation, unloading and delivery at site, complete in all respects as required.
41Supply of 100 mm dial pressure gauge with control cock and fittings of range 0-10 kg/cm2 - 1 No.
42CCTV camera at MCS with 2 MP, IP dome CCTV colour night vision, Dline 2 port POE switch full Giga, D link connector PVC box, complete wireless communication setup and 128 GB memory card.
43Industrical type online UPS of 2 Kva with 150 AH*2 Battery Unit, Backup For 2 Hours for control supply of automation at tube well
44SITC of hydrostatic level transmitter with non vented presure sensor, sensor cable and necessary accessories complete as per technical specification hydrostatic level transmitter should be capable of transmitting data to MIS as well as LCS .
45Unforseen items such as caution board, danger plate,rubber gloves,rubber shoes and fencing of sevo voltage stablizer with laying of uPVC pipe 65 mm ( Approx. 50 Mtr.) in ground as per requirement etc. complete.
46Installation, testing and commissioning of all electro-mechanical works including erection, alignment, fixing, wiring, connection, trial run, performance testing and successful operation of all associated electrical and mechanical equipment, complete with all necessary accessories, consumables, labour, tools and tackles, as per specifications and directions of Engineer-in-Charge, including one month trial run period after commissioning, complete in all respects.
47On grid 05 KW solar plant -
48Solar Monocrystalline PV module minimum 535 Wp each
49String invertor with power exporting facility to the grid having out put shall be 415 V AC, 50 H3, 3 Phase degree of protection IP-65 with self protective and self diagnositic features such as over voltage over current (both input and output) over/ under grid frequency, over temperature short curcuit , lightening, islanding and surge voltage.
50Hot dipped Galvanised structure including SS nut bolts on the roof of tube well pump house ( Minimum 8 feet height above roof )complete with grouting by block made by cement concrete etc.
51DCDB box between solar panels and the invertor containing DC SPD and DC MCB with fuse set complete
52ACDB box with protective devices for overload and short circuit in between invertpr and AC side
53Copper bonded Lightening arrestor
5403 Nos.Chemical earthing complete with earth wire PVC pits etc as per IE rule
55Cabling work by copper two core AC cable and One core DC cable including HDPE conduit pipe for carrying the copper conductor
56Miscellenious work i.e. meter testing and commissioning of transformer with fixing of 1.1 KV power cable
57SITC of Data logging system (Hard ware and software) for measuring solar irradiance, temperature, AC voltage AC output current output power, energy DC input voltage DC input Current, Temperature invertor stutus, module temperature string voltage & current through GSM modem / wifi with storage of data.
5811KV bidirectional net metering complete as per UPCL guideline ( connection 25 KW-75 KW) with meter box ( suitable for fixing of solar meter with CT ) and all accessories
59Ground water recharging system-
60Transportation of suitable truck mounted ODEX drilling Rig machine with all necessary connection T&P required for drilling including installation and leveling of Rig machine etc.complete in all respect as per direction of Engineer incharge.
61Drilling of bores as per IS 2800-1979 using ODEX 115 (Tubex) attachment required drilling in alluvial, boulder, pebbles, gravel, rockey stone, sticky clay etc. including cost of attachement consumable stores, bits, water POL etc.complete with system of simultaneous lowering of 125 mm nominal bore 7.0 mm thick MSERW fin cut casing pipe complete in all respect as per direction of Engineer-In-charge.
62Supply & Fixing of 125 mm dia 7.0 mm thick as per IS 1239/4270 MSERW fin cut casing pipe from approved manufacturers complete in all respect.
63Supply and fixing of suitable Casing shoe of EN-24 Steel as per requirement of ODEX Attachment complete in all respect.
64Construction of a filtration chamber ( top of the chamber structure (including cover) should be kept 100 mm above the natural ground level to prevent surface runoff ingress ) around an India Mark II handpump for groundwater recharge or greywater filtration purposes including Excavation a circular pit of 2.0-meter diameter and 3.0-meter depth around the handpump location,Construction a circular chamber with brick masonry using class-I bricks in cement mortar (1:5) to a wall thickness of 4 inches (approx. 100 mm) in which Inner surface of the brick chamber to be plastered with 12 mm thick cement plaster (1:5 mix) for waterproofing and structural integrity Providing a 100 mm thick concrete chamber base using M10 grade concrete (1:3:6) or PCC with Above the base, lay filtration media in the following sequence (from bottom to top), each layer of 600 mm thickness ( Layer 1: Boulder 40–60 mm size,Layer 2: Gravel 20–40 mm size,Layer 3: Coarse sand 2–4 mm size,Layer 4: Crushed charcoal 5–20 mm size,Layer 5: Fine sand 0.5–2 mm size ) placing stainless steel (SS) mesh or GL above the base concrete to prevent migration of filter media and allow even distribution of water providing a two-piece rust-proofed with anti-corrosive painted mild steel (MS) cover with handle and locking arrangement for maintenance access with an overflow pipe connection at the top of the chamber to prevent water stagnation during peak inflow complete with material , labour and T&P as per direction of Engineer In Charge.
65Supply and laying of 80 mm diameter HDPE pipe (approxiamately 50 m ) shall be laid to connect the chamber to the nearest building rooftop rainwater downpipe through a bypass chamber ( for first flush), prior to discharging into the main recharge pit.\\"
66Construction (3.60 Mtr. x 3.0 Mtr.) as per attached annexure/drawing in bid document (RCC framed / load-bearing structure as per site condition, complete with roofing, doors, windows, flooring, plastering, painting etc. complete in all respects)
67O&M of all electro-mechanical works in auto mode excluding electricity charges, complete in all respects as directed by the Engineer-in-Charge.
68For first Year
69For second year
70For third year Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56642662
AUTHORITY Government Departments
TENDER VALUE 65.26 Lakhs
LAST DATE 24-08-2026
Authority
Authority Name Drinking Water And Sanitation Department
Work Description Tender for Construction Of Mini Tubewell, Pump House, Solar Power Plant And Ground Water Recharging System Along With All Other Appurtenant Civil & Electro-Mechanical Works Including Testing And Commissioning (With Twelve Months Defect Liability Period And 03 Years O&M) On Item Rate Contract Basis Including Supply Of All Materials, Labour And T&P Etc At C Us Of Saraswati Vidya Mandir, Manduwala, District Dehradun Under Honble Chief Minister Announcement No. 553/2025.
Basic Detail
Tender No 1349/Nivida/144, dated 23.07.2026
Bidding Type Tender
Location
City Dehradun
State Uttarakhand
Key Dates
Publish Date 25 Jul 2026
Submission Date 24 Aug 2026
Open Date 01 Jan 0001
Finance
Tender Value 65.26 Lakhs
Tender Fee 4720
EMD 1.31 Lakhs
Exemption Not Available
Document List
BOQ_115754.xls
dc07efa1-6967-47ad-96cb-0ee7a97e3398.html
saraswatividyamandirtenderdoc.pdf
Tendernotice_1 (17).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 25, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 24, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 26 days
Aug 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 26 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_115754.xls

html

dc07efa1-6967-47ad-96cb-0ee7a97e3398.html

pdf

saraswatividyamandirtenderdoc.pdf

pdf

Tendernotice_1 (17).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail