Tender For Procurement, Supplying And Installation Of Transformer, Dg & Stp In Ayush Hospital At Pati, Dnh.
Tender Value
1.60 Crore
Estimated cost
Bid Submission
01 Aug 2026
1 days left
EMD
3.20 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Dadra and Nagar Haveli → Dadra and Nagar Haveli
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Procurement, Supplying And Installation Of Transformer, Dg & Stp In Ayush Hospital At Pati, Dnh.
BOQ
| Sl. No. | Item Description |
| 1 | Supplying installation testing and commissioning of Transformer of 750 KVA of following capacity (continuous loading) BEE 3 Star rated (Corresponding Level as per BIS amended upto date of receipt of tender) , 33/0.433 KV step down, 3 Phase, 50 Hz, Dyn 11 vector group, ONAN (Oil Natural Air Natural) copper wound transformer (Electrolytic grade 99.9% pure copper, Core made of first grade Cold Rolled Grain Oriented (CRGO) Core grade MOH or better, suitable for out door/indoor applications with On Load Tap Changer (OLTC) on HV side having AVR relay and Remote Tap Changer Control (RTCC) for automatic sensing of incoming voltage, automatic operation of OLTC and facility for remote and manual operation of OLTC HV side in range of +5% to -15% in steps of 2.5%, having cable end boxes on HV side suitable for 3x400 sq.mm XLPE cable of 33 KV grade, including bus trunking arrangement on LV side including supplying and laying of copper conductor multicore control cable from transformer to HT breaker/panel for safety tripping, complete with all accessories and safety provisions as per relevant IS Code including first filling of filtered dehydrated oil, i/c supplying and grouting of suitable M.S. Channel with all accessories and transformer shall be confirming to IS : 2026 (Part 1 to Part 5), IS : 1180 and as per CPWD specifications complete in all respects etc as required at site. |
| 2 | Supplying, Installation, Testing & Commissioning of ‘Silent Type Diesel Generating set of 750KVA as per CPCB IV + or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. complete in all respect including all required for the same and as per direction of the Engineer-in-charge. |
| 3 | SITC of 40 KLD Modular Membrane Bioreactor (MBR) based Sewage Treatment Plant, Design Flow KLD 60.0 LPH 2000.0 Type Fully-Automated, Design MLSS mg/L 6000.0 – 8000.0 Operating Hours h 24.0, Design Flexibility % 30 - 100 with transfer pumps, air blowers, medias, membrine, tube settlers and all connected pipe lnes and necessary power connections and cubicle control panel in all respect. 3 years operation and maintanance of Sysytem is includedCHAPTER - XIII LIFTSNote:-(a) General Features & Special Features of the all lift items shall be taken as below.(b) for Handicap Lifts, Minimum 10 Passengers Lift Capacity shall be considered.same is to be informed to architect /civil authority to keep necessary size of lift well.(c) The lifts of 15/ 16 and above passenger capacity shall be taken for Hospital Lifts; Where in Description “ Stretcher Lifts” shall be mentioned.(d) The Rates of the following items are for the lift of Machine room less. For Machine room Lifts, rate for Rs. 1,50,000/- shall be deducted in Total Cost for the Lifts from 4 to 13 Passenger Lift. Rs. 2,00,000/- shall be deducted in Total Cost for the Lifts 15 and above passenger capacity as extra cost.(e) Add Rs. 80,000/- for the DUPLEX control for the lifts up to 10 floors and add Rs. 10,000/- for additional each floor above 10 floors.(A) GENERAL DESCRIPTION OF LIFTS.[1] GEAR LESS LIFT DRIVE comprising of High Starting torque Lift 3 phase 440 V A. C. Permanent Magnet Synchronous motor of proper rating with high efficiency shall be used.[2] Micro processor based / PLC, ACVVVF, vector control drive with encoder feedback closed loop system shall be used for lift car and door operation which shall be full collective selective operation hall call demand response, UP/DOWN hall stops, Main, Up/ Down Contactor with overload and phase reversal relay and safety controls.[3] Car with M S platform with bracings of adequate size and to sustain the impact load cabin + passenger with safety factor of fire for steel and side panels of Stainless steel of sheet of grade 304 duty. Car ceiling will be S.S. finishes with aesthetic appearance with LED ceiling lights. Car flooring shall be of anti skid PVC with choice of colour of engineer in charge. Car doors shall be of stainless steel grade 304, hairline finish with centre opening / telescopic automatic doors. Car panel will also be S.S. 304 finished with emergency stop device, mechanical door safety device, facility of auto/ attended mode. All car panel buttons and all floor switches must be with brail language as per lift act.[4] All landing doors must be fire rated for 2 hour shall be fully automatic centre opening/ telescopic opening made of hairline finish steel grade of 304 with key holes and infrared curtains with Unlocking facility from outside [5] Appropriate battery operated emergency light in the car along with alarm switch shall be provided. Also, Emergency Light & Fan should start immediately without any Time Delay as soon as power fails.[6] Digital scrolling indicator system for up-down arrow along with floor position indicator shall be provided inside the car and at all floors.[7] Full height infra red curtain with multiple cross / crossing light beams shall be provided.[8] Automatic Rescue Device (ARD) shall be provided accordingly of passenger capacity with Manual Rescue Operation ( Manual Cranking Facility). [9] Audio visual indication in the lift car showing over loading shall be provided such that doors kept open till excess load is removed.[10] Spring buffers/PU Buffers shall be provided.[11] Car fan as per passenger capacity with automatic sleep timer shall be provided.[12] Voice annunciator with suitable music shall be provided in lift car. [13] Self diagnostics system for operational and safety parameters shall be provided in control panel.[14] Mechanical over speed governor with governor calibration as per actual site parameters and submission of calibration certificate submission, door key holes in the floor doors, fireman switch shall be provided.[15] Lift machine hoisting arrangement in the lift machine room and monkey ladder for lift pit should be provided by the lift agency, along with the other steel structure works, foundations for the machine etc…[16] In the hoist way fascia plate shall be provided without any extra cost, where ever required as / if directed by engineer in charge.[17] Permanent wiring with necessary safety devices like RCCB in all circuit, Over Voltage Under Voltage protection and THD eliminator in circuit for lift machine room and lift well with proper numbers of light points, with fixtures, exhaust fan and plug points shall be provided by the agency. Only 3 phase Power Supply shall be made available by department in lift machine room. Necessary Earthing as per Lift Act/Rules shall be arranged by Lift Agency.[18] Any civil/ electrical works for additional and alteration in lift shaft and machine room related to erection of lift shall be made by lift agency without any extra cost. (granite/marble fixing around all landing door openings are not in lift agency’s scope.)[19] Agency has to provide all working drawings and documents and liaison services for obtaining all necessary permission from lift inspector and other authorities. [20] acrylic transparent licence/display A4 size holder in lift car[20A] As per statutory requirement of Govt. Of Gujarat lift & escalator act 2000, lift agency has to provide 1. Car top safety barricade2. Push & talk communication system. 3. Fireman's switch operation at Ground Floor. 4.carrying out third party lift inspection during/after lift erection and provide report by third party authorized by concern licensing authority 5.agency has to provide third party insurance upto completion of free maintenance period and submit the document for the same.[21] Car Panel Operating Buttons with floor position indicator/buttons must be of Auto Glow type clearly visible when view from inside cabin.[22] For Physically Handicapped person Full Length Handrails of hairline finish steel grade of 304 should be provided at appropriate height on the Rear & Side Wall Panels in Lift Car.(B) SPECIAL FEATURES DESCRIPTION OF LIFTS for PREMIUM category1. Advanced control system dual 64 bit embedded microprocessor with CANBUS Serial Communication mode including Regenerative power efficient operation,on site programming facility, Anti nuisance, Pte-opening, BMS/RMS with necessary online real time monitoring system having necessary connectivity for remote monitoring & other suitable supporting hardware & software devices to fulfil the purpose.2. Floor Indication LCD Display with call registration & brail mark with arrival gong and hall lantern & TFT Screen in the car with MP3 Voice Announcer.3. CAR Panel should be Scratch resistive SS Moonrock finish / Hair Line / Honeycomb for car and all Doors, All landing doors must have fire rating up to 2 hours and car door must have multi-level crisscross beam door protection.4. To & fro communication system & wiring (i.e. car , control room & guard room ) and Each elevator are equipped with remote monitoring system.agency has to provide mobile app and user id and password for monitoring Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 01, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayAug 01, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender