Tender For Construction Of Ev Charging Station At Badaun, District-Badaun
Tender Value
1 Crore
Estimated cost
Bid Submission
10 Aug 2026
13 days left
EMD
2.02 Lakhs
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Budaun → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Ev Charging Station At Badaun, District-Badaun
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 3 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete for all lift. |
| 4 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8.00Kms. From the site of work including watering, dressing etc. labour & T &P etc. required for proper completion of work saplings of girth upto 30 ground level and removal of rubbish upto a distsnce of 50m out side the periphery of area cleared. under floor Local Sand |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : in 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) DSR 4.1.2 |
| 6 | Providing and laying Cement concrete 1:4:8 (1cement :4 C. sand :8 graded stone ballast 40 mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete, also including cost of formwork in foundation. |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal sizederived from natural sources) DSR 4.1.10 |
| 8 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 9 | All works upto plinth level |
| 10 | All works above plinth level upto floor V level |
| 11 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 13 | Foundations, footings, bases of columns, etc. for mass concrete |
| 14 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc |
| 15 | Suspended floors, roofs, landings, balconies and access platform |
| 16 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 17 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 18 | Edges of slabs and breaks in floors and wallsUnder 20 cm wide |
| 19 | Class-150 brick work in 1:6 cement and COARSE sand mortar in foundation and plinth including supply of all materials, labour tools and plants, etc. Required for proper completetion of the work. |
| 20 | Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 21 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 22 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) |
| 23 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the coloumn pitswall tench basement excavation top surface if plinth filling junction of wall and floor along the external perimer of binding expansion joints,surrounding of pipes and conduits etc.complete(plinth area of the building at ground floor only shall be measured as per I.S.6313(Part ll 1981) aldrine emulsifiable concrete or any other approved material such as hepthachlor or chlordance will be used.The rate of application of chemical emulsion shall be as follows:- (1) treatment for masonary & foundation 5 litres per sq.m. (2) back fill in immediate contract with foundation 7.5 litre per sq.m (3)treatment of top surface of plinth filling 5 liters per sq.m. (4) treatment of soil along external parameter of building 7.50 lire per sq.m. |
| 24 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing inposition and binding all complete upto plinth level. Mild steel and Medium Tensile steel bars |
| 25 | Thermo-Mechanically Treated bars work such as in reinforced concreted or reinforced brick work (when not included in overall rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage. |
| 26 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 27 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar w |
| 28 | 40mm thick 1:2:4 cement concrete floor with cement approved coarse sand & 2cm graded dala stone grit laid in planels finished with 3mm floating coat of neat cement bor cement and marble dust in ratio of 5:1 as specific over and excluding base concrete and removing any overlapping mortar at the joints of the panels if any giving them a uniform finish, including supply of all materisls labour, T&P etc. required for proper completion of work |
| 29 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc.,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.10.16.1 Hot finished welded type tube |
| 30 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.18 mm thick |
| 31 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. |
| 32 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent |
| 33 | Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer's specifications & direction of Engineer in-Charge. 60mm thick Cement concrete paver block of M-35 grade with approved colour, design & pattern |
| 34 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes. |
| 35 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00 mm thick with zinc coating not less than 275 gm/m* |
| 36 | Providing and fixing Aluminium sliding door bolts ISI marked anodised transparent or dyed to required colour or shade with nuts and screws etc. complete : 300x16 mm. |
| 37 | Providing and fixing Aluminium tower bolts ISI marked anodised transparent or dyed to required colour or shade with necessary screws etc. complete : 250x10 mm. |
| 38 | Providing and fixing Aluminium handles ISI marked anodised transparent or dyed to required colour or shade with necessary screws etc. complete :125 mm. |
| 39 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover. |
| 40 | Providing and fixing ball bearing for rolling shutters. |
| 41 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm. long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 42 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding |
| 43 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 44 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows all complete with : 4.0 mm thick glass panes. |
| 45 | Providing and laying \\"brick coba\\" 12 mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15 mm to each other, over 20 mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with aerelic cement concrete water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finfished smooth & top mashed false square 30 x 30 cm and side wall parapet shall be monotythic plaster wall upto 30 cm higher and junction and corner shall be rounded by brick ballast cement and coarse sand masonary coba with top finished plaster mixed with acetic water proofing compound @ 2% by weight & including S/o all material, labour, T&P etc complete for proper completion of work. |
| 46 | 12 mm thick plaster with cement mortar in consisting of 1:6 cement and approved coarse sand of minimum thickness not be less than 10 mm including supply of all materials, labour T&P etc. required for proper completion of the work. On smooth surface of wall. |
| 47 | 15 mm thick plaster with cement mortar in consisting of 1:6 cement and approved coarse sand of minimum thickness not be less than 10 mm including supply of all materials, labour T&P etc. required for proper completion of the work. On rough surface of wall. |
| 48 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) On plinth. |
| 49 | 12 mm cement plaster finished with afloating coat of neat cement of mix DSR 13.7.1 ,1:3 (1 cement : 3 coarse sand) |
| 50 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster |
| 51 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 52 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick. |
| 53 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 54 | Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick |
| 55 | Distempering (two coat) with oil bound distemper of approved brand and manufacture and of required shade on undecorated wall surface to give an even shade over and including a priming coat with cement primer of approved brand and manufacture such as Berger, J&N Shalimar, Asian Paints after thoroughly brushing the sufface free from mortar dropping and other forein matter and also including prepairing the surface even with Plaster of Paris or approved synthetic material and sand papered smooth including cost of all material |
| 56 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm overand including priming coat of exterior primer applied @ 0.90litre/10 sqm) |
| 57 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 58 | With ready mixed red oxide zinc chromate primer of approvedbrand and manufacture on steel galvanised iron/ steel works |
| 59 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade, two or more coats on new work |
| 60 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : DSR 13.62.1 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 61 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 62 | Painting two coats over priming coat on steel & other metal surfaces up to 10 cm width or sq,mt in areas with superior synthetic enamel such as Luxol-3 Hi-gloss apcolite superlac, Dulux specified finishing to give an even shade & incl. cleaning the surface of all dirt, dust & other foreighn matter sand preparing and knotting incl. cost of all etc. required for proper completion of work. |
| 63 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. |
| 64 | Brick edging 7cm wide 11.4cm. deep to plinth protection with bricks of class designation 75 including grouting with cement mortar 1:4 (1 cement : 4 fine sand) |
| 65 | Boring with 100 mm diameter casing pipe for hand pump / tubewell, in all soils except ordinary hard rocks requiring blasting, including removing the casing pipe after the hand pump / tube well is lowered and tested : |
| 66 | Up to 6 metres depth |
| 67 | Beyond 6 m and up to 12 m depth |
| 68 | Beyond 12 m and up to 18 m depth |
| 69 | Providing and placing in position filters of 40 mm diameter G.I. pipe with brass strainer of approved quality. |
| 70 | Providing and fixing to filter and lowering to proper levels 40 mm G.I. pipe for tube well including cleaning and priming the tube well. |
| 71 | Supply & Fixing of Handpump (INDIA MARK II) |
| 72 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 73 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 74 | 2 X2.5 sq. mm + 1X2.5 sq. mm earth wire |
| 75 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 76 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 77 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 78 | 4 X 10 sq. mm + 2X6 sq. mm earth wire |
| 79 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 80 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 81 | 5/6 A switch |
| 82 | 15/16 A switch |
| 83 | 3 pin 5/6 A socket outlet |
| 84 | 6 pin 15/16 A socket outlet |
| 85 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 86 | Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required. |
| 87 | 3 Module (100mmX75mm) |
| 88 | 6 Module (200mmX75mm) |
| 89 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Up to 450 mm sweep |
| 90 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 91 | Supplying & fixing suitable size Gl box with modular plate and cover in fronton surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 92 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 93 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A.30KA.FPMCCB |
| 94 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator) |
| 95 | 4 way (4 + 12), Double door |
| 96 | 6 way (4 + 18), Double door |
| 97 | 8 way (4 + 24), Double door |
| 98 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door |
| 99 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 100 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 101 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A |
| 102 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A |
| 103 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 104 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 105 | 3-1/2X 25 sq.mm |
| 106 | 3-1/2 X 120 sq. mm |
| 107 | 3-1/2 X240 sq.mm |
| 108 | 4 X 16 sq. mm (28mm) |
| 109 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.(DSR Civil 2023 Item no. 10.18.) |
| 110 | Supplying, installation, Testing & Commissioning of the integrated type solar PV lighting system on the existing pole structure, comprising of 35 watt, 6V Mono Passivated Emitter and Rear Contact (PERC) Solar Panel (minimum efficiency 21%),, Pulse with modulation (PWM)/Maximum Power point tracking (MPPT) Charge Controller in the box with a sleek appearance and a sturdy structure, is weather-proof, and is simple to install, with Lithium-Iron Phosphate Battery (LiFePO4), charging time 8-10 hours, Battery backup time 12 hours (minimum), LED fixture watt 35 watt, Input voltage: 12V DC , Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%, IP-66,IK-08, CRI >70 , undervoltage and over voltage protection, Electro Magnetic Interference (EMI) Electro Magnetic Compatibility (EMC) As per CISPR 15 , lenses for beam angle as per Illuminating Engineering Society of North America (IESNA) type I/II/III as per the width of the road and the project requirement, Correlated Colour Temperature (CCT) 5700°K (As per American National Standard Institute (ANSI Bin)), life time (LED, Driver & electrical circuitry) of 50K hours lamp buring hours till the 70 % of initial Lumen maintained as per LM80 extrapolation IES TM-21-11 report, automatic swich on/off, Alliuminium or Acrylonitrile Butadiene Styrene (ABS body),can be installed on a pole or wall. System lumen efficacy >120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. All as per pre approved by Engineer in-charge complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required, complete with mounting structure for the battery and accessories suitable for withstand wind storm speed as per the site location. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 35 Watt (System lumen efficacy >120 lm/Watt) |
| 111 | Supply and fixing of 7 mtr. G.I. Octagonal pole of approved make (top dia 70 mm, Bottom dia 130 mm & Base plate 12 mm thick) having 3 mm,thickness with single arm bracket length of I mtr. length in I :2:4 RCCfoundation boh including the cost of foundation, excavation & back fillingand Required T & P complete in all respect. |
| 112 | Earthing with copper earth plate 600 mm X 600 mm X3 mm thick including accessories, and providingmasonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 Meter long etc.with charcoal/ coke and salt as required. |
| 113 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning o LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating andFixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 18- 22 Watt |
| 114 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 115 | Supplying and laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm below ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top as directed by Engineer-Incharge ,complete in all respect including excavation and refilling.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. |
| 116 | 120 sq mm 3-1/2 core |
| 117 | 240 sq mm 3-1/2 core |
| 118 | Supplying and laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at IN Existing RCC/Hume/metal pipe as directed by Engineer-Incharge ,complete in all respect including excavation and refilling.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 120 sq mm 3-1/2 core |
| 119 | Supplying and laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade on wall surface as directed by Engineer-Incharge ,complete in all respect including excavation and refilling.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. |
| 120 | 16 sq mm 4 core |
| 121 | 25 sq mm 3-1/2 core |
| 122 | Supply of AC 450mm Sweep, 230/250 Volts, 50 Hz exhaust fan (Light Duty) with blades,cover etc. complete as required |
| 123 | Supply of Factory made 12 to 20 Watt LED Bulb fitting,cool day light,(65000 K temp.) suitable for Batton/Angle holder including making connection.Complete in all respect. |
| 124 | Supply, Installation, Testing & Commissioning of LED High Bay Luminaire, 100 Watt, minimum 130 lm/W efficacy, cool daylight (5700K–6500K), pressure die cast aluminium housing, powder coated finish, polycarbonate/toughened glass diffuser, IP65 protection, surge protection minimum 4 kV, operating voltage 140–270 V AC, complete with LED driver, mounting accessories, connection, testing and commissioning etc. as required. |
| 125 | Supplying, installation, testing and commissioning of LAN system comprising of core switches & L2 switches with 10 G, 10 giga SFP modules, WIFI access points, WIFI controller, network management software, racks, CAT 6A cable, patch panels, OFC etc. (Rate applicable on plinth area excluding service/common areas). Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 24, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysAug 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender