Tender For Annual Rate Contract For Repair/ Replacement Of Parts Of Lt Control Panels Installed At Various T/Wells / Dugwells / Pumping Stations With Allied Works Falling Under The Jurisdiction Of Jal Shakti Phe (Mech.) Sub- Division Samba-Ii Of Phe Div S
Tender Overview
Project Description
Tender For Annual Rate Contract For Repair/ Replacement Of Parts Of Lt Control Panels Installed At Various T/Wells / Dugwells / Pumping Stations With Allied Works Falling Under The Jurisdiction Of Jal Shakti Phe (Mech.) Sub- Division Samba-Ii Of Phe Div Samba
BOQ
| Sl. No. | Item Description |
| 1 | Replacement of parts LT Control panels, voltage stabilizers etc: Replacement of damaged Contactor 50 |
| 2 | Replacement of damaged Contactor 70 |
| 3 | Replacement of damaged Contactor 95 |
| 4 | Replacement of damaged Contactor 110 |
| 5 | Replacement of damaged Contactor 140 |
| 6 | Replacement of damaged Contactor 185 |
| 7 | Replacement of damaged Contactor 250 |
| 8 | Replacement of damaged Contactor 300 |
| 9 | Replacement of damaged kit of Contactor 50 |
| 10 | Replacement of damaged kit of Contactor 70 |
| 11 | Replacement of damaged kit of Contactor 95 |
| 12 | Replacement of damaged kit of Contactor 110 |
| 13 | Replacement of damaged kit of Contactor 140 |
| 14 | Replacement of damaged kit of Contactor 185 |
| 15 | Replacement of damaged kit of Contactor 250 |
| 16 | Replacement of damaged kit of Contactor 300 |
| 17 | Replacement of damaged Voltmeter |
| 18 | Replacement of damaged Ampere meter |
| 19 | Replacement of damaged Selector switch |
| 20 | Replacement of damaged CT Coil |
| 21 | Replacement of damaged MPR( Gardian Make) |
| 22 | Replacement of damaged MPR |
| 23 | Replacement of damaged overload relay |
| 24 | Replacement of damaged under voltage relay |
| 25 | Replacement of damaged over voltage relay |
| 26 | Replacement of damaged single phase/ reverse phase relay |
| 27 | Replacement of damaged internal wiring |
| 28 | Replacement of damaged MCCB-100 Amp |
| 29 | Replacement of damaged MCCB-125 Amp |
| 30 | Replacement of damaged MCCB-160 Amp |
| 31 | Replacement of damaged MCCB-250 Amp |
| 32 | Repair to Star Delta Starters of capacity 20 HP/30 HP by way of replacement of damaged contact points, no-load coil, contact point holders, replacement of T-Oil and testing on load. |
| 33 | Repair to Star Delta Starters of capacity 40 HP/50 HP by way of replacement of damaged contact points, no-load coil, contact point holders, replacement of T-Oil and testing on load. |
| 34 | Repair to Star Delta Starters of capacity 60 / 70 HP by way of replacement of damaged contact points, no-load coil, contact point holders, replacement of T-Oil and testing on load. |
| 35 | Repair to Star Delta Starters of capacity 80 HP/100 HP by way of replacement of damaged contact points, no-load coil, contact point holders, replacement of T-Oil and testing on load. |
| 36 | Repair to Star Delta Starters of capacity 100 HP/120 HP by way of replacement of damaged contact points, no-load coil, contact point holders, replacement of T-Oil and testing on load. |
| 37 | Providing and fitting of HRC type main switch 100 Amp |
| 38 | Providing and fitting of HRC type main switch 200 Amp |
| 39 | Providing and fitting of HRC type main switch 400 Amp |
| 40 | Replacement of damaged LT 3-½ core Al. Arrmoured cable with new one of size 70mm² including laying and cost of thimbles |
| 41 | Replacement of damaged LT 3-½ core Al. Arrmoured cable with new one of size 95mm² per meter including laying and cost of thimbles |
| 42 | Replacement of damaged LT 3-½ core Al. Arrmoured cable with new one of size 120mm² per meter including laying and cost of thimbles |
| 43 | Replacement of damaged LT 3-½ core Al. Arrmoured cable with new one of size 150mm² per meter including laying and cost of thimbles |
| 44 | Replacement of damaged LT 3-½ core Al. Arrmoured cable with new one of size 185mm² per meter including laying and cost of thimbles |
| 45 | Replacement of damaged multistrand copper cable with new one of size 16mm² per meter including laying and cost of thimbles |
| 46 | Replacement of damaged multistrand copper cable with new one of size 25mm² per meter including laying and cost of thimbles |
| 47 | Replacement of damaged multistrand copper cable with new one of size 35mm² per meter including laying and cost of thimbles |
| 48 | Replacement of damaged multistrand copper cable with new one of size 50mm² per meter including laying and cost of thimbles |
| 49 | Replacement of damaged multistrand copper cable with new one of size 70mm² per meter including laying and cost of thimbles |
| 50 | Replacement of damaged Submerssible copper cable with new one of size 6mm² per meter including laying and cost of thimbles |
| 51 | Replacement of damaged Submerssible copper cable with new one of size 10mm² per meter including laying and cost of thimbles |
| 52 | Replacement of damaged Submerssible copper cable with new one of size 16mm² per meter including laying and cost of thimbles |
| 53 | Providing & Fititng of star delta starter 10 HP |
| 54 | 20 HP |
| 55 | 30 HP |
| 56 | 40 HP |
| 57 | 50 HP |
| 58 | 60 Hp |
| 59 | 70 HP |
| 60 | 80 HP |
| 61 | 90 HP |
| 62 | 100 HP |
| 63 | Providing & Fititng of MU-G 10 |
| 64 | MU-G 20 |
| 65 | MU-G 30 |
| 66 | MU-G 40 |
| 67 | MU-G 50 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender