Housing Urban and Rular Development Government Departments Closing in 6 days TDR #56634126

Tender For General-Rest Houses-Urgent Replacement Of Damaged Electrical Fittings And Improvement To electrical installation At Pwd Rest House Thalassery-General Electrical Work

Issued by Government Departments · Kannur, Kerala
Tender Value
1.26 Lakhs
Estimated cost
Bid Submission
31 Jul 2026
6 days left
EMD
3169
Bank guarantee accepted
Document Fee
555
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kannur → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for General-Rest Houses-Urgent Replacement Of Damaged Electrical Fittings And Improvement To electrical installation At Pwd Rest House Thalassery-General Electrical Work

BOQ

Name of Work:- GENERAL-Rest Houses-Urgent replacement of damaged electrical fittings and improvement to EI at PWD Rest House Thalassery-General Electrical Work
Sl. No. Item Description
1Electrical Maintenance Work
21.10.2:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group B
31.55.1:Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A
4OD255489/2025-2026:Supply, conveyance, installation, testing and commissioning of Exhaust fan in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan,making good the surface as required. 300 mm sweep light duty exhaust fan in metal frame
590.3.19.3:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture
690.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
7OD250313/2025-2026:Supply and Providing the following types and power rated lamps in the existing fittings as required. B22 LED Bulb 9W
8OD250354/2025-2026:Supply and Providing the following types and power rated lamps in the existing fittings as required. B22 LED Bulb 12W
990.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
10OD255282/2025-2026:Supply conveyance, installation, testing and commissioning of Philips Make Model No. 30978 PHILIPS WallLight BrushedNickel 1H (B22 type) Durable metallic housing and Frosted glass with decorative Wall lamp with giving connection etc as required.
1190.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
12OD285220/2025-2026:Supply and fixing of ceiling fan safety Bowden with double side end lock as required
131.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
14OD250357/2025-2026:Supply ,Conveyance, installation, testing and commissioning of 12 W LED Bulkhead Light fittings Lumen output - 600, Housing - High pressure die cast aluminum directly on wall including giving connections with required length of 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, making good the damages, colour washing etc as required.(LUKER STYX ECO BULKHEAD LIGHT 12W LBKOVSL12/equivalent)
151.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
161.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
171.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
181.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
191.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
201.28.3:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module
211.28.4:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
221.28.5:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
231.28.6:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.12 Module
24OD255353/2025-2026:Supply and installation of switch gear units in sheet steel enclosure complete with handle assembly, door interlock and pad locking arrangement of the following ratings on existing angle iron frame work or directly to wall using necessary bolts & nuts, fixing the unit to wall, making good the damages, colour washing etc. including giving necessary connections as required. 63 Amp TPN SDF AC 23A with ISI marked HRC fuse
259.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
261.17.22:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm
271.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
28OD255490/2025-2026:Charges for dismantling the existing EI, complete, making good the damage of walls and conveying the dismantled materials to section store Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56634126
AUTHORITY Government Departments
TENDER VALUE 1.26 Lakhs
LAST DATE 31-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for General-Rest Houses-Urgent Replacement Of Damaged Electrical Fittings And Improvement To electrical installation At Pwd Rest House Thalassery-General Electrical Work
Basic Detail
Tender No PWD/BLDG/TR/23082/2025_6_1_1/1
Bidding Type Tender
Location
City Kannur
State Kerala
Key Dates
Publish Date 23 Jul 2026
Submission Date 31 Jul 2026
Open Date 03 Aug 2026
Finance
Tender Value 1.26 Lakhs
Tender Fee 555
EMD 3169
Exemption Not Available
Document List
0d08a555-137e-4a39-9186-7533b18e9742.html
BOQ_1458188.xls
MOM.pdf
specificconditionNEW.pdf
Tendernotice_1.pdf
viewnit.pdf
viewsbd.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 23, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Aug 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

0d08a555-137e-4a39-9186-7533b18e9742.html

xls

BOQ_1458188.xls

pdf

MOM.pdf

pdf

specificconditionNEW.pdf

pdf

Tendernotice_1.pdf

pdf

viewnit.pdf

pdf

viewsbd.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders