Tender For Modification & Up Gradation Of Lighting Arrangement With Other Related Work At Golfgreen Bps
Tender Overview
Project Description
Tender for Modification & Up Gradation Of Lighting Arrangement With Other Related Work At Golfgreen Bps
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 01-Aug-2026 | date corrigendum | Date | 12-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | 150 WATT LED FLOOD STREET LIGHT FITTINGS(MAKE ASPER DIRECTION OF E.I.C). RATE ANALYSIS APPROVED BY DG(E) ON DATED 24/08/19 |
| 2 | SUPPLY TMC501 CONVENTIONAL INDUSTRIAL BATTEN PHILIPS LED TUBE ,MODEL NO. TMC 501 P 1XT-LED 22 W P3241. (RE: ITEM NO. 5.3 F.22 PAGE. 113 GOVT. OF WB IRRIGATION AND WATERWAYS DEPT. USOR(M&E) W.E.F. 10TH MAY,2022) |
| 3 | Fixing only Floodlight Fitting with suitable tie clamps and MS plate FOR mounting on Pole/Tower or similar structure. |
| 4 | Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/ceiling by screws etc. |
| 5 | SCHEDULE OF RATES FOR OVERHEAD LINE INSTALLATION - REPAIR 16. Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting (a) 200 x 150 x 100mm |
| 6 | 90.Supply of PVC insulated unarmoured sheath aluminium conductor cable (1.1KVgrade) (Gloster/incab/Mescab/ Polycab/Havells/Finolex).a)4sqmm x 2core |
| 7 | Laying on Wall / surface with Saddles / clamps.(a)Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (HOT Dip) Wire, making holes etc. as necy. mending good damages and painting |
| 8 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand 6-32 A DP |
| 9 | Outdoor Lighting Installation, Steel Tubular Pole, M.S. Pipe, G.I. Pipe, Pole CAP etc Supplying of Swaged Steel Tubular pole as per IS 2713, Pt. II, 1980 for following designation and of following dimensions.(Outside dia & thickness are given in Annexture -1)f) 410 SP - 11 ; 8.0 Mtr., 83.00 Kg. |
| 10 | Supply and delivery of Ceilling fan 48... Sweep Crompton Greaves make |
| 11 | Supply and delivery of 600 mm sweep, 1 or 3 phase,137 watt, NABL and having 900 mm stand rod, embedded regulator, 3 no 1.1mm thick alluminium bled, having minimum 65 Cu-m air flow Pedesta fan of Orient/ Crompton make. |
| 12 | Supply and delivery of 230V,50Hz Heavy duty Metal 12\\"exhuast fan. |
| 13 | Supply and delivery of Wall fan 16... Sweep metal blade Orient Make |
| 14 | Schedule of Rates FOR Wiring in PVC Insulated and Sheathed Wire in EI Conduits/ GI Conduits By single core stranded Copper conductor.Distribution wiring in 2x1.5 sqmm single core PVC insulated stranded Copper wire in 19 mm in black stove EI conduit/GI conduit to 3 pin Plug Points incl. S&F 5 A Piano Key type switch with earthing attachment in 16 SWG GI Wire and painting.(f)Average run 7.5 mtr.EI Conduit |
| 15 | Schedule of Rates FOR Wiring in PVC Insulated and Sheathed Wire in EI Conduits/ GI Conduits By single core stranded Copper conductor Wiring with 1.1 KV grade single core PVC insulated stranded Copper wire in EI conduit/GI conduit and painting 2x4 sqmm wire in 19 mm conduit incl. S&F 1x14 SWG GI ECC EI Conduit |
| 16 | Schedule of Rates FOR Wiring in PVC Insulated and Sheathed Wire in EI Conduits/ GI Conduits By single core stranded Copper conductor Wiring with 1.1 KV grade single core PVC insulated stranded Copper wire in EI conduit/GI conduit and painting 2x6 sqmm wire in 19 mm conduit incl. S&F 1x14 SWG GI ECC EI Conduit |
| 17 | Concealed Wiring With PVC Insulated and Sheathed Wires in Polythene Pipes - Laying & Fixing PolythenePipe, MS Boxes, Switches etc.Supply & Fixing 240 V, 4 nos. 20A plug socket with separate 4 nos. 20A Piano key type switch, indicator & 20A switch type SP MCB (approved make) on sheet metal switch board embedded in wall incl. S & F 300x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing FOR switch by cutting bakelite/perspex cover and making necessary connections as required |
| 18 | Concealed Wiring With PVC Insulated and Sheathed Wires in Polythene Pipes - Laying & Fixing PolythenePipe, MS Boxes, Switches etc.Supply & Fixing 240 V, 6A plug socket (Brand(approved by EIC), without switch & plug top, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing FOR plug by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc. |
| 19 | Concealed Wiring With PVC Insulated and Sheathed Wires in Polythene Pipes - Laying & Fixing PolythenePipe, MS Boxes, Switches etc.Supply & Fixing 240 V 6 A Piano key type switch (Brand approved by EIC) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing FOR switch by cutting bakelite/perspex cover and making necessary connections as required |
| 20 | Earth continuty condnetor Connecting the equipments to earth busbar including S & F GI (HOT Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages.Solid GI wire.No. 4 SWG. |
| 21 | Sheathed Wires in Polythene Pipes - Laying & Fixing PolythenePipe, MS Boxes, Switches etc.Supplying & Fixing CRC sheet metal (16 SWG) JB-cum- Switch Board of the following sizes complete with three no. suitable size Copper bar with holes ( FOR Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. bakelite/Perspex/coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall FOR housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works 200 mm x 150 mm x 65 mm |
| 22 | Sub Total |
| 23 | GST 18% |
| 24 | CESS 1% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 1 dayBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender